Estimation of arterial pulse wave velocity with a new improved Tissue Doppler method

Similar documents
(received 23 September 2004; accepted 18 October 2004)

EFFECTS OF MECHANICAL PUMPING ON THE ARTERIAL PULSE WAVE VELOCITY : PERIPHERAL ARTERY AND MICRO-VESSELS

A new non-invasive ultrasonic method for simultaneous measurements of longitudinal and radial arterial wall movements: first in vivo trial.

MRI MEASUREMENTS OF CRANIOSPINAL AND INTRACRANIAL VOLUME CHANGE IN HEALTHY AND HEAD TRAUMA CASES

SYNCHRONIZED MEASUREMENTS OF MAXIMUM BLOOD FLOW VELOCITIES IN CAROTID, BRACHIAL AND FEMORAL ARTERIES, AND ECG IN HUMAN POSTURE CHANGES

CONFOCAL MICROWAVE IMAGING FOR BREAST TUMOR DETECTION: A STUDY OF RESOLUTION AND DETECTION ABILITY

Which method is better to measure arterial stiffness; augmentation index, pulse wave velocity, carotid distensibility? 전북의대내과 김원호

A NONINVASIVE METHOD FOR CHARACTERIZING VENTRICULAR DIASTOLIC FILLING DYNAMICS

Suzuka medical university of Science and technology, 2 Ehime University medical department,

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

EVALUATION OF NONINVASIVE PULSE TRANSIT TIME METHODOLOGIES FOR DIAGNOSIS OF HYPERTENSION DANIEL JOHN BADGER. A thesis submitted to the

A new algorithm applied to the analysis of the electrocardiogram of an isolated rat heart. Mostefa Ghassoul MIEEE

Feature Parameter Optimization for Seizure Detection/Prediction

Two-point Method for Arterial Local Pulse Wave Velocity Measurement by Means of Ultrasonic RF Signal Processing

Fondazione C.N.R./Regione Toscana G. Monasterio Pisa - Italy. Imaging: tool or toy? Aortic Compliance

IS PVR THE RIGHT METRIC FOR RV AFTERLOAD?

Original Contribution

PHASE RESPONSE OF MODEL SINOATRIAL NODE CELLS - AN INVESTIGATION OF THE INFLUENCE OF STIMULUS PARAMETERS

DYNAMIC SEGMENTATION OF BREAST TISSUE IN DIGITIZED MAMMOGRAMS

THERMAL RHYTHMOGRAPHY - TOPOGRAMS OF THE SPECTRAL ANALYSIS OF FLUCTUATIONS IN SKIN TEMPERATURE

Previous talks. Clinical applications for spiral flow imaging. Clinical applications. Clinical applications. Coronary flow: Motivation

DETERMINATION OF MEAN TEMPERATURES OF NORMAL WHOLE BREAST AND BREAST QUADRANTS BY INFRARED IMAGING AND IMAGE ANALYSIS

VASCULAR ADAPTATIONS TO TRANSVERSE AORTIC BANDING IN MICE

TEMPERATURE DISTRIBUTION PATTERN IN NORMAL AND CANCER TISSUES: THE EFFECT OF ELECTROMAGNETIC WAVE

Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima Media Region of Brachial Artery

Female sex hormones do not influence arterial wall properties during the normal menstrual cycle

Linear Ultrasonic Wave Propagation in Biological Tissues

ANALYSIS OF PHOTOPLETHYSMOGRAPHIC SIGNALS OF CARDIOVASCULAR PATIENTS

Local Pulse Wave Velocity Estimation in the Carotids Using Dynamic MR Sequences

On the feasibility of speckle reduction in echocardiography using strain compounding

Comparison between abdominal aorta and common carotid artery distension waveforms. MSc thesis Karel van den Hengel December 2009 BMTE 09.

Introduction to Biomedical Imaging

AUTOCORRELATION AND CROSS-CORRELARION ANALYSES OF ALPHA WAVES IN RELATION TO SUBJECTIVE PREFERENCE OF A FLICKERING LIGHT

Pipeline Technology Conference 2007

iu22 Liver Shear Wave ElastPQ

Diagnostic approach to heart disease

Diverse Techniques to Detect Arterial Stiffness

Ultrasound in Medicine

Laser Doppler Vibrometry for Assessment of Pulse Wave Velocity

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Lesson 07: Ultrasound Transducers. This lesson contains 73 slides plus 16 multiple-choice questions.

Dual channel photoplethysmography studies of cardio-vascular response to the body position changes

Proceedings 23rd Annual Conference IEEE/EMBS Oct.25-28, 2001, Istanbul, TURKEY

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

Test-Retest Reproducibility of the Wideband External Pulse Device

Magnetic Resonance Angiography

Edinburgh Imaging Academy online distance learning courses

Optimising your Doppler settings for an accurate PI. Alison McGuinness Mid Yorks Hospitals

Acknowledgements. iii

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

A MODEL OF GAP JUNCTION CONDUCTANCE AND VENTRICULAR TACHYARRHYTHMIA

FACTORS ASSOCIATED WITH THE PREDICTION OF ATTENDANCE TO THE UK BREAST SCREENING PROGRAMME

Original. Stresses and Strains Distributions in Three-Dimension Three-Layer Abdominal Aortic Wall Based on in vivo Ultrasound Imaging

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

Flaw Assessment Using Shear wave Phased array Ultrasonic Transducer

Arterial elasticity imaging: comparison of finite-element analysis models with high-resolution ultrasound speckle tracking

External Oscillatory Blood Pressure - EOBPTM

Hitachi Aloka Medical manufactured one of the world s first diagnostic ultrasound platforms, and today this imaging modality has become the first

Introduction of diverse devices to measure arterial stiffness

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Goals. Access flow and renal artery stenosis evaluation by Doppler ultrasound. Reimbursement. WHY use of Doppler Ultrasound

EYE POSITION FEEDBACK IN A MODEL OF THE VESTIBULO-OCULAR REFLEX FOR SPINO-CEREBELLAR ATAXIA 6

Determination of age-related increases in large artery stiffness by digital pulse contour analysis

Underwater Acoustic Measurements in Megahertz Frequency Range.

Physical Principles of Ultrasound

A GUIDE TO OUR NIBP TECHNOLOGY

Medical Review Approaches to the Diagnosis of Liver Fibrosis

Coronary artery disease (CAD) risk factors

Concepts of Imaging and Knobology

ASSISTANCE TO SURGERY BY MEANS OF INFRARED FUNCTIONAL IMAGING: PRELIMINARY RESULTS

AN INSTRUMENT FOR THE BEDSIDE QUANTIFICATION OF SPASTICITY: A PILOT STUDY

Ultrasound Physics & Terminology

Ann Vasc Dis Vol. 6, No. 2; 2013; pp Online May 30, Annals of Vascular Diseases doi: /avd.oa Original Article

Estimation of Systolic and Diastolic Pressure using the Pulse Transit Time

Juan Carlos Tejero-Calado 1, Janet C. Rutledge 2, and Peggy B. Nelson 3

Descriptions of NDT Projects Fall 2004 October 31, 2004

INFLUENCE OF GENDER, TRAINING AND CIRCADIAN TIME OF TESTING IN THE CARDIOVASCULAR RESPONSE TO STRESS TESTS

Blood Pressure Determination Using Analysis of Biosignals

Ultrasound. Principles of Medical Imaging. Contents. Prof. Dr. Philippe Cattin. MIAC, University of Basel. Oct 17th, 2016

Dynamic measures of arterial stiffness in a rodent model

SITES OF FAILURE IN MUSCLE FATIGUE

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

MR Advance Techniques. Vascular Imaging. Class II

Assessment of Mechanical Properties of Common Carotid Artery in. Vector Imaging

Basic Ultrasound Physics Board Review Questions

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea

The Cardiac Cycle Clive M. Baumgarten, Ph.D.

Flow Quantification from 2D Phase Contrast MRI in Renal Arteries using Clustering

Sound in medicine. CH.12. Dr.Rajaa أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان. General Properties of Sound

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

Vascular disease. Structural evaluation of vascular disease. Goo-Yeong Cho, MD, PhD Seoul National University Bundang Hospital

Hemodynamic Assessment. Assessment of Systolic Function Doppler Hemodynamics

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME

Evaluation of the Quality of Thick Fibre Composites Using Immersion and Air- Coupled Ultrasonic Techniques

FEASIBILITY OF EMG-BASED CONTROL OF SHOULDER MUSCLE FNS VIA ARTIFICIAL NEURAL NETWORK

Computer-aided diagnostic tool for human vital signals detection

Cardiovascular Diseases Detecting via Pulse Analysis

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

Various Indices of Arterial Stiffness: Are They Closely Related or Distinctly Different?

Transcription:

Estimation of arterial pulse wave velocity with a new improved Tissue Doppler method M. Persson, A. Eriksson, H. W. Persson and K. Lindström Department of Electrical Measurements, Lund University, Sweden Abstract- The mechanical properties of the large arteries are important determinants in the circulation physiology. Quantities associated with vessel wall elasticity are of particular interest since they offer a possibility to separate diseased arteries from healthy. Pulse wave velocity (PWV) is a local measure of the arterial wall elasticity. This paper describes a new improved method for non-invasive local PWV estimation. The PWV estimation is based on arterial wall movements, which is detected by Tissue Doppler Imaging (TDI), a color Doppler optimized for low velocities. The TDI facility allows the artery to be measured at several positions simultaneously, which improves the PWV estimation considerably. The method is validated with respect to operator repeatability and operator reproducibility in a limited clinical study. Keywords- Pulse wave velocity, PWV, non-invasive, Tissue Doppler Imaging INTRODUCTION The mechanical properties of the large arteries are important determinants in the circulation physiology [12] Quantities associated with vessel wall elasticity are of particular interest since they offer a possibility to separate diseased arteries from healthy [11]. If the elastic properties of human arteries are generalized, some broad outline becomes evident. One of the most striking facts is that arteries become stiffer with age. In the abdominal aorta, arterial stiffness increases in a linear fashion by age among women whereas men show a faster exponential increase [16]. Furthermore, peripheral arteries are stiffer than more central located [14,9]. The age related stiffening is more pronounced in central arteries than in peripherals [1]. The stiffening is also more evident among individuals with hypertension and among individuals on high sodium diet [1,2]. The pulse wave velocity (PWV) is related to the wall elasticity according to the Moens-Korteweg formula (1), there E is the wall elastic modulus, h the wall thickness, ρ the blood density and R the lumen radius. Unfortunately the formula is of limited use for elasticity estimation due to the uncertain wall thickness determination. However, the pulse wave velocity itself may be used to quantify the arterial wall. This concept gives an estimate of the effective wall elasticity experienced within the lumen rather than the elastic modulus of the arterial wall itself. excised arterial segments in 1922 [5]. To facilitate measurements, arteries were filled with mercury to reduce the propagation velocity. The development of pressure catheters offered a possibility to record pressure waves accurately with minimal disturbances in the circulation system [10]. For a more general use of the PWV concept, noninvasive techniques are clearly desirable. If the status in peripheral arteries is the main interest and average values over larger areas are acceptable, techniques utilizing various types of palpation are suitable. The arterial pulse is detectable on extremities through pressure, strain gauge or mercury ring sensors. These techniques are however less suitable for more selective measurements. Local PWV measurements in specific arteries are simplified if the system depicts the target area. This facility in combination with PWV estimation is offered by MRI and ultrasonic scanners. Since the MRI technology is capable of recording blood flow through arbitrary scan planes, the PWV may be estimated [13]. One of the largest technical limitations of MRI as PWV estimator is the low data capture rate. To achieve an adequate temporal resolution, consecutive sampling of several heartbeats with ECG trigging is required. Recent research has however reduced recording time considerably [4]. An ultrasound scanner equipped with Doppler and ECG trigger may be used in basically the same way. As with MRI, flow waveforms in the different recording sites are not captured simultaneously but compounded off-line with the ECG signal as temporal reference. More specialized ultrasonic systems for PWV estimations allow the two recording sites to be measured simultaneously [3, 6, 7, 12]. Non-invasive ultrasonic techniques for local PWV estimation measure either wall pulsation [3] or wall velocity [6]. The two quantities are interchangeable since a derivation of the pulsation gives the velocity and an integration of the velocity gives the wall pulsation. The aim of this study was to evaluate a new improved algorithm of the method PWV estimation with TDI described by Eriksson et al. [7]. The evaluation was performed in vivo and the study concentrated on operator repeatability and operator reproducibility. c0 = Eh 2R ρ (1) The basic idea in PWV estimation is to record a hemodynamic quantity at two locations simultaneously. The delay between the two waveforms in combination with the measuring distance permits calculation of the wave velocity. Bramwell and Hill performed one of the first studies in this area on METHODOLOGY The PWV was estimated from the arterial wall motion over a defined segment. The wall motion was detected by Tissue Doppler Imaging (TDI), a color Doppler optimized for low velocities. The TDI facility allows the artery to be measured at several positions within same scan, with a short delay between the positions of exploration. The TDI information was

Report Documentation Page Report Date 25 Oct 2001 Report Type N/A Dates Covered (from... to) - Title and Subtitle Estimation of Arterial Pulse Wave Velocity With A New Improved Tissue Doppler Method Contract Number Grant Number Program Element Number Author(s) Project Number Task Number Work Unit Number Performing Organization Name(s) and Address(es) Department of Electrical Measurements Lund University, Sweden Sponsoring/Monitoring Agency Name(s) and Address(es) US Army Research, Development & Standardization Group (UK) PSC 802 Box 15 FPO AE 09499-1500 Performing Organization Report Number Sponsor/Monitor s Acronym(s) Sponsor/Monitor s Report Number(s) Distribution/Availability Statement Approved for public release, distribution unlimited Supplementary Notes Papers from 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, October 25-28, 2001, held in Istanbul, Turkey. See also ADM001351 for entire conference on cd-rom. Abstract Subject Terms Report Classification Classification of Abstract Classification of this page Limitation of Abstract UU Number of Pages 4

provided by an HDI -5000 ultrasonic system. The system was equipped with an L12--5 linear array (6.0 MHz Doppler) and run in the Peripheral Vascular/Arterial application. The data was stored in cineloops as consecutive frames consisting of TDI color information overlapped on the grey scale image, Fig. 1. The cineloops were transferred to a PC through the Research Link for post processing. The cineloops containing pre scan-converted data were visualized on the PC in HDI-Lab, an image processing software designed for off-line cineloop analysis. The settings of the ultrasonic system were optimized for PWV estimation and based on the outcome of the in vitro study [7]. To avoid aliasing, the TDI velocity range had to be extended compared to the previous study. The wider velocity range gave a considerably higher frame rate that reduced the number of heartbeats covered by the acquisition memory. To increase the number of beats, frame rate was reduced by a higher sensitivity. The system settings are given in Table I. dropouts and aliased data were excluded and corrected, respectively. The differential wall velocity was obtained by subtracting the far wall from the near wall. The wall velocity estimation was performed for each TDI line and gave a set of velocity traces as shown in Fig. 2A. The propagation delay along the vessel was estimated by crosscorrelating consecutive velocity traces, Fig. 2C. The delay was given by the peak shift in the correlation function. Since the intrinsic temporal resolution was more than a magnitude lower than typical shifts from adjacent TDI-lines, interpolation was required. A suitable interpolation factor was determined by comparing different factors with a reference (x1024). Based on the information in Fig. 3 an interpolation factor of 512 was chosen. To reduce computational time, a fraction of the interpolation was performed on the correlation function, Fig. 2D. A relation of 4:128 reduced the computational time by a factor of 50+ and gave virtually the same result as the one-step implementation, Figure 4. To improve the estimation, the correlation process was performed on all possible trace combinations, Fig. 2E. Fig. 1. Human carotid artery during expansion. TDI color box is placed to the right so the bifurcation onset remains in view as a reference. TABLE I SYSTEM SETTINGS TDI vel. range [mm/s] ±16.0 Frame rate [Hz] 114 Frames >790 TDI lines 14 TDI box width [mm] 16.8 TDI sensitivity [pulses] 5 Scan velocity [m/s] 17.2 Signal processing The basic idea of the implemented algorithm was to detect the differential vessel wall velocity at multiple sites and estimate the wave delay along the artery. The vessel wall velocities were extracted from tissue motion given by the TDI information. The near and far vessel walls were defined by two manually adjusted region-of-interests (ROIs) Fig. 2A. Starting from the lumen, the first non-zero velocity sample within the ROI was regarded as a valid wall motion. To reduce noise, spatial averaging over ten samples (approximate 2 mm) was used in the axial-direction. Since the sample facing the lumen was considered as the best estimate, linear weighting was used in the averaging process. The first sample was given the weight of one and the last the weight of 1/10. Samples containing Fig. 2. Summarized description of the signal processing. A) The vessel wall velocities were extracted from the tissue motion given by the TDI information. Two region-of-interests, ROIs, defined the desired wall segments. The velocity was interpolated (B) before crosscorrelation (C). The delay was determined from the interpolated correlation function (D). The pulse wave velocity (PWV) was estimated from the delays between the velocity traces (E).

Experimental group The experimental group consisted of six nonsmoking males with no known vascular defects. A physical description of the group is given in Table II. The PWV was measured in the right common carotid artery 20 mm below the bifurcation. The TDI box was placed in the left side of the image to maintain the bifurcation within the field of view, Fig. 1. The subjects were in spinal position and had at least 20 minutes rest before the examination. Each subject was examined by two experienced operators. TABLE II DESCRIPTION OF THE EXAMINED GROUP Subject Age [years] Height [cm] Weight [kg] Pressure [mmhg] A 26 180 87 120/60 B 24 176 68 135/85 C 27 179 64 130/75 D 25 189 75 130/70 E 31 174 84 150/80 F 28 180 73 125/65 Experimental design and statistics The evaluation was performed as a factorial experiment with operator and subject as factors. The experimental design was balanced and 7 replicates were obtained at each level. The study was not completely randomized since the replicates were recorded consecutively and all measurements on a subject were performed at one occasion. The operator order was however randomized. The experimental outcome was evaluated through hypothesis testing. The H 0 -hypotheses were associated with no operator effect, no subject effect and no interaction between operator and subject. RESULTS The estimated pulse wave velocities are shown in Fig. 5. The mean PWV ranges from 5.02 -- 11.24 m/s (subject C and F). The lowest standard deviation is found in subject E (0.65 m/s) and the highest in subject B (1.56 m/s). The overall mean of the examined group is 7.43 m/s. The result of the statistical analysis is given in Table III. The operator has no significant effect on the PWV. There is furthermore no interaction between operator and subject. The subject has a significant effect on the PWV. The repeatability of the method (expected variation when one operator performs multiple recordings on the same subject) was determined to 1.31 m 2 /s 2. The reproducibility (additional variation caused by the operator) was 0.08 m 2 /s 2. Fig. 3. Several recordings were processed with different interpolation factors. The results obtained with a factor of 1024 were defined as reference and subtracted from the other results. The factor 512 was chosen as the best compromise between resolution and required computational time. Fig. 5. Estimated pulse wave velocity in subject A to F. The different box fillings represent operator 1 and operator 2. Fig. 4. To reduce computational time, interpolation was performed before and after the crosscorrelation. The 4:128 split reduced the computational time by a factor of more than 50 and gave virtually the same result as one-step implementation. TABLE III OUTCOME OF THE STATISTICAL ANALYSIS Factor Operator Subject Op ¹ Subj p-value 0.198 < 0.001 0.289

DISCUSSION As shown by the evaluation, there is no significant operator effect. The relatively high repeatability indicates however a considerable recording variability. The obtained variability consists of two components; biological variations and method inadequacies. The amount of physiological PWV variations is difficult to estimate since no reference method was used. We believe that the variability in our study could not entirely be explained by physiological variations. This hypothesis is based on the fact that the human carotid artery has a limited capability for vasoactive work due to the reduced amount of smooth muscle cells [8]. On the other hand, an actual change in wall elasticity is enlarged in the PWV by the quadratic relationship (1). The outcome of an in vitro study represents the method performance under ideal conditions. At comparable settings the in vitro evaluation [7] performed more than a magnitude better in reproducibility. By comparing the velocity traces in the two studies, in vivo data was found to have a considerably higher noise level. The vessel phantom used in the in vitro study (an elastic tube surrounded by water) produced well-defined echoes that gave a low noise level in the estimated wall velocities. In an in vivo situation echoes are less distinct which makes it more difficult to maintain an optimal vessel alignment. The lowest noise levels were found in subject C and E, which also showed the lowest variability. High quality recordings are consequently required to achieve low variability. The relatively high repeatability in this study would have been considerably lower if every recording had been inspected and accepted during the examination. This possibility requires some sort of quality factor to grade the recording objectively. Furthermore, this study shows the value of repeated measurements in TDI based PWV estimations. This study was performed on the carotid artery but several other arteries are of interest. To obtain an accurate estimate of the pulse wave velocity a number of criteria must be fulfilled. The most obvious is that the vessel is detectable. The scan head used in this experiment had a working range of 5--12 MHz, which makes it suitable for superficial arteries. To examine deeper laying vessels such as the abdominal aorta a low frequency scan head is required. The larger depth might however reduce the maximum achievable frame rate, vital for accurate PWV estimation. Large peripheral arteries such as femoral, popliteal, brachial and radial offer, at present state, other difficulties. These arteries are generally stiffer than carotid and have a lower wall pulsation thereby. The available velocity ranges in TDI in combination with the limited dynamic range result in a strong velocity quantization. A lower and for this application more suitable velocity range would unfortunately also reduce the frame rate. Furthermore, the lower velocity range reduces the scan velocity to approximately 7 m/s, which is about half the value found in human muscular arteries [15]. PWV estimation is still possible but the variance tends to increase. CONCLUSION The described method offers a possibility to noninvasively estimate PWV in human arteries. In contrast to traditional non-invasive techniques that give an average value over a large distance, this method measures the PWV locally. The measurements are reproducible and the operator has no significant effect. In present state the system is restricted to superficial highly pulsatile arteries but further technical development will extend its capability. REFERENCES [1] A. P. Avolio, S Chen, R. Wang and among others. Effects of aging on changing arterial complience on left ventrical load in the northern chinese urban community. Circulation, 68:50-58,1983. [2] A. P. Avolio, F. Q. Deng, W. Q. Li, and among others. Effects of aging on arterial distensibility in populations with high and low prevalence of hypertension: comparison between urban and rural communites in china. Circulation, 71:202-210,1985. [3] M. Benthin, P. Dahl, R. Ruzicka, and K. Lindström. Calculation of pulse-wave velocity ussing cross correlations- effects of reflexes in the arterial tree. Ultrasound Med Biol, 17:461-469, 1991. [4] M. Bock, L. R. Schad, E. Müller, and J. L. Walter. Pulsewave velocity measurement using a new real-time mr-method. Magneti Resonace Imaging, 13:21-29,1995. [5] J. C. Bramwell and A. V. Hill. Velocity of transmission of the pulse wave and elasticity of arteries. Lancet, 1:891-892, 1922. [6] P. J. Brands, J. M. Willigers, L. A. Ledoux, R.S. Reneman, and A. P. Hoeks. A non-invasive method to estimate pulse wave velocity in arteries locally by means of ultrasound. Ultrasound Med Biol, 24:1325-35, 1998. [7] A. Eriksson, E. Greiff, T. Loupas, M. Persson, and P. Pesque. Arterial pulse wave velocity with tissue doppler imaging. Journal of Ultrasound in Medicine and Biology, In press. [8] L. C. Junqueira, L. Carneiro, and R. O. Kelly. Basic histology, pages 216-224. Prentice Hall International, London, 7 edition, 1992. [9] R. D. Latham, B. J. Rubal, N. Westerhof, and among others. Nonhuman primate model for regional wave travel and reflections along aortas. American Journal of Physiology, 253:H299-H306, 1987. [10] R. D. Latham, N. Westerhof, P. Sipkema, B. J. Rubal, P. Reuderink, and J. P. Murgo. Regional wave travel and reflections along the human aorta: a study with six simultaneous micromanometric pressures. Circ., 72:1257-1269, 1985. [11] E. D. Lehmann. Pulse wave velocity as marker of vascular disease. Lancet, 348:744,1996. [12] E. D. Lehmann, K. D. Hopkins, and R. G. Gosling. Aortic compliance measurements using doppler ultrasound: in vivo biochemical correlates. Ultrasound Med Biol., 19:683-710,1993. [13] R. H. Mohiaddin and D. B. Longmore. Mri studies of arteriosclerosic vascular disease: Structual evalution and phusiological measurements. Brittish medical Bulletin, 45:968-990, 1989. [14] W. W. Nichols and D. A. McDonald. Wave velocity in the proximal aorta. Medical Biological and Engineering, 10:327-335,1972. [15] W. W. Nichols and M. F. O'Rourke. McDoland's Blood Flow in Arteries, chapter 11, page 361. Edward Arnold, 4 edition 1998. [16] B. Sonesson, F. Hansen, H. Stale, and T. Länne. Compliance and diameter in human abdominal aorta - the influence of age and sex. European Journal of Vascular Surgery, 7:690-697, 1993.