Autopsy Errors with Electronic Control Devices: A Cardiovascular Perspective

Similar documents
TASER and In-Custody Deaths

Cardiac, Physiologic, and Real World Effects of Taser Use

Automated External Defibrillation Principle of Early Defibrillation States that all BLS personnel be trained, equipped and allowed to operate a if

Metabolic Acidosis Detail

Arrhythmias. Pulmonary Artery

FORCE SCIENCE INSTITUTE, Ltd.

The Automated Defibrillator: A Biomedical Engineering Success Story. Dr. James A. Smith

M Series with Rectilinear Biphasic Waveform Defibrillator Option Indications for Use

Ventricular Fibrillation Detail

7860 E. McClain Drive, Suite #2, Scottsdale, Arizona * *

Chapter 24 Field Statistics Overview

Johnson County Emergency Medical Services Page 23

THE FOLLOWING QUESTIONS RELATE TO THE RESUSCITATION COUNCIL (UK) RESUSCITATION GUIDELINES 2005

Sudden Cardiac Arrest and Death Associated with Application of Shocks. from a TASER Electronic Control Device

High Voltage Safety. Dangers of Electricity. W. Maes. Department of Marine Engineering Antwerp Maritime Academy HV, 2015

Electronic control devices (ECDs), also referred to as conducted

Automated External Defibrillation

The ARREST Trial: Amiodarone for Resuscitation After Out-of-Hospital Cardiac Arrest Due to Ventricular Fibrillation

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS

Michigan Pediatric Cardiac Protocols. Date: November 15, 2012 Page 1 of 1 TABLE OF CONTENTS

Performance of Automated External Defibrillators under Conditions of In-flight Turbulence

ADVANCED LIFE SUPPORT

Engineering involved in Cardiac Arrest Management Sahar Sorek

Pediatric Cardiac Arrest General

Version Effective date Changes Prepared By CPR + AED

Improving Outcome from In-Hospital Cardiac Arrest

Update on Sudden Cardiac Death and Resuscitation

CARDIAC ARREST RESEARCH STUDIES. Frequently Asked Questions. Why are these studies being conducted in Milwaukee County?

Dry body skin has a ( higher / lower ) resistance to the flow of the electric current than the internal organs of the body.

OBJECTIVE. 1. Define defibrillation. 2. Describe Need and history of defibrillation. 3. Describe the principle and mechanism of defibrillation.

Update on Sudden Cardiac Death and Resuscitation

Out-Of-Hospital Management and Outcomes of Sudden Cardiac Death Abdelouahab BELLOU, MD, PhD

COALINGA STATE HOSPITAL. NURSING POLICY AND PROCEDURE MANUAL SECTION Emergency Procedures POLICY NUMBER: 716. Effective Date: March 3, 2007

Effects of TASER X26 in Swine R. Walter, A. Dennis, D. Valentino, K. Nagy, J. Winners, F. Bokhari, D. Wiley, K. Joseph, F. Starr, R.

Different indications for pacemaker implantation are the following:

1. The 2010 AHA Guidelines for CPR recommended BLS sequence of steps are:

DEFIBRILLATORS. Prof. Yasser Mostafa Kadah

NON-LETHAL WEAPONS. K. Inaba, MD FRCSC FACS Division of Trauma Surgery & Critical Care LAC+USC Medical Center

The protection you need - without touching your heart

CRC 431 ECG Basics. Bill Pruitt, MBA, RRT, CPFT, AE-C

Feedback Mechanisms. Fever helps the body fight infections but upsets homeostasis.

Assessment of Defibrillation Threshold upon Implantable Cardioverter-Defibrillator implant in Relation to patient s prognosis

Destructive Device Removal - Sparks and Deletion of Therapy History From an Implantable Cardioverter Defibrillator. Case Reports

The 2015 BLS & ACLS Guideline Updates What Does the Future Hold?

Don Eby, MD Local Medical Director, SWORBHP Lesley Pedlar, PCP Bruce County EMS Katie Gibbons, PCP Bruce County EMS

Implantable Cardioverter-Defibril. Defibrillators. Ratko Magjarević

ACP Recertification Pre-Course: Pediatric Manual Defibrillation

Cardiac Arrest CPR. Prof Hugh Grantham

Prognostic Importance of Defibrillator Shock

The Importance of CPR in Sudden Cardiac Arrest

Developments in Cardiopulmonary Resuscitation Guidelines

UNDERSTANDING YOUR ECG: A REVIEW

Indications The AED mode is to be used only on patients in cardiopulmonary arrest.

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing. D. J. McMahon cewood rev

ICD: Basics, Programming and Trouble-shooting

18% Survival from In-Hospital Cardiac Arrest Ways we can do better! National Teaching Institute Denver, CO Class Code: 149 A

Being arrested is a highly emotional event and can

Early Defibrillation. Dr. M. Ravishankar

Rowan County EMS. I m p r o v i n g C a r d i a c A r r e s t S u r v i v a l. Christopher Warr NREMT-P Lieutenant.

The heart's "natural" pacemaker is called the sinoatrial (SA) node or sinus node.

Special health. guide. Hugh Calkins, M.D., and Ronald Berger, M.D., Ph.D. Guide to Understanding. Atrial Fibrillation WITH

Triphasic Waveforms Are Superior to Biphasic Waveforms for Transthoracic Defibrillation Experimental Studies

2015 Interim Training Materials

ACLS Prep. Preparation is key to a successful ACLS experience. Please complete the ACLS Pretest and Please complete this ACLS Prep.

Automatic Identification of Implantable Cardioverter-Defibrillator Lead Problems Using Intracardiac Electrograms

DSED: Is It Real? Brent Myers, MD MPH FACEP CMO and EVP of Medical Operations, Evolution Health Associate CMO, American Medical Response

Biomedical Instrumentation

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

All under the division of cardiovascular medicine University of Minnesota

REPORT 6 OF THE COUNCIL ON SCIENCE AND PUBLIC HEALTH (A-09) Use of Tasers by Law Enforcement Agencies (Reference Committee D) EXECUTIVE SUMMARY

June 2009 CE. Site code # E-1209

Safety and Injury Profile of Conducted Electrical Weapons Used by Law Enforcement Officers Against Criminal Suspects

DEFIBRILLATORS ATRIAL AND VENTRICULAR FIBRILLATION

Flowchart for ICD patients undergoing Surgery or procedures involving diathermy/magnetic fields

Echocardiographic Evaluation of a TASER-X26 Application in the Ideal Human Cardiac Axis

Excited Delirium and CEDs (more Miami mayhem )

MICHIGAN. State Protocols. Pediatric Cardiac Table of Contents 6.1 General Pediatric Cardiac Arrest 6.2 Bradycardia 6.

Cardiac Arrest Registry Database Office of the Medical Director

Supplementary Online Content

Manual Defibrillators, Automatic External Defibrillators, Cardioversion, and External Pacing

Cardiovascular Emergencies. Chapter 12

PEDIATRIC CARDIAC RHYTHM DISTURBANCES. -Jason Haag, CCEMT-P

Implantable Cardioverter Defibrillator with Wireless Charging and IOT Applications

Pacemaker and ICD Interrogation

Being arrested is a highly emotional event and can

ROC ALPS. Amiodarone, Lidocaine, or Placebo Study

Electrical injury : are tasers the new wave?

Primary Therapy for High Risk LQT Patients Should Be an ICD

Biphasic Clinical Summaries

CORONARY ARTERIES HEART

Preparing for your upcoming PALS course

Electroshock weapons: physiologic and pathologic effects - literature review

The Future of EMS as Revealed through Research. A Window into the Near Future

FORCE SCIENCE INSTITUTE, Ltd.

EE 4BD4 Lecture 20. Therapeutic Stimulation

Department of Paediatrics Clinical Guideline. Advanced Paediatric Life Support. Sequence of actions. 1. Establish basic life support

Chapter 15. Objectives. Objectives 01/09/2013. Shock and Resuscitation

Wake County EMS System Peer Review/Clinical Data/System Performance

Review of Pacemakers and ICD Therapy: Overview and Patient Management

SARASOTA MEMORIAL HOSPITAL

Transcription:

Autopsy Errors with Electronic Control Devices: A Cardiovascular Perspective Mark W Kroll, PhD, FACC, FHRS Faculty of UCLA Creativity and Innovation Program Adjunct Full Professor, Biomedical Engineering, Cal Poly Univ. Adjunct Full Professor Biomedical Engineering, U of Minnesota Taser Intl Scientific and Medical Advisory Board.

Co-Authors Jeffrey D. Ho, MD, Dept. of Emergency Medicine, Hennepin County Medical Center, Mpls, MN. Dorin Panescu, PhD, Sunnyvale, CA. Igor R. Efimov, PhD, Washington Univ, St. Louis, MO. Richard M. Luceri, MD, Holy Cross Hospital, Ft. Lauderdale, FL. Patrick J. Tchou, MD, Cleveland Clinic, Cleveland, OH. Hugh Calkins, MD, Johns Hopkins Hospital, Baltimore, MD

Electronic Control Devices are Replacing the Club

In Custody Deaths Correlate with Handcuffs

X26 Waveform Typical peak current: 3.3 amperes Typical peak loaded voltage: 1200 V Pulse average voltage: 400 V Main phase duration: < 100 µs Delivered charge: ~ 100 µc At 70 µs it delivers about 80 µc Average current

TASER ECDs Off the Chart (Well Below Safe VF Limits)

So, How Can It Capture Skeletal Muscles but Not Affect the Heart? Anatomy Skeletal muscles are on the outside of the body. Heart is on the inside of the body. Electrical current tends to favor the grain of the muscle by 10:1 vs. going against the grain. So current tends to stay on the outside. Optimal stimulation pulse widths are different: A-α motor neuron chronaxie: 50 150 µs Heart for transcutaneous stimulation: 4 ms = 4000 µs

Cleveland Clinic Study America s top heart hospital 6 years in a row by U.S. News & World Report. Cocaine increased safety margin by 50-100% Lakkireddy DR, Wallick D, Ryschon K, Chung MK, Butany J, Martin D, Saliba W, Kowalewski W, Natale A, Tchou PJ. Effects of Cocaine Intoxication on the Threshold for Stun Gun Induction of Ventricular Fibrillation. J Am Coll Cardiol 2006;48:805 11.

Breathing Unimpaired Acad Emerg Med. 2007 Feb 5

Medical Electrocution Occurs 500 Times Per Day 1. VF is either induced or not induced within 1-4 seconds. 2. Asystole or PEA are never induced. 3. The cardiac pulse disappears immediately. 4. The patient loses consciousness within 5-15 seconds. 5. A defibrillation shock either internal or external restores a sinus rhythm 99.9% of the time. 6. There is no increased risk of a later VF since electrical current does not linger in the body as a poison or drug might.

2005 Was A Bad Year for Science 4 3 2 1 0 2001 2002 2003 2004 2005 2006

The Index Case for 2005 Ronald Hasse age 54 Naked, on 26th floor Talking to aliens on his cell phone CPD and EMS show up TASER ECD is used to take him into custody Dies

Hasse Headlines Chicago Sun-Times, Jul 29, 2005 Taser Killed Man, Pathologist Finds. In the first ruling of its kind in the nation, the Cook County medical examiner's office has determined the Feb. 10 death of Ronald Hasse was caused by a Taser stun gun Hasse received a five-second electrical burst from the Taser, followed by a 57-second charge, according to Dr. Scott Denton, a deputy medical examiner.

Sun Times story ctd. The primary cause of Hasse's death was electrocution from the use of the Taser, Denton said. A contributing cause was methamphetamine intoxication, he said..55 µg/ml of methamphetamine -- 10% over lethal level But the illegal drug probably would not have killed Hasse without his getting "pushed over the edge" by the Taser's jolts, Denton said. DME stressed that what was different was the long 57 second application which is what killed Hasse.

ECD Download Shows that the Longer Application was the First Not the Latter!

What Really Happened? Hasse tried to kick and bite officers and threatened to infect police with HIV. A 57 second TASER hit dropped Hasse. Immediately after he resisted again. This time they need a 5 second therapy until they are able to get handcuffs on. Hasse then climbed into the stair-chair. Paramedics verify normal pulse and respiration. Hasse wheeled to elevator. Alert with eyes open going into elevator.

Chicago Paramedic

Taken down 26 floors. Collapses on ground floor 8 minutes after ECD application. Defibrillation unsuccessful. Death clearly not caused by ECD: Continued to struggle after first application. Normal pulse after both applications. Normal respiration after both applications. Collapse 8 minutes not 8 seconds after ECD usage. Failure of immediate defibrillation.

Autopsy Mentions of TASER ECDs

Scored Errors Failure to appreciate that with electrocution: 1. pulse disappears immediately, 2. there is loss of physical strength for continued resistance 3. collapse occurs within 5-15 seconds 4. VF rhythm is shown on a cardiac monitor 5. immediate defibrillation is usually successful

Other Scored Errors 6. Blaming the ECD for cardiac physical changes 7. Inclusion of a publicity sensitive safe comment (e.g. we were unable to eliminate the role of the ECD) 8. Assuming prolonged ECD applications are more dangerous than other restraint techniques 9. Claiming that ECDs impair breathing 10. Presumption of a lethal synergy between stimulant drugs and the ECD 11. Use of the ECD in the drive stun mode only since this involves current passing between 2 very close electrodes 12. Unscientific emotional explanations such as last straw or pushed over the edge.

The Scorecard Probable Error in Citing the ECD N Time to collapse 1 minute 21 Continued resistance after ECD application 16 Rhythm other than VF 12 Publicity sensitive comments 9 Assumed drug-ecd electrocution synergy 8 Discharge duration or parity 7 Failure of immediate defibrillation 7 Drive stun mode 6 Last straw or over the edge 6 Cardiac damage ascribed to ECD 4 Assumed ventilation impairment 3

Error Rate of 3.1 ± 1.2 per Autopsy Data as of Abstract Submission 6 5 4 3 2 1 0 35,700 35,900 36,100 36,300 36,500 36,700 36,900 37,100 37,300

TASER-related Errors Dropping Fast!

Error Analysis Conclusions 90% of autopsies have no errors re the role of electronic control devices. Cardiogenic etiology errors are dropping rapidly. It is impressive that medical examiners have rapidly familiarized themselves with: time and causation elements of electrocution, ventricular fibrillation, ECD technology, and excited delirium