EPIC-PLUS System for auditory evoked potentials and neuro-otology. PEA - VEMPs ASSR - E-ABR FACIAL NERVE

Similar documents
ECHOLAB. Screening and Clinical Modality. User Programmable Protocols. Otoacoustic Emissions System TEOAE - DPOAE - ABR - AABR

AUDIOLAB Two channel clinical audiometer. Tonal Audiometry Vocal Audiometry MASKING SISI ABLB Decay Test BEKESY

Neuro-Audio Version 2010

ABR PTA ASSR Multi-ASSR OAE TEOAE DPOAE SOAE VEMP ECochG MLR P300

BIO-LOGIC PRO NAVIGATOR TRUSTED TECHNOLOGY. RELIABLE RESULTS.

III. Comprehensive. Efficient. Auditory EP Testing

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

TWO CHANNEL CLINICAL AUDIOMETER AUDIOSTAR PRO

Advanced. NEW! Four times faster DPOAE: concurrent measurement of both ears while recording two DPs simultaneously in each ear!

GSI AUDIOSTAR PRO CLINICAL TWO-CHANNEL AUDIOMETER

INTRODUCTION TO PURE (AUDIOMETER & TESTING ENVIRONMENT) TONE AUDIOMETERY. By Mrs. Wedad Alhudaib with many thanks to Mrs.

But, what about ASSR in AN?? Is it a reliable tool to estimate the auditory thresholds in those category of patients??

Provisional guidelines for using Auditory Steady State Responses (ASSR) in babies. July 2009

Neuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards

PERIPHERAL AND CENTRAL AUDITORY ASSESSMENT

The following describes general use of ELIOS device

GRASON-STADLER HEARING ASSESSMENT SYSTEMS

AA-M1C1. Audiometer. Space saving is achieved with a width of about 350 mm. Audiogram can be printed by built-in printer

The Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems

Science made smarter. Titan. Advanced made flexible. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

THRESHOLD PREDICTION USING THE ASSR AND THE TONE BURST CONFIGURATIONS

BERA The HOMOTH ABR / BERA- module is a real time brainstem audiometer. It is developed considering the latest knowledge of the ENT research.

OAE Test System. Screener PLUS. Diagnostic PLUS. with 4 frequency DPOAE testing Protocols

The Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform

General about Calibration and Service on Audiometers and Impedance Instruments

Oscilla - excellence since 1960

Audiology Equipment p r o d u c t s c AtA l o g u E

ERO SCAN. OAE Test System. Screener. Diagnostic. with 4 frequency DPOAE testing Protocols

GSI AUDIOscreener OAE AND ABR HEARING SCREENING

Speech Therapists and Audiologists 2007

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

AD226 Diagnostic Audiometer

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

UNITY 2. a state-of-the-art audiological integrated diagnostic and fitting system

QUICK START GUIDE SENTIERO OAE, TYMP AND AUDIOMETRY SCREENING ( and )

A full product range for your every need. World leading diagnostic solutions

AC40. Clinical Audiometer. Save time Focus on results. Interacoustics. l e a d i n g d i a g n o s t i c s o l u t i o n s

Diagnostic Audiometer

Handheld OAE-Tympanometry Combination System

Equinox 2.0. PC-based audiometer. Time saving solutions. Interacoustics. leading diagnostic solutions

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.

Audiological Diagnosis after Newborn Screening

Bio-logic AuDX PRO FLEX Screening tympanometry and audiometry Quick start guide

James W. Hall III, Ph.D.

by Maico Diagnostics

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

Contents. Foreword by James W. Hall III, PhD and Virginia Ramachandran, Aud, Series Editors Preface

myaudiometer. It s familiar, and it s so much

QUICK START GUIDE TYMPANOMETRY AND AUDIOMETRY FOR SENTIERO DESKTOP DEVICES

AC40 Technical Specificatons Page 1. Technical Specifications AC40. Clinical Audiometer

AMBCO 1000+P AUDIOMETER

BioMed Jena GmbH -Biomedical Technology- PRODUCT CATALOGUE AUDIOLOGY

CE-Chirp. Making ABR fast, accurate and clear! Stimulus Family

Instructions for Use. Oscilla TSM400 Screening Tympanometer. Specifications are subject to change without notice ID: 6795 / ver.

AMBCO AUDIOMETER

Updates to NHSP guidance for post-screening diagnostic testing Update 1: August 2015 Author: BSA Electrophysiology Special Interest Group (BSA EP SIG)

Quick Guide - eabr with Eclipse

Bio-logic AuDX PRO FLEX Quick start Quick start guide

AC40 Technical Specificatons. Technical Specifications AC40. Clinical Audiometer D F 2017/11

Neurostyle. Medical Innovation for Better Life

The registration testing for audiometric device in CFDA

AT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.

Emissions are low-intensity sounds that may be detected in the external ear canal by a microphone

MAGPRO. Versatility in Magnetic Stimulation. For clinical and research use

Reliable, flexible & precise

Tune in on life with SCOLAbuddy. A new fm receiver from Widex

UPDATE ON ELECTROPHYSIOLOGIC MEASURES OF HEARING SENSITIVITY IN INFANTS

NEURO-AUDIO. Auditory EP (ABR, ASSR, ECochG), PTA and OAE tes ng in one unit. Complete solu on: screening, diagnos cs, research

1- Cochlear Impedance Telemetry

AUDIOMETERS AUDIXI 10

QUICK START GUIDE SENTIERO DESKTOP OAE AND TYMP SCREENER (BLUE HOUSING)

ERO SCAN. Otoacoustic Emission Testing

AccuScreen ABR Screener

QUICK START GUIDE SENTIERO DESKTOP DIAGNOSTIC (WHITE HOUSING)

Effect of intensity increment on P300 amplitude

Audiology (Clinical Applications)

AA222 / AA220. Audio Traveller. Save time on routine. Focus on results. Interacoustics. leading diagnostic solutions

The Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform

SLHS 588A Electrophysiologic Assessment Techniques: FALL Class Meeting: Room 229-SLHS, MW 2:00 to 3:15 p.m; Lab: TBA;

(Otoacoustic Emissions and Automated ABR)

the truly automated all-in-one hearing screener

ABR Screener Excellence in Newborn Hearing Screening

The true clinical hybrid audiometer Stand alone & PC-based audiometry in one box. Interacoustics. Clinical Audiometer AC40.

ER75 Electro-Acoustic Ear Simulator. Operating Manual

Official CPT Description

the truly automated all-in-one hearing screener Only the Echo-Screen Hearing Screener combines

The Verification of ABR Response by Using the Chirp Stimulus in Moderate Sensorineural Hearing Loss

Evoked Potenital Reading Session: BAEPs

MA 25 Operating Manual

Infants, auditory steady-state responses (ASSRs), and clinical practice

Audiology Curriculum Post-Foundation Course Topic Summaries

Glossary For Parents. Atresia: closure of the ear canal or absence of an ear opening.

ABR assesses the integrity of the peripheral auditory system and auditory brainstem pathway.

Testing Digital Hearing Aids

Evoked Potenital Reading Session: BAEPs

Wheeler, K.S. M.Cl.Sc. (Aud) Candidate School of Communication Sciences and Disorders, U.W.O

Transcription:

EPIC-PLUS System for auditory evoked potentials and neuro-otology PEA - VEMPs ASSR - E-ABR FACIAL NERVE

EPIC-PLUS System for auditory evoked potentials and neuro-otology Epic-plus, a unique solution. With Epic-plus the Labat s technology has developed a system for evoked potentials that satisfies all the audiological needs. It is a clinical system designed to give the audiologist and ENT a complete series of audiological tests. A simple connection of the Epic plus to the USB port of a PC will make available a high level electro-diagnostic system capable of executing all types of auditory evoked potentials.

Epic-plus can be used for high-level research as well as routine testing in the clinic, hospital or private office. Due to its size and weight it can be a portable system for multiple offices. Epic-plus, semplicity.

Epic-plus in Audiology Automatic calculation of the latencies difference The difference in latency between right and left responses is automatically calculated and displayed using the trace comparison function. Preprogrammed or personalized tests The preprogrammed tests required just a simple click of the mouse and allow an immediate use of the system. The stimulation and acquisition parameter can be temporarily modified at any time as circumstances dictate. Specific protocols with personalized parameters can be added to the list as needed. Auditory threshold test For pediatric audiology, in line with present diagnostic and prevention guidelines, Epic-plus comes with a threshold protocol which allows an evaluation of the patient s hearing threshold in a short time. This can be coupled with the automatic PASS/REFER function. VEMPs? Easy The standard AEP configuration allows an easy execution of the VEMP tests by simply selecting the test from the list. Just apply the electrodes, and press start.

LAP, the most evolved audiological software. Labat s technology has developed an exclusive software program as an answer to audiological needs. The LAP program allows the direct transfer of data from the measuring instrument to the computer and simplifies the statistical data manipulation. With the LAP program the user can visualize all the tests of each single patient. Statistical data can then be obtained by age, types of abnormalities, date of testing etc. The LAP program is especially useful in neonatal screening to extract the REFER patients in order to automatically recall them for the next phase of testing. The LAP program comes with all of Labat s audiological instrumentation. E-ABR Epic-plus communicates with everyone Configuring the trigger control via the LAP software, and interfacing the various brands of cochlear implants presently on the market, the Epic-plus can perform the E-ABR test. The programmable electrical artifact suppressor built into the pre-amplifier facilitates the acquisition of the responses.

ElectroCochleoGraphy An optional kit is available for non-invasive ECoG with Tympanic Membrane wick electrode. The stimulus is delivered through ER 3A insert phones. The LAP software calculates the relationship SP/AP. Printing of the reports The LAP software allows the reports to be printed according to the individual s needs. For example it is possible to print a single trace, multiple traces or the entire set of traces as in Threshold ABR. Constant Current Stimulator Used in the Facial Nerve and Blink Reflex tests, the optional constant current stimulator is available in two versions. The software with the calculations of the responses resides in the LAP. ABR THRESHOLD ABR ASSR

Epic ASSR innovative and easy to use The user s interface, simple and intuitive The ASSR option for the Epic-Plus E.P. system gives a pure tone at various frequencies that can be modulated in AM and/or FM mode at a continuous cycle ASSR, MSSR monaural or binaural and consist of: Additional software for the execution and analysis of the Steady-State test with real time FFT graphic during the acquisition Electronic circuit board, to be inserted in the Epic s main unit, with polynomial two independent channels generator which allows the generation of AM/FM modulated tones at continuous cycle with carrier frequencies for 250 to 10.000 Hz Programmable modulating frequency, programmable percentage of modulation in AM/FM Contemporaneous number of generated frequencies from 1 to 10 The resulting data can be easily reviewed. The stimulus parameters can be personalized and a library of stimuli can be created.

Specifications and features can be changed without notice. Rev. 02 November/2009. Advertisement addressed to ENT professionals. Epic is a PC-based Class 2 type BF evoked response system performing Auditory and Oto-Neurological test. ACQUISITION Number of channels: 2 Acquisition mode: 16 bit ADC, optically isolated CMR: 100 db Low pass filters: from 5 Hz to 5.000 Hz programmable High pass filters: OFF to 500 Hz Smoothing: OFF to 8KHz, preset for selected test Amplifier gain: programmable 1 to 50 Analysis time: from 1 to 999 ms Stimulation rate: from 1 to 100 Hz Trigger in: TTL standard Trigger out: TTL standard ELECTRODE IMPEDANCE Built-in meter for each channel, monitoring single electrode (Z+ and Z-) and differential impedance ACOUSTIC STIMULI Type of stimuli: Click, Logon, Tone pip and Tone bursts Masking: white noise, contralateral Outputs: AC R, AC L, AC Binaural, BC R, BC L and BC Forehead Stimulus polarity/phase: positive, negative, alternated Click: rarefaction, condensation, alternated Phase: 0-90 - 180-270 e 360 programmable FREQUENCY RANGE (Hz) STIMULUS TDH-49 ER-3A B71 BC LOGON 125-8.000 Hz 125-8.000 Hz 250-6.000 Hz BURSTS 125-8.000 Hz 125-8.000 Hz 250-6.000 Hz MAXIMUM OUTPUT (db) STIMULUS db TDH-49 ER-3A B71 BC CLICK Pe SPL 128 128 80 LOGON Pe SPL 128 115 80 BURSTS HL 120 110 70 MASKING SPL 110 110 N/A AEP STANDARD ACCESSORIES Paired TDH-49 supra-aural phones AEP 2 channels preamplifer Patient push-button CDROM with software including all test modalities Ag/AgCl surface electrode kit Abrasive paste Conductive paste 15 V external power supply for medical equipment Power cord set, universal. GND cable USB port: built-in - USB cable provided Instruction Manual Carrying case EPIC specifications AEP OPTIONAL ACCESSORIES ECochG kit, including ER-3A insert phones, electrode cable for ECochG test and ECochG electrode Newborn AEP pre-jelled surface electrodes B71 BC Vibrator Footswitch for Facial Testing Technical manual (on demand) STIMULUS CHARACTERISTICS Click LOGON BURSTS MASKING 10, 20, 50, 100, 200, 500, 1000 ns Envelopes according to EN 60645-3 Duration depends on selected frequency Plateau: programmable from 1 to 500 ms Rise-fall time: programmable from 1 to 500 ms TOTAL HARMONIC DISTORTION 1% FREQUENCY ACCURACY better than 1% Continuous, contralateral SIGNAL TO NOISE RATIO, ON/OFF RATIO, CROSS-TALK 70 db POWER SUPPLY Power supply: external 15 V Switching Power Supply 100-240 Vac; 50/60 Hz for medical equipment Power Consumption: 800 ma max ENVIRONMENTAL Shipping/storage temperature: -20 to +50 C; -4 F to +122 F Operating temperature: +10 C to +40 C; +50 F to +104 F Operating relative humidity: 30% to 90%, not condensing MECHANICAL Dimensions: cm 27,5 (w) x 29,5 (d) x 6 (h) - 10,8 (w) x 11,6 (d) x 2,4 (h) Weight: 1000 grams (2,2 lbs) net - shipping 7 kilos (15.4 lbs) STANDARDS Audiometry: EN 60645-1 (1994); EN 60645-3 (1995); ANSI S3.6 (1996); EN ISO 389 (1995) Safety: EN 60601-1 (1990) class 2 type BF; EN 60601-1-1 (2000) ENC 60601-1-2 (2001) Via Don Tosatto, 39-30174 MESTRE (VE) - ITALY Tel. +39 041 2667686 - Fax +39 041 616124 - www.labat.it - info@labat.it