Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement

Similar documents
Effect of. Conversion Degree and Hardness of Dual-cured Resin Cement

Effect of Veneering Materials and Curing Methods on Resin Cement Knoop Hardness

Effect of Shade and Thickness of Porcelain Veneers on Depth of Cure of Light-Cured Resin-Based Luting Cement

Influence of the light curing unit and thickness of residual dentin on generation of heat during composite photoactivation

The effect of light curing units, curing time, and veneering materials on resin cement microhardness y

Transdental Photo-activation Technique: Hardness and Marginal Adaptation of Composite Restorations Using Different Light Sources

Effect of light irradiation distance during intermediate. polymerization on depth of cure and hardness of. indirect composite

Curing efficiency of various resin-based materials polymerized through different ceramic thicknesses and curing time

Effect of Time and Polymerization Cycle on the Degree of Conversion of a Resin Composite

G-CEM LinkAce. The new strength in self-adhesive cement

Effect of Different Initial Light Intensity by the Soft-Start Photoactivation on the Bond Strength and Knoop Hardness of a Dental Composite

Hardening of a dual-cure resin cement using QTH and LED curing units

Clinical performance of a premolar jacket crown made of a highly loaded indirect composite and seated with an adhesive luting agent: A clinical report

Effect of curing mode on the hardness of dual-cured composite resin core build-up materials

Research Article Surface Hardness of Resin Cement Polymerized under Different Ceramic Materials

G-CEM LinkForce. Made to fit. Designed to last. from GC. all your adhesive challenges. Dual-cure adhesive luting cement

Development of dental resin luting agents based on Bis-EMA4: bond strength evaluation

The Influence of Temperature on the Efficacy of Polymerization of Composite Resin

Influence of Curing Light Attenuation Caused by Aesthetic Indirect Restorative Materials on Resin Cement Polymerization

Composite resin and metallic posts are the materials most employed for reconstruction of

Effect of Different Modes of Light Modulation on the Bond Strength and Knoop Hardness of a Dental Composite

STUDY ON FILM THICKNESS OF FOUR RESIN CEMENTS

Effect of Different Thicknesses of Pressable Ceramic Veneers on Polymerization of Light-cured and Dual-cured Resin Cements

Self-Adhesive (SA) Cement VS Dual-Cured (DC) Resin Cement

TRANSMITTANCE CHARACTERISTICS OF DIMETHACRYLATE RESIN BASED DENTAL COMPOSITES

Charisma Topaz PRODUCT INFORMATION. The three - in - one composite solution. Heraeus Kulzer Nordic AB

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Effect of Light Curing Units on Marginal Adaptation and Hardness of Class II Composite Resin Restorations

5,6 Significant improvements of the dentin bond

REINFORCED COMPOSITE BLOC FOR PERMANENT RESTORATION. BRILLIANT Crios. High performance made brilliant

Comparative efficiency of plasma and halogen light sources on composite micro-hardness in different curing conditions

Comparison of Temperature Changes in the Pulp Chamber Induced by Various Light Curing Units, In Vitro

G-CEM LinkForce. Strong. Dependable. Universal.

Effects of Different Temperatures and Storage Time on the Degree of Conversion and Microhardness of Resin-based Composites

Effect of light curing units on physical properties of composites

In-Depth Polymerization of a Self-Adhesive Dual- Cured Resin Cement

Changes in Degree of Conversion and Microhardness of

QUARTZ SPLINT. Our fiber expertise is your strength TM.

Effectiveness of Second-generation Light-emitting Diode (LED) Light Curing Units

Comparison of Quartz-Tungsten-Halogen, Light-emitting Diode, and Plasma Arc Curing Lights

Polymerization of dual cured composites by different thickness

Assistant Professor and Consultant, Department of Restorative Dental Science, College of Dentistry, Taibah University, Al Madinah Al

Efficacy of New LED Light-Curing Units in Hardening of Class II Composite Restorations

Effects of layering technique on the shade of resin overlays and the microhardness of dual cure resin cement

Effect of Reduced Exposure Times on the Microhardness of Nanocomposites Polymerized by QTH and Second-generation LED Curing Lights

Surface Hardness Properties of Resin-Modified Glass Ionomer Cements and Polyacid-Modified Composite Resins

Calibra. Cements. The Simple Choice for Easy Cleanup

Review Article Effect of Recurring Procedure on the Surface Micro hardness Values of Different Composite Resins

Influence of different light curing units on the bond strength of indirect resin composite restorations

CERASMART. The new leader in hybrid ceramic blocks

INFLUENCE OF APPLICATION SITE OF PROVISIONAL CEMENT ON THE MARGINAL ADAPTATION OF PROVISIONAL CROWNS

Cementation of crowns, bridges, inlays and onlays. Made of conventional porcelain, ceramic, hybrid ceramics or composite resin Cementation of veneers

Real fast. Real tough. Real easy. Psst it s the one on the left. Lava Ultimate. CAD/CAM Restorative

Evaluation of a Second-Generation LED Curing Light

Glass Ionomers. Reputable, Durable, Long Lasting

Ceramic Based Aesthetic CAD/CAM Restorative

illustrated technique guide

XP BOND IN SELF-CURE MODE USED FOR LUTING PORCELAIN RESTORATIONS:

XP Bond in Self-Cure Mode Used for Luting Porcelain Restorations: 4-year Recall

EASY TO REMOVE HARD TO FORGET! PANAVIA SA Cement Plus Automix

INFLUENCE OF FOUR DIFFERENT CEMENTS ON

Surface/Interface Morphology and Bond Strength to Glass Ceramic Etched for Different Periods

Pulse-delay Curing: Influence of Initial Irradiance and Delay Time on Shrinkage Stress and Microhardness of Restorative Composites

Vickers Hardness of Composite Resins Cured with LED and QTH Units

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Summary of in-vivo studies. RelyX. Unicem. Self-Adhesive Universal Resin Cement. Clinical studies

The Sof-Lex Finishing and Polishing System 3ESPE

Lava All-Zirconia. What about chipping? Not an issue for us. All-Zirconia Monolithic Restoration

EQUIA Forte Glass Hybrid Restorative System. For long term posterior restorations

COURSE CURRICULUM FOR AESTHETIC DENTISTRY

Postgraduate Clinic, Faculty of Dentistry, Universidad de los Andes UANDES, Las Condes, Santiago, Chile

I N F O R M A T I O N F O R D E N T I S T S. IPS e.max one system for every indication

2 (Cercon) Comparison of marginal fit in zirconia-based all-ceramic frameworks (cercon) made by two approaches (Direct and Wax-up scanning)

Grandio blocs Grandio disc. blocs disc

Empress * CAD IPS. Confidence. Reliability. Esthetics. IPS Empress CAD for the CAD/CAM Technology Information for Dentists

EFFECT OF LIGHT CURING UNIT ON RESIN-MODIFIED GLASS-IONOMER CEMENTS: A MICROHARDNESS ASSESSMENT

Dual-Curing, Self-Adhesive Resin Cement: Influence of the Polymerization Modes on the Degree of Conversion and Microhardness

Resin-bonded casting used as an anterior fixed partial denture retainer: A clinical report

Posterior Adhesive Dentistry

Bond strengths between composite resin and auto cure glass ionomer cement using the co-cure technique

Quantifying Light Energy Delivered to a Class I Restoration

Tensile bond strength of four denture resins to porcelain teeth with different surface treatment

Evaluation of bond strength of denture teeth bonded to heat polymerized acrylic resin denture bases

Evaluation of degree of conversion and hardness of dental composites photoactivated with different light guide tips

Anterior Esthetic Techniques & Materials

Evaluation of hardness and surface roughness of two maxillofacial silicones following disinfection

THE ONE AND ONLY. CLEARFIL Universal Bond

Literaturverzeichnis: 1. Tay FR, Frankenberger R, Krejci I et al. (2004) Single-bottle adhesives behave as permeable membranes after polymerization. I

One cement that can take you just about anywhere! RelyX. Unicem. Self-Adhesive Universal Resin Cement

Evaluation the Effect of Different Surface Treatment on Shear Bond Strength between Composite Increments (An in vitro study)

8 Dental Materials Journal 10 (1): 8-17, Degree of Conversion of Dual-Cured Composite Luting Cements

Bonding to dentine: How it works. The future of restorative dentistry

the new dna of high strength glass ceramics

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

Used Products. Variolink N LC. Proxyt fluoride-free. OptraStick. Ivoclean. Monobond N. OptraDam. N-Etch. Tetric N-Bond.

Bending strengths and hardness of autopolymerized acrylic resin

A Formula for Success. Lava All Zirconia. The flexibility you need. 3M All Rights Reserved.

The Effect of Soft-start Polymerization by Second Generation LEDs on the Degree of Conversion of Resin Composite

IPS Empress System Information for the. Laboratory. Confidence. Reliability. Esthetics. Empress IPS. System. The ultimate esthetic restorative system

Transcription:

Dental Materials Dental Materials Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement Nelson Tetsu Iriyama (a) (in memoriam) Rubens Nisie Tango (b) Izabella Paola Manetta (a) Mário Alexandre Coelho Sinhoreti (c) Lourenço Correr Sobrinho (c) Guilherme de Siqueira Ferreira Anzaloni Saavedra (d) (a) DDS; (c) Head Professor, Department of Restorative Dentistry Piracicaba Dental School, University of Campinas (UNICAMP), Campinas, SP, Brazil. (b) Professor, Department of Dental Materials and Prosthodontics, School of Dentistry of São José dos Campos, São Paulo State University (UNESP), São José dos Campos, SP, Brazil. (d) PhD Student, Department of Restorative Dentistry, School of Dentistry of São José dos Campos, São Paulo State University (UNESP), São José dos Campos, SP, Brazil. Abstract: This study evaluated the Knoop hardness of a dual-cured resin cement (Rely-X ARC) activated solely by chemical reaction (control group) or by chemical / physical mode, light-cured through a 1.5 mm thick ceramic (HeraCeram) or composite (Artglass) disc. Light curing was carried out using conventional halogen light (XL2500) for 40 s (QTH); light emitting diodes (Ultrablue Is) for 40 s (LED); and Xenon plasma arc (Apollo 95E) for 3 s (PAC). Bovine incisors had their buccal face flattened and hybridized. On this surface a rubber mold (5 mm in diameter and 1 mm in height) was bulk filled with the resin cement. A polyester strip was seated for direct light curing or through the discs of veneering materials. After dry storage in the dark (24 h/37 C), the samples (n = 5) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50 gf load/15 s). The data were statistically analyzed by ANOVA and Tukey s test (α = 0.05). The cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values. Descriptors: Resin cements; Hardness; Composite resins; Dental porcelain. Corresponding author: Rubens Nisie Tango Área de Materiais Dentários, Departamento de Materiais Odontológicos e Prótese, Faculdade de Odontologia de São José dos Campos, UNESP Av. Eng. Francisco José Longo, 777 São José do Campos - SP - Brazil CEP: 12245-000 E-mail: tango@fosjc.unesp.br Received for publication on Mar 29, 2007 Accepted for publication on Sep 20, 2007 108

Iriyama NT, Tango RN, Manetta IP, Sinhoreti MAC, Correr Sobrinho L, Saavedra GSFA Introduction The use of resin cements has grown in the last few years due to an increased application of esthetic indirect restorative materials such as ceramics and resin composites. As advantages, these cements present adhesion to substrates due to compatibility with silane agents and adhesive systems, low solubility, easy handling properties and favourable aesthetics when used with metal-free ceramic systems. The application of these cements can still result in higher fatigue compressive strength of all-ceramic crowns compared to glass ionomer cements and to zinc phosphate cements. 1 In spite of the variety of available cements, there is no ideal cement for all clinical situations. Therefore, the choice of the luting agent must rely on its physical, biological and manipulation properties added to the characteristics of the remainder of the prepared tooth and the prosthesis. 2 The final quality of the restoration can be influenced by factors such as light-curing method and exposure time, type of indirect restorative material and also by the luting agent. 3-5 Inlays, onlays, laminate veneers and all-ceramic crowns are commonly luted with dual-cured resin cements because light transmission through the indirect restorative is reduced, so the chemical reaction should theoretically guarantee a satisfactory degree of conversion. It has been observed that the light transmission spectrum through ceramic is influenced by its thickness, shade, and opacity. 6,7 The influence of these factors can also be observed during the cementation of laminate veneers made of indirect resin composite. 3 The application of longer light-curing times results in higher resin composite polymerization depth, higher degree of conversion and higher hardness values, 3,7 and, consequently, in improved mechanical and aesthetic properties. 8 According to Tanoue et al. 9 (2001), the same can be applied to light-cured resin cements. The hardness test is commonly used as a simple and reliable method to indirectly indicate the degree of conversion of resin cements. 10 The degree of conversion in a polymerization reaction depends on the energy supplied during light curing, characterized as the product of the light intensity and exposure time. 11 Dual-cured resin cements present higher hardness values compared to cements that are lightcured solely, 3 and light-activated dual-cured resin cements present higher hardness values compared to dual-cured resin cements polymerised chemically. 11 Witzel et al. 12 (2003) demonstrated that dual-cured resin cements, when not light-cured and associated to one-bottle adhesive systems, resulted in lower bond strength values compared to those obtained with light-cured dual activated cements. Light curing is usually performed with Quartz Tungsten Halogen light-curing units. Other recent light-curing technologies such as Xenon plasma arc (PAC) and light emitting diodes (LED) are also available. Their application is growing fast in spite of the ongoing development of these systems. Doubts about the effectiveness of light-activation of resin cements with different methods using these light-curing units still exist. The null hypotheses tested were: (1) there is no difference in the degree of cure of the resin cement promoted by different curing units; (2) there is no difference in the degree of cure obtained by means of light activation through different veneering materials and (3) the light activation mode does not influence the microhardness values of the resin cement. Material and Methods For this study a disc-shaped specimen (1.5 mm in thickness and 7 mm in diameter) was prepared for each veneering material: a feldspathic ceramic (HeraCeram, Heraeus Kulzer, Wehrhein, Germany) and an indirect resin composite (Artglass, Heraeus Kulzer, Wehrhein, Germany). In order to simulate the cementation procedures, a bovine incisor was sectioned and its coronal portion was embedded in polystyrene resin maintaining the buccal surface exposed. This surface was ground flat under water-cooling with #200, 400 and 600 grit SiC sandpapers (Saint-Gobain, Recife, PE, Brazil), to obtain a dentine area of at least 25 mm². On this surface a polyester strip was seated, and over this set a rubber mould (5 mm in diameter and 1 mm in height) was bulk filled with resin cement. The dual-cured resin cement Rely-X ARC (3M ESPE, Saint Paul, MN, USA), shade A3, was manip- 109

Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement ulated according to the manufacturer s instructions. A polyester strip was seated over this set, and with a disc of veneering material the cement was digitally compressed for excess flow and removal. Light curing was carried out with a conventional quartz tungsten halogen (QTH) light-curing unit (LCU) (XL 2500, 3M ESPE, Saint Paul, MN, USA) for 40 s at 700 mw/cm², light emitting diodes (LED) (Ultrablue Is, DMC Equip. Ltda., São Carlos, SP, Brazil) for 40 s at 440 mw/cm², and with a Xenon plasma arc (PAC) (Apollo 95E, DMD Equip. Ltd., Westlake Village, CA, USA) for 3 s at 1,600 mw/cm². As control group, the cement was set to cure by chemical reaction only. After light curing, the specimens (n = 5) were stored dry in the dark at 37 C, for 24 h. To perform resin cement Knoop hardness measurements, the samples were embedded in self-cured acrylic resin, and sectioned longitudinally under water-cooling with a diamond saw (Extec model 12205, Extec corp., Enfield, CT, USA). The surface obtained by sectioning was polished sequentially under watercooling with SiC sandpapers with # 400, 600 and 1,200 grit. Indentations and micro-hardness measurements (KHN) were performed sequentially, in a microhardness tester machine (HMV-2000, Shimadzu, Tokyo, Japan). Three indentations were performed in each depth of 100, 500 and 900 µm from the top surface, with load of 50 gf for 15 s. For each specimen, a mean hardness value was obtained from nine measurements, and the data were submitted to one-way ANOVA and to Tukey s test at the 5% level of significance. Results ANOVA showed statistically significant differences among the groups (p < 0.05). Tukey s test showed that the resin cement presented higher Knoop hardness values with Artglass for QTH and LED, compared to HeraCeram. The control group and the PAC/Artglass group showed lower hardness values compared to the groups light-cured with QTH and LED. PAC/HeraCeram resulted in the worst combination for cement hardness values (Table 1). Discussion According to the results (Table 1), the null hypotheses of this study were rejected. The results (Table 1) showed that lower hardness values were obtained when the resin cement Rely-X was light-cured with PAC compared to QTH and LED. Light curing with QTH and LED resulted in similar hardness values. This behaviour might be due to the short exposure time during light-curing with PAC, 13,14 that resulted in a low energy density supplied to the resin cement. This lower energy leads to a lower degree of conversion of the cement, which is determined indirectly by hardness values measurements. 15 It can be hypothesised that with an increase in light-curing exposure time, hardness values similar to those produced by QTH and LED would be obtained. The results of this study are in agreement with those of Rasetto et al. 5 (2001). On the other hand, Ozyesil et al. 16 (2004) observed similar degrees of conversion for the resin cement Variolink II light-cured with conventional QTH and PAC. The veneering material also influenced resin cement hardness. Higher hardness values were observed with Artglass compared to HeraCeram (Table 1). This might be the result of the different nature of these materials, which entails distinct optical characteristics. It was not possible to compare these results with those reported in the literature because studies using this methodology were not found. Light curing with PAC through HeraCeram resulted in the lowest hardness values, even when compared Table 1 - Comparison of the Knoop hardness values (KHN) (SD) of the resin cement polymerized under different conditions. Treatment QTH/Artglass LED/Artglass QTH/HeraCeram LED/ HeraCeram Chemical PAC/Artglass PAC/HeraCeram KHN (SD) 51.76 (5.01) a 51.50 (4.11) a 45.35 (6.04) b 44.47 (4.90) b 28.47 (2.99) c 26.26 (4.93) c 21.82 (3.81) d Means followed by different letters are significantly different by the Tukey test (p < 0.05). 110

Iriyama NT, Tango RN, Manetta IP, Sinhoreti MAC, Correr Sobrinho L, Saavedra GSFA to those of solely chemical-cured cement (Table 1). It could be supposed that the light scattering and refracting determined by HeraCeram would be higher compared to that of Artglass. The lower values observed for PAC could be the result of the light attenuation produced by the veneering materials, and by the resin cement per se. 17 Another hypothesis was that light curing with PAC through HeraCeram induced an initiation of the polymerization reaction characterised by cross-linking formation. It could have reduced monomer mobility in the mass bulk, thus decreasing polymerization complementation by the chemical-cure. 18 According to Soh, Yap, 18 in 2004, light curing with high intensity would lead to a highly cross-linked polymer chain, and to higher hardness. In regions submitted to low energy density, the polymer chain would be more linear with higher mobility, and lower hardness values. Cementation using dual-cured resin cements has been indicated due to the presence of chemical initiators that would, theoretically, guarantee a reliable cement polymerization even with a deficient lightcuring. 19 Peutzfeldt 20 (1995) observed that the best mechanical properties of the dual-cured cements were obtained with light curing, avoiding the polymerization reaction by chemical curing alone. Further studies are necessary on the veneering materials characteristics, and on the search for reasonable light-curing exposure times with PAC for dual-cured cement polymerization. Conclusions Based on the results obtained in the present investigation, it could be concluded that: 1. Higher hardness values were obtained with QTH and LED, compared to PAC and the chemicalcured group. 2. Light curing through Artglass resulted in higher hardness values compared to HeraCeram. 3. Light curing with PAC for just 3 s negatively influenced resin cement hardness. References 1. Groten M, Probster L. The influence of different cementation modes on the fracture resistance of feldspathic ceramic crowns. Int J Prosthodont. 1997;10(2):169-77. 2. Rosenstiel SF, Land MF, Crispin BJ. Dental luting agents: a review of the current literature. J Prosthet Dent. 1998;80(3):280-301. 3. Breeding LC, Dixon DL, Caughman WF. The curing potential of light-activated composite resin luting agents. J Prosthet Dent. 1991;65(4):512-8. 4. Rahiotis C, Kakaboura A, Loukidis M, Vougiouklakis G. Curing efficiency of various types of light-curing units. Eur J Oral Sci. 2004;112(1):89-94. 5. Rasetto FH, Driscoll CF, von Fraunhofer JA. Effect of light source and time on the polymerization of resin cement through ceramic veneers. J Prosthodont. 2001;10(3):133-9. 6. O Keefe KL, Pease PL, Herrin HK. Variables affecting the spectral transmittance of light through porcelain veneer samples. J Prosthet Dent. 1991;66(4):434-8. 7. Uctasli S, Hasanreisoglu U, Wilson HJ. The attenuation of radiation by porcelain and its effect on polymerization of resin cements. J Oral Rehabil. 1994;21(5):565-75. 8. Watts DC, Cash AJ. Analysis of optical transmission by 400-500 nm visible light into aesthetic dental biomaterials. J Dent. 1994;22(2):112-7. 9. Tanoue N, Koishi Y, Matsumura H, Atsuta M. Curing depth of different shades of a photo-activated prosthetic composite material. J Oral Rehabil. 2001;28(7):618-23. 10. Darr AH, Jacobsen PH. Conversion of dual cure luting cements. J Oral Rehabil. 1995;22(1):43-7. 11. Rueggeberg FA, Caughman WF, Curtis JW Jr. Effect of light intensity and exposure duration on cure of resin composite. Oper Dent. 1994;19(1):26-32. 12. Witzel MF, Braga RR, Singer JM, Azevedo CL. Bond strength between polymer resin-based cement and porcelain-dentin surfaces: influence of polymerization mode and early cyclic loading. Int J Prosthodont. 2003;16(2):145-9. 13. Deb S, Sehmi H. A comparative study of the properties of dental resin composites polymerized with plasma and halogen light. Dent Mater. 2003;19(6):517-22. 14. Jung H, Friedl KH, Hiller KA, Haller A, Schmalz G. Curing efficiency of different polymerization methods through ceramic restorations. Clin Oral Investig. 2001;5(3):156-61. 15. Sharkey S, Ray N, Burke F, Ziada H, Hannigan A. Surface hardness of light-activated resin composites cured by two different visible-light sources: an in vitro study. Quintessence Int. 2001;32:401-5. 16. Ozyesil AG, Usumez A, Gunduz B. The efficiency of different light sources to polymerize composite beneath a simulated ceramic restoration. J Prosthet Dent. 2004;91(2):151-7. 111

Effect of light-curing method and indirect veneering materials on the Knoop hardness of a resin cement 17. Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G, Ristic M. Photopolymerization of composite resins with plasma light. J Oral Rehabil. 2002;29(8):782-6. 18. Soh MS, Yap AU. Influence of curing modes on crosslink density in polymer structures. J Dent. 2004;32(4):321-6. 19. Kramer N, Lohbauer U, Frankenberger R. Adhesive luting of indirect restorations. Am J Dent. 2000;13(Spec No):60D- 76D. 20. Peutzfeldt A. Dual-cure resin cements: in vitro wear and effect of quantity of remaining double bonds, filler volume, and light curing. Acta Odontol Scand. 1995;53(1):29-34. 112