Ilser Turkyilmaz Lars Sennerby Celal Tumer Muhittin Yenigul Mehmet Avci

Similar documents
NobelReplace Conical Connection Product overview

While the protocol for direct bone-to-implant

The Brånemark osseointegration method, using titanium dental implants (fixtures)

NobelActive Product overview

Resonance Frequency Analysis Measurements of Implants at Placement Surgery

Hiron Andreaza da Cunha, MS 1 /Carlos Eduardo Francischone, DMD 2 /Hugo Nary Filho, DDS 3 / Rubelisa Cândido Gomes de Oliveira, BDS 4

The Importance of Implant Surface Characteristics in the Replacement of Failed Implants

Osseointegrated dental implant treatment generally

Proven stability, high esthetics NobelReplace Conical Connection

Endosseous dental implants initially showed very

Brånemark System Facts & Figures

Case study 2. A Retrospective Multi-Center Study on the Spiral Implant

NobelActive Inventor s perspective on this new direction for implants

Direct Implant Loading in the Edentulous Maxilla Using a Bone Density Adapted Surgical Protocol and Primary Implant Stability Criteria for Inclusion

Comparative Evaluation of Bone in Mandibular Implant Retained Overdentures Using Delayed and Immediate Loading Protocol: An In-Vivo Study

Influence of Patient Age on the Success Rate of Dental Implants Supporting an Overdenture in an Edentulous Mandible: A 3-year Prospective Study

During the last 30 years, endosseous oral

There are many longitudinal investigations

A STUDY ON THE CORRELATION BETWEEN IMPLANT STABILITY VALUES AND INITIAL INSERTION TORQUE

Mandibular Implant-Retained Overdentures with two Different Implant Designs. Ibrahim R. Eltorky

Annals of Dental Research

The majority of the early research concerning

Simply straightforward NobelParallel Conical Connection

CHAPTER 1. General Introduction

Implant Restorations: A Step-By-Step Guide

Proven stability, high esthetics NobelReplace Conical Connection

Mechanical and technical risks in implant therapy.

Brånemark System Facts & Figures

Radiographic Stent for Simplified Placement of Implants in the Mandible

Implant osseointegration and successful restoration

Clinical Perspectives

Conus Concept: A Rewarding Complete Denture Treatment

Bone Reduction Surgical Guide for the Novum Implant Procedure: Technical Note

Immediate Loading of Implants with 3-unit Fixed Partial Dentures: A 12-month Clinical Study

Many of the problems reported by conventional

10 Years of XiVE Implantology Unlimited

(Please note that Abstracts, reviews, case reports, technique descriptions, animal and in vitro tests are excluded)

THE PERIODONTAL ASPECT OF IMPLANT THERAPY Prof. Dr. Windisch Péter

The Use of Alpha-Bio Tec's Narrow NeO Implants with Cone Connection for Restoration of Limited Width Ridges

Implant Placement in Maxillary Anterior Region Along with Soft and Hard Tissue Grafting- A Case Report.

Implant survival, bone remodeling and implant stability of Neoss implants: a systematic review of the literature

CHAPTER 7. General Discussion

A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis

The use of endosseous implants is currently a routine

Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible

Assessment of Implant Stability of Two-piece Zirconium Dioxide Implants using the Resonance Frequency Analysis: A Pilot Study

NobelParallel Conical Connection Product overview

Enhanced Implant Stability with a Chemically Modified SLA Surface: A Randomized Pilot Study

A retrospective study on separate single-tooth implant restorations to replace two or more consecutive. maxillary posterior teeth up to 6 years.

EFFECT OF IMPLANT DESIGN ON INITIAL STABILITY

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

An Introduction to Dental Implants

Evaluation of INNO TM dental Implants placed with high insertion torques (Up to 135 Ncm)

Survival Analysis of Endosseous Implants in Grafted and Nongrafted Edentulous Maxillae

Dental Research Journal

BIOMECHANICS AND OVERDENTURES

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

The Self-tapping and ICE 3i Implants: A Prospective 3-Year Multicenter Evaluation

A novel technique for fabrication of immediate provisional restorations

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

1- Implant-supported vs. implant retained distal extension mandibular partial overdentures and residual ridge resorption. Abstract Purpose: This

The Use Of 6mm Long Implants In Cases With Limited Bone Height: A Preliminary 6-Month Clinical Study

GuidedService. The ultimate guide for precise implantations

Case study 40. Use of narrow implants for restoration of missing anterior teeth. Dr. Amir Gazmawe

The restoration of partially and completely

Objectives: The purpose of this investigation was to evaluate the effects of different

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

Implant treatment in patients with severely

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

Narrow-diameter implants in premolar and molar areas

Social changes, evolution in dentistry, and changes

John P. Zarb, BA, DDS George A. Zarb, BChD, DDS, MS, MS, FRCD(C)

The long-term success of osseointegrated dental

Using immediate implant placement to address aesthetic and biomechanical challenges: A clinical presentation

Rehabilitation of an Edentulous Patient with Implant Supported Overdenture

surgical and prosthetic options & impression technique overview

Consequences of insufficient treatment planning for flapless implant surgery for a mandibular overdenture: A clinical report

Locator retained mandibular complete prosthesis (isy Implant System)

AO Certificate in Implant Dentistry Certificate

Citation for published version (APA): Hoeksema, A. (2016). Oral health in frail elderly [Groningen]: Rijksuniversiteit Groningen

The Implant Stability Quotient Whitebook. The relationship between reliable diagnostics and safe, successful dental implant procedures 1 st edition

A retrospective clinical study of single short implants (less than 8 mm) in posterior edentulous areas

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Since the report of Adell and associates, 1 well-documented

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

Rehabilitation of a Patient with Completely Edentulous Maxillary Arch using All on 4 Concept of Implantation

INCREASED RETENTION OF A PARTIAL DENTURE MAXILLARY OBTURATOR USING DENTAL IMPLANT

Consensus Report Tissue augmentation and esthetics (Working Group 3)

Areview of recent studies concerning molar. Single Molar Replacement with a Progressive Thread Design Implant System: A Retrospective Clinical Report

An evaluation of TimPlant using Osstell: A device for non-invasive assessment of dental implants stability

A new approach with an in-situ self-hardening grafting material

Implant-based fixed rehabilitation of

Replace Facts & Figures

MULTIDIRECTIONAL APPROACH OF ORAL REHABILITATION WITH IMPLANTS IN A PATIENT WITH LIMITED MOUTH OPENING: A CASE REPORT

Retrospective Cohort Study of the Clinical Performance of 1-Stage Dental Implants

Assessment of Osstellä and Periotest Ò systems in measuring dental implant stability (in vitro study)

Since the introduction of osseointegrated dental implants

Prosthetic RehabilitationofaPatientwithAlzheimersDiseaseusingaCombinedBallBarandClipRetainedImplantSupportedOverdentureA Case Report

SCD Case Study. Implant-supported overdentures

The severely resorbed edentulous maxilla presents

Transcription:

Ilser Turkyilmaz Lars Sennerby Celal Tumer Muhittin Yenigul Mehmet Avci Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols Authors affiliations: Ilser Turkyilmaz, Muhittin Yenigul, Mehmet Avci, Department of Prosthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey Celal Tumer, Department of Oral & Maxillofacial Surgery, Faculty of Dentistry, Hacettepe University, Ankara, Turkey Ilser Turkyilmaz, Lars Sennerby, Department of Biomaterials, Institute of Surgical Sciences, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden Correspondence to: Dr Ilser Turkyilmaz Department of Biomaterials Institute of Surgical Sciences Sahlgrenska Academy Gothenburg University PO Box 412 SE 45 3 Gothenburg Sweden Tel.: þ 46 31 773 29 5 Fax: þ 46 31 773 29 41 e-mail: ilser@hacettepe.edu.tr Key words: early loading, mandibular overdentures, marginal bone resorption, resonance frequency analysis Abstract Objectives: The aim of this study was to compare the performance of two non-splinted implants used as retention for a mandibular overdenture when applying conventional or early loading protocols. Material and methods: Twenty edentulous patients were treated with two unsplinted and non-submerged implants (15 mm long, TiUnite RP, Brånemark System) in the anterior mandible. The patients were randomly allotted into two groups: (i) test group (Group A), in which the overdenture was connected 1 week after surgery, and (ii) control group (Group B), in which the overdenture was connected after 12 weeks of healing. Resonance frequency analyses (RFA) for implant stability measurements were performed at implant surgery and after 1, 3, 6, 9 and 12 months. Marginal bone levels were evaluated at implant surgery and after 6 and 12 months. Results: No implant from either group was lost and all implants showed less than 1 mm of marginal bone resorption during the first year. The mean implant stability quotient (ISQ) values at implant surgery were 76.2 2.8 for Group A and 75.6 4.5 for Group B. The 12-month measurements showed 76.4 2.5 ISQ and 76.4 2.8 ISQ for Groups A and B, respectively. There were no statistically significant changes between or within the groups with time. There were no differences in marginal bone loss, which was on average.3 mm for both groups after 1 year. Conclusion: Although a limited number of patients were followed for 1 year only, the results of the present study indicate that early loading of two unsplinted 15 mm long implants with an overdenture does not negatively affect implant stability or marginal bone conditions when compared with implants subjected to 12 weeks of healing before loading. Date: Accepted 3 November 25 To cite this article: Turkyilmaz I, Sennerby L, Tumer C, Yenigul M, Avci M. Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols. Clin. Oral Impl. Res. 17, 26; 51 55 doi: 1.1111/j.16-51.26.1261.x Copyright r Blackwell Munksgaard 26 Clinical follow-up studies have reported good and predictable long-term treatment outcomes with implant-supported mandibular overdentures (van Steenberghe et al. 21; Behneke et al. 22; Zechner et al. 24). The use of two to four or more implants connected with a bar seems to dominate the literature, although the use of two unsplinted implants has been reported to be a feasible option (Naert et al. 24). Advantages with the latter technique are simplicity and less costs, as the full treatment can be made chair side without any laboratory procedures. This treatment modality has been proposed to be the minimal acceptable standard of care of the edentulous mandible (Thomason 22). The use of one-stage surgical procedures and immediate/early loading protocols is one way of further simplifying implant treatment. The outcomes of early loading protocols for splinted implants supporting 51

mandibular overdentures have been reported in the literature (Chiapasco et al. 1997; Collaert & De Bruyn 1998). Only a few studies have dealt with early loading of unsplinted implants supporting mandibular overdentures (Payne et al. 21; Rynesdal et al. 21), and no trials comparing different loading regimens are available. It is possible that non-splinted implants may be negatively affected by immediate/early loading because the load is not shared between implants, i.e. decreased stability and/or marginal bone resorption. The aim of this prospective clinical study was to compare implant stability and marginal bone resorption when using conventional or early functional loading protocols in patients rehabilitated with implant-supported mandibular overdentures. Material and methods Patients Twenty totally edentulous patients (1 males, 1 females, mean age 62 years) with a history of problems with their conventional mandibular and maxillary complete dentures presenting at the Clinical Overdenture Research Project (Faculty of Dentistry, University of Hacettepe, Ankara, Turkey) were considered for the clinical trial. Ethical approval was obtained from Hacettepe University Ethics Committee, and all participants gave informed consent. Inclusion criteria (a) (b) Fifty to 75 years old. Bone volume for two 15 mm implants in the anterior mandible. Exclusion criteria (a) (b) Systemic disease likely to compromise implant surgery. Previously bone grafting in the anterior part of the mandible. Preoperative panoramic radiograph (Planmeca OY, Helsinki, Finland) and computerized tomograpy (Siemens AR-SP 4, Munich, Germany) were used for surgical evaluation of the selected sites for each patient. Surgical and prosthodontic procedures Antimicrobial prophylaxis (2 g amoxicillin) was given orally 1 h before each surgery. The patients were rinsed with chlorhexidine digluconate solution (.2%) for 1 min 1 min before the operation. Local anaesthesia was induced by infiltration of Ultracaine s D-S (Hoechst Marion Roussel, Deutschland GmbH, Germany) buccally and lingually of the canine regions in the mandible. A mid-crestal incision was made in keratinized mucosa and a small flap was raised at each site to expose the bone. The sites were prepared according to the standard procedure for Brånemark System implants (Nobel Biocare AB). Two 15 mm implants (TiUnite RP MKIII, Nobel Biocare AB) were placed in each patient. The patients were randomly allocated into two groups. Group A Ball attachments (3 mm, Nobel Biocare AB) were screwed to the implants before suturing. Mucoperiosteal flap closure was performed using interrupted or horizontal mattress sutures (4- Vicryl s, Ethicon, Johnson& Johnson, Brussels, Belgium). The patients were prescribed a soft diet for the first week and a strict regimen of removal of their old dentures during night. Five days after surgery, the sutures were removed and preliminary impressions were taken with a stok tray using alginate (Caex, CA37, Haarlem, the Netherlands). Secondary impressions were taken with a custom-made tray using Coltex Medium impression materials (Coltene/Whaledent AG Feldweisenstrasse 2, Altstatten, Switzerland). The ball abutment replicas were placed into the impression material after the impression was removed. Wax occlusal rims were created on the master models for try-in the same day. Teeth try-in (Major Dent, Moncalieri, Italy) and corrections and manufacturing of the acrylic dentures (Meliodent, Heraeus Kulzer Ltd, Newbury, Berkshire, Germany) were performed on the sixth day after surgery. The maxillary complete denture and implant tissuesupported mandibular overdentures with respective gold caps were delivered to the participants 1 week after the implant surgery. Group B Healing abutments (5 mm) were attached to the implants. New maxillary and mandibular complete dentures were manufactured as described above and delivered 1 week after the implant surgery. However, care was taken to ensure that the mandibular denture did not contact the implants. After 3 months of healing the healing abutments were replaced with ball attachments (3 mm). A reline impression procedure was performed and the implant tissue-supported mandibular overdenture was delivered the next day. Follow-up Clinical examinations and resonance frequency analysis (RFA) (Osstell, Integration Diagnostics AB, Gothenburg, Sweden) were performed at implant surgery and after 1, 3, 6, 9 and 12 months. On these occasions, the abutments were removed from the patient and RFA measurements were taken on implant level. The measurements were given in implant stability quotient (ISQ) units (Integration Diagnostics AB). Standardized intraoral radiographs of the coronal parts of the implants were taken at implant placement after 6 and 12 months. On these occasions an impression coping was attached to each implant to guide a plastic film holder. The radiographs were scanned to digital files and marginal bone changes were measured in a computer using an image analysis software (Adobe Photoshop, Adobe Systems Incorporated, San Jose, CA, USA) by one examiner using the implant abutment junction as a reference (Payne et al. 1999). The distance between two threads (.6 mm) was used for calibration of measurements. The success criteria were absence of mobility and less than 1 mm of marginal bone resorption between placement and 1 year. The survival criterion was a stable implant showing more than 1 mm of bone resorption after 1 year. Implants removed for any reason were regarded as failures. Statistics All data were analysed with SPSS version 1 statistical package (SPSS Inc., Chicago, IL, USA). Statistical tests were made on patient level, meaning that mean ISQ and marginal bone level values were calculated for each patient based on two implants. The Spearman correlation test was used to find possible relations between RFA and marginal bone resorption. A difference was considered if Po.5. Results The mean ISQ values at implant surgery were 76.2 2.8 for Group A and 75.6 52 Clin. Oral Impl. Res. 17, 26 / 51 55

4.5 for Group B (NS) (Table 1). There was a tendency of higher ISQ values for Group A during follow-up, however with no significant differences (Fig. 1). There were no statistically significant changes within the groups with time. The 12-month measurements showed 76.4 2.5 ISQ and 76.4 2.8 ISQ for Groups A and B, respectively (NS) (Table 1). In Group A, the marginal bone was located.7.3 mm from the reference point immediately after implant placement,.8.3 mm after 6 months and 1.3 mm after 12 months. The corresponding figures for Group B were.6.2 mm at baseline and.8.2 and.9.3 mm after 6 and 12 months, respectively (Table 2). Thus the average marginal bone resorption was.3 mm for both groups during 1 year. There were no statistical significant differences between the two groups. There was a statistically significant correlation between change of stability and marginal bone resorption from baseline to 6 months (Fig. 2) but not from 6 to 12 months (Fig. 3) based on measurements of all patients (n ¼ 2). All implants were stable and no single implant showed more than 1 mm of bone resorption after 1 year; thus, all 4 implants were judged as successful. Discussion The present study showed that one-stage surgery is feasible when using two unsplinted implants as support for an overdenture in the mandible as no implants were lost during the 1-year follow-up period. The implant stability and marginal bone-level measurements showed no differences between implants loaded 1 week or 3 months after surgery, indicating that early loading did not negatively influence the performance of the implants. When validating an implant treatment approach, the use of well-defined criteria for success is essential. The absence of implant mobility and set levels of acceptable marginal bone resorption have commonly been utilized (Roos et al. 1997). In the present study, all implants were individually checked for stability using the RFA technique and marginal bone levels were measured. No implant failed and all 4 Table 1. Results from RFA measurements Mean ISQ þ SD Surgery Month 1 Month 3 Month 6 Month 9 Month 12 Group A 76.2 2.8 75.6 2.2 75 2.6 75.2 3.4 76 2.8 76.4 2.5 Group B 75.6 4.5 73.2 3.4 73 3.6 74.1 3.6 74.7 3.1 76.4 2.8 RFA, resonance frequency analyses; ISQ, implant stability quotient. 7 6 5 4 3 2 1 1 2 3 4 5 6 7 1 2 3 4 5 6 implants in this study showed less than 1 mm of resorption, meaning that the success rate after 1 year was 1% in spite of if conventional or early loading protocols were applied. The present 1-year results corroborate with the results reported in other studies on mandibular overdentures when using 3 months and 6 weeks of healing before loading (Jemt et al. 1996; Schmitt & Zarb 1998; Tawse- Smith et al. 22; Payne et al. 23; Naert et al. 24). This is most encouraging and indicates that early loading of two unsplinted implants is a safe procedure, which will further simplify an already effective and recognized treatment modality of the edentulous mandible (Thomason 22). Group A Group B Fig. 1. Change of implant stability with time in Groups A and B. A tendency of steeper decrease is seen for Group B implants; however, this is not statistically significant. Table 2. Results from radiographic measurements Mean mm þ SD Surgery Month 6 Month 12 Change 6 months Change 12 months Change 6 12 months Group A.7.3.9.3 1.3.2.2.3.2.1.1 Group B.6.2.8.2.9.2.2.2.3.1.1.1 All implants used in this study were placed in the anterior mandible, where bone density is high compared with other regions (Friberg et al. 1995). High bone density results in high primary stability (Friberg et al. 1999a, 1999b; O Sullivan et al. 2), which is considered as one important determinant of success (Sennerby & Roos 1998). RFA showed an average primary stability of about 75 ISQ units, which is in line with ISQ values reported for similar implant designs by other researchers (Payne et al. 23). The ISQ values decreased slightly during the initial quarter following surgery and increased from the third month to the 12th month measurements. This is in line with the findings reported by Friberg et al. 53 Clin. Oral Impl. Res. 17, 26 / 51 55

Marginal bone resorption (mm) 1 8 6 4 2 2 4 6.1 (1999a, 1999b) who made repeated measurements of one-stage implants in the mandible during 15 weeks of healing. They also found some marginal bone resorption during that period which could explain the decrease, as RFA measurements are affected by the effective implant length, i.e. the distance from the RFA transducer to the first bone contact (Meredith et al. 1996, 1997). In the present study there was a correlation between change of stability and marginal bone resorption from baseline to 6 months but not from 6 to 12 months. This decrease could be explained in terms of increased effective implant length and indicates that bone formation had no impact on implant stability during the first 6 months, as this.3.2.1.2.3.4.5 Fig. 2. Correlation plot between change of stability (implant stability quotient (ISQ)) and marginal bone resorption (mm) from baseline to 6 months. There is a statistically significant correlation (Po.1). Marginal bone resorption (mm).2.1 2 2 4 6 8.1.2.3.4.5 Fig. 3. Correlation plot between change of stability (implant stability quotient (ISQ)) and marginal bone resorption (mm) from 6 to 12 months. A statistically significant correlation cannot be found. would have counteracted the effect of resorption. However, after 6 months it seems that bone formation did affect implant stability positively and thus counteracted the effect of bone resorption. In a study by Glauser et al. (24), the authors observed a marked decrease of implant stability during the first months in spite of minimal marginal bone resorption. The greater fluctuations of implant stability compared with the present study can be explained by the greater loads applied by Glauser et al. as the implants were used to support crowns and bridges in all jaw regions. Apart from effective implant length, the RFA technique meaures stability as a function of interface stiffness. It is likely that loading affects healing and remodelling around implants, which in turn influences the mechanical properties of the supporting bone. However, the correlation between histomorphometric parameters such as bone-to-implant contacts/bone volume and RFA is presently unclear and more studies are needed (Nkenke et al. 23). In the study referred to above, Glauser et al. (24) demonstrated that implants failing during the 1-year study period showed a pattern of continuous loss of stability until clinical failure. The available data indicate that RFA may serve as a sensitive tool to monitor the performance of clinical implants. The implants used in this study had oxidized surfaces. It is known from clinical and experimental studies that such implants integrate more rapidly and with higher degrees of bone implant contacts than machined implants (Ivanoff et al. 23; Zechner et al. 23). Although implants with machined surface are known to be highly successful in the anterior mandible using a two-stage procedure, early loading may challenge the integration process. A recent study on 152 patients and 75 implants showed lower survival rates for early loaded than for two-stage machined implants when using the implant as unit for statistical analysis (Friberg et al. 25). Oxidized implants have been shown to be more resistant to immediate loading than machined ones, at least in soft maxillary bone (Glauser et al. 21), and it is possible that the use of oxidized implants in the present study contributed to the good outcome. Although a limited number of patients were followed for 1 year only, the results of the present study indicate that early loading of two unsplinted 15 mm long implants with an overdenture does not negatively affect implant stability or marginal bone conditions when compared with implants subjected to 12 weeks of healing before loading. Acknowledgements: The authors thank Nobel Biocare AB (No. S-562; 11.11.22) and Integration Diagnostics AB, Goteborg, Sweden and Department of Scientific Research, Hacettepe University, Ankara, Turkey for their support of this study. 54 Clin. Oral Impl. Res. 17, 26 / 51 55

References Behneke, A., Behneke, N. & d Hoedt, B. (22) A 5- year longitudinal study of the clinical effectiveness of ITI solid-screw implants in the treatment of mandibular edentulism. International Journal of Oral & Maxillofacial Implants 17: 799 81. Chiapasco, M., Gatti, C., Rossi, E., Haefliger, W. & Markwalder, T.H. (1997) Implant-retained mandibular overdentures with immediate loading: a retrospective multicenter study on 226 consecutive cases. Clinical Oral Implants Research 8: 48 57. Collaert, B. & De Bruyn, H. (1998) Comparison of branemark fixture integration and shortterm survival using one-stage or two-stage surgery in completely and partially edentulous mandibles. Clinical Oral Implants Research 9: 131 135. Friberg, B., Henningsson, C. & Jemt, T. (25) Rehabilitation of edentulous mandibles by means of turned Brånemark system implants after onestage surgery: a 1-year retrospective study of 152 patients. Clinical Implant Dentistry and Related Research 7: 1 9. Friberg, B., Sennerby, L., Linden, B., Gröndahl, K. & Lekholm, U. (1999a) Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study. International Journal of Oral and Maxillofacial Surgery 28: 266 272. Friberg, B., Sennerby, L., Meredith, N. & Lekholm, U. (1999b) A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 2-month clinical study. International Journal of Oral and Maxillofacial Surgery 28: 297 33. Friberg, B., Sennerby, L., Roos, J. & Lekholm, U. (1995) Identification of bone quality in conjunction with insertion of titaniumimplants. A pilot study in jaw autopsy specimens. Clinical Oral Implants Research 6: 213 219. Glauser, R., Portmann, M., Ruhstaller, P., Lundgren, A.K., Hämmerle, C.H.F. & Gottlow, J. (21) Stability measurements of immediately loaded machnied and oxidized implants in the posterior maxilla. A comparative clinical study using resonance frequency analysis. Applied Osseointegration Research 2: 27 29. Glauser, R., Sennerby, L., Meredith, N., Ree, A., Lundgren, A., Gottlow, J. & Hämmerle, C.H. (24) Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants. Clinical Oral Implants Research 15: 428 434. Ivanoff, C.J., Widmark, G., Johansson, C. & Wennerberg, A. (23) Histologic evaluation of bone response to oxidized and turned titanium microimplants in human jawbone. International Journal of Oral & Maxillofacial Implants 18: 341 348. Jemt,T.,Chai,J.,Harnett,J.,Heath,M.R.,Hutton, J.E.,Johns,R.B.,McKenna,S.,McNamara,D.C., van Steenberghe, D., Taylor, R., Watson, R.M. & Herrmann, I. (1996) A 5-year prospective multicenter follow-up report on overdentures supported by osseointegrated implants. International Journal of Oral & Maxillofacial Implants 11: 291 298. Meredith, N., Alleyne, D. & Cawley, P. (1996) Quantitative determination of the stability of the implanttissue interface using resonance frequency analysis. Clinical Oral Implants Research 7: 261 267. Meredith, N., Book, K., Friberg, B., Jemt, T. & Sennerby, L. (1997) Resonance frequency measurements of implant stability in vivo. A crosssectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clinical Oral Implants Research 8: 226 233. Naert, I., Alsaadi, G., van Steenberghe, D. & Quirynen, M. (24) A 1-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome. International Journal of Oral & Maxillofacial Implants 19: 695 72. Nkenke, E., Hahn, M., Weinzierl, K., Radespiel- Troger, M., Neukam, F.W. & Engelke, K. (23) Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clinical Oral Implants Research 14: 61 69. O Sullivan, D., Sennerby, L. & Meredith, N. (2) Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clinical Implant Dentistry and Related Research 2: 85 92. Payne, A.G.T., Solomons, Y.F. & Lownie, J.F. (1999) Standardization of radiographs for mandibular implant-supported overdentures: review and innovation. Clinical Oral Implants Research 1: 317 319. Payne, A.G.T., Tawse-Smith, A., Duncan, W.J. & Kumara, R. (23) Conventional early loading of unsplinted ITI implants supporting mandibular overdentures: two-year results of a prospective randomized clinical trial. Clinical Oral Implants Research 13: 63 69. Payne, A.G.T., Tawse-Smith, A., Kumara, R. & Thomson, W.M. (21) One-year prospective evaluation of the early loading of unsplinted conical Brånemark fixtures with mandibular overdentures immediately following surgery. Clinical Implant Dentistry and Related Research 3: 9 19. Roos, J., Sennerby, L., Lekholm, U., Jemt, T., Gröndahl, K. & Albrektsson, T. (1997) A qualitative and quantitative method for evaluating implant success: a 5-year retrospective analysis of the Branemark implant. International Journal of Oral & Maxillofacial Implants 12: 54 514. Rynesdal, A.K., Amundrud, B. & Hannaes, H.R. (21) A comparative clinical investigation of 2 early loaded ITI dental implants supporting an overdenture in the mandible. International Journal of Oral & Maxillofacial Implants 16: 246 251. Schmitt, A. & Zarb, G.A. (1998) The notion of implant-supported overdentures. Journal of Prosthetic Dentistry 79: 6 65. Sennerby, L. & Roos, J. (1998) Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. International Journal of Prosthodontics 11: 48 42. Tawse-Smith, A., Payne, A.G.T., Kumara, R. & Thomson, W.M. (22) Early loading on unsplinted supporting mandibular overdentures using a one-stage operative procedure with two different implant systems: a 2-year report. Clinical Implant Dentistry & Related Research 4: 33 42. Thomason, J.M. (22) The McGill consensus statement on overdentures. Mandibular 2-implant verdentures as first choice standard of care for edentulous patients. European Journal of Prosthodontics and Restorative Dentistry 1: 95 96. van Steenberghe, D., Quirynen, M., Naert, I., Maffei, G. & Jacobs, R. (21) Marginal bone loss around implants retaining hinging mandibular overdentures, at 4-, 8- and 12-years follow-up. Journal of Clinical Periodontology 28: 628 633. Zechner, W., Tangl, S., Furst, G., Tepper, G., Thams, U.,Mailath,G.&Watzek,G.(23)Osseoushealing characteristics of three different implant types. Clinical Oral Implants Research 14: 15 157. Zechner, W., Trinkl, N., Watzek, G., Busenlechner, D., Tepper, G., Haas, R. & Watzek, G. (24) Radiologic follow-up of peri-implant bone loss around machine-surfaced and rough-surfaced interforaminal implants in the mandible functionally loaded for 3 to 7 years. International Journal of Oral & Maxillofacial Implants 19: 216 221. 55 Clin. Oral Impl. Res. 17, 26 / 51 55