PCR Starter Kit. For 3 32-well blocks, 0.2 ml USER GUIDE USER GUIDE. Part. No Revison B

Similar documents
PCR Starter Kit. For 96-well blocks, 0.2 ml USER GUIDE USER GUIDE. Part. No. A24829 Revison B

PCR Starter Kit. For MiniAmp and MiniAmp Plus PCR systems USER GUIDE USER GUIDE. Part. No Revison C.0

User Bulletin 7500 Fast Precision Plate Holder for MicroAmp Tube Strips

MagniSort Human CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Mouse CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Human CD4 Memory T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Mouse CD4 Naive T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Fibrlok II 2529 Universal Optical Fiber Splice

Human IL-2 Uncoated ELISA Catalog Number: Also known as: Interleukin-2 RUO: For Research Use Only. Not for use in diagnostic procedures.

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

Fibrlok II 2529 Universal Optical Fiber Splice

Adalimumab (Humira TM ) ELISA

Page 1 of 2. Product Information Contents: ezkine Th1 Activation 2 Whole Blood Intracellular Cytokine Kit

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

Instructions. Fibrlok Optical Fiber Splicing System. Issue 6, August 1991

Instructions. Fibrlok II Optical Fiber Splicing System. Issue 1, June 1992

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises.

Sharps Container (not included) 1 Gather and check supplies. Gather supplies

Page 1 of 2. Product Information Contents: Human CCL4 (MIP-1 beta) Uncoated ELISA

SelectTech 4.1 Bench Assembly / Owner s Manual

Human PYY ELISA Kit USER GUIDE

Quantity in. Unit of Measure. (If Applicable) 1 each Anode Buffer Reservoir Jar 1 Applied Biosystems $101.65

USER MANUAL Rev. 1.15

Exo-spin Blood Exosome Purification Kit For blood sera/plasma

Owner s Manual & Exercise Guide

E. SelectTech 5.1 Bench Owner s / Assembly Manual

RealLine Mycoplasma genitalium Str-Format

USER S MANUAL QUESTIONS? CAUTION. Visit our website at.

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

EnzChek Myeloperoxidase (MPO) Activity Assay Kit

E. SelectTech 3.1 Bench Assembly / Owner s Manual

Rhino Clear Sprint Atomizer

weight.detach/bench ITEM NO: 76310

USER S MANUAL QUESTIONS? CAUTION. For a great selection of new CD and MP3 workouts. Visit our website at. or call

limbsandthings.com Advanced Female Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

COR. Precision Targeting Cartilage Repair System. Arthroscopic Technique for Repair of Osteochondral Defects

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

St. Jude Medical 8-Channel Adapter. Clinician's Manual

ExiPrep TM Viral DNA/ RNA Kit

ExiPrep Plus Viral DNA/RNA Kit User s Guide ExiPrep Plus Viral DNA/RNA Kit ExiPrep Plus Viral DNA Kit ExiPrep Plus Viral RNA Kit

SelectTech 4.1 Bench. Assembly Manual

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial


CDR Positioning System User Guide

NEPHROCHECK Calibration Verification Kit Package Insert

RealLine HIV quantitative Str-Format

SelectTech 3.1 Bench Assembly / Owner s Manual

C200 bands are available in a variety of colors. Visit us at LifeTrakUSA.com

III Instructions CPI - Condylar Position Indicator. These instructions apply to the following items: h2500 Includes: 9611 D 9615 D

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

USER S MANUAL QUESTIONS? CAUTION. Visit our website at. new products, prizes, fitness tips, and much more!

Dip Station G

limbsandthings.com Advanced Catheterisation Trainer User Guide For more skills training products visit Limbs & Things Ltd.

GLP-1 Platinum ELISA PRODUCT INFORMATION & MANUAL. Enzyme-linked Immunosorbent Assay for quantitative detection of GLP-1 BMS2194

CHAIR ASSEMBLY & CARE GUIDE

TABLE OF CONTENTS THANE DIRECT USA - 1 YEAR LIMITED WARRANTY

ezkine Th1/Th17 Whole Blood Intracellular Cytokine Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Product Information Packet Table of Contents. Introduction. Pit Shark Attachment. Attachment for Pendulum Rack. Introduction...

How to Use ENBREL : Vial Adapter Method

MULTI-FUNCTIONAL CAGE MWM Model MWM Retain This Manual for Reference OWNER'S MANUAL

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

RealLine HCV Qualitative Str-Format

MARCY DIAMOND ELITE UTILITY BENCH MD-440. Model MD-440. Retain This Manual for Reference OWNER'S MANUAL

SYNC SYNCOWNER S MANUAL. u u u. For maximum effectiveness and safety, please read this Owner s Manual and view the Video before using your SYNCFLEX

IGS-02 CALF RAISE BENCH. Model IGS-02. Retain This Manual for Reference OWNER'S MANUAL

Instructions for Use Enbrel (en-brel) (etanercept) injection, for subcutaneous use Single-dose Prefilled Syringe

Longevity Offset and Oblique Liners. Surgical Technique

RODENT Hepatocytes Care Manual

CultureWell Culture Systems and CultureWell Coverslips

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

COMPETITOR COMPETITOR WEIGHT BENCH. Model CB Retain This Manual for Reference OWNER'S MANUAL

RAPIDSORB RAPID ReSORBABLe CRANIAL CLAMP

Instructions for Use Reprocessed ENDOPATH XCEL Bladeless Endoscopic Trocars and Cannulas. Reprocessed Device for Single Use.

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

SAFETY LABELS CAUTION: PINCH POINT. Make sure locking pin is fully engaged before beginning forward and side lift exercises.

Owner s Manual For maximum effectiveness and safety, please read this owner s manual and view the video before using your Total Gym 1100.

POWER STATION With Fold up Bench

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

EXERTEC FLAT BENCH ETC-2.1. Model ETC-2.1. Retain This Manual for Reference OWNER'S MANUAL IMPEX INC.

CATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems

Patient Lifter (Hydraulic Lift) Information for the Patient A Guide for Patients in the Home

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

SP150 OWNER S MANUAL Product may vary slightly from the item pictured due to model upgrades

Thermo Scientific ART Pipette Tips. superior tips. for any application, any pipette

SIGNATURE SERIES OLYMPIC FLAT BENCH

The Bowflex Conquest Home Gym Assembly Instructions

Product handbook. Tel.:

FLAT BENCH SB Model SB Retain This Manual for Reference OWNER'S MANUAL

insafe System - Directions for Use

Stretch Beyond Your Expectations.

Product Information Packet

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

DELUXE HOME GYM HG Model HG Retain This Manual for Reference OWNER'S MANUAL

Tips for Training New Customers

Human total IgG Platinum ELISA

PROFESSIONAL GRADE CHEST EXPANDER INSTRUCTION MANUAL AND EXERCISE GUIDE. Engineered by

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Transcription:

USER GUIDE USER GUIDE PCR Starter Kit For 3 3-well blocks, 0. ml Part. No. 4485765 Revison B For Research Use Only. Not for use in diagnostic procedures.

Manufacturer's address: Life Technologies Holdings Pte Ltd Block 33 Marsiling Industrial Estate Road 3 #07-06, Singapore 73956 The information in this guide is subject to change without notice. DISCLAIMER: TO THE EXTENT ALLOWED BY LAW, LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S) WILL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE, OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT, INCLUDING YOUR USE OF IT. Important Licensing Information: This product may be covered by one or more Limited Use Label Licenses. By use of this product, you accept the terms and conditions of all applicable Limited Use Label Licenses. Trademarks: All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. 07 Thermo Fisher Scientific Inc. All rights reserved.

Contents Product description...4 Kit contents...4 How to use the MicroAmp Splash-free 96-well Base...6 How to use the MicroAmp 3 3-Well Retainer...7 Prepare samples using MicroAmp reaction tubes or tube strips...7 How to use the MicroAmp Adhesive Film Applicator...8 Seal a PCR plate with adhesive film...8 How to use the MicroAmp Cap Installing Tool...9 Seal a PCR plate with MicroAmp Optical (Flat) Cap Strips...9 Seal a PCR plate with MicroAmp Domed Cap Strips... 0 Remove cap strips from a PCR plate... 0 How to use the MicroAmp Multi Removal Tool... Open a tube with attached cap... Remove cap strips from a PCR plate... Remove a PCR plate from a sample block... Remove a PCR plate from a sample block with roboslots... 3 Limited product warranty... 3 MicroAmp plastic compatibility chart... 4 MicroAmp plastic consumables for Applied Biosystems PCR systems... 6-3-

Product description The PCR Starter Kit contains sample consumables necessary to start using your new Applied Biosystems Thermal Cycler. These consumables are designed to promote efficient heat transfer to obtain fast, high-performance polymerase chain reaction (PCR). The table below lists the samples included in the kit. It does not list the actual quantities of the starter kit components. To re-order any of these items refer to the catalog number. Note: For safety and biohazard guidelines, refer to the Safety appendix in the user guide for your thermal cycler. Read the Safety Data Sheets (SDSs) and follow the handling instructions. Wear appropriate protective eyewear, clothing, and gloves. Kit contents Component Cat. No. Quantity [] Image MicroAmp TriFlex 3 x 3-Well PCR Reaction Plate A380 3 ea MicroAmp 3-Well Clear Adhesive Film A38 0 pc MicroAmp 8-Cap Strip, clear N800535 pc MicroAmp 8-Tube Strip with attached domed caps, 0. ml A30589 pc MicroAmp Splash-Free 96-well Base 43063 ea [] This number refers to the quantity included in the starter kit, and may differ from the quantity received when re-ordering components using the catalog numbers provided in the table. -4-

Component Cat. No. Quantity Image MicroAmp 3 3-Well Retainer N/A 3 ea MicroAmp Cap Installing Tool 433005 ea MicroAmp Adhesive Film Applicator 433383 ea MicroAmp Multi Removal Tool 433950 ea -5-

How to use the MicroAmp Splash-free 96-well Base The MicroAmp Splash-free 96-well Base is compatible for use with MicroAmp reaction plates, tube strips, or reaction tubes, and provides a stable platform from which you can set up your experiment. Step Action a. Set up the 96-well base. If using reaction plates, place the PCR plate on the base. Set up base and add reaction mix 3 If using tubes, place the tray on the base and load the tray with tubes. b. Pipette the reaction mix into the tubes/wells. c. Seal the plate/tubes. MicroAmp 8-Cap Strip or adhesive film MicroAmp Optical 96-Well Reaction Plate 3 MicroAmp Splash Free 96-Well Base If using reaction plates, seal the PCR plate with adhesive film. If using tubes, cap the tubes with the Cap Installing Tool. 3 Place plate or tubes into instrument a. Remove the plate or tray with tubes from the 96-well base. b. Place the plate or tray with tubes into the sample block. -6- MicroAmp Reaction Tube MicroAmp 96-Well Tray for Veriflex Blocks 3 MicroAmp Splash Free 96-Well Base

How to use the MicroAmp 3 3-Well Retainer The MicroAmp 3-well Retainer is used to provide support and distribute pressure evenly across the sample block. The retainer is compatible for use with MicroAmp tubes and tube strips. IMPORTANT! The retainer is essential for optimal performance, and its usage is recommended at all times for the ProFlex 3 3-Well PCR System. The retainer allows pressure to be distributed evenly over the tubes to ensure a proper seal, and prevent tubes from being crushed or deformed. Prepare samples using MicroAmp reaction tubes or tube strips Step Fill and cap tubes Action a. Pipette the reaction mix into the tubes. b. Cap tubes or seal the tube strips with cap strips using the Cap Installing Tool. Load tray a. Ensure a retainer is on the sample block. b. Load the tubes or tube strips into the sample block. -7-

How to use the MicroAmp Adhesive Film Applicator The MicroAmp Adhesive Film Applicator enables you to ergonomically push an adhesive film down upon a PCR plate to form a tight seal and minimize air bubbles. This tight seal will prevent well-to-well contamination and sample loss. Seal a PCR plate with adhesive film Step Apply film to plate Action a. Place the PCR plate on a Splashfree 96-well base. b. Remove the backing from the adhesive film. c. Place the adhesive film on the PCR plate, making sure to cover all the wells. a. Rub the flat edge of the applicator back and forth along the long edge of the plate b. Rub the flat edge of the applicator back and forth along the short edge (width) of the plate. Seal plate c. Rub the end of the applicator horizontally and vertically between all wells. d. Rub the end of the applicator around all outside edges of the plate using small back and forth motions to form a complete seal around the outside wells. -8-

How to use the MicroAmp Cap Installing Tool The MicroAmp Cap Installing Tool enables you to ergonomically seal MicroAmp reaction tubes in a tray retainer set or 96-well reaction plate. This tight seal will prevent well-to-well contamination and sample loss. Seal a PCR plate with MicroAmp Optical (Flat) Cap Strips Step Apply cap strip to plate Action a. Place the PCR plate on a Splashfree 96-well base. b. Align the flat cap strip over the appropriate wells of the PCR plate. Align tool 3 Seal plate a. Slip your fingers through the handle of the Cap Installing Tool. b. Grasp the tool with the circular side facing up, and the grooved side facing down. a. Place the grooved rings over the first caps in a row. b. Push and seat each cap firmly in place. Use a rocking motion to properly seat each cap. 3 4 5 6 7 8 9 0 A B C D E F G H -9-

E F G H Seal a PCR plate with MicroAmp Domed Cap Strips Step Apply cap strip to plate Action a. Place the PCR plate on a Splashfree 96-well base. b. Align the domed cap strip over the appropriate wells of the PCR plate. Align tool 3 Seal plate a. Slip your fingers through the handle of the Cap Installing Tool. b. Grasp the tool with the grooved side facing up, and the grooved circular side facing down. a. Place the circular holes over the first caps in a row. b. Push and seat each cap firmly in place. Use a rocking motion to properly seat each cap. 3 4 5 6 7 8 9 0 A B C D E F G H Remove cap strips from a PCR plate Use the tool to remove MicroAmp Caps or MicroAmp Optical Caps from PCR plate and tray/retainer assemblies. Step Action Insert the small protrusions on the side of the Cap Installing Tool under the webbing between the caps on a cap strip. Slowly pry the strip from the plate or tray/retainer assembly. 3 4 5 6 7 8 9 0 A B C D -0-

A B How to use the MicroAmp Multi Removal Tool The MicroAmp Multi Removal Tool makes it easy to open caps, and remove PCR plates that get stuck on the sample block due to heat expansion after performing PCR. Use this multi-functional tool to open MicroAmp Tubes or GeneAmp Tubes with attached caps, remove PCR plates from a thermal cycler sample block, and remove cap strips from reaction tubes in a PCR plate and tray retainer assembly. Open a tube with attached cap Use the tool to open MicroAmp Tube with Cap, GeneAmp Tubes, or Fast Reaction Tube with Cap. Step Action Insert tube into U-shaped slot. Lift Multi Removal Tool to pry lid open. Remove cap strips from a PCR plate Use the tool to remove MicroAmp Caps 8 or Strip from a PCR plate or tubes in a tray/retainer assembly. Step Action Insert the small protrusions on the side Multi Removal Tool under the webbing between the caps of a cap strip. 3 4 5 6 7 8 9 0 Slowly pry the strip from the plate or tray/retainer assemblies. C D E F G H --

B C A D B E C F G D H E F G H Remove a PCR plate from a sample block Use the tool to remove MicroAmp Optical 96-Well Reaction Plate or 96-Well Fast Thermal Cycling Plate from the thermal cycler sample block. Step Action Insert prong of Multi Removal Tool beside or adjacent the side of the PCR plate. Use the single pronged side of the tool on the short side of the plate. Use the two-pronged side of the tool on the long side of the plate. A 3 4 5 6 7 8 9 0 Pry to remove the plate from the sample block. 3 4 5 6 7 8 9 0 --

Remove a PCR plate from a sample block with roboslots Use the tool to remove MicroAmp 384-Well Reaction Plate or 96-Well Fast Thermal Cycling Plate from a thermal cycler sample block. Step Action Insert the two hook protrusions into the short side of the PCR plate. Lift to remove the plate from the sample block. Limited product warranty Life Technologies Corporation and/or its affiliate(s) warrant their products as set forth in the Life Technologies' General Terms and Conditions of Sale found on Life Technologies' website at www. thermofisher.com/us/en/home/global/terms-and-conditions.html. If you have any questions, please contact Life Technologies at www.thermofisher.com/support. -3-

MicroAmp plastic compatibility chart 96-well 0. ml reaction plates Product Catalog No. Optical 96-Well Plate N800560, 43683 Optical 96-Well Plate with Barcode 4306737, 436659 96-Well Plate with Barcode & Optical Caps 4030 Optical 96-Well Plate with Barcode & Optical Adhesive Films 43430 EnduraPlate Optical 96-Well Clear Plate with Barcode [] 4483354, 448335 TriFlex 3 x 3-Well Reaction Plate [] A380, A38 96-well 0. ml reaction plates Fast Optical 96-Well Plate, 0. ml 4346907 Fast Optical 96-Well Plate with Barcode, 0. ml 4346906, 436693 EnduraPlate Optical 96-Well Fast Clear Plate with Barcode [] 4483485, 4483494 384-well reaction plates Optical 384-Well Plate 4343370 Optical 384-Well Plate with Barcode 4309849, 43670, 434384 EnduraPlate Optical 384-Well Clear Plate with Barcode [] 448385, 448373 Strip tubes and caps Fast 8-Tube Strip, 0. ml 435893 Optical 8-Tube Strip with Attached Optical Caps, 0. ml 8-Tube Strip with Attached Domed Caps, 0. ml 8-Tube Strip, 0. ml [] A30588 A30589 N800580 Optical 8-Tube Strip, 0. ml 436567 8-Cap Strip [] N800535, N80535 Optical 8-Cap Strip 43303 -Cap Strip [] N800534, N80534 Single tubes Fast Reaction Tube with Cap, 0. ml 435897, 435893 Reaction Tube with Cap, 0. ml [] Reaction Tube without Cap, 0. ml [] Optical Tube without Cap, 0. ml N800540, N8006, N80540 N800533, N80533 N800933 Seals and covers Clear Adhesive Film 43063 Optical Adhesive Film 4360954, 4397 3-Well Clear Adhesive Film [] Accessories A38 Splash-Free 96-Well Base 43063 96-Well Support Base 4379590 96-Well Base N80053 96-Well Reaction Tube/Tray/Retainer Set, 0. ml 403083, 403086 [] Multiple colors are available. [] Do not use MicroAmp 3 3-Well Retainer. -4-

3 x 3-well 96-well, 0. ml 96-well, 0. ml (Fast) 384-well ProFlex Veriti, ProFlex, SimpliAmp Veriti ProFlex, Veriti 96-well 0. ml reaction plates [] 96-well 0. ml reaction plates 384-well reaction plates Strip tubes and caps Single tubes Seals and covers [] Seals and covers -5-

MicroAmp plastic consumables for Applied Biosystems PCR systems These consumables are compatible with the ProFlex PCR system with 3 3-well 0. ml blocks. Go to thermofisher.com/plastics for additional details. 96-well 0. ml reaction plates Product TriFlex 3 x 3-Well Reaction Plate [] Strip tubes and caps Optical 8-Tube Strip with Attached Optical Caps, 0. ml 8-Tube Strip with Attached Domed Caps, 0. ml 8-Tube Strip, 0. ml [] A380, A38 A30588 A30589 N800580 Optical 8-Tube Strip, 0. ml 436567 8-Cap Strip [] Optical 8-Cap Strip 43303 Single tubes Reaction Tube with Cap, 0. ml [] Reaction Tube without Cap, 0. ml [] Optical Tube without Cap, 0. ml Seals and covers 3-Well Clear Adhesive Film [] [] Do not use MicroAmp 3 3-Well Retainer. [] Multiple colors are available. Catalog No. N800535, N80535 N800540, N8006, N80540 N800533, N80533 N800933 A38-6-

-7-

-8-

thermofisher.com/support thermofisher.com/askaquestion thermofisher.com 3 December 07