Application manual for the FOX laser 980 nm wavelength

Similar documents
Application manual for the Trabeculas-Laser 532 nm wavelength

An In-Depth Examination of Radiofrequency Assisted Liposuction (RFAL)

Diode Lasers Enable Diverse Therapeutic Applications

Offer a new service to Your customers!

Laser Effects on Skin Melanin

ALTERNATIVE TREATMENT

The Tumescent Technique TUMESCENT TECHNIQUE. by itself We strongly recommend that you consult with one of our nutrition and

The neov for Percutaneous Laser Disc Decompression (PLDD)

Arisa Ortiz, MD Director, Laser and Cosmetic Dermatology Assistant Clinical Professor Department of Dermatology UC San Diego

Golden standard for non-invasive body shaping Focused

SOLASE DENTAL DIODE LASER

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!

Low Level Laser treatment has revolutionized the Aesthetic Industry.

Innovative, integrated technologies for optimal clinical results. Reduced treatment time - with simultaneous lasing and suction

HTE introduces new product - 830nm-POINTER. Laser Medical Device

Mommy Makeover

PHOTOTHERAPY: WHAT DO WE KNOW AND HOW DOES IT WORK? Suite 3/36 O'Riordan Street Alexandria, Sydney NSW Australia

Surgical Pearls in the Management of Body Contouring by Liposculpture from Fournier s Syringe to Lipomatic

ProFractional. ProFractional Therapy. Tunable Fractional Solution. Advanced Fractional Aesthetic Laser Surgery

A Smarter Way To Sculpt. Frequently Asked Questions

SOLASE DENTAL DIODE LASER

Focused Ultrasound Body-shaping system Beijing Sanhe Beauty S & T Co.,Ltd

Cryolipolysis Slimming Machine With Cavitation, RF, Lipo Laser User Manual

SUNNY MAGNETIC EXERCISE BIKE

Mona SC-2 Ultra Pulse Co2 Fractional laser system. Beijing Sanhe Beauty S & T Co.,Ltd

Awide range of technologies are available to perform esthetic

Multi-spot laser coagulation with the VISULAS 532s VITE : A comparative study of 101 procedures

FEB-2015 ISSUE. Dr. David Pudukadan

Up to date literature at your disposal to discover the benefits of laser dentistry

7 Ways to Improve Your Liposuction Results. Karen Cronholm Product Manager April 21, 2011

Fat Transfer

Sunny Magnetic Exercise SF-B910

User Guide and Operating Manual

MICHAEL J. BROWN, M.D., P.L.L.C. Aesthetic Cosmetic Plastic Surgery

M & T srl. medical & technology

Stress Wave Focusing Transducers

Footprints for Human beings... REV-MED

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

CIRCUIT ZONE ELLIPTICAL

The cataract laser technology of tomorrow is here for you today.

CROSS TRAINING MAGNETIC TREADMILL

Facts About Diabetic Eye Disease

NONABLATIVE RESURFACING

Introduction to Physical Agents Part II: Principles of Heat for Thermotherapy

powered by technology easy laser guide

HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION. Main Application Fields UROLOGY GENERAL SURGERY ENT

Focused Ultrasound Body shaping system

A G E N D A. I. Non-Invasive Body Contouring II. Benefits III. Treatment Options IV. Treatment Zones V. Q&A VI. Media VII.Results

Non-Ablative Rejuvenation

LASERS: STEPPING INTO CONTEMPORARY PERIODONTICS

HOLMIUM:YAG LASER WHEN POWERFUL VERSATILITY INTEGRATES UNMATCHED PRECISION.

REVOLVE System Instructional Guide

Comparison of 635nm Red Light Transmission Through Skin and Subcutaneous Fat

Laser Applications in Dermatology & Orthopedics

Dr. Mohammed T Omar Associate professor CAMS Mobile: Office: 2074

plastic surgery reconstructive surgery aesthetic surgery

Cannulas, Applicators, Collectors, Accessories and Extras

INSTRUCTIONS FOR USE AND CARE

Dual wavelength (1540nm nm) mixed technology for fractional resurfacing in skin rejuvenation Background

CLINICAL STUDY REDUCTION OF LOCALIZED AND GENERALIZED ADIPOSE TISSUE BY CONTROLLED COOLING IN ABDOMEN AREA

Treatment Principle. A vacuum elevates the target tissue, bringing it closer to the energy. Infrared light(ir) directly he -ats the targeted area.

V2 June Pump Mishaps

SAFE EFFECTIVE EASY & VERSATILE PATIENT FRIENDLY. Laser wavelength highly absorbed by H 2

Technical support: +49 (0)7223 /

Pulsavac Plus Wound Debridement. Versatile from Grip to Tip

SP850 OWNER S MANUAL

In-vivo histopathological study of YouLaser MT interaction with the skin. A laser device emitting combined 1540 and nm wavelengths.

USER MANUAL CAUTION. MADE IN CHINA 2015 Body Action Enterprise Co., Ltd. All rights reserved.

User Manual.

HealthCare International, Inc. PO Box 1509, Langley, WA P: (360) or (800)

Motorised Treadmill Model No: JI1625

The ultimate Technology for Cellulites and Slimming.

CRYO T-SHOCK by PAGANI

WHY PLASMA TECHNOLOGY?

Dual modality body shaping study with RF and IR technologies utilizing SharpLight s FormaxPlus Platform.

A Never Obsolete Face and Body Platform

NURSING PRACTICE GUIDELINES

Laser LASER. Definition. History. Dr. Sabine Mai, MSc, MAS Physiotherapy & Rehab. Light Amplification by Stimulated Emission of Radiation

Safety Instructions. Training and Operating Instructions. Table of contents. Training 22

SYSTEM OVERVIEW MINIMALLY INVASIVE ROBOTIC LASER THERMOTHERAPY

MAGNETIC ELLIPTICAL TRAINER SF-E3608 USER MANUAL

world [2]. One product of such innovative engineering in is the ultrasound-assisted liposuction

MAGNETIC ELLIPTICAL TRAINER SF-E3608 USER MANUAL

Lag Screw Device Intended for symphyseal fracture fixation of the mandible

Use manual Model: WL-7202C. Cryolipolysis Cool-sculpturing Fat Freezing Machine

Cold Laser Therapy (Low Level Laser Therapy) -

Daryl Mossburg, BSN RN Clinical Specialist Sciton, Inc.

Cryolipolysis Cool-sculpturing Slimming Machine

Information about liposuction Part 1 of 3

B200A Infant Phototherapy Unit

Light EVO. Taking care of people, our masterpieces. Multiple Wavelengths for the Highest Challenges in Laser Applications.

Why choose In Light Wellness Systems?

WHERE HEAT MEETS COLD

LASERS: CAN THEY TREAT SPIDER VEINS? Steven E. Zimmet, MD

A Patient s Guide to Arthroscopy of the Hip

WHITE PAPER. Thermo-Optically Powered (TOP ) Surgery. Advances in Surgical Techniques. By Felix Feldchtein, Ph.D. Gregory B. Altshuler, Ph.D., D.Sc.

Chapter 23 Devices for Weight Loss and Fatty Tissue

XF Microlens Optic and XD Microlens Compression Optic for Non-Ablative Fractional Skin Treatment with the Palomar Icon System

PARABOLA SLENDERIZING METHOD

USER MANUAL EN. IN 5559 Elliptical Trainer insportline Cruzz

Transcription:

Lipolysis Application manual for the FOX laser 980 nm wavelength

Bessemerstr. 14 90411 Nürnberg phone: +49.911.21779-0 fax: +49.911.21779-99 info@arclaser.de www.arclaser.de WARNING For your own safety follow all guidelines for handling the equipment and follow the safety instructions in this manual. 2 0 1 1 A.R.C. Las er GmbH all rights res erved. N ames other here named c arrier c ompanies or produc ts are trademarks theirs res pec tive holder of rights. E very endeavour has been made at guarantee, that all performed informations are ac c urate in this manual. A.R.C. Las er as s ume yet no warranty for the truenes s of the c ontent in this handbook. June 2 0 1 1

Content 1) Laser safety...4 Safety instructions...5 2) Basics of laser application...6 3) Application...8 Pre-treatment tests...8 What is laser assisted lipolysis?...8 What can laser assisted lipolysis do?...8 Indications...8 Treatment areas...9 Laser assisted lipolysis in addition to liposuction...9 Advantages in general...9 4) Technique...10 Single use hand piece...10 Multi use hand piece...11 5) Pre-surgical preparations...12 6) Treatment procedure...13 7) Remarks...16 8) Behavior in case of a system error...16 Page 3 of 16

1) Laser safety Laser radiation emitted by the FOX laser can cause severe damage to the patient as well as to the user and third persons accompanying the laser use. The FOX laser is classified in the laser class IV. This means that the radiation can cause damage when it is directly applied to any tissue and also if the radiation is scattered or reflected. The FOX laser radiation is intense and efficient to coagulate and evaporate tissue. The most serious injuries occur, when laser radiation is exposed to the eye. Even low laser power is able to damage the retina of the eye, which is not reversible. This may cause permanent blindness. The danger depends on the wavelength of the radiation and on the dose (energy density per time). Water absorption Laser radiation in the wavelength range between 400 and 1400 nm is most dangerous for the eye. The cornea as well as the anterior chamber, the lens and the vitreous body of the eye contain mainly water. The other tissue components (mainly collagen) play a minor role for the laser tissue interaction. Between 400 and 1400 nm wavelength water has very low absorption. Therefore the laser radiation is transmitted very well and nearly the full power reaches the retina, where it is absorbed by the blood and the retinal pigment ephithelium. The FOX laser emits infrared laser radiation, therefore it is absolutely necessary to wear eye safety goggles when using the FOX laser system. With its intensity (e. g. focused beam), the Fox laser radiation can also do harm to skin or other tissue. The radiation can light up inflammable material. Page 4 of 16

Safety instructions To avoid any injuries it is important to follow the laser safety instructions: 1. Any user of the Fox laser system has to be trained by A.R.C. Laser authorized personal or by someone trained by A.R.C. Laser authorized personal. 2. The room / the area, where the laser system is used has to be signed with the laser warning symbols in a way that everyone can easily see that there is a laser area, which should not be entered without the adequate protection while the laser is in use. 3. Do not use the system whenever you are not sure that every component works in the dedicated way. Keep an eye on the fiber delivery: The spot shown by the aiming beam should always be round and defined, no scattering should occur. You may test this by using a light paper and holding the bare fiber end of LL1303x-s in a distance of about 5 cm (you have to put the laser on Ready mode / laser safety goggle!). 4. Whenever the laser is on Ready mode (2 yellow Ready-LEDs on) every person within the area where radiation from the laser can occur (laser treatment area / laser room) has to wear laser safety goggles which is suitable to protect the eyes from FOX laser radiation. Ready-LEDs 5. The laser has to be used only for the defined application; never irradiate any other material / tissue beside the intended use. 6. Special care should be taken to avoid irradiating reflecting materials. Reflected laser radiation can cause the same harm as direct application. 7. Switch off the Ready mode of the laser when the laser is not in use; e. g. during operation breaks or at the end of the surgery. Page 5 of 16

2) Basics of laser application The intended effect of the laser application is based on the interaction of the radiation with the tissue components. The laser radiation is absorbed, scattered or reflected by the tissue. Air has only little influence on the FOX radiation and therefore the interaction between air and the FOX radiation can be neglected. Reflection plays a major role with metal, glass and other reflecting surfaces. When we apply the FOX radiation to tissue the reflection is not dominant. Nevertheless it is not zero! When the radiation is scattered in the tissue, it does not influence the absorption. Absorption is mainly responsible for the efficiency of the laser radiation. Absorption means that the FOX laser radiation is converted mainly into heat, which causes the desired effects (coagulation / vaporisation). With low energy density (big laser spot or low power) the heat which is achieved in the tissue can cause heating of the tissue. The smaller the spot size is, or the higher the power is set, the warmer it gets. There is a limit, when the tissue does no longer tolerate the heating, tissue proteins denaturate, coagulation occurs. The next limit is achieved when tissue water (intraand extracellular water) suddenly evaporates (> 300 C). Tissue is fragmented and destroyed. Cutting / evaporation is achieved. Temperature effect Temperature > 40 C 45 65 C Effect enzyme induction, membrane disaggregation, edema tissue damage, reversible or irreversible, dependent on the irradiation time > 65 C coagulation > 100 C dehydration > 150 C carbonisation > 300 C vaporisation, ablation (removal of tissue) some 1000 C ionisation, immediate burn (shock wave formation) Page 6 of 16

Tissue cutting always needs high energy densities (high power or small spot size). At the cutting edges, respectively beside the evaporation zones the tissue is always affected by the heat (coagulation). The positive effect and advantage of the laser use is that this can stop bleeding from cut vessels (hae mostasis). The negative effect is caused directly at the cutting edge where more than 150 C occur. There is a development of carbonization, created by burned carbon, which is toxic and prolongs the healing of the wound. To avoid extended collateral damage (carbonisation and coagulation) at the cutting edges the application mode of the laser can be modified to a pulsed mode, which causes less damage. In continuous mode the laser permanently emits radiation. In pulse mode the tissue can cool down between each laser pulse and therefore the side effects of the heating can be reduced. Page 7 of 16

3) Application Pre-treatment tests The FOX laser does an automatic internal testing on the power output before the device can be used. Keep an eye on the system components. Especially take a look on the fiber delivery: The spot shown by the aiming beam should always be round and defined, no scattering should occur. You may test this by using a light paper and holding the single use hand piece (LL13030-s / LL13031-s / LL13032-s / LL13033-s) or a bare fiber end (LL13034-s / LL13035-s) in a distance of about 5 cm (you have to put the laser on Ready mode). When doing this, be aware to wear safety goggles. What is laser assisted lipolysis? Destruction of the adipose deposits by a controlled thermal effect caused by interaction of laser irradiation on the adipose tissue: A subcutaneous laser treatment in fat. What can laser assisted lipolysis do? Destruction of the fat cells without damaging the surrounding tissue, second tightening of the tissue: Smoothing the skin Skin tightening Reduction of fat deposits Contouring of the treatment area Indications Treatment of small areas In addition to liposuction Areas of laxity Lipoma Page 8 of 16

Treatment areas Abdomen Knee Hips Waist Arms Trochanter Cerival Laser assisted lipolysis in addition to liposuction Laser assisted lipolysis in addition to liposuction is beneficial because the thermal rising in the dermis leads to: Stimulation of fibroblasts Production of collagen Tightening of the tissue General advantages The method is beneficial for patient and surgeon because: Only one treatment session Ambulant procedure Local anesthesia No cuttings or scars Low risk of haematoma Page 9 of 16

4) Technique For the application the fiber end of the single use hand piece or bare fiber has to be inserted into the fiber coupler of the FOX laser 980 nm, 12 Watt output power, 400 µm or 300 µm version. Single use hand piece: The single use hand piece (LL1303x-s) is already preassembled and is delivered sterile. There is 600 µm or 400 µm Fiber uses for both Fox II version (400 µm und 300 µm) for this application. For the devices with 400 µm coupling (yellow), the single use hand pieces (LL13030-s and LL13032-s) have yellow plug. 400 µm coupling LL13030-s LL13032-s For the devices with 300 µm coupling (white), the single use hand pieces (LL13031-s and LL13033-s) have white plug. 300 µm Kupplung LL13031-s LL13033-s The single use hand piece should be cleaned during surgery to avoid overheating of the tip is strongly advised. Any carbonisation/ burned fat / coagulation at the end of the hand piece may block or absorb the radiation. This leads to a decrease of the efficiency, overheating and destruction of the fiber tip. Page 10 of 16

Multi use hand piece: How to prepare the bare fiber (LL13034-s oder LL13035-s) and surgery hand piece (HS11019) and cannula (ZU01044) for surgery and how to use it: The end of the bare fiber should be at least 2 3 mm longer than the end of the lipolysis cannula. For the devices 400 µm coupling (yellow), the fiber (LL13034-s) has TWO shrink tubes on the fiber plug. LL13034-s For the devices 300 µm coupling (white), the fiber (LL13035-s) has ONE shrink tube on the fiber plug. LL13035-s The surgery hand piece (HS 11019) consists of 4 parts: the long part which has a connector for the hand piece tips (luer connector). The short part, which is screwed in the long part and two plastic cones ( ME 03104) which trap the fiber when the two metal parts are screwed tightly together. During usage of the surgery hand piece the hand piece parts do not have to be disassembled; there is always the risk of loosing the small plastic cones (ME01304). For removing and entering the fiber in the surgery hand piece, the tight fixation only has to be opened by 2 to 3 turns. Before the treatment,should sterilize the hand piece ( HS11019), the cannula (ZU01044) and the fiber (LL13034-s oder LL13035-s). If the fiber end gets in contact to the cannula end during surgery, the cannula end warms up and after some time the tip may melt! Be cautious, a hot cannula end can cause thermal damage to any tissue!!! To avoid extended heating of the fiber tip, or even more dangerous, heating of the cannula end, the fiber end has to be cleaned during surgery if it gets covered by burned blood or coagulated tissue or any carbonisation. Page 11 of 16

5) Pre-surgical preparations Application Before using the laser system on the patient, all the pre-surgical preparations (anesthesia, etc.) should be completed. To avoid damage and overheating of the fiber tip, it is advised to mobilize the application area before using the laser hand piece the first time by a standard small liposuction cannula. Kleinsche infusion solution (anesthesia) Sterile table Important steps Selection of patients Clinical history Patient letter of agreement Picture (preoperative) Pre-treatment Marking the area Preparing the sterile table Preparing the sterile area Moderate tumescent: Kleinsche infusion solution: 150 cc. to 250 cc. for a size of 10 x 10 cm Several access points Page 12 of 16

6) Treatment procedure The hand piece with cannula has to be moved continuously parallel to the skin surface in the fat layer underneath the dermis, in a range of about 0.8 to 2.5 cm depth. Laser settings area Power [W] abdomen up to 12 arms, knee 8 10 chin 6 8 other areas around 8 Speed of treatment treatment pulse on M pulse off slow 10 ms 10 ms fast 1.5-2.0 s 300 ms fastest cw (max. 9 Watt) - U The faster the treatment the more risk of possible burns in case the user stops moving the hand piece. Page 13 of 16

Make a continuous movement until the total input energy reaches minimum 2500 to 3500 J (minimal total energy for an area of 10 x 10 cm). The total energy varies from 2200 J (hips) up to 51000 J (abdomen). (1) To control the surface temperature, the second hand can be used as a tem- perature sensor. The surface temperature rises slightly from about 32 to 35-36 (1) J. P. Reynaud et. al., Lipolysis using a 980 nm diode laser: a retrospective analysis of 534 procedures, Aesth Plast Surg (2009) 33: 28 36 Laser times (10 x 10 cm area, pulse mode 10 ms/10 ms) Power 2500 J 3000 J 3500 J 6W 14 min 16 min 20 min 7W 12 min 14 min 16 min 8W 10 min 12 min 14 min 9W 9 min 11 min 12 min 10 W 8 min 10 min 11 min 11 W 7.5 min 9 min 10.5 min 12 W 7 min 8 min 10 min Post-operative# Adequate anesthesia (if necessary) Compression Medication: antibiotic (Gemfibrozil) Protein diet for 3 days 1.5 2 liter fluid increase Page 14 of 16

7) Remarks Advice / Remarks Additional liposuction can improve the aesthetic result. It offers immediate volume removal which is not possible with laser assisted lipolysis without suction. The final aesthetic result will be reached after a minimum of 3 months. 8) Behavior in case of a system error In case of any failure in the power generation of the laser, the power which is delivered to the patient decreases. Overpower cannot occur as the current for the laser diode is limited by a fuse. Less power than expected results in less effect. When this occurs, the user can check for the fiber delivery first and then for the laser. Any damage to the fiber results in a decrease of the power. A broken fiber shows reflections of the aiming beam at the breakage. The user should not continue the use of the laser and change the fiber. When he checks the laser a restart results in a new check of the system at the beginning. When the laser measures too low or too high power, the system does not start. Any error message displayed by the system can be checked in the operation manual. In case of any insecurity or questions please contact your local A.R.C. Laser representative. Page 15 of 16