PERFORATED CLICK X Augmentable pedicle screws for osteoporotic bone

Similar documents
Augmentable Pedicle Screws for Osteoporotic Bone. Perforated Click X. Surgical Technique

USS II Poly Perforated

TSLP Thoracolumbar Spine Locking Plate

MATRIX Spine System Perforated

VECTRA-T SURGICAL TECHNIQUE. The Translational Anterior Cervical Palate System. This publication is not intended for distribution in the USA.

The Versatile Polyaxial Solution for the Universal Spine Systems. USS II Polyaxial. Surgical Technique

TELEFIX SURGICAL TECHNIQUE. Implant system for the anterior stabilization of the thoracolumbar spine

SYNEX The vertebral body replacement with ratchet mechanism

USS II ILIO-SACRAL Modular System for Stable Fixation in the Sacrum and Illium

CSLP-Cervical Spine Locking Plate

PROXIMAL FEMORAL NAIL REMOVAL SET

LCP Metaphyseal Plates. For extra-articular fractures.

ARCH Laminoplasty System

Collinear Reduction Clamp

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

Interbody fusion cage for the transforaminal approach. Travios. Surgical Technique

Mini External Fixator.

3.0/3.5/4.0/4.5/6.5/7.0/7.3. Cannulated Screws. Surgical Technique

ECD EXPANDABLE CORPECTOMY DEVICE Continuously Expandable Vertebral Body Replacement for Tumour Cases

ARCH Laminoplasty System. Dedicated System for Open-door Laminoplasty.

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

OBSOLETED. LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Minimally Invasive Posterior Instruments

VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

The vertebral body replacement with ratchet mechanism. Synex. Surgical Technique

Surgical Technique & Product Catalogue. Guide for Open & MIS Procedures

3.5 mm Locking Attachment Plate

Cannulated Angled Blade Plate 3.5 and 4.5, 90.

SynCage-C short. Surgical Technique. This publication is not intended for distribution in the USA.

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

Technique Guide. Locking Attachment Plate. For treatment of periprosthetic fractures.

XRL A modular expandable radiolucent vertebral body replacement system

PFNA. With Augmentation Option.

The minimally invasive Schanz Screw system for complete spinal fracture reduction. USS Fracture MIS. Surgical Technique

VIPER Cortical Fix Fenestrated Screw System. Surgical Technique for OPEN & MIS Procedures

LCP DISTAL TIBIA PLATE

CERVIFIX Modular tension band system for posterior fixation of the occipito cervical spine, upper and lower cervical spine, and upper thoracic spine

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

LCP Medial Proximal Tibial Plate 4.5/5.0. Part of the Synthes LCP periarticular plating system.

USS Variable Axis Screw

Technique Guide. USS Fracture MIS. The minimally invasive Schanz Screw system for complete spinal fracture reduction.

Button Plate. Reinforcement for transosseous fixations.

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

MatrixNEURO. The next generation cranial plating system.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

In-Space. Interspinous distraction through a mini-open, posterior, unilateral approach.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

VA LOCKING CALCANEAL PLATES 2.7

Wrist Fusion Instrument and Implant Set.

SynCage. Surgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

Alignment Rod. For intraoperatively confirming correction of the mechanical leg axis.

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

CSLP-CERVICAL SPINE LOCKING PLATE For anterior, cervical fixation

SYNFLATE SYSTEM SURGICAL TECHNIQUE

Technique Guide. NFlex. Semi-rigid rods for posterior lumbar stabilization.

Technique Guide. ArcoFix. Anterior-only reduction plate.

3.5 mm LCP Extra-articular Distal Humerus Plate

LOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Humerus Block. Discontinued December 2016 DSEM/TRM/0115/0296(1) Surgical Technique. This publication is not intended for distribution in the USA.

The Top-loading Pedicle Screw and Rod System Designed for the Posterior Stabilization of the Lower Back. Click X System. Surgical Technique

Distal Radius Plate 2.4/2.7 dorsal and volar

Technique Guide. Orthodontic Bone Anchor (OBA) System. Skeletal implants for the orthodontic movement of the teeth.

In-Space. Percutaneous interspinous distraction.

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

Ref: Q400-09T1 EBI Spine. September 05/VS02. c/o BIOMET Spain Orthopaedics, S.L.

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

3.5 mm LCP Olecranon Plates

LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

LCP Percutaneous Aiming System 3.5 for PHILOS. For less invasive surgery at the proximal humerus.

The Titanium Tibial Nail System

Technique Guide. 3.5 mm LCP Olecranon Plates. Part of the Synthes locking compression plate (LCP) system.

LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Contact Fusion Cage. Surgical Technique

LCP Condylar Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

Technique Guide. LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

Femoral Neck System. Surgical Technique

LCP Periarticular Proximal Humerus Plate 3.5. The anatomic fixation system with anterolateral shaft placement.

PHILOS and PHILOS Long. The anatomic fixation system for the proximal humerus.

LCP Distal Fibula Plates. Part of the Synthes locking compression plate (LCP) system.

LCP Proximal Tibial Plate 4.5/5.0 with Periarticular Aiming Arm Instruments

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Surgical Technique. This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.

Surgical technique. synex. The vertebral body replacement with ratchet mechanism.

SYNCAGE EVOLUTION. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

VA-LCP Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

ACIS Anterior Cervical Interbody Spacer

LCP Superior Anterior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

LCP Distal Humerus Plates

USS Variable Axis Screw (VAS) System. For posterior fixation of the lumbar spine.

MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.

PFNA-II. Proximal Femoral Nail Antirotation.

Variable Angle LCP Forefoot/Midfoot System 2.4/2.7. Procedure specific plates for osteotomies, arthrodeses and fractures of the foot.

Transcription:

PERFORATED CLICK X Augmentable pedicle screws for osteoporotic bone Instruments and implants approved by the AO Foundation. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Image intensifier control Warning This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended. In addition, dedicated education on the bone cement instrumentation, associated risks and technique is mandatory. Processing, Reprocessing, Care and Maintenance For general guidelines, function control and dismantling of multi-part instruments, please contact your local sales representative or refer to: http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance For general information about reprocessing, care and maintenance of Synthes reusable devices, instrument trays and cases, as well as processing of Synthes non-sterile implants, please consult the Important Information leaflet (SE_023827) or refer to: http://emea.depuysynthes.com/hcp/reprocessing-care-maintenance

Table of Contents Introduction Perforated Click X 2 Indications and Contraindications 4 Surgical Technique Preoperative Planning 5 Surgical Technique 6 Notes and Warnings 12 Product Information Implants and Instruments 14 Perforated Click X Surgical Technique DePuy Synthes 1

Perforated Click X. Augmentable pedicle screws for osteoporotic bone. Improved anchoring and shear stability in osteoporotic bone Screw anchoring and vertebral body support thanks to cement cloud Six radial screw openings for 360 cement distribution Controlled cement injection, performed simultaneously or alternated at different levels Augmentation after final screw positioning 2 DePuy Synthes Perforated Click X Surgical Technique

Syringe Syringe provides tactile feedback during injection Adapter Adapter with Luer lock fits any commercial syringe Press-fit connection for leak-proof cement injection Perforated dual-core pedicle screw Cylindrical large core with low and broad thread flanks for higher strength in dense cortical bone shell of pedicle Cylindrical small core with high and thin thread flanks for cancellous bone in vertebral body Six radial openings for 360 cement distribution and optimal screw anchoring Large cannulation diameter for low cement injection resistance Kirschner wire cannulation for guided screw insertion over 1.6 mm Kirschner wire Minimal cement outflow from screw tip Perforated Click X Surgical Technique DePuy Synthes 3

Indications and Contraindications The Perforated Click X system is a transpedicular screw/rod system intended for the posterior stabilization of the thoracolumbar and lumbar spine. The Perforated Click X screws are cannulated. However, they may be inserted like standard solid Click X screws (see Click X System surgical technique) or like Cannulated Click X screws by means of Kirschner wire guidance (see Cannulated Click X surgical technique). The lateral perforations allow direct cement augmentation of the screw in the osteoporotic bone. General indications The implants can be used for the following indications in the area of the lower thoracic and lumbar spine Degenerative instabilities Instabilities following decompression Type A1 fractures and related types of the B and C group Type A2 and A3 fractures as well as similar fractures of the C group, if combined with an anterior intervention Tumors without anterior defect Osteoporosis when used concurrently with bone cement indicated for internal spinal fixation supplementation Contraindications Deformities In fractures and tumors with severe anterior vertebral body disruption, an additional anterior support is required Osteoporosis when used without cement augmentation Severe osteoporosis Note: Refer to the manufacturer's directions accompanying the bone cement for specific information on its use, indications, contraindications, precautions, warnings and side effects. 4 DePuy Synthes Perforated Click X Surgical Technique

Preoperative Planning Preoperative planning includes evaluation and assessment of the patient with regard to the specifications of the bone cement used for augmenting perforated Click X screws. Proper imaging equipment must be used to determine correct implant dimensions in relation to the anatomy. The decision whether or not to augment Perforated Click X screws can be taken intraoperatively, based on tactile feedback upon pedicle preparation and screw insertion. If screws are augmented, bilateral screw augmentation is recommended. Note: Do not reinforce more than six vertebrae with bone cement in one session. The injected cement pushes bone marrow into the blood circulation and can cause fat embolization. The amount of cement that is injected in one session should therefore be limited to about 25 ml or even less if a patient shows severely compromised cardiopulmonary function. Note: Handling knowledge of bone cement is required. Image intensifier control is highly recommended while injecting bone cement. Perforated Click X Surgical Technique DePuy Synthes 5

Surgical Technique This surgical technique contains complementary instructions on handling Perforated Click X screws. For the standard surgical Click X procedure consult the Click X System surgical technique. Notes on working with Kirschner wires If Perforated Click X screws are inserted over Kirschner wires also consult the technique guide on handling Cannulated Click X screws. Under image intensifier control ensure that each Kirschner wire is in the appropriate position for screw insertion. Especially the tip of the Kirschner wire should be radiologically monitored to confirm that it does not penetrate the anterior wall of the vertebral body and thus risking damage of the vessels in front of it. Kirschner wires are for single use. 1 Prepare pedicles and insert screws Instruments 01.606.203 Click X Basic Instrument Set in Vario Case 03.620.220 Screwdriver Shaft Stardrive, T25, cannulated, with Hexagonal Coupling, B 6.0 mm Optional instrument 01.624.103 Cannulated Instruments for Pedicle Preparation, in Vario Case Open and prepare the pedicles and insert the screws as defined in the Click X System surgical technique. Use the cannulated screwdriver shaft. Do not attach the 3-D heads yet. 6 DePuy Synthes Perforated Click X Surgical Technique

Assess the cortical shell for perforations. Note: In case of any perforation, special caution is required when bone cement is applied. Cement leakage and its related risks may compromise the physical condition of the patient. Select appropriate screw lengths. Choose screws with the maximum possible diameter and length to achieve maximum stability. 80% Adequate length. Radial openings well located in vertebral body. The Perforated Click X screw must enter in approximately 80% of the vertebral body. Notes on screw length If screws are too short, the bone cement risks being injected too close to the pedicle. If screws are too long, or placed bicortically, the anterior cortical wall may be penetrated and cement leakage may occur. Screw too short. Radial openings too close to pedicle. Precaution: It is imperative that the screw perforations are located in the vertebral body, close to the anterior cortical wall. For this reason 35 mm screws should only be placed in the sacrum. Perforated Click X Surgical Technique DePuy Synthes 7

Surgical Technique 2 Assess proper screw placement Use a B 2.0 mm Kirschner wire to clean the cannula for proper cement injection. 3 Prepare bone cement Prepare the bone cement according to the manufacturer s direction. Use syringes with Luer-Lock for injecting the bone cement. 8 DePuy Synthes Perforated Click X Surgical Technique

4 Inject bone cement Place the C-Arm in a lateral position to monitor the extrusion of the cement into the vertebral body. Additional image intensifier control in the AP projection is recommended. Note: Do not augment more than four screws at once. Note: Ensure that there is a firm connection between the adapter and the screw recess. Perforated Click X Surgical Technique DePuy Synthes 9

Surgical Technique 1. Inject approximately 0.5 ml cement per screw until cement extrudes from the perforations. Note: Ensure that no cement leakage occurs outside the intended area. Immediately stop the injection in the event of leakage. 2. Following the same order of screws, add another 0.5 1 ml of cement to each screw. The cement extrusion needs to be monitored under continuous image intensifier control. A growing cloud pattern should form. If a spider web-like pattern forms, wait approx. 30 to 45 seconds or proceed with another screw and return to the present screw later. 3. If more cement is needed or the injection pressure is too high, switch to the 1 ml syringes and inject more cement. Start again with the first screw. Augmentation is complete when each screw has been augmented with a total volume of approximately 2 to 3 ml. Note: Do not remove or replace syringes immediately after injection. This avoids contaminating the screw drive and the patient s soft tissues with cement drips. The longer the syringe remains connected to the screw, the lower the risk of contamination. Warning: Any cement remaining in the screw drive must be removed while it is still soft (or has not hardened) e.g. with the screwdriver shaft. This will ensure that future revision surgeries remain possible. Warning: The cement flow follows the path of least resistance. Therefore it is mandatory, during the whole injection procedure, to maintain real-time image intensifier control in the lateral projection. If the filling pattern does not behave as expected or if the cement is not clearly visible, the injection must be stopped. Wait until the cement has cured before removing adapters and continuing with the instrumentation. 11 DePuy Synthes Perforated Click X Surgical Technique

5 Attach Click X 3-D heads and assemble construct Prior to attaching the 3-D heads ensure that the pedicle screw heads are clean and not contaminated with any bone cement. Remove any cement from the soft tissues. Attach the 3-D heads and continue with the following steps according to the Click X System surgical technique. Perforated Click X Surgical Technique DePuy Synthes 11

Notes and Warnings Cement leakage The inherent risk of this technique is cement leakage. Risks can be minimized and complications rate reduced by observing the above mentioned technique. The second challenge that needs to be emphasized is fat embolism since the injected cement will push bone marrow into the blood circulation the amount of cement that is injected in one session should be limited to about 25 ml and less if a patient shows severely compromised cardiovascular function. Furthermore, systemic reactions during cement injection can occur as a consequence of cement monomer release. If significant leakage occurs, stop the procedure. Return your patient to the ward and perform a clinical assessment in order to clarify the neurological situation. If the neurological state is not compromised, there is no need for further surgical measures. If neurological function is severely compromised, an emergency CT scan should be performed in order to assess the amount and location of the extravasation. If applicable, open surgical decompression and cement removal may be performed as an emergency procedure. Extravasation In order to minimize the risk of extravasation, it is strongly recommended to follow the described surgical technique, i.e.: Use a Kirschner wire for pedicle screw placement Use a high-quality C-arm in lateral position Use highly viscous and highly radiopaque bone cement Additional image intensifier control in the AP projection is recommended. Leakage outside the vertebra What action is required if leakage occurs? If you recognize leaking outside the vertebra, stop the injection immediately. Wait for 45 seconds. Then slowly continue with the injection. Due to the faster curing in the vertebral body, the cement occludes the small vessels and the filling can be accomplished. It is possible to recognize amounts of cement as small as 0.2 ml. If filling cannot be performed as described, stop the procedure. 11 DePuy Synthes Perforated Click X Surgical Technique

Leakage into the spinal canal What action is required if leakage into the spinal canal occurs? Stop the injection. If the leak is very small, you may proceed as described in step 6. Fracture The risk of a fracture at adjacent levels appears to be increased after cement reinforcement. Patients and their doctors should therefore be made aware that if new pain occurs, a new fracture may have occurred. Radiological control should be performed and, if necessary, further reinforcement should be considered in such cases also including the adjacent vertebrae. All patients with osteoporotic fractures should be evaluated and treated by an osteologist or their family doctor and, if applicable, receive systemic treatment with vitamin D and bisphosphonates. Pregnancy Refer to the manufacturer s directions accompanying the bone cement indicated for internal spinal fixation supplementation for indications, contraindications, precautions, warnings and side effects (e.g. infertility, teratogenic effects). What screw size is recommended? Preoperative planning and selection of the appropriate screw length and diameter is important. In the average lumbar spine B 6.2 mm screws are recommended, as scientific papers report a higher rate of pedicle perforation with B 7.0 mm screws. Placement of pedicle screw What is the optimal position of the pedicle screw in the vertebral body? A pedicle screw must enter in approximately 80% of the vertebral body (see step 1). Perforated Click X Surgical Technique DePuy Synthes 11

Implants and Instruments Perforated Click X pedicle screws 04.606.223S 227S Click X pedicle screw B 5.2 mm, perforated, with Dual Core, TAN, length 35 55 mm, sterile 04.606.233S 237S Click X pedicle screw B 6.2 mm, perforated, with Dual Core, TAN, length 35 55 mm, sterile 04.606.243S 247S Click X pedicle screw B 7.0 mm, perforated, with Dual Core, TAN, length 35 55 mm, sterile All screw lengths available in 5 mm increments. Precaution: It is imperative that the screw perforations are located in the vertebral body, close to the anterior cortical wall. For this reason 35 mm screws should only be placed in the sacrum. 03.620.220 Screwdriver Shaft Stardrive, T25, cannulated, with Hexagonal Coupling, B 6.0 mm 492.200 Kirschner Wire B 2.0 mm with trocar tip, length 150 mm, Titanium Alloy (TAV) 14 DePuy Synthes Perforated Click X Surgical Technique

Augmentation material 07.702.211.02S Adapter for Stardrive T25, with Luer-Lock, 2 pieces, sterile 07.702.212.02S Screw Cementation Kit, sterile 07.702.016S Vertecem V+ Cement Kit, sterile 1 Vertecem V+ Mixer prefilled with cement powder 1 Monomer glass ampoule 03.702.215S Vertecem V+ Syringe Kit Content: 8 blue 1 cc syringes 5 white 2 cc syringes 1 one-way stop-cock Perforated Click X Surgical Technique DePuy Synthes 11

Implants and Instruments Click X Vario Cases 01.606.203 Click X Basic Instrument Set in Vario Case (make sure ratchet 388.652 or 388.654 is included) 01.606.404 Click X Implants in Vario Case Cannulated Pedicle Preparation Set 01.624.103 Cannulated Instruments for Pedicle Preparation in Vario Case 11 DePuy Synthes Perforated Click X Surgical Technique

Click X implants* 04.606.000* Click X Locking Cap Stardrive, T25, Titanium Alloy (TAN) 498.571* Click X 3D-Head for Pedicle Screw, posterior open, Titanium Alloy (TAN) 04.620.135* Rod B 6.0 mm, soft, curved, 180* lengths 35 85 mm, Pure Titanium 498.139* 143* 498.150* 154* Rod B 6.0 mm, straight, soft, TiCP, lengths 50 150 mm * Available non-sterile and sterile packed. Add suffix S to article number to order sterile product. Perforated Click X Surgical Technique DePuy Synthes 11

DSEM/SPN/1215/0402 01/16 Synthes GmbH Eimattstrasse 3 This publication is not intended for distribution in the USA. 4436 Oberdorf Switzerland Not all products are currently available in all markets. Tel: +41 61 965 61 11 Fax: +41 61 965 66 00 All surgical techniques are available as PDF files at www.depuysynthes.com www.depuysynthes.com/ifu 0123 DePuy Synthes Spine, a division of Synthes GmbH. 2016. All rights reserved. 036.000.572