Electrolyte Analyzer with Ion-Selective Electrode and Blood Gas analyzer

Similar documents
(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

Reference Material Institute for Clinical Chemistry Standards (ReCCS)

Reference Material Institute for Clinical Chemistry Standards (ReCCS)

Review. Standardization of Measurements for Cholesterol, Triglycerides, and Major Lipoproteins

Laboratory Medicine Standardization Activity in Japan

Depleting Lipoproteins from Serum

Technical Bulletin. Cholesterol Reference Method Laboratory Network (CRMLN) Overview. TB Rev. 0

assay Introduction Conclusions: The D-100 TM system proved to be a robust and reliable method for HbA 1c

Suppl. Table 1: CV of pooled lipoprotein fractions analysed by ESI-MS/MS

Commutability studies undertaken by the LNE : the case of lipid and lipoprotein testing. Vincent Delatour, PhD

Auto HbA1C ANALYZER HbA1LC HPLC 3660

Certificate of Analysis JCCRM 811-1

College of American Pathologists (CAP) GH2 Survey Data: (updated 12/09) 2009 GH2-B (fresh pooled samples) * = NGSP certified at the time of the survey

HbA 1c Measurement by IDMS Current Situation and Future Development

1 Introduction Imprecision Within-run imprecision, results Day-to-day imprecision, results... 2

Biochemistry Adult Reference Ranges

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee

Commentary by R. Little, Ph.D., NGSP Network Coordinator for the NGSP Steering Committee

State of the Art of HbA1c Measurement

Serum LDL- and HDL-cholesterol determined by ultracentrifugation and HPLC

CDC s Clinical Standardization Programs

External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA -

Chemical Metrology for Human Health Assessment

Serum low-density lipoprotein and high-density lipoprotein cholesterol. determined by ultracentrifugation and high-performance liquid

Accuracy and Precision in Point-of-Care Lipid Testing: CardioChek P A Point-of-Care Test System and PTS Panels Test Strips

REVIEW Global standardisation of HbA 1c

Towards Improved Reliability in Laboratory Medicine. Universal Metrological Traceability

Estimation of glucose in blood serum

Hemoglobin A1c: Comparison of Pointe Scientific s 2-Part Direct Hemoglobin A1c with the Bio-Rad Variant II and the Tosoh G8

SCIEX Vitamin D 200M Assay for the Topaz System

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

Traceable lipoprotein counting for Cardiovascular disease risk assessment Vincent DELATOUR, PhD

Optimized for best performance in clinical chemistry testing

Walter B. Bayubay CLS (ASCP), AMT, MA Ed, CPI

Defining HbA1c: the indispensable decision to approach measurement standardization

Tosoh Automated Glycohemoglobin Analyzer HLC-723GX

General Chemistry Scheme Guide

Bio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c

Documentation, Codebook, and Frequencies

Free Fatty Acid Assay Kit (Fluorometric)

High-density Lipoprotein Cholesterol (HDL-C) Assay Kit

Worksheet. Worksheet. Worksheet. Worksheet. Student Performance Guide. Student Performance Guide

Metabolomics: quantifying the phenotype

1. PROTOCOL. Comparison Study Summary. Tuality Healthcare 324 SE 9 th Ave. Suite E Hillsboro, OR July 30, 2014

Excellence and confidence

Thermo Scientific System Reagents Excellence in Clinical Chemistry

Free Glycerol Assay Kit (Colorimetric)

HbA1c enzymatic assay evaluation at AN academic

Effect of lecithin: cholesterol acyltransferase on the formation of cross-linked apolipoprotein A-I

ab65390 HDL and LDL/VLDL Cholesterol Assay kit

MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels

Metabolic Monitoring Point of Care Testing

Measuring Lipid Composition LC-MS/MS

Instructions Fast Before Cholesterol Test How Long Must You Have

Lecithin Cholesterol Acyltransferase (LCAT) ELISA Kit

AF HDL and LDL/VLDL Assay Kit

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Evaluation of haemoglobin A1c measurement by an enzymatic method using an automated analyser that has an on-board haemolysis system

CCQM-K6: Key Comparison on the Determination of Cholesterol In Serum* Final Report December 2001

Evaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser

Smart Diagnostics for Point-of-Care!

Clinical Chemistry Reagents Brochure

Comparison of two assays for measuring LDL cholesterol

AAP Lead Testing Webinar Series

3 Linearity and Detection Limit Linearity Detection limit... 4

Bias in clinical chemistry. Elvar Theodorsson EFLM and Linköping University

Evaluation of Calculated Low-Density Lipoprotein Against a Direct Assay

BCH 447. Triglyceride Determination in Serum

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

POC Testing: The New Standard. InnovaStar From DiaSys.

Clinical Chemisty Reagents Brochure. ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics. Central Laboratory

The analytical phase

Why do we need SD LipidoCare?

Improving the Accuracy of Hemoglobin A 1c. : Your Help Is Needed

Lipid Quantification Kit (Colorimetric)

Journal of Chemical and Pharmaceutical Research

ARTICLE. Utility of Direct Measurement of Low-Density Lipoprotein Cholesterol in Dyslipidemic Pediatric Patients

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

ab65390 HDL and LDL/VLDL Cholesterol Assay Kit (Colorimetric/ Fluorometric)

Standardization of. S.M.Boutorabi DCLS,PhD

Harmonization of laboratory results by data adjustment in multicenter clinical trials

1. Reagent Store at 2-8 ºC.

Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research

Determination of Iodine in Biological Materials using Instrumental Neutron Activation and Anti-coincidence Gamma-ray Spectrometry

Bioequivalence Studies of Two Formulations of Famciclovir Tablets by HPLC Method

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Enzymatic Analysis for Food and Feed

Biocard. 1. Troponin I

HbA1c and Diabetes. Steven Weier Senior Lecturer School of Biomedical Sciences Faculty of Health QUT. CRICOS No J

Thermo Scientific Konelab System Reagents For convenient and reliable analysis

Patient: 55 y female (ambulatory)

Biomedical Research 2017; 28 (4):

Neosolaniol. [Methods listed in the Feed Analysis Standards]

The setup and validation of an LC-MS/MS assay of Androstenedione & Testosterone a labs experience

CHAPTER FORTY FIVE ENDOGENOUS LIPID TRANSPORT PATHWAY: VLDL AND IDL

IFCC in its 60 th YEAR Achievements and Future Opportunities. Mathias M. Müller

Chapter (5) Etiology of Low HDL- Cholesterol

Serum Triglyceride Quantification Kit (Colorimetric)

Shinichi Usui, 1 Masakazu Nakamura, 2 Kazuhiro Jitsukata, 3 Masayuki Nara, 4 Seijin Hosaki, 1 and Mitsuyo Okazaki 4*

Transcription:

Biochemistry & Fundamental Reference Laboratory, Yokohama Our Head Office and Biochemistry Reference Laboratory moved to Yokohama with aims to have further development on the 21 st September, 2018. [Reference Measurement Laboratory of ReCCS], performs three laboratory functions together, the following are descriptions of these laboratory functions. Biochemistry Reference Laboratory, Introduction This lab opened in 1995 and, although it has been in operation for 19 years, the laboratory remains mostly unchanged from the view when it started. Electrolyte Analyzer with Ion-Selective Electrode and Blood Gas analyzer

The first reference material introduced by ReCCS was for ISE (Na, K, Cl) use. They are still popular even though it has passed more than 20 years since Na, K, and Cl first became available. The electrolyte analyzer with ion-selective electrode is currently only used for examining the characteristics of reference materials and, thus, it is never used to determine the certified values of reference materials. HPLC for Lipoprotein analysis HbA1c, lipids, and electrolytes are the three main reference materials of ReCCS. Lipids, including Total Cholesterol, HDL-C, LDL-C, Triglyceride, and Total Glycerides are certified. High performance liquid chromatography (HPLC) with an ion-exchange column (see the upper photo) is used for analyzing lipoproteins where VLDL, IDL, HDL, and LDL can be quantitated. By combining post-column colorimetric method for cholesterol with the HPLC, each lipoprotein cholesterol can be quantitated. Ultracentrifuge

A Beckman Ultracentrifuge, shown above, is an essential instrument for performing the BQ method developed by the Centers for Disease Control and Prevention (CDC). The laboratory of ReCCS is equipped with swing rotors and angle rotors, necessary for the separation of lipoproteins by ultracentrifugation according to the Hatch and Lees protocol. Quantification of HDL-C and LDL-C by the method performed at CRMLN is done by first overlaying liquid with a density of 1.006 kg/l on top of serum, followed by ultracentrifugation. The amount of cholesterol in the bottom fraction is then quantitated by the AK method. Next, LDL is precipitated by the Heparin-Mn precipitation method, while the amount of HDL-C is measured in the supernatant. The amount of LDL-C is calculated by subtracting the amount of HDL-C from the amount of cholesterol in the bottom fraction. Precise values cannot be obtained for samples that contain VLDL remnants by the ultracentrifugation method described above. Furthermore, values obtained by the CDC BQ method cannot be reproducible if unless conditions are kept consistent. National Cerebral and Cardiovascular Center certifies reagents and methods for lipids analysis in Asia. High Separation PAGE Electrophoresis Apparatus The picture above shows the Lipo Print by Quantimetrix Co. Lipo Print is a PAGE electrophoresis apparatus. The PAGE electrophoresis apparatus is known to give a higher separation capacity than conventional methods and is useful for examining in advance whether a pool of serum samples, used for the preparation of JCCRM 223 and 224 lipoprotein cholesterol reference materials, contains a serum sample with abnormal lipids.

Standard Spectrophotometer A molar absorbance coefficient is applied for the Cyanomethemoglobin method defined by the International Council for Standardization in Hematology (ICSH). Therefore, traceability of precise values of temperature, cuvette length(10.0 mm), and wave length are prerequisite. The standard spectrophotometer used at this laboratory is able to maintain a constant temperature in the cuvette using circulating water with constant temperature. Traceability of temperature, wavelength, and cuvette length as well as spectroscopic accuracy is all guaranteed by the use of the standard spectrophotometer of this institute. This spectrophotometer can also be used for measuring enzymatic activity. Thermal Ionization Mass Spectrometer For measuring the amount of K in serum primary reference materials by an ion-selective electrode, thermal ionization mass spectrometry, which currently gives the highest possible accuracy, is used.

At present, ReCCS is the only institute that uses this technique in the world. NIST has shifted to ICP-MS. It will take 10 years of experience to master the isotope-dilution thermal ionization mass spectrometry. The picture above shows a high performance furnace used for decomposition of protein in serum for analyzing the amount of Na and K in a serum sample. High performance balance The balance, which can certainly measure to 0.1mg, is placed on an aseismic plate where it is not affected by static electricity, nor subtle vibration. Standard materials used for spectrophotometer calibration

Weight standards Platinum Resistance Thermometer A certified platinum resistance thermometer is prerequisite for the traceability of cuvette temperature. This standard platinum resistance thermometer is officially calibrated every year to be used for the calibration of thermistor thermometers.

[IFCC network laboratory] ReCCS is a designated IFCC (International Federation of Clinical Chemistry and Laboratory Medicine) network laboratory for HbA1c and FT4. Our laboratory also conducts other measurements using methods on the list of reference measurement procedures described in JCTLM (Joint Committee on Traceability in Laboratory Medicine) methods. Laboratory Introduction Reference Material Institute for Clinical Chemistry Standards implement below: 1. The IFCC HbA1c measurement method (according to the IFCC reference measurement method) ReCCS is a JCTLM certified reference laboratory for HbA1c measurement as well as an IFCC HbA1c network laboratory. There are only 3 such laboratories in the world which have the capability for both of these functions. 2. Isotope Dilution Mass Spectrometry (ID-MS) measurement method Our laboratory conducts measurements using ID-MS, a reference measurement method. Total cholesterol, total glyceride, free glycerol, triglyceride, uric acid, glycoalbumin, etc. are measured in our laboratory. 3. Hormone measurement method Along with the international standardization of thyroid hormone measurement determined by the working group in IFCC, our laboratory is designated as a

reference laboratory which conducts reference analysis of free T4 in blood (Equilibrium dialysis - Isotope Dilution Mass Spectrometry (ID-MS) analysis). [NGSP Reference Laboratory] The Reference Material Institute for Clinical Chemistry Standards (ReCCS) is Asian Secondary Reference Laboratory (ASRL#1) of the National Glycohemoglobin Standardization Program (NGSP), which used NGSP certification tests. The KO500 method for measuring HbA1c, which is conducted at ASRL#1, is traceable to the reference method of the Diabetes Control and Complications Trial (DCCT) of which tracability was verified by CPRL. The CPRL conducts a monitoring comparison test for the KO500 method each month.

ASRL#1 conducts manufacturer certification and laboratory certification (level I and II) tests.. The number of certified routine methods were as many as 57 methods at ASRL#1 in 2014. The Reference Material Institute for Clinical Chemistry Standards (ReCCS) is a primary reference laboratory(prl) of NGSP. Primary Reference Laboratories (PRLs) of NGSP are constituted by CPRL, PRL/USA, EPRL/Europe, and APRL/Asia. In case of troubles in CPRL, other PRLs back up CPRL. The laboratory reproduces Bio-Rex 70 HPLC, which was used as the reference in DCCT and UKPDS. The uniqueness of this reference method is that the ratio of the area between HbA1c and HbAo corresponds to the DCCT value. Of course, calibrators are needed to confirm whether bias does not occur. These DCCT calibrators are supplied to each PRL from NGSP. ReCCS was nominated and passed the criteria of APRL (on April 2015), and has played a role in maintaining the standards of DCCT and UKPDS.