IMPLANT NAVIGATION WITH THE TEMPLATE TECHNIQUE IN SEVERE BONE ATROPHY TEAM PLANNING FOR PREDICTABLE RESULTS

Similar documents
Oral Rehabilitation with CAMLOG implants after loss of dentition due to an accident

Locator retained mandibular complete prosthesis (isy Implant System)

Safety and esthetics with

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

From planning to surgery: a totally digital working flow for Leone implants placement

isy indications and techniques

Featured Patient Case #1: Complete Mouth Reconstruction with Hybrid Restorations

DIGITAL DIAGNOSIS AND TREATMENT PLANNING FOR PLACEMENT AND RESTORATION OF SINGLE IMPLANTS IN THE POSTERIOR MAXILLA By Timothy Kosinski, DDS

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

GuidedService. The ultimate guide for precise implantations

Devoted to the Advancement of Implant Dentistry

Yxoss CBR Customized Bone Regeneration CAD/CAM Technologies for Tailor-Made Bone Regeneration

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Conus Concept: A Rewarding Complete Denture Treatment

IMPRESSION PROCEDURES TRAINING MANUAL

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Implant restoration in the aesthetic zone using guided surgery and immediate functional loading

INTERNATIONAL MEDICAL COLLEGE

Prosthodontic Procedure

Guided implant placement using the trephine drill nonsleeve and immediate provisional crown or bridge in the esthetic zone

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

SCD Case Study. Implant-supported overdentures

a perfect fit CAMLOG GUIDE SYSTEM Planning, template fabrication and implantation

Long-term success of osseointegrated implants

An Introduction to Dental Implants

The Use of Alpha-Bio Tec's Narrow NeO Implants with Cone Connection for Restoration of Limited Width Ridges

ident CT Guide Protocol

DIOnavi. Brochure Ver.2. Product Introduction: DIOnavi. Clinical Case Report

Element-Z Screw-Retained Hybrid

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

The removable implant supported prosthesis for the upper jaw

Implant Studio Patient Case

Contemporary Implant Dentistry

Full mouth rehabilitation with digital workflow

Flapless, Immediate Implantation & Immediate Loading with Socket Preservation in the Esthetic Area Using the Alpha-Bio Tec's NeO Implants

For technical assistance: Tel Working time: 8.30 am pm

CHECK-UP Determination of Impression type & Method after implant placement

Implant Restorations: A Step-By-Step Guide

Mini implants for Stabilization of partial dentures

Screw retained implant crown restoration with digital workflow using scan body and surgical guide

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Mechanical and technical risks in implant therapy.

WHERE CREATIVITY MEETS TECHNOLOGY E CREATECH EXCELLENCE. State-of-the-art technology for your prostheses

and you can smile again.

Simplant. Guided Surgery. delivering restorative driven implant treatment

Inclusive Tooth Replacement System

- RESTORATIVE PRODUCT CATALOG

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

Straumann SmartOne. Stage 4 Af terc are and maintenance. Step 2 Maintenance visit

PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014

MIMI (Minimally Invasive Method of Implantation) with Immediate Loading of a One- Piece Champions Implant Square New Art to Replace a Central Incisor:

Prosthetic Options in Implant Dentistry. Hakimeh Siadat, DDS, MSc Associate Professor

OCCLUSALLY SCREW-RETAINED

Fig. 2: The initial clinical situation is characterized by gaps between the upper and lower anterior teeth.

CAMLOG IMPLANT SYSTEM PRODUCT CATALOG

Controlling Tissue Contours with a Prosthetically Driven Approach to Implant Dentistry

Contents Graduate Diploma of Dental Implantology

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

a perfect fit INSTRUCTION MANUAL CAMLOG TORQUE WRENCH WITH CONTINUOUS TORQUE ADJUSTMENT Handling Sterilization Care

A Novel Technique for the Management of a Maxillary Anterior Alveolar Defect with an Implant-retained Fixed Prosthesis: A Clinical Report

More than a beautiful smile. A new quality of life with dental implants.

Optimizing Lateral Incisor Function and Esthetics with the Hahn Tapered Implant System

CAMLOG. IMpLAnt SYSTEM INTERNATIONAL. Valid from March 2011

The WeldOne Concept. handcrafted excellence in modern dentistry. Competence in Instruments MADE IN GERMANY

ZIRCONIUM OXIDE MEETS SINTERING METAL

Rehabilitating a Compromised Site for Restoring Form, Function and Esthetics- A Case Report

Immediate fixed teeth a treatment concept for edentulous patients

Guided immediate loading implant surgery planned with Implant Studio D.D.S. Jae-min, Lee

Ankylos. Laboratory Manual

Creating emergence profiles in immediate implant dentistry

Dental Implants: A Predictable Solution for Tooth Loss. Reena Talwar, DDS PhD FRCD(C) Oral & Maxillofacial Surgeon Associate Clinical Professor

a perfect fit CAMLOG IMPLANT SYSTEM PRODUCT CATALOG CAMLOG IMPLANT SYSTEM PRODUCT CATALOG SEPTEMBER 2014

Rehabilitation of Resorbed Mandibular Ridge with Implant Supported Overdenture- A Clinical Report

Generation fifty plus: Restoring a natural smile

US Implant System 2013 PROSTHETIC PROCEDURE

Strong bone for beautiful teeth. Patient Information I Bone reconstruction with Geistlich Bio-Oss and Geistlich Bio-Gide

A Clinician s Guide to Restoring Conus

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

2015 Member Speaker Forum. Chair: L. Scott Brooksby, DDS, BS. Friday, October 23, :30 AM 3:45 PM. Coral Ballroom. 3.

BUILDING A. Achieving total reconstruction in a single operation. 70 OCTOBER 2016 // dentaltown.com

Chapter 12. Prosthodontics

SPECIALIST IN CUSTOMIZED PROSTHETICS

Socket preservation in the daily practice: A clinical case report

Xive. Product Catalog

Lisbon, Portugal Dr. Gonçalo Seguro Dias

Use of Technology for Improved Implant Use in The OMS Practice AAOMS 93rd Annual Meeting, Philadelphia, PA

Replacement of a missing posterior tooth in the mandible (isy by CAMLOG)

Periimplant Regeneration Fenestration

Restorative Driven Implant Solutions Utilizing the Latest Technology

Removable Partial Dentures

PHILOSOPHY SWISS QUALITY PERFORMANCE

Guided surgery as a way to simplify surgical implant treatment in complex cases

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

surgical and prosthetic options & impression technique overview

Narrow-diameter implants in premolar and molar areas

Transcription:

CASE REPORT 06 2010 IMPLANT NAVIGATION WITH THE TEMPLATE TECHNIQUE IN SEVERE BONE ATROPHY TEAM PLANNING FOR PREDICTABLE RESULTS Dr Andres Stricker, Master Dental Technician Steffen Rothacher Konstanz, Germany PROSTHETICS Dr Andres Stricker practices privately as an oral surgeon at the Center of dental Implantology, Periodontology, and 3D head- and neck Imaging in Konstanz. He is also involved in teaching and research at the Hospital and Clinic for Oral and Maxillofacial Surgery at Freiburg University Hospital and is a lecturer at Danube University Krems in Austria. He holds degrees in medicine and dentistry from the Albert Ludwig University in Freiburg. Various research visits followed at the University of Michigan, Harvard University, the University of Louisville, and the University of Miami. His specialist training was completed at the Hospital and Clinic for Oral and Maxillofacial Surgery in Freiburg. Dr Stricker has worked in implantology since 1997 and has authored numerous publications on topics such as distraction, immediate loading, augmentation procedures, soft-tissue management, tissue engineering, and stem cell regeneration. He has also been responsible for several developments and patents, e.g., the V-2 Distractor and many instruments in the field of implantology. He lectures at national and international conferences and courses. Master dental technician Steffen Rothacher trained to become a dental technician from 1989 1992. In 2002, he passed his master's examination in Frankfurt am Main. Since then, he has been managing his own dental laboratory in Bad Saulgau. He is a certified specialist in implant dentistry and esthetic dentistry. He works as a consultant for various firms. IMPLANTS USED Tooth Impl. type Impl. length Impl. Ø Impl. surface 48 47 46 45 44 43 42 41 31 32 33 34 35 36 37 38 SL SL SL SL 13.0 13.0 13.0 13.0 3.8 3.8 3.8 3.8 P P P P standard platform switching removable fixed crown bridge cement-retained screw-retained partially edentulous edentulous others Universal abutment Esthomic abutment Telescope abutment Gold-plastic abutment Ceramic abutment Individual zirconium abutment on titanium base Logfit abutment Locator abutment Ball abutment Bar abutment Vario SR abutment others Impl. type: ROOT-LINE (RL) / SCREW-LINE (SL) Impl. surface: Promote (P) / Promote Plus (PP)

Case Report 06 2010 INFORMATION ON PATIENT AND TREATMENT The 68-year-old female patient presented with a wish for improved retention of her removable dental prosthesis after extraction of teeth 34 and 35, that could not be preserved. The goal was a template-guided and template-navigated implant insertion created with a threedimensional data set and planned from a prosthetic standpoint in order to enable an implant-borne telescopic restoration, that would be as minimally invasive as possible for the patient despite severe bone atrophy. Threedimensional volume tomography (3D-VT) was prepared with the aid of a scan template. The intraoperative navigation template could then be fabricated in a lab with the aid of this virtual 3D plan. The basic aim here was an optimal implementation of the planning coordinates from the information provided by the planning scan template up to the desired implant position, which was adapted from the X-ray template into the drilling template with the aid of a special drilling bench. After a vertical crest reduction had been carried out, four CAMLOG SCREW-LINE implants were inserted via template-guided navigation and laterally augmented on both sides. In the present case, transversal divergence led to a decision to firstly load the inserted implants temporarily for two months via the gingiva formers as part of progressive bone loading and only then insert the prosthetic appliance. Because securely fitting an implant drilling template supported only on the mucous membrane is problematic in an edentulous jaw, temporary implants were inserted as reference pins before the main implant insertion. Pre-operative condition with remaining teeth not worth preserving Fig. 1: Pre-operative condition with extremely loose teeth and insufficient prosthesis retention. Tooth 43 previously had to be surgically removed due to a transverse fracture. Fig. 2: With the prosthesis anchored on one side, the remaining teeth had been severely loosened. Fig. 3: The extremely loose teeth 33 and 34 were extracted without any trauma. Temporary implants for secure referencing of the navigation template Fig. 4: Immediately after that, the temporary implants were inserted as reference pins. Fig. 5: Postoperative OPG after tooth extraction and insertion of temporary implants. Fabrication of the scan template after a wax-up with a prosthetic focus Fig. 6: The lab versions of the temporary implants (Mini Sky, Bredent) on the model. They are used to fix the bite plate, set-up and DVT template. With these tools, positional stability and secure retention of various templates can always be guaranteed in an edentulous jaw. Fig. 7: The mandibular set-up on the model. It is used for initial orientation of the occlusal position as well as esthetics. Fig. 8: The DVT template (Med 3D) fabricated with the set-up and with three reference points (guttapercha pins bilaterally in Region 3 and a Lego brick) to prevent any transfer errors. Fig. 9: The occlusal stops for fixing the position of the DVT template. Another factor to prevent movements during recording.

Navigation planning based on the DVT data set Fig. 10: Digital volume tomography (icat) with scan template idealized from a prosthetic standpoint. Prosthetic planning can be correlated with the anatomical situation here. Fig. 11: The implant position is precisely planned with the virtual navigation software (Med3D). Fig. 12: With an altered drilling template, the secure template-guided pilot hole can now be made intraoperatively with the CAMLOG Guide System. Template-guided preparation of the implant bed Fig. 13: View of the navigation template, which was fabricated with virtual planning based on the scan template. Fig. 14: Further template-guided preparation of the implant bed with the CAMLOG Guide System. Fig. 15: Template-navigated implant insertion through the sleeve of the navigation template. Securely guided implant insertion Fig. 16: The insertion instrument's depth stop prevents the implant from being inserted too high or too deep. Fig. 17: Postoperative picture before removal of the navigation template. Fig. 18: Condition after surgical implant insertion in accordance with optimal prosthetic criteria. Buccal crest augmentation Fig.19: In this buccal view, it is clear that there is not enough bone thickness around the inserted implants. Augmentation must be carried out to achieve longterm stability. Fig. 20: The augmentation is performed by adding bone chips scraped together from the surrounding area and a bovine bone replacement material (Bio-Oss ) directly onto the implant surface. Fig. 21: For secure position stabilization of the particular material, the augmentation material is covered with a collagen membrane (Bio-Gide ).

Case Report 06 2010 Transgingival implant healing Direct postoperative implant impression Fig. 22: Condition after suture closure around the healing caps. Fig. 23: Postoperative OPG. Fig. 24: The impression posts, screwed in for an initial closed impression. A therapeutic temporary restoration was fabricated with the aid of this initial impression. It was left in situ until the implants could be fully loaded. Fig. 25: For the impression taken immediately after surgery, the wound should be covered with rubberdam. Fig. 26: The concluding set-up for planning the final restoration. Fig. 27: Soft-tissue healing after 2 weeks. Fig. 28: The screwed-in cones (2 degrees); these were fabricated with the aid of gold-plastic abutments. The length of the friction surfaces should not be less than 5 mm to ensure adequate friction of the electroformed secondary parts. Insertion of the prosthetic suprastructure Fig. 29: X-ray check 2 weeks after implant insertion. Fig. 30: Intraoral cementing of the electroformed caps with the tertiary structure. Any transfer errors can be eliminated with this procedure. Fig. 31: The mandibular cone prosthesis immediately after insertion. With consistent cementing in the mouth, there were no stresses or excessively high retention forces whatsoever on the implants. Fig. 32: The permanently seated maxillary total denture and mandibular cone prosthesis with individually fired porcelain teeth in the anterior and custom shading of the plastic gingival base. Fig. 33: X-ray check 12 months after implant insertion with stable periimplant bone.

CONCLUSIONS These days, implant dentistry is no longer just about bone availability, but constitutes an overall concept, which aims at complete functional and esthetic restoration of a patient's lost chewing function, without losing sight of the total restoration's long-term stability. Thorough and clearsighted planning, in other words backward planning, is needed for this. There must be perfect cooperation between the surgeon, prosthodontist, and dental technician, and optimal on-screen prosthetic planning must be implemented intraoperatively with the aid of an implant drilling template. Nowadays, high-resolution three-dimensional diagnostic procedures using sectional images such as digital dental volume tomography (DVT) and optimized 3D planning software are available for this. Esthetically and functionally complex problems can thus be solved with maximum possible precision. With temporary implants, it is possible to predictably create precise reference points in an edentulous maxilla and mandible so that the guide template cannot be misaligned, ensuring that there will be no relevant deviations during surgical implant insertion. Thanks to this reliable planning, largely predictable results and long-term stability of implants can successfully be achieved. Virtually planned and template-guided implantation allows precise implant insertion and thus creates optimal conditions for a successful prosthetic rehabilitation with the help of a functioning network between the surgeon, prosthodontist, and dental technician. Pre-operative condition Fig. 34: Pre-operative condition with extremely loose teeth and insufficient prosthesis retention. Fig. 35: Postoperative OPG after tooth extraction and insertion of temporary implants. Situation 12 months after implant insertion Fig. 36: View of the functionally and esthetically redesigned prosthetic restoration. Fig. 37: X-ray check 18 months after implant insertion.

Case Report 06 2010 NOTES

REFERENCES LUEBBERS HT, MESSMER P, OBWEGESER JA, ZWAHLEN RA, KIKINIS R, GRAETZ KW, MATTHEWS F Comparison of different registration methods for surgical navigation in craniomaxillofacial surgery. J Craniomaxillofac Surg. 2008 Mar;36(2):109-16. Epub 2008 Feb 14. SEMPER W, KRAFT S, KRÜGER T, NELSON K Theoretical optimum of implant positional index design, J Dent Res. 2009 Aug;88(8):731-5. MARQUARDT P, WITKOWSKI S, STRUB J Three-dimensional navigation in implant dentistry, Eur J Esthet Dent. 2007 Spring;2(1):80-98. CONTACT Dr. Dr. Andres Stricker Center of dental Implantology, Periodontology and 3D head-and-neck Imaging Wessenbergstrasse 6 D-78462 Konstanz www. impla-paro-3d.de Master Dental Technician Steffen Rothacher Zahntechnisches Labor GmbH Werderstrasse 3 D-88348 Bad Saulgau www.rothacher.eu WIDMANN G, WIDMANN R, WIDMANN E, JASCHKE W, BALE R Use of a surgical navigation system for CT-guided template production, Int J Oral Maxillofac Implants. 2007 Jan-Feb;22(1):72-8. MISCHKOWSKI RA, ZINSER MJ, NEUGEBAUER J, KÜBLER AC, ZÖLLER JE Comparison of static and dynamic computer-assisted guidance methods in implantology, Int J Comput Dent. 2006 Jan;9(1):23-35. KRAMER FJ, BAETHGE C, SWENNEN G, ROSAHL S Navigated vs. conventional implant insertion for maxillary single tooth replacement., Clin Oral Implants Res. 2005 Feb;16(1):60-8. CASAP N, WEXLER A, PERSKY N, SCHNEIDER A, LUSTMANN J Navigation surgery for dental implants: assessment of accuracy of the image guided implantology system., J Oral Maxillofac Surg. 2004 Sep; 62(9 Suppl 2):116-9. WANSCHITZ F, BIRKFELLNER W, WATZINGER F, SCHOPPER C, PATRUTA S, KAINBERGER F, FIGL M, KETTENBACH J, BERGMANN H, EWERS R Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible., Clin Oral Implants Res. 2002 Feb;13(1):59-64. SUPPLIERS Geistlich Biomaterials Wolhusen Mini Sky,Bredent: bredentgmbh & Co.KG,Senden Med 3D: med3d GmbH, Heidelberg icat: i-cat,imaging Sciences,Hatfield,USA Ergoplant Instruments: Aesculap AG Tuttlingen ACKNOWLEDGMENTS Master Dental Technician Steffen Rothacher Bad Saulgau: Dental Engineering Dr Ernst Luft Sigmaringen: Prosthetics Dr Jonathan Fleiner Konstanz: Assistance Master Dental Technician Gerhard Neuendorf Filderstadt: Navigation Planning

HEADQUARTERS CAMLOG Biotechnologies AG Margarethenstrasse 38 CH-4053 Basel Schweiz Telefon +41 61 565 41 00 Fax +41 61 565 41 01 info@camlog.com www.camlog.com