Supporting information

Similar documents
A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

LC-MS/MS Method for the Determination of Tenofovir from Plasma

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

Determination of Chlorophenoxyacetic Acid and Other Acidic Herbicides Using a QuEChERS Sample Preparation Approach and LC-MS/MS Analysis

An optical dosimeter for the selective detection of gaseous phosgene with ultra-low detection limit

Determination of Amantadine Residues in Chicken by LCMS-8040

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

SUPPLEMENTARY INFORMATION. Direct Observation of the Local Reaction Environment during the Electrochemical Reduction of CO 2

Fatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Supporting Information

Sulfate Radical-Mediated Degradation of Sulfadiazine by CuFeO 2 Rhombohedral Crystal-Catalyzed Peroxymonosulfate: Synergistic Effects and Mechanisms

Authors. Abstract. Introduction. Environmental

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ MS

Lipidomic Analysis by UPLC-QTOF MS

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Ozonolysis of phospholipid double bonds during electrospray. ionization: a new tool for structure determination

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Analytical Method for 2, 4, 5-T (Targeted to Agricultural, Animal and Fishery Products)

California TOF/QTOF Users Meetings: MS Settings. Jim Lau, Agilent Technologies.

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Comparison of a UPLC Method across Multiple UHPLC Systems

SUPPLEMENTARY MATERIAL

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Designer Fentanyls Drugs that kill and how to detect them. Cyclopropylfentanyl

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Peak Analysis using Cumulative Peak Fitting:

ApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.

Application of a new capillary HPLC- ICP-MS interface to the identification of selenium-containing proteins in selenized yeast

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Results of Using Re-washed Vials and Closures

International Journal of Applied Pharmaceutical Sciences and Research

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

Reaction Screening and Optimization of Atropine Synthesis in Continuous-Flow Guided by Preparative Electrospray

Dienes Derivatization MaxSpec Kit

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

2D-LC as an Automated Desalting Tool for MSD Analysis

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

Profiling Flavonoid Isomers in Highly Complex Citrus Juice Samples Using UPLC Ion Mobility Time-of-Flight Mass Spectrometry

Supporting information

Sample Concentration and Analysis of Human Hormones in Drinking Water

International Journal of Applied Pharmaceutical Sciences and Research

Electronic supplementary material to: The influence of L-carnitine on the formation of preneoplastic and

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Fizzy Extraction of Volatile and Semivolatile Compounds into the Gas Phase

A Facile Method for Enhancing the Sensing Performance of Zinc Oxide. Nanofibers Gas Sensors

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

SUPPLEMENTARY INFORMATION

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Quantification of PtdInsP 3 molecular species in cells and tissues by mass spectrometry

Mass Spectrometry. Actual Instrumentation

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Application Note. Author. Abstract. Introduction. Food Safety

Supplementary Information

Solid Phase Peptide Synthesis (SPPS) and Solid Phase. Fragment Coupling (SPFC) Mediated by Isonitriles

Small Scale Preparative Isolation of Corticosteroid Degradation Products Using Mass-Based Fraction Collection Application

Supporting Information

Steviol Glycosides from Stevia rebaudiana Bertoni

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Uptake and Metabolism of Phthalate Esters by Edible Plants

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium. Application. Authors. Abstract.

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Efficient and green, microwave assisted synthesis of haloalkylphosphonates via Michaelis-Arbuzov reaction

Identification of Steroids in Water by Ion Trap LC/MS/MS Application

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Direct determination of MCPD esters and glycidyl esters by LC-TOFMS

Increased Identification Coverage and Throughput for Complex Lipidomes

Supporting Information

ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate

Determination and pharmacokinetics of manidipine in human plasma by HPLC/ESIMS

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Impurity Profiling of Carbamazepine by HPLC/UV

Transcription:

1 2 3 Supporting information SO 2 Uptake on Oleic Acid: A New Formation Pathway of Organosulfur Compounds in the Atmosphere 4 5 Jing Shang, Monica Passananti, Yoan Dupart, Raluca Ciuraru, Liselotte Tinel, Stéphanie Rossignol, Sébastien Perrier, Tong Zhu, Christian George * 6 7 8 State Key Joint Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences and Engineering, Peking University, 9 Beijing, 100871, People s Republic of China 10 11 12 13 Université Lyon 1, CNRS, UMR 5256, IRCELYON, Institut de recherches sur la catalyse et l environnement de Lyon, 2 avenue Albert Einstein, F-69626 Villeurbanne, France 14 15 These authors have contributed equally to this work. 16 * E-mail: christian.george@ircelyon.univ-lyon1.fr 17 18 1

19 1. HETEROGENEOUS UPTAKE OF SO 2 ON ORGANIC FILMS 20 1.1 Calculation of film thickness 21 22 The thickness of organic films was calculated by assuming that the film was coating homogeneously all the available surface, according to the follow equation: 23 TThiiiiiiiiiiiiii = mm ρss (1) 24 25 where m is the mass of organic compound inside the tube, ρ is the density of organic compound (0.887 g ml -1 for oleic acid) and S is the inner surface area of the tube. 26 27 1.2 Uptake coefficient 28 29 30 The measurement of the uptake coefficient (γ) was conducted by observing the decay of SO 2 concentration as a function of the injector position i.e., of the interaction time. The SO 2 concentration decay was found to obey first-order kinetics: 31 ln CC 0 CC tt = kk oooooo tt (2) 32 33 34 35 where C 0 represents the initial SO 2 concentration, C t is the concentration of SO 2 at reaction time t, and k obs is the observed first-order loss rate constant. The uptake coefficient (γ) is defined as the ratio of the molecules removed from the gas phase to the total gas surface collisions and was calculated according to equation (3): 1, 2 36 γγ = 2rrkk oooooo ωω (3) 2

37 38 39 40 where r is the radius of the flow tube (here 0.006 m) and ω is the mean molecular velocity of SO 2 (312 m s -1 ). The uptake coefficient was determined using the geometric surface area of the coated glass tube and the gas phase diffusion correction was negligible. 41 42 The uptake coefficients at different initial SO 2 concentrations, humidity and OA mass conditions are reported below (Table S1). 43 3

44 45 46 Table S1. Summary of uptake coefficient measurements of SO 2 on oleic acid at different SO 2 concentration, RH and oleic acid mass conditions. Parameters SO 2 concentration ( 10 12 molecules cm -3 ) RH(%) Oleic acid mass (mg) k (s -1 ) R 2 * γ ( 10-6 ) 0.3 7 6.6 0.104 0.9944 4.00 0.6 7 6.0 0.093 0.9957 3.58 1.1 6 5.0 0.088 0.9788 3.38 Different SO 2 concentration 2.2 6 7.7 0.072 0.9895 2.79 4.3 7 6.2 0.049 0.9459 1.89 7.0 6 5.0 0.033 0.9137 1.27 11.3 6 6.0 0.024 0.9501 0.92 2.3 2 5.2 0.084 0.9827 3.22 2.2 20 6.8 0.101 0.9952 3.87 Different RH 2.2 50 6.3 0.127 0.9915 4.87 2.3 74 8.0 0.162 0.9925 6.21 Different oleic acid 2.1 4 5.7 0.133 0.9942 5.10 4

Parameters SO 2 concentration ( 10 12 molecules cm -3 ) RH(%) Oleic acid mass (mg) k (s -1 ) R 2 * γ ( 10-6 ) mass 2.0 3 10.3 0.160 0.9962 6.17 2.1 3 17.4 0.134 0.9923 5.17 2.1 3 21.6 0.146 0.9921 5.60 2.1 3 23.7 0.168 0.9968 6.44 2.1 3 24.4 0.141 0.9963 5.42 2.1 3 28.0 0.158 0.9975 6.07 2.0 3 42.4 0.148 0.9963 5.69 47 Experimental conditions: flow rate = 300 ml min -1 and T = 293~294 K. 48 * R 2 is the correlation coefficient of the line ln (C 0 /C t )~t. 49 5

50 1.3 Coated flow tube experiments 51 52 53 54 55 56 57 58 59 60 61 62 63 64 The flow reactor is a temperature-controlled double-walled cylindrical Pyrex tube, 22 cm in length. At the outlet of the flow tube, the temperature and relative humidity (RH) were monitored by a temperature and humidity sensor (Sensor-tec, UFT75 Sensor). A schematic representation of the coated-wall flow tube is shown in Figure S1. The SO 2 gas phase concentration and the relative humidity RH were adjusted by regulating the mixing ratios between an SO 2 standard gas tank flow (Linde France S.A., SO 2 in N 2, SO 2 concentration 10.31 ppm), a water-saturated airflow and a dry airflow (Linde France S.A., synthetic air, purity 99.9990%) using mass flow controllers. The water-saturated airflow was provided by bubbling the carrier gas in water in a humidifier at 293 ± 1 K. The gas flow was introduced into the flow tube through a horizontal movable injector. The position of the injector was adjusted to vary the interaction length between 3.3 and 19.8 cm, leading to residence times between 0.7 and 4.5 s at a 300 ml min -1 flow rate and between 1.5 and 9.0 s at a 150 ml min -1 flow rate. 65 66 FigureS1. Schematic diagram of the flow tube reactor. 6

67 68 69 70 71 72 To examine whether there is adsorption of SO 2 onto the Pyrex surface, a blank experiment was conducted with about 4.6 10 12 molecules cm -3 (corresponding to 184 ppb) SO 2 introduced into a clean tube (washed with a NaOH solution, acetone and ultrapure water sequentially). The injector was successively withdrawn for 3.3, 9.9 and 19.8 cm length. No decrease of SO 2 was observed (Figure S2), indicating that there is no adsorption of SO 2 on the Pyrex tube. 6 5 SO 2 concentration / 10 12 cm -3 4 3 2 1 expose 3.3 cm expose 9.9 cm expose 19.8 cm 73 0 0 5 10 15 20 25 30 35 40 45 Time / min 74 75 76 77 Figure S2. Temporal evolution of SO 2 concentration. The injector was successively withdrawn for 3.3, 9.9, 19.8 cm length over a blank Pyrex tube. Experimental conditions: SO 2 concentration = 4.6 10 12 molecules cm -3, flow rate = 150 ml min -1, RH = 6%. 78 79 80 81 82 83 All tubes used to prepare organic films were washed with a NaOH solution, acetone and ultrapure water sequentially. In a typical experiment, oleic acid was introduced into the tube adhered onto the inside of the tube. In order to coat the Pyrex tube, 40 mg ml -1 oleic acid solution in acetone (Sigma-Aldrich, CHROMOSOLV Plus, for HPLC, 99.9% purity) was prepared, introduced into the tube, then brushed 7

84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 using a Teflon rod, and finally dried in air. Because of the oily properties of OA, it was dispersed evenly as an oily thin film (sometimes showing little drops). Then the tube was exposed to SO 2 with a flow rate of 300 ml min -1 or 150 ml min -1.A steadystate flow of SO 2 was first established without exposure of the oleic acid film. When the SO 2 concentration was stable, the injector was quickly withdrawn to expose 3.3 cm of the coated tube with the oleic acid film to SO 2 gas. A sharp decrease in SO 2 concentration was observed upon exposure of SO 2 to oleic acid. No obvious recovery in the SO 2 concentration was observed during the exposure. After about 10 min, the injector was moved downstream, that is, no oleic acid was exposed to SO 2, and the SO 2 concentration returned to its original level. This withdrawing and return of the injector was repeated for 6.6, 9.9, 13.2, 16.5 and 19.8 cm respectively of the oleic acid surface exposed to SO 2 for 10 min each time (Figure S3). The SO 2 signal decay increased with the increase of oleic acid exposure length. After each 10 min exposure, the injector was pushed downstream to the original position, and a full recovery of the signal was observed every time. 99 100 101 102 103 Similarly to OA films, stearic acid and sodium oleate films were prepared as follows: A 6 mg ml -1 stearic acid or an 8 mg ml -1 sodium oleate ethanol solution was added into a Pyrex tube until a coating of 4.5 mg or 4.9 mg was reached for stearic acid and sodium oleate, corresponding to calculated film thickness of 0.73 or 0.79 µm respectively. 104 8

3.0 2.5 SO 2 concentration / 10 12 cm -3 2.0 1.5 1.0 0.5 3.3 cm 6.6 cm 9.9 cm 13.2 cm 16.5 cm 19.8 cm 105 106 107 108 109 110 0.0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Time / min Figure S3. Uptake of SO 2 on the surface of oleic acid. The injector was withdrawn for 3.3, 6.6, 9.9, 13.2, 16.5 and 19.8 cm, respectively, over the oleic acid surface and then returned to its original position. Experimental conditions: oleic acid mass = 7.0 mg, SO 2 concentration = 2.1 10 12 molecules cm -3, flow rate = 300 ml min -1, RH = 6%. 111 8 7 Uptake coefficient / 10-6 6 5 4 3 2 1 112 0 5 10 15 20 25 30 35 40 45 Oleic acid mass / mg 113 114 115 116 Figure S4. Dependence of uptake coefficient with oleic acid mass. Experimental Conditions: oleic acid mass = 5.7, 10.3, 17.4, 21.6, 23.7, 24.4, 28.0, 42.4 mg; RH = 3~4%, SO 2 initial concentration = 2.0~2.1 10 12 molecules cm -3 ; flow rate = 300 ml min -1. 9

7 6 23 min 180 min SO 2 concentration / 10 12 cm -3 5 4 3 2 1 stearic acid sodium oleate oleic acid 117 118 119 120 121 122 123 0 0 50 100 150 200 250 300 350 400 450 Time / min Figure S5. Uptake of SO 2 on stearic acid, sodium oleate and oleic acid films. Experimental Conditions: SO 2 initial concentration is 4.5 10 12 molecules cm -3 ; RH = 0.1%; T = 293 K; the mass of stearic acid, sodium oleate and oleic acid is 4.5, 4.9 and 3.0 mg, respectively; flow rate = 150 ml min -1 ;exposure length 19.8 cm. The time regions of zero signal of SO 2 (background signal) during 0-25, 150-180 min and 230-260 min are the switching period for the tube. 124 125 126 2. PRODUCT IDENTIFICATION 127 128 2.1 Analytical conditions for the condensed phase products by UHPLC- HRMS 129 130 131 132 All solvents were purchased from Fisher Scientific (USA) and were chemical grade Optima LC-MS. The chromatographic separation was performed by injecting 5 μl of samples into a C 18 Acquity UPLC HSS T3 column (1.8 µm, 2.1 mm 100 mm, Waters). The mobile phase was: (A) water with 0.1% formic acid and (B) acetonitrile 10

133 134 135 136 137 138 139 140 141 142 143 144 with 0.1% formic acid. Gradient elution was performed at a flow rate of 0.3 ml min -1, starting at 1% B (for 2 min) linearly programmed to 100% B within 11 min, this ratio was maintained constant for 2 min before returning to initial conditions (B at 1%) in 0.1 min for 6.9 min. The mass spectrometer was operated in full-scan mode with a scanning range from 50 to 750 m/z and a resolution of 140,000. Electrospray ionization was performed in negative mode using the following conditions: spray voltage -3.0 kv, capillary temperature 350 C, sheath gas (N 2 ) flow rate 40 (arbitrary units), auxiliary gas (N 2 ) flow rate 25 (arbitrary units), heater temperature 250 C, S- lens RF level 50. The Q-Exactive mass spectrometer was calibrated externally every day by direct infusion of a sodium acetate solution (2 mm in H 2 O/CH 3 CN 1/1 v/v) to reach mass accuracies below 2 ppm. The data were processed using Xcalibur v. 2.2 software. 145 146 2.2 Analytical conditions for the gas phase products by SRI-ToF-MS 147 148 149 150 151 152 The reagent ions to ionize products are generated by a hollow cathode discharge ion source using water vapor in the case of H 3 O + ionization mode and a mixture of N 2 and O 2 in the case of NO + ionization mode. The settings of the source were optimized for each ionization mode in order to obtain less than 2% impurities in the primary ion signal. In the H 3 O + mode the settings used were: source current 4 ma; source voltage 100 V; source outlet voltage 80 V ; and source valve opening at 37 % with a flow of 11

153 154 155 156 157 158 159 160 161 5.8 sccm of water vapor. In the NO + ionization mode, the source settings were the following: source current 5.5; source voltage 25 V; source outlet voltage 69 V and source opening valve at 36 % with flows of 5.4 sccm and 2.8 sccm for O 2 and N 2 respectively. For H 3 O + ionization mode spectra were acquired between 1 and 350 m/z at a sampling frequency of 25 khz and were registered by co-adding single TOFextractions for a time of 1 s. In NO + ionization mode spectra were acquired between 1 and 400 m/z at a sampling frequency of 35 khz and were registered by co-adding single TOF-extractions for a time of 8 s. Data were processed using PTR-MS Viewer 3.1.0.12. 162 12

163 3. REFERENCES 164 165 166 167 168 1. Keyser, L. F.; Moore, S. B.; Leu, M. T. Surface Reaction and Pore Diffusion in Flow-tube Reactors. J. Phys. Chem.1991, 95, 5496-5502. 2. Zhang, D.; Zhang, R. Y. Laboratory Investigation of Heterogeneous Interaction of Sulfuric Acid with Soot. Environ. Sci. Technol.2005, 39, 5722-5728. 13