Clinical Study Age and Positional Effect on the Anterior Chamber Angle: Assessment by Ultrasound Biomicroscopy

Similar documents
he Role of UBM and Anterior Segment OCT in Anterior Segment Imaging

3/16/2018. Ultrasound Biomicroscopy in Glaucoma By Ahmed Salah Abdel Rehim. Prof. of Ophthalmology Al-Azhar University

Corporate Medical Policy

Ultrasound Biomicroscopic Changes of the Angle after Laser Iridotomy and Primary Trabeculectomy in Primary Angle Closure Glaucoma Patients

Clinical Study Age-Related Changes in Trabecular Meshwork Imaging

UBM and glaucoma: diagnosis and follow-up of plateau iris. M. Puech

5/18/2014. Fundamentals of Gonioscopy Workshop Aaron McNulty, OD, FAAO Walt Whitley, OD, MBA, FAAO

Ultrasound Biomicroscopy & Glaucoma Care

Routine OCT and UBM of the anterior segment

Angle Recess Area Decreases With Age in Normal Japanese

Management of Angle Closure Glaucoma Hospital Authority Convention 18 May 2015

Ultrasound Biomicroscopy Dark Room Provocative Testing: A Quantitative Method for Estimating Anterior Chamber Angle Width

Understanding Angle Closure

Are traditional assessments a waste of time? NZAO 2015

Ultrasound Biomicroscopy Noel Moniz, MS L.F. Hospital and Reserach Centre, Angamaly

Increased iris thickness and association with primary angle closure glaucoma

Systems for Anterior Chamber Angle Evaluation 長庚紀念醫院青光眼科吳秀琛

STUDY OF EFFECTIVENESS OF LENS EXTRACTION AND PCIOL IMPLANTATION IN PRIMARY ANGLE CLOSURE GLAUCOMA Sudhakar Rao P 1, K. Revathy 2, T.

Gonioscopy is currently regarded as the reference standard

_ Assessment of the anterior chamber. Review of anatomy of the angle

CLINICAL STUDY. K Mansouri, J Sommerhalder and T Shaarawy

Chronicity. Narrow Minded. Course Outline. Acute angle closure. Subacute angle closure. Classification of Angle Closure 5/19/2014

Populations Interventions Comparators Outcomes Individuals: Who are being evaluated for angleclosure

Citation BMC Ophthalmology, 2016, v. 16, article no. 64

Anterior segment imaging in angle-closure disease

INTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany

Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy

Structural changes of the anterior chamber following cataract surgery during infancy

03/04/2015. LOC Talk Anterior Chamber & Gonioscopy 1st April Methods of Assessing Anterior Chamber Depth (and angle width) Outline

Ciliary body enlargement and cyst formation in uveitis

Research Article Evaluation of Anterior Chamber Volume in Cataract Patients with Swept-Source Optical Coherence Tomography

Ultrasound Biomicroscopy Study of Anterior Segment Measurements in Normal Eyes in a Tertiary Care Rural Hospital of SPRR Nellore District

Clinical and Anterior Segment Anatomical Features in Primary Angle Closure Subgroups Based on Configurations of Iris Root Insertion

Clinical Study Application of Anterior Segment Optical Coherence Tomography in Pediatric Ophthalmology

Primary Angle Closure Glaucoma

Entropion uveae: Early sphincter atrophy, signposting primary angle closure glaucoma?

Gonioscopy and Slit Lamp Exam for the Glaucoma Suspect. Disclosure GONIOSCOPY: Gonioscopy Why?? What should I look for? GONIOSCOPY

Primary angle closure (PAC) Pathogenesis: Pathogenesis 12/2/2016. Ying Han, MD, PhD Associate Professor of Ophthalmology Glaucoma Service, UCSF

Anterior segment imaging

Downloaded from:

Anterior Segment Optical Coherence Tomography Changes to the Anterior Chamber Angle in the Short-term following Laser Peripheral Iridoplasty

Glaucoma: Diagnostic Modalities

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure

The evaluation of retinal nerve fiber layer in pigment dispersion syndrome and pigmentary glaucoma using scanning laser polarimetry

Pretreatment Anterior Segment Imaging During Acute Primary Angle Closure

Medium-term Anatomical Results of Laser Peripheral Iridoplasty: An Anterior Segment Optical Coherence Tomography Study

Ultrasound Evaluation of the Posterior Segment of the Eye A Ready Reckoner

Pseudophakic angle-closure from a Soemmering ring

Role of Ultrasound Biomicroscopy in the Management of Retinoblastoma

Goals. Glaucoma PARA PEARL TO DO. Vision Loss with Glaucoma

Case Study. Monocular Malignant Melanoma

Anterior Segment Optical Coherence Tomography for the Quantitative Evaluation of the Anterior Segment Following Boston Keratoprosthesis

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Description. Section: Other Effective Date: July 15, 2015 Subsection: Vision Original Policy Date: June 7, 2012 Subject: Page: 1 of 11

Wallace L.M. Alward, M.D. Frederick C. Blodi Chair Department of Ophthalmology

Fundamentals of Gonioscopy

ORIGINAL ARTICLE. Darkroom Prone Provocative Test in Primary Angle Closure Glaucoma Relatives

The Effect of Pupil Dilation on Scanning Laser Polarimetry With Variable Corneal Compensation

Closed Angle Glaucoma Or Narrow Angle Glaucoma. What s is a closed angle type of glaucoma,

Outline. Brief history and principles of ophthalmic ultrasound. Types of ocular ultrasound. Examination techniques. Types of Ultrasound

GLAUCOMA SUMMARY BENCHMARKS FOR PREFERRED PRACTICE PATTERN GUIDELINES

Optical Coherence Tomography (OCT) of the Anterior Eye Segment

Overview of Ultrasound Biomicroscopy

Nate Lighthizer, O.D., F.A.A.O. Assistant Professor, NSUOCO Assistant Dean, Clinical Care Services Director of CE Chief of Specialty Care Clinics

Introduction. We are finally using a laser!!! The Use of a Femtosecond Laser for Complex Cataract Procedures. Financial Disclosure

Medical Policy. MP Optical Coherence Tomography of the Anterior Eye Segment

Primary angle closure glaucoma (PACG) is one of the leading

9/25/2017 CASE. 67 years old On 2 topical meds since 3 years. Rx: +3.0 RE LE

Author s Affiliation. Original Article. Comparison of Biometry in Phakic and Dense Modes. Muhammad Suhail Sarwar. Unaiza Mariam

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

Morphological Study of Corneal Endothelium and Corneal Thickness in Pseudoexfoliation Syndrome

INFANTILE NEPHROPATHIC cystinosis

Primary angle-closure glaucoma (PACG) is a major cause

Role of Ultrasound Biomicroscopy (UBM) in the Detection and Localisation of Anterior Segment Foreign Bodies *

Gonioscopy and 3-Mirror Retinal Evaluation Workshop Edeline Lu, O.D., FAAO Benedicte Gonzalez, O.D., MPH, FAAO Tina Zheng, O.D.

Immersion Vs Contact Biometery for Axial Length Measurement before Phacoemulsification

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

The effect of cataract extraction on intraocular pressure

4/2/2016. Bond, Brent "We Should Be Doing More. Hpw?" We Should Be Doing More Gonioscopy and Iridoplasty: GONIOSCOPY GONIOSCOPY

Part II. Basic Principles

Romanian Journal of Ophthalmology, Volume 59, Issue 4, October-December pp:

Quantitative Evaluation of Gonioscopic and EyeCam Assessments of Angle Dimensions Using Anterior Segment Optical Coherence Tomography

Dr. Harvey Richman, OD, FAAO, FCOVD Diplomate American Board of Optometry Executive Committee AOA Third Party Center Founder Ask the AOA Coding

SOCT Copernicus REVO. * - Currently import and overlay are avaibale in manual mode only

Technicians & Nurses Program

THE CHRONIC GLAUCOMAS

A Guide to Administering

1/31/2018. Course Objectives. Diagnostic Testing. Optic Nerve Damage ANATOMY AND PHYSIOLOGY OF A GLAUCOMA WORK-UP/TONOMETRY TECHNICIAN: -SDP

Collaboration in the care of glaucoma patients and glaucoma suspects. Barry Emara MD FRCS(C) Nico Ristorante November 29, 2012

The second most common causes of blindness worldwide. ( after cataract) The commonest cause of irreversible blindness in the world Estimated that 3%

1/25/2019 OCT & OCTA RETINAL IMAGING: HOW TO PREVENT RAGING GLAUCOMA! THE ORIGINAL RAGING GLAUCOMA OCT RETINAL IMAGING OPTIC NERVE HEAD EXAMINATION

THE CHRONIC GLAUCOMAS

Role of Lens Extraction in Primary Angle Closure Disease

Over the past decade, new anterior chamber (AC) imaging

CASE PRESENTATION. DR.Sravani 1 st yr PG Dept of Ophthalmology

OPHTHALMOLOGY AND ULTRASOUND

Clinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic Syndrome

SUPPLEMENTARY INFORMATION

Anterior Chamber Angle: Assessment and Anomalies

Transcription:

Hindawi Publishing Corporation ISRN Ophthalmology Volume 2013, Article ID 706201, 5 pages http://dx.doi.org/10.1155/2013/706201 Clinical Study Age and Positional Effect on the Anterior Chamber Angle: Assessment by Ultrasound Biomicroscopy Nicholas P. Bell, 1,2 Kundandeep S. Nagi, 1,3 Ricardo J. Cumba, 1,4 Alice Z. Chuang, 1 David A. Lee, 1,2 Thomas C. Prager, 1,5 Kavita Rao, 1 and Robert M. Feldman 1,2 1 Ruiz Department of Ophthalmology and Visual Science, The University of Texas Medical School at Houston, 6431 Fannin Street, MSB 7.024, Houston, TX 77030, USA 2 RobertCizikEyeClinic,6400FanninStreet,Suite1800,Houston,TX77030,USA 3 Department of Ophthalmology, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Drive, Mail Code 6230, San Antonio, TX 78229, USA 4 Ophthalmology Department, University of Puerto Rico, Medical Sciences Campus, P.O. Box 365067, San Juan, PR 00936, USA 5 Houston Eye Associates, 2855 Gramercy Street, Houston, TX 77025, USA Correspondence should be addressed to Nicholas P. Bell; nbell@cizikeye.org Received 8 March 2013; Accepted 1 April 2013 Academic Editors: U. U. Inan, T. Mimura, and M. Nakazawa Copyright 2013 Nicholas P. Bell et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Purpose. To investigate age- and position-related changes of anterior chamber angle anatomy in normal, healthy eyes. Patients and Methods. Thirty subjects were separated into a younger and older cohort. The superior and inferior anterior chamber angles of the eyes were measured in supine and sitting positions by ultrasound biomicroscopy (UBM) with bag/balloon technology. Statistical analysis was used to evaluate positional and age-related changes in angle morphology. Results. In the younger cohort, no location or positional differences in angle anatomy were observed. In the older cohort, the inferior quadrant was significantly narrower than the superior quadrant (P = 0.0186) in the supine position. This cohort also demonstrated an interaction effect between position and location. In the older cohort, the angle was deeper inferiorly while the subject was sitting but was deeper superiorly while the subject was supine.conclusion. Comparison of positional variations in anterior chamber angle anatomy as measured by UBM has recently become possible. This study found that age-related positional changes in the anterior chamber angle anatomy exist in normal healthy eyes. 1. Introduction Ultrasound biomicroscopy (UBM) provides noninvasive high-resolution in vivo imaging of the anterior segment. While anterior tissues are readily visualized by conventional methods (e.g., slit-lamp biomicroscopy and gonioscopy), structures posterior to the iris are hidden due to absorption of light by the iris pigment epithelium. Such structures may also be undetected by anterior segment optical coherence tomography (ASOCT), given the inability of light to penetrate the iris pigment epithelium. B-scan ultrasonography, though extremely useful in imaging posterior ocular structures, is also not ideal for ciliary body imaging due to the nearfield artifact and poorer resolution obtained with lower frequencies. However, the higher frequency ultrasound waves, utilized by UBM, are not obstructed by pigmented tissue andgivetherequiredresolution.thus,ubmcanbeusedto image not only the anterior chamber angle but also the ciliary body, peripheral lens, zonules, and the posterior chamber of the eye [1]. UBM has been demonstrated to be useful in evaluating the anterior segment of eyes with the primary angle closure spectrum of disorders [2]. It also may be used to elucidate the mechanism of malignant glaucoma, pigmentary glaucoma, and anterior scleral disease [3 5]. Therefore,UBMhasbecomethecurrentstandardforimaging abnormalities of ciliary body position, as are found in plateau iris configuration and annular choroidal effusions. UBM technology is now readily available and simple to use with the development of a water-filled bag (ClearScan

2 ISRN Ophthalmology Cover, ESI, Inc., Plymouth, MN), replacing traditional openshell immersion techniques. The single-use, sterile bag snugly fits over the distal end of the probe to form a watertight seal, which when pushed against the eye creates balloon-like positive pressure [6]. The tip of the UBM probe does not contact ocular structures, thus overcoming near-field artifact as well as increasing patient comfort. A distinct advantage of this technique is the ability to perform UBM examinations with the subject in any position [6]. Historically, as used clinically, UBM examinations have only been possible in the supine position due to the requirement of an open-shell immersion technique to overcome the acoustic near-field artifact inherent to ultrasonic imaging. There have been scattered reports in the literature of positional measurements using UBM [7 10]. However, the effects of age and supine to sitting positional change on anterior chamber anatomy in normal subjects are not known. Changes in laxity of the irido-lenticular-zonular (ILZ) apparatus with age theoretically may lead to alterations of the anterior chamber angle configuration that may be identified and measured with UBM. This study is designed to investigate age- and position-related changes of anterior chamber angle anatomy in normal, healthy eyes. 2. Patients and Methods This research was approved by the Committee for the Protection for Human Subjects at The University of Texas Health ScienceCenteratHouston.Theprotocolandprocedures adheredtothetenetsofthedeclarationofhelsinki,andthe study was HIPAA compliant. 2.1. Study Population. Subjects were initially considered for participation if they were between 18 and 30 years of age (younger cohort) or older than 45 years of age (older cohort) and could tolerate both the supine and sitting positions for at least 15 minutes. Informed consent was obtained, and a screening history and examination were performed consisting of slit-lamp biomicroscopy, applanation tonometry, and gonioscopy. Subjects were considered eligible if the following criteria were met: open angles (Schaffer grade 3-4), intraocular pressure (IOP) 8 21 mm Hg, and no ocular history other than refractive error. If both eyes were eligible, the right eye of each participant was selected as the study eye. 2.2. UBM Imaging. The superior and inferior anterior chamberangleswereimagedatthelimbususingthevumaxii UBM (Sonomed, Lake Success, NY) in high resolution mode with a 35 MHz probe tipped with a ClearScan Cover under topical anesthesia as previously described [6]. Of note, the techniquewasmodifiedbyfillingthebagtotheloweraspect of the sealing collar instead of to the top end. Thus, the baghadalowerinternalpositivepressurethantheeyeto minimize compression of the ocular structures. With the probe s orientation line facing the cornea, the UBM probe was held perpendicular to the segment of angle being measured. Images of the anterior chamber angle at superior and inferior quadrants were taken in sitting and supine positions 0.5 mm Figure 1: The anterior chamber angle (ACA) is the angular measurement (in degrees) created by two 500 micron line segments originating at the iris root, extending along the posterior cornea and anterior iris surface. in a dark room in a randomized fashion. Three sets of images were taken of each participant under each testing condition. 2.3. Measurement. The primary outcome measure was the anterior chamber angle (ACA, in degrees) formed from the angle created by two 500 micron line segments originating at the iris root, extending along the posterior cornea and anterior iris surface (see Figure 1). Three images were obtained for each quadrant (superior and inferior) in each position (sitting and supine), with the largest angle measurement (for consistency) recorded in each test condition. To validate the use of the largest angle measurement, a post hoc analysis using the mean of the 3 measurements was performed. 2.4. Sample Size Calculation and Statistical Analysis Methods. A sample size of 14 subjects per group was determined to be sufficient to detect a mean difference of 5 degrees between age groups for each condition at a 5% significance level and 80% power assuming that the angle was normally distributed with standard deviation of 4.5 degrees. Hence, 15 subjects were recruited per group to allow for potential loss during testing. Descriptive statistics, mean and standard deviation, were calculated for each condition by age group. The Kolmogorov- Smirnov test was performed to validate that the ACAs were normally distributed. A mixed-effect model was used to compare the overall ACA between age groups and the interaction effect of location and position within each cohort. The paired t-test was used to compare the effect of condition changes (position: seated versus supine; location: superior versus inferior) on ACA within participants for each age group. The mean difference in ACA between younger and older age groups for each condition (i.e., position, and angle location) was computed, and a two-sample t-test was used to determine significant changes. The analyses were performed using SAS v9.2 (SAS Institute Inc., Cary, NC). P values < 0.05 were considered statistically significant.

ISRN Ophthalmology 3 Table 1: Comparing positions at each location in each cohort. Superior (a) Superior Inferior Sitting Supine Sit Supine Younger Superior 41.3 ± 5.7 41.5 ± 4.4 0.2 ± 5.7 Inferior 40.6 ± 6.6 40.5 ± 3.3 0.1 ± 7.1 Superior Inferior 0.7 ± 7.0 1.0 ± 4.7 Older Superior 36.8 ± 4.5 38.3± 5.2 1.5± 3.6 Inferior 38.1 ± 4.4 36.2 ± 5.4 1.9± 3.6 Superior Inferior 1.3 ± 3.4 Narrower by 2.1 ± 3.0 ComparingmeanACAbetweenagecohortsusingtwosamplet-test. Comparing mean ACA between superior and inferior quadrants using paired t-test. Comparing mean ACA between seated and supine positions using paired t-test. Statistically significantly different between age cohorts. Statistically significantly different between superior and inferior quadrants within older cohort. (b) Inferior Figure 2: Tilting of the lens in the supine (a) and sitting (b) positions during ultrasound biomicroscopy imaging in the older and younger cohorts. Dashed line = older cohort. Solid line = younger cohort. 3. Results A total of 30 participants were enrolled in the study, with 15 in each age cohort. All enrolled participants completed thestudy.themeanageintheoldercohortwas57.4 ± 6.7 (range: 45 70) years and in the younger cohort was 25.7 ± 0.7 (range: 24 27) years. There were 10 (67%) males in the older cohortand9(60%)malesintheyoungercohort.twelve participants (80%) were white, two Asian, and one black in theoldercohortwhile10participants(66%)werewhite,four Asian, and one black in the younger cohort. The Kolmogorov- Smirnov test showed that ACAs were normally distributed (P = 0.1500). Overall, the mean ACA was 37.4 ± 4.8 degrees for the older cohort and 41.0 ± 5.0 degrees for younger cohort. This difference of 3.6 degrees was statistically significant (N = 15 4 = 60 angles; P = 0.0136 using a mixed-effect model). In the sitting/superior and inferior/supine conditions, there was a statistically significant difference between age groups, with the younger group having larger angles. 3.1. Location (Superior versus Inferior Angle). Except for the supine position in the older cohort, where the inferior quadrant was significantly narrower than the superior quadrant (P = 0.0186), there were no statistically significant differences (Table 1)inACA. 3.2. Position (Sitting versus Supine). There were no statistically significant changes in the ACA regardless of the angle location or age cohort. However, there was a trend for deepening of the superior angle (P = 0.1322)andnarrowing of the inferior angle (P = 0.0583) uponchangingfromthe supine to the sitting position in the older cohort. 3.3. Position (Sitting versus Supine) and Location (Superior versus Inferior) Combined Effect. In the younger cohort there was no interaction between location and position; however, an interaction effect was observed in the older group. This observation was verified by a mixed-effect model with location, position, and their interaction as the fixed effects for each cohort. The interaction between position and location was not significant for the younger cohort (P = 0.9002) but was significant in older cohort (P = 0.0130). In older cohort, the angle was deeper inferiorly while the participant was sitting but was deeper superiorly while the subject was supine. 4. Discussion Thedevelopmentofthewater-filledprobecoverhasincreased the comfort and versatility of UBM examination of the ACA. While previous studies have examined the structural changes in the ACA [7 11], this is the first study to address whether positional changes in angle measurements vary with age. In this study, the ACA of the older cohort was overall 4.5 degrees narrower than that of the younger cohort (mean ACA of 37.4 ± 4.8 degrees in the older cohort versus 41.0 ± 5.0 degrees in the younger cohort; P = 0.0136). This supports the well-documented literature regarding narrowing of the anterior chamber angle with age [11 14], the cause of which may be from continuous growth and increased thickness of the crystalline lens throughout life [15].

4 ISRN Ophthalmology There is debate regarding which quadrant is the narrowest.esakietal.reportedwithubm,inagreementwith clinically accepted gonioscopic findings, that the superior angle is the narrowest while the inferior is the deepest [12]. However, Friedman et al. suggest inconsistency between sitting gonioscopic and supine UBM findings, reporting that the inferior angle is the narrowest when measured by UBM in the supine position [11]. In the current study, for the younger cohort, there was no difference between the superior and inferior angle width regardless of position. In the older cohort, the inferior angle was narrower than the superior angle in the supine position (inferior angle narrower by 2.1 ± 3.0 degrees; P = 0.0186), in contrast to the sitting position, where no significant difference was found between the superior and inferior angle widths. Position has been hypothesized to affect ACA width. Ishikawa et al. suggested that supine positioning would allow the lens to fall backwards, deepening the angle [16]. In addition, Friedman et al. reported that supine UBM and sitting gonioscopy are poorly correlated and theorized that increased gravitational forces on the lens in the sitting position result in a deeper inferior ACA [11]. Until the current study, conclusions comparing UBM to gonioscopy were difficult because they were not generally performed in thesameposition.inthisstudy,nosignificantdifferencein the marginal ACA with positional change was noted in either cohort. However, there was an interaction observed in the older cohort: the magnitude of deepening in the superior angle when moving from the sitting to supine position was matched by the magnitude of narrowing of the inferior angle with the same positional change. This phenomenon may be consistent with Friedman s theory [11] andmaysuggest positional tilting of the lens (Figure 2). In the current study, there was a positional change in angle measurements in the older cohort, which was not found in the younger cohort. One potential explanation for this agerelated difference is that the irido-lenticular-zonular (ILZ) apparatusmaydeveloplaxitywithagewithresultanttilting of lens position as described earlier and detailed in Figure 2. This study has several limitations. Due to limitations of 35 mhz UBM image resolution, accurate identification of the scleral spur was not possible. Commonly used angle measurements, angle opening depth (AOD) and angle recess area (ARA), require a reproducible scleral spur; therefore, the iris root was used as the apex of the angle. This should not affect our results since this study did not include eyes with closed angles. Additionally, previous reports evaluating anterior chamber anatomy with UBM have suggested that the placement of a cup to hold liquid over the eye may indent the sclera and alter angle anatomy [17]. Using the bag/balloon technology, there is no hard shell or cup to artifactually indent the sclera/cornea. It is important to note that the internal bag pressure must be lower than the IOP of the patient s eye to avoid denting the cornea. Bag pressure can be changed by adjusting the amount of water in the bag and the probe insertion depth. One other potential weakness is the use of the largest of 3 repeated angle measurements as data. To evaluate this, a post hoc analysis using means of the 3 angle measurements was performed and resulted in identical conclusions. Angle anatomy changes with position in older participants, while it remains consistent in younger participants. This age-related difference may help explain inconsistencies in the literature on relative angle widths within an eye. Understanding normal angle anatomic changes may assist us in understanding the pathophysiologic events in diseases related to anterior chamber angle anatomy. Acknowledgments This work was supported in part by National Institutes of Health National Eye Institute Vision Core Grant P30EY010608, a Challenge Grant to The University of Texas Medical School at Houston from Research to Prevent Blindness, and the Hermann Eye Fund. We would like to thank Dr. Steven Wang for technical assistance with the figures and Dr. Kimberly Mankiewicz for editorial assistance. Dr. Prager is a coinventor and patent holder of the ClearScan Cover and a consultant for ESI, Inc., maker of the ClearScan Cover. No other authors declare conflict of interest. References [1] H. Ishikawa and J. S. Schuman, Anterior segment imaging: ultrasound biomicroscopy, Ophthalmology Clinics of North America,vol.17,no.1,pp.7 20,2004. [2]R.Sihota,T.Dada,R.Gupta,P.Lakshminarayan,andR.M. Pandey, Ultrasound biomicroscopy in the subtypes of primary angle closure glaucoma, Journal of Glaucoma,vol.14,no.5,pp. 387 391, 2005. [3]C.J.Pavlin,M.Easterbrook,J.J.Hurwitz,K.Harasiewicz, P. Eng, and F. S. Foster, Ultrasound biomicroscopy in the assessment of anterior scleral disease, American Journal of Ophthalmology,vol.116,no.5,pp.628 635,1993. [4] C. J. Pavlin, P. Macken, G. Trope, F. Feldman, K. Harasiewicz, and F. S. Foster, Ultrasound biomicroscopic features of pigmentary glaucoma, Canadian Journal of Ophthalmology, vol. 29,no.4,pp.187 192,1994. [5] G.E.Trope,C.J.Pavlin,A.Bau,C.R.Baumal,andF.S.Foster, Malignant glaucoma: clinical and ultrasound biomicroscopic features, Ophthalmology, vol. 101, no. 6, pp. 1030 1035, 1994. [6]N.P.Bell,R.M.Feldman,Y.Zou,andT.C.Prager, New technology for examining the anterior segment by ultrasonic biomicroscopy, Journal of Cataract and Refractive Surgery,vol. 34,no.1,pp.121 125,2008. [7] K. Esaki, H. Ishikawa, J. M. Liebmann, and R. Ritch, A technique for performing ultrasound biomicroscopy in the sitting and prone positions, Ophthalmic Surgery and Lasers, vol. 31,no.2,pp.166 169,2000. [8] K.Esaki,K.Ito,K.Matsunaga,K.Sugimoto,M.Sasoh,andY. Uji, Anterior chamber structural change in postural variation in pseudoexfoliation syndrome, Journal of Japanese Ophthalmological Society,vol.105,no.8,pp.524 529,2001. [9] R. Sano, T. Kurokawa, Y. Kurimoto, D. Miyazawa, and N. Yoshimura, Comparison between the anterior chamber configuration in the supine position and that in the prone position in patients with narrow angle, Nippon Ganka Gakkai Zasshi, vol. 105, no. 6, pp. 388 393, 2001.

ISRN Ophthalmology 5 [10] H. V. Tran, H. Ishikawa, J. M. Liebmann, and R. Ritch, A new silicone eyecup for ultrasound biomicroscopy, Ophthalmic Surgery and Lasers,vol.34,no.1,pp.73 75,2003. [11] D. S. Friedman, G. Gazzard, C. B. Min et al., Age and sex variation in angle findings among normal Chinese subjects: a comparison of UBM, Scheimpflug, and gonioscopic assessment of the anterior chamber angle, JournalofGlaucoma,vol.17,no. 1, pp. 5 10, 2008. [12] K. Esaki, H. Ishikawa, J. M. Liebmann, D. S. Greenfield, Y. Uji, and R. Ritch, Angle recess area decreases with age in normal Japanese, Japanese Journal of Ophthalmology,vol.44,no.1,pp. 46 51, 2000. [13] Z. Pan, T. Furuya, and K. Kashiwagi, Longitudinal changes in anterior chamber configuration in eyes with open-angle glaucoma and associated factors, Journal of Glaucoma, vol.21, no. 5, pp. 296 301, 2012. [14]L.Xu,W.F.Cao,Y.X.Wang,C.X.Chen,andJ.B.Jonas, Anterior chamber depth and chamber angle and their associations with ocular and general parameters: the Beijing Eye Study, American Journal of Ophthalmology,vol.145,no.5,pp.929 936, 2008. [15] Y.Chen,Y.Z.Bao,andX.T.Pei, Morphologicchangesinthe anterior chamber in patients with cortical or nuclear age-related cataract, Journal of Cataract and Refractive Surgery,vol.37,no. 1, pp. 77 82, 2011. [16] H. Ishikawa, K. Esaki, J. M. Liebmann, Y. Uji, and R. Ritch, Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width, Japanese Journal of Ophthalmology, vol.43,no.6,pp. 526 534, 1999. [17] H.Ishikawa,K.Inazumi,J.M.Liebmann,andR.Ritch, Inadvertent corneal indentation can cause artifactitious widening of the iridocorneal angle on ultrasound biomicroscopy, Ophthalmic Surgery and Lasers,vol.31,no.4,pp.342 345,2000.