Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods

Similar documents
Using Hemostatic Agents During Orthodontic Bonding: An In Vitro Study

Adhesive Thickness Effects on the Bond Strength of a Light- Cured Resin-Modified Glass Ionomer Cement

Bonding characteristics of a self-etching primer and precoated brackets: an in vitro study

Shear Bond Strength of Acidic Primer, Light-Cure Glass Ionomer, Light-Cure and Self Cure Composite Adhesive Systems - An In Vitro Study

A new flash-free orthodontic adhesive system: A first clinical and stereomicroscopic study

Immediate versus Delayed Force Application after Orthodontic Bonding; An In Vitro Study

A Comparative Study between Bond Strength of Rebonded and Recycled Orthodontic Brackets

Effect of Self-etchant ph on Shear Bond Strength of Orthodontic Brackets: An in vitro Study

Original Research. Shear bond strength of new self etching primer (RSEP) Sorake A et al

The Effect of Different Bracket Base Cleaning Method on Shear Bond Strength of Rebonded Brackets

Comparison of Shear Bond Strength of Metal Brackets Bonded to Porcelain Surface using Different Surface Conditioning Methods: An in vitro Study

Scanning Electron Microscopy Evaluation of the Bonding Mechanism of a Self-etching Primer on Enamel

[Downloaded free from on Wednesday, September 28, 2016, IP: ]

The effectiveness of paint remover to resin adhesive residue on base mesh of metal bracket

Various whitening systems are currently being

Shear Bond Strength of Orthodontic Brackets Cured with Different Light Sources under Thermocycling

The procedure for bonding orthodontic brackets

Three-dimensional measurement of enamel loss caused by bonding and debonding of orthodontic brackets. VAN WAES, H, MATTER, T, KREJCI, Ivo.

Evaluation of bond strength of orthodontic brackets without enamel etching

S. Shear bond strength and debonding characteristics of metal and ceramic

Bond Strength of Amorphous Calcium Phosphate Containing Orthodontic Composite Used as a Lingual Retainer Adhesive

Shear bond strength of ceramic and metallic orthodontic brackets bonded with self-etching primer and conventional bonding adhesives

Microleakage under Metallic and Ceramic Brackets Bonded with Orthodontic Self-Etching Primer Systems

Early Shear Bond Strength of a One-step Self-adhesive on Orthodontic Brackets

Assessing the Performance of a Methyl Methacrylate-Based Resin Cement with Self-Etching Primer for Bonding Orthodontic Brackets

Flowable Composite for Orthodontic Bracket Bonding (in vitro study)


The acid-etch technique has been widely used in

Post Graduate Student, Dept. of Orthodontics, KD Dental College and Hospital, Mathura, UP 2

Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel

AN 8 MONTH CLINICAL TRIAL OF BOND FAILUES WITH FOUR DIFFERENT TYPES OF ORTHODONTIC ADHESIVES

ORIGINAL RESEARCH. Sandhya CA Shyam Lohakare, Pushpa Vinay Hazarey ABSTRACT

Effects of a Self-Etching Primer and 37% Phosphoric Acid Etching on Enamel: A Scanning Electron Microscopic Study

The Impact of Er,Cr:YSGG Laser Recycling on Shear Bond Strength (SBS) of Stainless Steel Orthodontic Brackets

COMPARISON OF SHEAR BOND STRENGTH OF NEW AND RECYCLED BRACKETS WITH DIFFERENT MESH DESIGNS

Postgraduate Student, Department of Orthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran

A Comparison of Bond Strength Between Directand Indirect-bonding Methods

Bond Strength of Direct and Indirect Bonded Brackets After Thermocycling

Article. Reference. Light-curing time reduction with a new high-power halogen lamp. STAUDT, Christine Bettina, et al.

Effect of light-curing units in shear bond strength of metallic brackets: an in vitro study

Influence of saliva contamination on the shear bond strength of adhesives on enamel

Orthodontic In Vivo Bond Strength: Comparison with In Vitro Results

An In-Vivo Comparison Of The Efficacy Between Direct And Indirect Bonding Methods

The words adhesionpromoters werefirstusedto

Effects of sealant and self-etching primer on enamel decalcification. Part II: An in-vivo study

The effect of different force magnitudes for placement of orthodontic brackets on shear bond strength, in three adhesive systems

The effect of orthodontic bracket pad shape on shear bond strength, an in vitro study on human enamel

Transbond IDB Pre-Mix Chemical Cure Adhesive Lunch and Learn

Bond Strength of Disinfected Metal and Ceramic Brackets:

Even though the acid-etching technique is useful

Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets

Objective: The aim of this study was to assess the impact of blood contamination on shear

The effect of herbal teas on the shear bond strength of orthodontic brackets

Comparison of Shear Bond Strength of Orthodontic Brackets Bonded to Enamel Prepared By Er:YAG Laser and Conventional

Effects of Two Soft Drinks on Shear Bond Strength and Adhesive Remnant Index of Orthodontic Metal Brackets

Until recently, the most popular light-curing unit. Effects of high-intensity curing lights on microleakage under orthodontic bands ORIGINAL ARTICLE

Evaluation and comparison of shear bond strength of new and rebonded orthodontic brackets having various mesh base designs: An in vitro study

Original Article. Giulio Alessandri Bonetti a Serena Incerti Parenti a Daniela Rita Ippolito a Maria Rosaria Gatto a Luigi Checchi b

Microleakage and shear bond strength of orthodontc brackets bonded to hypomineralized enamel following different surface preparations

Incognito Appliance System Bonding Protocols Step-by-Step Procedures

Bonding to molars the effect of etch time (an in vitro study)

The Effect of Argon Laser Irradiation on Demineralization Resistance of Human Enamel Adjacent to Orthodontic Brackets: An In Vitro Study

Bond strengths of different orthodontic adhesives after enamel conditioning with the same self-etching primer

Objective: The aim of this study was to evaluate the effects of tribochemical silica coating

The Effects of the Acid Etch and Direct Bonding Technique in Orthodontics on Enamel Surface Topography

Fluoride Release Rate from an Orthodontic Sealant and Its Clinical Implications

Dental Research Journal

Improving Tensile Bond Strength of Orthodontic Bracket by Applying Papain Gel as an Deproteinization Agent

Prophylaxis-based dental treatment: cavity prophylaxis using enamel-protective bracket attachment

COMPARISON OF FINISHING AND POLISHING SYSTEMS FOR RESIDUAL RESIN REMOVAL AFTER DEBONDING

A prospective clinical evaluation of mandibular lingual retainer survival

Effects of silanation time on shear bond strength between a gold alloy surface and metal bracket

Various composite resins are used in orthodontic

Within the past few years, ceramic brackets have

COMPARISON BETWEEN MOLAR BANDS, BONDABLE TUBES AND BONDABLE TUBES WITH FLOWABLE COMPOSITE

UvA-DARE (Digital Academic Repository) A better understanding of orthodontic bracket bonding Algera, T.J. Link to publication

Effects of conventional and self-etching adhesive systems on bond strength of orthodontic attachments bonded to erupted and unerupted teeth

The influence of different bracket base surfaces on tensile and shear bond strength

In Vitro Investigation of Indirect Bonding with a Hydrophilic Primer

BioCoat Featuring SmartCap Technology

The effects of argon laser curing of a resin adhesive on bracket retention and enamel decalcification: a prospective clinical trial

Shear bond strength of metallic and ceramic brackets using color change adhesives

Chemical and morphological analysis of the human dental enamel treated with argon laser during orthodontic bonding

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

Effects of selenium-containing sealant and adhesive system on the shear bond strength of orthodontic brackets

Influence of Various Surface Conditioning Methods on Bonding Orthodontic Brackets to Porcelain Surface

Comparative Evaluation of Laser Etching and Acid Etching: An in vitro Study

Interview questions and answers:

Research Article Evaluation of Self-Etching Adhesive and Er:YAG Laser Conditioning on the Shear Bond Strength of Orthodontic Brackets

PDF hosted at the Radboud Repository of the Radboud University Nijmegen

Bond strength assessment of metal brackets bonded to porcelain fused to metal surface using different surface conditioning method

Evaluation of Shear Bond Strength Orthodontic Bracket and Adhesive Remaining Materials on the Enamel Surface Using ARI (Adhesive Remnant Index)

Recycling stainless steel orthodontic brackets with Er:YAG laser An environmental scanning electron microscope and shear bond strength study

Acidic Soft Drinks Effects on the Shear Bond Strength of Orthodontic Brackets and a Scanning Electron Microscopy Evaluation of the Enamel

A comparison of shear bond strength and mean survival time between treated and untreated mesh backed stainless steel brackets, an in-vitro assessment.

Influence of topical fluoride application on mechanical properties of orthodontic bonding materials under ph cycling

Transbond PLUS Color Change Adhesive Lunch and Learn

Effects of different primers on indirect orthodontic bonding: Shear bond strength, color change, and enamel roughness

LED vs Halogen Light-Curing of Adhesive-Precoated Brackets

Transcription:

Original Article Assessment of the Confidence of the Adhesive Remnant Index Score With Different Methods A. Alper Öz; 1 * Sabahat Yazicioğlu; 2 Nursel Arici; 3 Berat Serdar Akdeniz; 4 Naci Murat; 5 and Selim Arıcı 6 ABSTRACT Objective: The purpose of this in vitro study was to investigate the reliability of the adhesive remnant index (ARI) score system with different assessment methods and to test the compatibility of the estimators. Materials and Methods: Sixty-eight human premolars were used in this study. The premolar brackets (SmartClip, 3M Unitek, Monrovia, CA, USA) were bonded with a light cure adhesive (Transbond XT, 3M Unitek). Brackets were debonded using a Lloyd LRX testing machine (Lloyd Instruments Plc., Fareham, Hampshire, UK). Special image analysis software with 320 magnification and naked-eye assessment methods were used to evaluate the adhesive remnant. Four different investigators scored the same samples according to a 4-point scale. The Kendall rank correlation coefficient was used to test the reliability of the estimator s scores. The Friedman test, followed by the Wilcoxon signed-ranks test, was used to investigate significant differences in the ARI scores between the different assessment methods Results: The Kendall rank correlation coefficients revealed no significant difference between the scores assigned by the investigators in this study. However, the ARI scores were significantly different when the special image analysis program was used (p, 0.05). Conclusion: The reliability of the ARI scores increased when quantitative measurement methods were used. (Turkish J Orthod 2013;26:149 153) KEY WORDS: Adhesive Remnant Index, Quantitative Measurement INTRODUCTION The amount of residual bonding resin on the surface of the tooth or the bracket base is an important factor for clinicians in selecting an orthodontic adhesive. Although differences in adhesive remnant scores reflect the bonding strength, adhesive systems that show less residual resin are preferable because they are easier and safer to clean up after debonding procedures. As resin tags penetrate the enamel surfaces, reaching depths up to 50 lm, 1 they may exert irreversible effects on the enamel surfaces after orthodontic appliances are removed. 2 Thus, an assessment system to evaluate the adhesive remnant could be helpful for investigators. Årtun and Bergland first introduced the adhesive remnant index (ARI), 3 and most studies of bonding in orthodontics use this index. 4 6 Many studies have changed or expanded the ARI system scores to provide more sensitive evaluation. Årtun and Bergland 3 separated the adhesive remnant criteria according to the following: 0 = the entire adhesive left on the bracket base, 1 = more than half of the adhesive left on the bracket base, 2 = less than half of the adhesive left on the bracket base, and 3 = no adhesive left on the bracket base. Other studies in the orthodontic literature have developed a 5- or 6-point scale. 7,8 1 Assistant Professor, Ondokuz Mayıs University, Faculty of 2 Assistant Professor, Ondokuz Mayıs University, Faculty of 3 Assistant Professor, Ondokuz Mayıs University, Faculty of 4 Private Practice, Ankara, Turkey 5 Assistant Professor, Ondokuz Mayıs University, Department of Statistics, Samsun, Turkey 6 Assistant Professor, Ondokuz Mayıs University, Faculty of *Corresponding author: A. Alper Öz, Assistant Professor, Ondokuz Mayıs University, Department of Orthodontics, Atakum, Samsun, Turkey. Tel: þ90 362-312-19-19 (3025) E-mail: alperoz@hotmail.com To cite this article: Öz AA,Yazicioğlu S, Arici N, Akdeniz BS, Murat N, Arıcı S. Assessment of the confidence of the adhesive remnant index score with different methods. Turkish J Orthod. 2013;4:149 153. (DOI: http://dx.doi.org/10.13076/ TJO-D-13-00003) Date Submitted: July 2013. Date Accepted: December 2013. Copyright 2014 by Turkish Orthodontic Society 149

150 Öz et al. Various qualitative and quantitative methods have been used to determine the ARI on enamel surfaces or bracket bases after bracket removal, such as scanning electron microscopy (SEM), visual inspection, photography, 3-dimensional profilometry, stereomicroscopy, and visual inspection with photography under magnification. 6,9 11 If remnants are not adequately detected, ARI scores could be inaccurate. Therefore, the aim of this in vitro study was to evaluate the reliability of the ARI with different assessment methods and to investigate potential individual differences between estimators. The null hypothesis was that the ARI score would show no difference between the different assessment systems and that there would be no difference between the estimators when the 4-point ARI scales were used. MATERIAL AND METHODS Sixty-eight noncarious human premolars, which were extracted for orthodontic purposes from 14- to 17-year-old patients undergoing orthodontic treatment, were used in this study. Enamel structure of the teeth was examined at 320 magnification, and teeth with surface irregularities or hypoplastic areas were excluded from the study. The extracted teeth were stored in distilled water, and the water was changed weekly to avoid bacterial accumulation. The teeth were mounted in casts, keeping the long axis of the tooth parallel to the bottom of the mold and the plastic molding cup filled with dental stone. Before the bracket bonding, all the teeth were cleaned with a flour of pumice slurry. The enamel surface was then rinsed with water and dried with compressed air. The premolar brackets (SmartClip 3M Unitek, Monrovia, CA, USA) were bonded with a light cure adhesive (Transbond XT, 3M Unitek) according to the manufacturer s instructions, and excessive adhesive was removed using a sharp scaler. Finally, the bracketed tooth was stored in distilled water at 378C for 24 hours before the debonding test. 12,13 The samples were tested with a Lloyd LRX testing machine (Lloyd Instruments Plc, Fareham, Hampshire, UK) with a cross-head speed of 1 mm/min. Scaled digital photographs of every bracket base were taken with a digital imaging system (Nikon Digital Sight DS-L1 Imaging system) connected to a stereo light microscope (Nikon SMZ 1500, Nikon, Tokyo, Japan). Photographs of the bases were taken from the same angle of view for each bracket, taking care to show the whole bracket base and the remaining adhesive in every image. Images were 1280 3 960 pixels with a color depth of 24 bits and were stored in joint photographic experts group (JPEG) file format. After all the samples were tested, the brackets were debonded, and the records were collected, the images were transferred to a computer, and the digital photographs were randomly numbered. The bracket base and residual adhesive surface area were then digitized, and the number of pixels was counted automatically. The stained adhesive was measured quantitatively on color macrophotographs using a special computerized image analysis system (Fig. 1). The bracket base area covered with the residual adhesive and the total bracket base area were measured on the same digital photograph, and the percentage of the adhesive was calculated. The image analysis software automatically calculated the percentage of adhesive remnant surface area on the bracket base, and the researchers scored the ARI scale according to these records. The ARI evaluation used the 4-point scale of Årtun and Bergland (Fig. 2). After the image analysis software was used, the numbers of the samples and photographs were changed to maintain the blind nature of the design and to prevent bias. The adhesive remnant on the bracket base was then scored with the naked eye in daylight and in the photographs taken at 320 magnification. The evaluation and scoring of the adhesive remnant were carried out by 4 researchers, and the scores were recorded. The Kendall rank correlation coefficient was used to test the reliability of the estimators scores in this study. The Friedman test, followed by the Wilcoxon signed-ranks test, was used to investigate significant differences in the ARI scores between the different assessment methods. Results The distributions of the ARI scores for the different assessment methods for each investigator are given in Table 1. The results of the Kendall rank correlation coefficients for the reliability of the estimators showed that their scores were compatible. The Kendall rank correlation coefficients were 0.736 for the naked eye, 0.829 for the 320 magnification, and 0.863 for the image analysis program. When the scores were evaluated according to the 4-point scale, the Friedman test showed that the ARI scores were significantly different among the assessment methods (Table 2). The evaluation of the adhesive remnant with the special image analysis program showed a statistically significant difference com-

ASSESSING THE ADHESIVE REMNANT INDEX SCORE 151 Figure 1. Measurement of percentage adhesive remnant area with digitized computerized image analysis system. pared with the naked eye evaluation (p0.05). On the other hand, there was no statistically significant difference between the image program and the 320 magnifications according to the three researchers in this study (S.A., S.Y., and A.O.). Discussion This in vitro bonding study was designed to investigate the reliability of the ARI with different assessment methods and to compare potential differences between the evaluators. Testing 24 hours after bonding is generally preferred, and 24 hours allows comparison with other in vitro bond strength studies. 12 Furthermore, polymerization is expected to be complete at the end of 24 hours. 13 Only a limited number of studies have addressed the reliability and reproducibility of ARI scores. 6,11 Montasser and Drummond 11 showed that there was significant difference between the ARI scores when the evaluation was done at different magnifications. In the Figure 2. Adhesive remnant indexevaluation used a 4-point scale in which 0 = the entire adhesive left on the bracket base, 1 = more than half of the adhesive left on the bracket base, 2 = less than half of the adhesive left on the bracket base, and 3 = no adhesive left on the bracket base.

152 Öz et al. Table 1. Frequency of adhesive remnant index scores according to the estimators S.A. N.A. S.Y. A.O. 0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3 Naked eye 1 25 36 6 0 31 35 2 0 31 35 2 4 26 33 5 203 magnification 0 30 36 2 1 30 34 3 6 32 24 6 1 34 30 3 Computer 0 33 32 3 4 21 28 15 3 35 28 2 1 34 30 3 present study, use of a special computerized image analysis system resulted in significantly different ARI scores compared with those of the conventional assessment with the naked eye without any magnification. However, only one investigator (S.A.) reported a significant difference between the evaluations with the 320 magnifications and the naked eye. The other investigators found similar results between the naked eye and the 320 magnification assessment methods, and there was no significant difference between these two groups. It should be noted that personal bias could result in different estimators reaching different conclusions regarding the same samples. Montasser and Drummond 11 used the same evaluator, but our study included 4 different evaluators and 3 different methods. Therefore, we cannot compare our results with those of Montasser and Drummond. All the estimators in this present investigation reported compatible results, and there was no significant difference between the ARI scores of the different estimators. Therefore, the null hypothesis was rejected When the naked-eye assessment was compared with the image program assessment, some samples with a score of 1 changed to a score of 2 or some with a score of 2 changed to a score of 1. The percentage of the adhesive remnant on these samples was about 50%. Because of the sensitivity of the naked eye, the estimators could not distinguish the ARI scores when the adhesive remnant was about 50%. All the estimators had normal vision. Therefore, the use of specialized software such as the image analysis program used in this study could be suitable for such samples. The naked-eye evaluation is the easiest assessment method for detecting remnant adhesive. Most studies of the bonding strength of adhesives have used different evaluation techniques, for example, quantitative methods, to obtain more accurate results. However, these methods consume more time. The ARI scores for the percentage of the remnant adhesive have been calculated by software programs with standardized photographs. 14 Some studies have also examined the bracket base surfaces with SEM 15,16 as SEM images offer great possibilities for enamel or bracket-base surface investigation by providing high-quality results. Light stereomicroscopy and photomicrography have also been used to analyze ARI scores. 17,18 A past study also used weight of the bracket to quantify the residual adhesive after debonding, and weight produced statistically similar results to those based on measurements of area. 16 Arıcı et al. also used the same special computerized image analysis system to measure percentage dental plaque area and found that it was reproducible. 19 CONCLUSIONS On the basis of this in vitro study, the following conclusions can be drawn: Evaluation of remnant adhesive with the ARI (4- point scale) score is a reliable method according to this study, and there were no statistical differences between estimators scores. Quantitative methods such as image analysis programs may be useful for assessing residual adhesive after debonding. Table 2. Comparisons of the 3 methods using Wilcoxon tests Significance S.A. N.A. S.Y. A.O. Naked eye, 203 magnification.007*.850.072.467 Naked eye, computer.020*.004*.008*.046* Computer, 203 magnification.317.040*.796.484

ASSESSING THE ADHESIVE REMNANT INDEX SCORE 153 REFERENCES 1. Hermsen RJ, Vrijhoef MM. Loss of enamel due to etching with phosphoric or maleic acid. Dent Mater. 1993;9:332 336. 2. Eminkahyagil N, Arman A, Çetinsxahin A, Karabulut E. Effect of resin-removal methods on enamel and shear bond strength of rebonded brackets. Angle Orthod. 2006;76: 314 321. 3. Årtun J, Bergland S. Clinical trials with crystal growth conditioning as an alternative to acid-etch enamel pretreatment. Am J Orthod Dentofacial Orthop. 1984;85:333 340. 4. Talbot TQ, Blankenau RJ, Zobitz ME, Weaver AL, Lohse CM, Rebellato J. Effect of argon laser irradiation on shear bond strength of orthodontic brackets: an in vitro study. Am J Orthod Dentofacial Orthop. 2000;118:274 279. 5. Bishara SE, Gordan VV, VonWald L, Jakobsen JR. Shear bond strength of composite, glass ionomer, and acidic primer adhesive systems. Am J Orthod Dentofacial Orthop. 1999;115:24 28. 6. Cehreli SB, Polat-Ozsoy O, Sar C, Cubukcu HE, Cehreli ZC. A comparative study of qualitative and quantitative methods for the assessment of adhesive remnant after bracket debonding. Eur J Orthod. 2012;34:188 192. 7. Bishara SE, Trulove TS. Comparisons of different debonding techniques for ceramic brackets: an in vitro study. Am J Orthod Dentofacial Orthop. 1990;98:145 153. 8. Keçik D, Çehreli SB, Sar C, Ünver B. Effect of acidulated phosphate fluoride and casein phosphopeptide amorphous calcium phosphate application on shear bond strength of orthodontic brackets. Angle Orthod. 2008;87: 145 153. 9. Kim SS, Park WK, Son WS, Ahn HS, Ro JH, Kim YD. Enamel surface evaluation after removal of orthodontic composite remnants by intraoral sandblasting: a 3-dimensional surface profilometry. Am J Orthod Dentofacial Orthop. 2007;132:71 76. 10. Buyukyilmaz T, Usumez S, Karaman AL. Effect of selfetching primer on bond strength are they reliable? Angle Orthod. 2003;73:64 70. 11. Montasser MA, Drummond JL. Reliability of the adhesive remnant index score system with different magnifications. Angle Orthod. 2009;79:773 776. 12. Aljubouri YD, Millett DT, Gilmour WH. Laboratory evaluation of a self-etching primer for orthodontic bonding. Eur J Orthod. 2003;25:411 415. 13. Rock WP, Abdullah MS. Shear bond strengths produced by composite and compomer light cured orthodontic adhesives. J Dent. 1997;25:243 249. 14. Osorio R, Toledano M, Garcia-Godoy F. Bracket bonding with 15- or 60-second etching and adhesive remaining on enamel after debonding. Angle Orthod. 1999;69:45 48. 15. Sorel O, El Alam R, Chagneau F, Cathelineau G. Comparison of bond strength between simple foil mesh and laser structured base retention brackets. Am J Orthod Dentofacial Orthop. 2002;122(3):260 266. 16. Davıd VA, Staley RN, Bıgelow HF, Jakobsen JR. Remnant amount and cleanup for 3 adhesives after debracketing. Am J Orthod Dentofacial Orthop. 2002;121:291 296. 17. Miksic M, Slaj M, Mestrovic S Stereomicroscope analysis of enamel surface after orthodontic bracket debonding. Coll Antropol. 2003;27:83 89. 18. Türköz Ç, Ulusoy Ç. Evaluation of different enamel conditioning techniques for orthodontic bonding. Korean J Orthod. 2012;42(1):32 38. 19. Arıcı S, Alkan A, Arıcı N. Comparison of different toothbrushing protocols in poor-toothbrushing orthodontic patients. Eur J Orthod, 2007;29:488 492.