The shape and size of femoral components in revision total hip arthroplasty among Chinese patients

Similar documents
EXTENDED TROCHANTERIC OSTEOTOMY SURGICAL TECHNIQUE FPO EXTENSIVELY COATED FIXATION

Extensively Porous-coated Stems for Femoral Revision: Reliable Choice for Stem Revision in Paprosky Femoral Type III Defects

Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

Optimum implant geometry

REVIEW ARTICLE The use of cemented and cementless femoral components in revision total hip arthroplasty: a review of the literature

Optimum implant geometry

REVISING THE DEFICIENT PROXIMAL FEMUR

AML Hip System. Design Rationale/ Surgical Technique

Bone Preservation Stem

Featuring. Technology. Product Rationale

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Femoral Revision Algorithm. A practical guide for the use of the CORAIL Hip System in femoral revision surgery

Axial alignment of the lower extremity in Chinese adults. Journal Of Bone And Joint Surgery - Series A, 2000, v. 82 n. 11, p.

Revision Total Hip Arthroplasty

Revision hip arthroplasty with S-ROM prosthesis: a study of clinical outcomes and implant stability

Segmental Fracture Of A Cemented Femoral Stem - A Case Report And Review Of Litrature

Impact of Intramedullary Reaming Depth on Establishing Femoral Canal Axis in the Sagittal Plane

Shunsaku Nishihara 1, Nobuhiko Sugano 1, Takashi Nishii 1, Hisashi Tanaka 2, Hideki Yoshikawa 1, and Takahiro Ochi 1

operative technique Kent Hip

ACTIS. TOTAL HIP SYSTEM Approach Active Patients with Confidence DESIGN RATIONALE

Optimizing function Maximizing survivorship Accelerating recovery

Templating and Pre Operative Planning 2. Preparation of the Acetabulum 4. Trial Sizing and Impaction of the Shell 5.

Preoperative Planning. The primary objectives of preoperative planning are to:

Optimum implant geometry

Surgical Technique. Hip System

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

Approach Patients with CONFIDENCE

Bone Bangalore

HIP SYSTEM SURGICAL TECHNIQUE

This publication is not intended for distribution in the USA.

Specifications guide ECHELON. Hip System

Predicting the Position of the Femoral Head Center

Clinical Evaluation Surgical Technique

LPS SYSTEM POCKET GUIDE

THE NATURAL FIT. Surgical Technique. Hip Knee Spine Navigation

Cementless femoral stem type SF

Design Rationale. ECHELON Primary Hip System

Approach Patients with Confidence

Approach Patients with Confidence

THE P.F.C. SIGMA FEMORAL ADAPTER. Surgical Technique

Medium- to Long-term Results of Strut Allografts Treating Periprosthetic Bone Defects

This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

28 Surgical Technique

VerSys 6 Beaded FullCoat Plus Hip Prosthesis

Treatment of Periprosthetic Femoral Fractures Following Hip Arthroplasty

R/F. Can T-smart Tomosynthesis Improve Diagnostic Accuracy on THA Component Stability? 1. Abstract

Anterior Approach Surgical Technique. Paragon Stem System. enabling people to enjoy life

Metha Short Hip Stem System

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

MINIMUM TEN-YEAR FOLLOW-UP OF COMPUTED TOMOGRAPHY BASED, CUSTOM CEMENTLESS STEM AFTER INTERTROCHANTERIC OSTEOTOMY FOR DYSPLASTIC HIPS

Revision. Hip Stem. Surgical Protocol

AVANTEON. Operative Technique & Catalogue Information AVANTEON

Zimmer NexGen Tibial Stem Extension & Augmentation. Surgical Technique IMAGE TO COME. Stem Extensions and Augments

One system for all revision types

Comparative Study of Peripheral Rim Fixation Using Jumbo Cup in Revisional Hip Arthroplasty

SURGICAL TECHNIQUE. Alpine Cementless Hip Stem

NEXGEN COMPLETE KNEE SOLUTION S A. Tibial Stem Extension & Augmentation Surgical. ATechnique

Taperloc Complete Hip System. Surgical Technique

Encina Taper Stem. Stinson Orthopedics Inc. 303 Twin Dolphin Drive, Suite 600 Redwood City, CA

A further enhanced classic. Wagner SL Revision Hip Stem

FLH /11

The Treatment of Pelvic Discontinuity During Acetabular Revision

Cemented femoral stem - type CSC

ZMR Porous Revision Hip Prosthesis. Surgical Technique IMAGE TO COME

CAUTION: Ceramic liners are not approved for use in the United States.

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

Revision Total Hip Replacement

Aesculap Trilliance Triple Tapered Polished Hip Stem

ZMR Crossover Instruments. Abbreviated Surgical Technique

The Use of Computed Tomography to Determine Femoral Component Size

SUMMIT and DURALOC. Clinical Summary

FEMORAL REVISION IN TOTAL HIP ARTHROPLASTY

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

Peggers Super Summaries: THR and Revision Concepts

FIRST STEM SPECIFICALLY DESIGNED FOR AMIS. Surgical Technique

*smith&nephew SLR-PLUS

Fixed and Variable Geometry Total Shoulder Arthroplasty

Titanium Distal Femoral Nail System

ZMR CROSSOVER INSTRUMENTS AND SURGICAL TECHNIQUE. Surgical Technique for Revision Hip Arthroplasty

EMPERION Modular Hip System Surgical Technique

Tradition Hip Primary Surgical Technique

KEY CHOICES AND TECHNIQUES IN REVISION THA AND TKA Step-by-Step Decisions

Aesculap Targon FN. Head Preserving Solution for Medial Femoral Neck Fractures. Aesculap Orthopaedics

PLR. Proximal Loading Revision Hip System

Initial Evaluation on Subsidence of Cemented Collarless Polished Tapered Stem Applied to the Patients with Narrow Femoral Medullar Canal

Knee Revision. Portfolio

The effect of a lateral flare feature on implant stability

SURGICAL TECHNIQUE. Alpine Cemented Hip Stem

Case Report. Antegrade Femur Lengthening with the PRECICE Limb Lengthening Technology

HELIOS h i p s y s t e m

9/24/2015. Nailing IT Fractures: Long vs. Short Technique Tricks. Conflict of Interest. Short vs. Long Hip Nail

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year

Zimmer Segmental System

Tri-Lock Bone Preservation Stem

Surgical Technique.

VERSYS HERITAGE REVISION HIP PROSTHESIS. Surgical Technique for Revision Hip Arthroplasty

Revision Modular Stem type RMD

21st Century Fracture Management ETS. Surgical Protocol

Topology optimisation of hip prosthesis to reduce stress shielding

Transcription:

Journal of Orthopaedic Surgery 2003: 11(1): 53 58 The shape and size of femoral components in revision total hip arthroplasty among Chinese patients KY Chiu, TP Ng, WM Tang Department of Orthopaedic Surgery, Queen Mary Hospital, Pokfulam, Hong Kong HC Cheng Department of Orthopaedics & Traumatology, United Christian Hospital, Kwung Tong, Hong Kong TSL Hung, PYT Tse Department of Orthopaedics & Traumatology, Kwong Wah Hospital, Waterloo Road, Hong Kong PS Ko Department of Orthopaedics & Traumatology, Pamela Youde Nethersole Eastern Hospital, Chai Wan, Hong Kong ABSTRACT Purpose. 39 sets of preoperative hip X-rays were studied to find out whether Chinese patients need revision femoral components with a different shape and size from western patients. Methods. From July 1998 to June 2001, the pre-revision X-rays of 39 revision total hip replacements among 38 Chinese patients (21 men and 17 women) were studied. The component size that produced the best distal canal-filling in the anteroposterior X-ray was determined by using templates of 200-mm femoral components used commonly for Caucasian patients. Results. The diameter of the component needed was 13.5 mm or less in 54% of cases, compared with only 17% for Caucasian patients as reported in the literature (p<0.01). When lateral templates of the corresponding size were put over the lateral X-rays, the anterior cortex of the 200-mm straight stem was shown to have thinned by 2.0 mm or more in 36% of hips; for 200-mm bowed stem, there was thinning of the anterior cortex by 2.0 mm or more in only 5% of hips (p<0.01). Conclusion. Chinese patients are likely to need smaller femoral components than Caucasian patients, and may benefit from bowed-stem components in femoral revision. Key words: arthroplasty, replacement, hip; Chinese INTRODUCTION After failure of total hip arthroplasty, the proximal femur is compromised either mechanically (i.e. the bone support is weak) or biologically (i.e. the bone may not be viable). It is often not possible to use a cemented femoral component or a proximally porous-coated femoral component. However, the use of an extensively porous-coated femoral component can offer durable and reliable diaphyseal fixation. The re-revision rates for aseptic loosening of such femoral components Address correspondence and reprint requests to: Dr KY Chiu, Chief of Division of Joint Replacement Surgery, Department of Orthopaedic Surgery, The University of Hong Kong, Room 509, Professonial Block, Queen Mary Hospital, Pokfulam, Hong Kong. E-mail: pkychiu@netvigator.com

54 KY Chiu et al. Journal of Orthopaedic Surgery range from 0% to 6% after an average follow-up of 4 to 13 years. 1 8 For extensively porous-coated femoral components to work, it is important to have 4 to 6 cm of scratch fit or good canal fill in the diaphysis, so that the porouscoated part of the stem can be in close contact with good quality cortical bone. Moreland and Bernstein 6 reviewed 175 femoral revisions with such components. They found that bone ingrowth occurred in 83% of cases: 88% for components with complete canal fill but only 71% for components with incomplete fill. Krishnamurthy et al. 3 reported Paprosky s minimal 5-year results (mean, 8.3 years) of 297 femoral revisions. Bone ingrowth was achieved in 82% of patients and 16% had stable fibrous fixation; only about 2% had unstable fixation. The unstable femoral components were attributed to the use of undersized femoral components. Insertion of an extensively porous-coated femoral component that is long and straight into the medullary canal of a Chinese patient may not be straightforward. Femora in Chinese individuals have a narrower isthmus and a more pronounced anteroposterior (AP) bowing than femora in Caucasians. 9 Because the more pronounced AP bowing may be further aggravated by the remodelling changes to the loosened femoral component, insertion of a straight femoral component carries a risk of perforation to the anterior cortex distally (Figs. 1 and 2). In this study, we examined the pre-revision X-rays of 38 Chinese patients, with the aim of finding out how commonly small or bowed femoral components are needed for femoral revision in this group. Figure 1 A 66-year-old woman with loosening of a cemented Charnley femoral component, with extensive osteolysis over several zones (left). The femur was bowed, and the distal anterior cortex was thin and osteoporotic (right). Figure 2 A 200-mm straight-stem femoral component was used to bypass the proximal deficiency (left) of the same patient. The distal anterior cortex was probably violated (right).

Vol. 11 No. 1, June 2003 Femoral components in revision total hip arthroplasty for Chinese 55 MATERIALS AND METHODS The pre-revision X-rays of all revision total hip replacements performed by 7 joint replacement surgeons from 4 institutions, namely, Kwong Wah Hospital, Pamela Youde Nethersole Eastern Hospital, Queen Mary Hospital, and United Christian Hospital, from July 1998 to June 2001 were screened. Cases in which hemiarthroplasty or bipolar hip replacement were converted to total hip replacement procedures were excluded. To be included, both AP and lateral X- rays had to be available, in which about 30 cm of the proximal femur had to be visible. Because of the retrospective nature of the study, the distance of the beam to the table was not standardised, but it was about 100 cm in most cases. The pre-revision X-rays of 39 revision total hip replacements among 38 patients (21 men and 17 women) were suitable for this study. The mean age at the time of the revision was 63.1 years (standard deviation [SD], 14.2 years; range, 32 83 years). The failed femoral components were cemented in 33 hips and cementless in 6 hips. The reasons for revision were aseptic loosening in 33 hips, deep sepsis in 5 hips, and recurrent instability in one hip; 31 hips were first-time revisions, 7 were re-revisions, and one was a third revision. The templates of the Solution femoral components (Depuy, Leeds, UK) were used to guide the measurement of the canal widths and cortical thicknesses in the diaphysis, and to determine the sizes of the femoral components, the distal canal fill, and the possibility of erosion or perforation of the anterior cortex distally. The Solution femoral components come in 3 stem lengths: 152 mm (6-inch), 200 mm (8-inch), and 254 mm (10-inch). The 200-mm femoral components were used in this study because this size is most commonly used to bypass the proximal deficiency, and both straight-stem and bowed-stem templates are available. The smallest available 200-mm components are 10.5 mm in diameter for the straight stem and 13.5 mm in diameter for the bowed stem (the size increment is 1.5 mm). Firstly, we determined if a 200-mm component was to be inserted, the canal widths and cortical thickness at the level of the distal limit of the porous-coated surface. We identified the tip of the greater trochanter in the AP X-ray. The template of 200-mm stem was then put over the film such that the centre of the hip ball was at the same level as the tip of the greater trochanter. A transverse line that depicted the distal limit of the porocoat was then drawn over the X-ray. The process was repeated with the lateral X-ray. The thicknesses of the medial and lateral cortices and the mediolateral (ML) canal width were measured in the AP X-ray. The thickness of the anterior cortex and AP canal width were measured in the lateral X-ray. Secondly, we explored whether the distal anterior cortex could be jeopardised with the use of 200-mm straight femoral component, and whether a 200-mm bowed femoral component would be helpful. The AP X-ray was first templated, and the size of the 200-mm femoral component that would give the best distal fill was selected. The lateral X-ray was then evaluated with the straight-stem and bowed-stem lateral templates of the corresponding size. It was important that the template was placed in a standardised manner, so that the femoral component was just touching the endosteum of the anterior cortex proximally, and was just touching the endosteum of the posterior cortex in the middle segment. Special attention was given to the distal part of the femoral component in relation to the anterior cortex. Any erosion or even perforation of the anterior cortex was carefully quantified. Thirdly, we assessed the effect of sizing the femoral component by reversing the templating sequence. The lateral X-ray was first evaluated with the 200-mm straight-stem and bowed-stem lateral templates. The sizes of the femoral component that could theoretically be inserted without jeopardising the distal anterior cortex were determined. The corresponding sizes of AP 200-mm templates were then put over the AP X-ray. The proportion of the canal fill was then determined at the level of the distal limit of the porocoat, and at 5 cm proximal to it. The sizes determined by the lateral templating were also compared with the size of the femoral component that gave the best distal canal filling in the AP X-ray. The ruler on the 120% magnified template was used for the measurements of the cortical thicknesses and canal widths. There was no adjustment for variation in the X-ray magnification of the different sets of X-rays. The surgeons first measured and templated the X-rays from their own hospitals. Each set was then cross-checked by a surgeon from a different hospital. If there was any disagreement, the X-rays were measured and templated again by a surgeon from another hospital and so on, until consensus was reached. The data were analysed with Statistical Package for the Social Sciences (Windows version 10.0.1; SPSS Inc., Chicago, United States), using Pearson correlation, chi-square tests, and two-tailed t tests. Statistical significance was assumed if p value was less than 0.05.

56 KY Chiu et al. Journal of Orthopaedic Surgery RESULTS Dimensions at the distal limit of the porocoat At the level of the distal limit of the porocoat, the anterior cortex was 3.7 mm thick (SD, 1.4 mm; range, 1 8 mm), the medial cortex was 5.2 mm thick (SD, 2.5 mm; range, 1 14 mm), and the lateral cortex was 4.9 mm thick (SD, 1.8 mm; range, 1.0 8.5 mm). The anterior cortex was significantly thinner than the medial and lateral cortices at this level (p<0.001), which was clinically relevant, because the distal tip of the femoral component might jeopardise the cortex in this direction. At the level of the distal limit of the porocoat, the ML canal width in the AP X-ray averaged 14.9 mm (SD, 2.9 mm; range, 10 22 mm), and the AP canal width in the lateral X-ray averaged 15.6 mm (SD, 2.7 mm; range, 10.0 23.5 mm). There was a strong correlation between the 2 canal widths (r=0.66). For male patients, the medullary canal distally was oval at this level, with a mean AP canal width of 15.4 mm and a mean ML canal width of 14.1 mm. For female patients, the medullary canal distally had similar dimensions, with a mean AP canal width of 15.4 mm and a mean ML canal width of 15.6 mm. Component sizes determined from X-rays The distribution of the component sizes that gave the best distal canal fill in the AP X-rays is shown in Fig. 3. Small femoral components (<13.5 mm) were needed in 21 (54%) hips: 11 of 17 (65%) hips in females and 10 of 22 (46%) hips in males. The difference was not significant (p=0.32). Number of hips 12 10 8 6 4 2 0 10.5 12 13.5 15 16.5 18 19.5+ Sizes of femoral components (mm) Male Female Figure 3 Distribution of the sizes of the femoral components that allowed optimum distal canal filling in the AP X-rays. The effects of straight and bowed stems on the distal anterior cortex After the component size was determined from the AP X-ray, the lateral templates of the corresponding size were put over the lateral X-ray. Because there were no 10.5- and 12.0-mm templates for the bowed-stem femoral components, bowed stem measurements could not be made for 10 hips. For straight-stem femoral components, the distal anterior cortex was thinned out by an average of 1.1 mm (SD, 3.1 mm; range, -3 15 mm). If a bowed-stem femoral component was used, the distal stem tip was still 0.7 mm (SD, 2.2 mm; range, -7 4 mm) away from the endosteum of the anterior cortex. Because the mean thickness of the anterior cortex was only 3.7 mm, a further thinning of 2 mm or more would be undesirable. For straight stem femoral components, thinning of the anterior cortex by 2 mm or more would occur in 36% of hips. For bowed-stem femoral components, only 5% of hips would be so affected. The difference was statistically significant (p<0.01). The stem tip of straight-stem femoral components perforated through the anterior cortex in 4 (10%) hips. In contrast, the stem tip of a bowed-stem femoral component perforated through the anterior cortex in only one (3%) hip. Canal filling after lateral templating By putting a straight-stem lateral template over the lateral X-ray, the component size that best fitted the medullary canal without jeopardising the anterior cortex was determined. Compared with the component sizes determined by the AP templating, a femoral component that was 2 sizes smaller was needed in 3 hips, one that was one size smaller in 13 hips, a same-size component in 14 hips, and one that was one size bigger in 9 hips. Thus, 16 (41%) hips were downsized from the AP X-ray so as not to jeopardise the distal anterior cortex. In these 16 hips, the average canal fill in the AP radiographs was 86% at the level of the distal limit of the porocoat and 85% at the level 5 mm proximal to that. By putting a bowed-stem lateral template over the lateral X-ray, the component size that best fitted the medullary canal without jeopardising the anterior cortex was determined. Compared with the component sizes determined by the AP templating, a femoral component that was one size smaller was needed in 6 hips, a same-size component in 11 hips, and one that was one size bigger in 12 hips. Thus, 6 (21%) hips were downsized from the AP X-ray so as

Vol. 11 No. 1, June 2003 Femoral components in revision total hip arthroplasty for Chinese 57 not to jeopardise the distal anterior cortex. In these 6 hips, the average canal fill in the AP radiographs was 95% at the level of the distal limit of the porocoat and 80% at the level 5 mm proximal to that. The difference in the number of hips that had to be downsized between straight-stem and bowed-stem femoral components did not reach statistical significance (p>0.1). However, while it was at most one size smaller for the bowed-stem femoral component, it could be 2 sizes smaller for the straightstem femoral component. DISCUSSION Most revision cementless femoral components are straight, hence there is no need to have left and right components thereby reducing the inventory. A bowedstem femoral component is considered necessary only if it is exceedingly long. For the Solution system, 254-mm femoral components are bowed. Both straight and bowed stems are available for the 200-mm Solution femoral components. However, the bowed 200-mm Solution femoral components are said to be rarely needed, and are reserved for patients with unusual femora only. In this study, the 200-mm bowed-stem femoral components benefited more than 30% of Chinese patients by eliminating the chance of jeopardising the distal anterior cortex (Fig. 4). If one is not careful enough and inserts a straight, long stem into a bowed femur, it is possible to perforate the cortex distally (Figs. 1 and 2). If the latter occurs, there is a risk of postoperative fracture, because the tip of the femoral component stops at the same level as the cortical defect. One could argue that the risk of distal perforation could be minimised by performing templating in the lateral X-ray. However, we found that about 40% of the straight-stem femoral components would then be downsized, which led to suboptimal canal filling in the AP X-ray. The latter was the most important factor to achieve bone ingrowth. With a bowed-stem femoral component, the chance of downsizing was halved. Moreland and Bernstein 6 reviewed 175 femoral revisions with extensively porous-coated cementless stems. The mean patient age at revision was 62.4 years; 17% of femoral components were 13.5 mm or smaller in diameter, and 13% were 18 mm or larger. Krishnamurthy et al. 3 reported Paprosky s minimal 5-year results of 297 femoral revisions. The mean patient age was 59.6 years; 17% of femoral components were 13.5 mm or smaller in diameter, and 22% were 18 mm or larger. Our finding that more than half of the Chinese patients required a femoral component Figure 4 A 71-year-old man had loosening of the cemented Charnley femoral component. The lateral view of the femur appeared to be bowed (left). The diameter of the femoral component was 16.5 mm according to the 200-mm template in the AP X-ray. There was obvious violation of the anterior cortex distally when the 16.5-mm straight-stem lateral template was placed over the lateral X-ray (middle), but not with the 16.5-mm bowed-stem lateral template (right). that was 13.5 mm or smaller in diameter indicates that Chinese patients are likely to need small components. One should bear in mind that the patients in our series differed from those in the 2 western series. Firstly, this study was a radiological templating exercise and not actual surgery. Secondly, the number of hips was much less. The age at revision, on the other hand, was comparable, and the templates we used were those of the revision femoral components being implanted in the 2 western series. When a surgeon plans to use extensively porouscoated femoral components in revision total hip replacement, it is important to know the size and to find out whether the femoral canal is compatible with the use of a straight stem. To the best of our knowledge,

58 KY Chiu et al. Journal of Orthopaedic Surgery very few revision hip systems have bowed femoral components with moderate stem length. For the Solution femoral component, a bowed stem version is available for 200-mm femoral components. However, 10.5-mm and 12-mm diameter bowed-stem femoral components are not available in the Solution system. Perhaps such sizes are rarely needed in western countries, which are the system s most important markets. We hope that the manufacturers will reconsider the situation and provide their best support to surgeons performing joint replacements among Chinese patients so that the specific needs of these patients can be met. REFERENCES 1. Engh CA, Glassman AH, Griffin WL, Mayer JG. Results of cementless revision for failed cemented total hip arthroplasty. Clin Orthop 1988;235:91 110. 2. Engh CA, Glassman AH, Suthers KE. The case for porous-coated hip implants. The femoral side. Clin Orthop 1990;261: 63 81. 3. Krishnamurthy AB, MacDonald SJ, Paprosky WG. 5- to 13-year follow-up study on cementless femoral components in revision surgery. J Arthroplasty 1997;12:839 47. 4. Krishnamurthy AB, MacDonald SJ, Paprosky WG. Revision total hip arthroplasty. Long-term results without cement. Orthop Clin North Am 1993;24:635 44. 5. Lawrence JM, Engh CA, Macalino GE, Lauro GR. Outcome of revision hip arthroplasty done without cement. J Bone Joint Surg Am 1994;76:965 73. 6. Moreland JR, Bernstein ML. Femoral revision hip arthroplasty with uncemented, porous-coated stems. Clin Orthop 1995; 319:141 50. 7. Moreland JR, Moreno MA. Cementless femoral revision arthroplasty of the hip: minimum 5 years followup. Clin Orthop 2001;393:194 201. 8. Paprosky WG, Greidanus NV, Antoniou J. Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty. Clin Orthop 1999;369:230 42. 9. Fang D, Chiu KY, Remedios ID, Yin Q. Osteometry of the Chinese proximal femur. J Orthop Surg (Hong Kong) 1996; 4:41 5.