Leadless pacing. P.E. Vardas Professor of Cardiology University of Crete, Greece

Similar documents
Leadless pacing: Technical challenges and concerns. Panos Vardas President Elect of the ESC, Prof. of Cardiology, Heraklion University Hospital

Leadless Pacing. Osama Diab Assistant Prof. of Cardiology Ain Shams University Egypt

Lead Selection and Subcutaneous ICD Considerations. The Future of CIEDs

New generations pacemakers and ICDs: an update

Leadless pacemakers and subcutaneous ICD s: will we use them for most of our patients? K.-H. Kuck Asklepios Klinik St. Georg Hamburg, Germany

Pacemaker and ICD Re-use in AFRICA the Cape Town experience

INNOVATIONS IN DEVICE THERAPY:

UnitedHealthcare Medicare Advantage Cardiology Prior Authorization Program

Pediatric pacemakers & ICDs:

Cardiac Rhythm Management Coder 2018

Essentials of Pacemakers and ICD s. Rajesh Banker, MD, MPH

Pacing and Device Jargon Made Simple. Dr Jonathan Timperley MB ChB MD FRCP Consultant Cardiologist Northampton General Hospital

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Pediatric Pacemaker Implantation Endocardial or Epicardial

NOVEL DEVICE TECHNOLOGIES

ESC Stockholm Arrhythmias & pacing

PACEMAKER INTERPRETATION AND DEVICE MANAGEMENT PART I

EHRA Accreditation Exam - Sample MCQs Cardiac Pacing and ICDs

EBR Systems, Inc. 686 W. Maude Ave., Suite 102 Sunnyvale, CA USA

Supplemental Material

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

Recent Advances in Pacing and Defibrillation Harish Doppalapudi, MD

CRF procedure PROCEDURE FLOW. PATIENT ASSESSMENT Symptoms and indication. Pacemaker & ICD registration. Procedures. Procedure ICD.

PERIOPERATIVE MANAGEMENT: CARDIAC PACEMAKERS AND DEFIBRILLATORS

Finally, a pacemaker may be either permanent or temporary, which will also factor into your code selections.

Cardiac Rhythm Management Coder 2017

Call Medtronic at 1 (800) to verify the patient s current implanted system

Transvenous Pacemaker Procedures

Review of Pacemakers and ICD Therapy: Overview and Patient Management

Leadless pacemakers a panacea for bradyarrhythmias?

SUPPLEMENTAL MATERIAL

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

Practice Questions.

His Bundle Pacing in Bundle Branch Block May 11, 2017

MRI SureScan pacemakers & ICDs what you need to know

2009 CPT Codes for Cardiac Device Monitoring

Perioperative Management of Cardiac Implantable Devices

UnitedHealthcare, UnitedHealthcare of the River Valley and Neighborhood Health Partnership Cardiology Notification and Prior Authorization Program:

MRI and CIEDs. Disclosures

Cigna - Prior Authorization Procedure List Cardiology

Percepta CRT-P MRI SureScan W1TR01

Advisa MRI and Ensura MRI SureScan pacing systems

Cardiac Resynchronisation Therapy for all Patients Requiring Ventricular Pacing

Newer pacemakers also can monitor your blood temperature, breathing, and other factors and adjust your heart rate to changes in your activity.

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

CONSULTA CRT-P Model C4TR01

ΤΟ ΗΚΓ ΣΤΟΝ ΒΗΜΑΤΟΔΟΤΟΥΜΕΝΟ ΑΣΘΕΝΗ

NEIL CISPER TECHNICAL FIELD ENGINEER ICD/CRTD BASICS

EVOLUTION OF CARDIAC ELECTROPHYSIOLOGY

Is This Thing Working?

Technical option of surgical approach for trouble-shooting

Tachycardia Devices Indications and Basic Trouble Shooting

Size (mm) (H W D) Mass (g) Volume (cc)

COMMONLY BILLED CODES AND ASSOCIATED 2018 MEDICARE RATES

11/21/18. EKG Pop Quiz. Michael Giocondo, MD Cardiac Electrophysiology Saint Luke s Cardiovascular Consultants

CRM PRODUCT PERFORMANCE REPORT

INTERPRETING THE ECG IN PATIENTS WITH PACEMAKERS

EXTERNAL TEMPORARY PACEMAKERS

evicore cardiology procedures and services requiring prior authorization

MEDICAL POLICY Cardioverter Defibrillators

14ο Βορειοελλαδικό Καρδιολογικό Συνέδριο ΚΕΒΕ Βηματοδότηση: Νεότερες εξελίξεις Προοπτικές

Update on Device Innovation (S-ICD, Wearable, Leadless)

2010 Canadian Cardiovascular Society/ Canadian Heart Rhythm Society Training and Maintenance of Competency in Adult Clinical Cardiac

Puzzling Pacemakers Cheryl Herrmann, APN, CCRN, CCNS-CSC-CMC

ICD Diagnostics: Making the most of it

Cardiac rhythm detailed monitoring by an implanted pacemaker: The iecg solution

Ambulatory Monitors, Pacers, and Defibrillators

Figure 2. Normal ECG tracing. Table 1.

Technology Challenges for Active Cardiac Implantable Devices. Alain Ripart Senior VP and CSO

Case Report Intermittent Right Ventricular Outflow Tract Capture due to Chronic Right Atrial Lead Dislodgement

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

His Bundle Pacing: Where is it going? Kenneth A. Ellenbogen, M.D. Kontos Professor, VCU School of Medicine November 17, 2017

Procurement Support to Ministry of Health, Ukraine. Invitation to Bid for:

Clinical Data Summary: Avoid FFS Study

Active Fixation Models: 7740, 7741 and 7742 Passive Fixation Models: 7731, 7732, 7735 and 7736

MRI ACCESS. Evera MRI SureScan ICD Systems

09/05/2018. True/False: All pacemakers have defibrillation capabilities.

King s Research Portal

Pacing Without Wires: Leadless Cardiac Pacing

Cardiac implantable electronic devices (CIEDs) in children include pacemakers and implantable cardioverter defibrillators (ICDs).

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

ICD: Basics, Programming and Trouble-shooting

MRI conditional devices. A luxury or a real clinical need? Sophie Mavrogeni, MD, FESC Onassis Cardiac Surgery Center, Athens, Greece

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

1. CARDIOLOGY. These listings cannot be correctly interpreted without reference to the Preamble. Anes. $ Level

Diagnostic capabilities of the implantable therapeutic systems

BHRS Prep course Pub style Quiz NOT A

Different indications for pacemaker implantation are the following:

Programming of Bradycardic Parameters. C. W. Israel, M.D. Dept. of Cardiology Evangelical Hospital Bielefeld Germany

Dipartimento di Scienze Cardiovascolari Università Campus Bio-Medico di Roma Dott. Vito Calabrese

Chapter 80 Implantable Cardiac Devices

Advanced ICD Concepts

How to set up a device clinic for heart failure patients Dr C Sridevi

Solara CRT-P MRI SureScan W1TR06

AMPLIA MRI CRT-D SURESCAN DTMB1D4

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

What s New in CIEDs. Keimyung University Dongsan Medical Center Hyoung-Seob Park

You have a what, inside you?

You have a what, inside you?

Pacing Codes and Modes Concepts

Transcription:

Leadless pacing P.E. Vardas Professor of Cardiology University of Crete, Greece

DISCLOSURES Small teaching fees from: Bayer/J&J, Boeringer, Menarini Small consulting fees from: Medtronic

1957: First External Pacemaker

1958: First implanted pacemaker Elmquist Senning Larsson First implantable (Engineer) (Cardiologist) (Patient) pacemaker

Pacemakers (1957-2010) 5800 5858 Activitrax MicroMinix Thera EnPulse EnRhythm MRI First External Pacemaker Pediatric Asynchronous Pulse Generator Rate response Radically smaller size First Microprocessor-based, Mode switching Full automaticity MRI safe 1957 1970 1986 1990 1995 2004 2008 1960 1979 1989 1991 1998 2006 2010 First Implantable MDT Pacemaker Chardack-Greatbatch Byrel Dual chamber rate response Synergist Elite Rate response via activity & minute ventilation Kappa MVP, Full automaticity Adapta MVP, Full automaticity, MRI safe Advisa MRI

54 years after cardiac pacing is the only effective treatment for syncope due to symptomatic bradycardia

Milestones in Pacing 1960 s Durable permanent implants VVI and VAT modes Lithium-iodine battery cell 1970 s VDD and DDD pacing modes Rate-responsiveness 1980 s Microprocessors introduced Improved reliability of IPGs Steroid elution First ICD implant 1990 s-2000 s IS-1 connector standard Stored electrograms Biventricular pacing Transvenous implants ICD

Conventional sites of pacing leads Pacing from RA appendage Pacing from RV apex easy feasibility chronically stable mechanical positions stable stimulation thresholds

System proposed by Spickler in 1970

Questions that arise

Problems accompanying endocardial pacing

Leadless pacing technologies EBR technology Energy transfer from an ultrasound transmitter to a receiver electrode to achieve cardiac stimulation Induction technology Magnetic field generated from a transmitter unit to the receiver coil in the heart and converted directly into voltage pulses for stimulation Wireless electrical stimulation An implantable RF rechargeable bion microstimulator transmits command signals to the coil that generates direct electrical stimulation

Investigational stimulation system an ultrasound generator with an externally applied ultrasound transmission transducer a catheter incorporating a receiver electrode into the distal tip a data collection and display system Feasibility and safety of pacing using ultrasound energy JACC 2007

Induction technology The stimulation system consists basically of two components a transmitter unit (primary coil) implanted under the skin or the major pectoralmuscle just above the heart a small receiver unit (secondary coil) implanted in the right or left chamber of the heart The subcutaneous coil generates an alternating magnetic field and the receiver coil in the heart converts some fraction of the energy of this magnetic field directly into voltage pulses for stimulation Induction technology represents an energy transmission with an outstanding characteristic: very low energy loss Screw-equipped receiver unit without external connection Wieneke H et al, PACE 2009

Induction technology The complete control of the electrical pulse is in the transmitter unit The device can be programmed like a conventional pacemaker by telemetry pulse amplitude pulse duration frequency number of pulses Receiver unit mounted on an EP catheter positioned in the RV Receiver unit without external connection in the RV. The transmitter unit is placed on the outer thoracic wall directly beyond the receiver unit. Bottom: ECG tracing during wireless pacing

WiSE-CRT Study Wireless Stimulation Endocardially for CRT, 100 pts. Purpose: To evaluate the safety and performance of the WiCS-LV System in patients with indications for CRT. Primary Outcome Measures: Safety: Procedure and device-related adverse events Bi-ventricular pacing capture Inclusion Criteria: Patients with standard indication for CRT based upon the most recent guidelines AND meeting criteria for one of these three categories: PM and ICD upgrades LV lead failures Non responders http://clinicaltrials.gov/ct2/show/study/nct01294527

Leadless Pacing: Acoustic Energy WiSE Device: Receiver: 9 mm plus small lead, 0.05 cc Transmitter: implanted over the apex, connected to battery implanted in the abdomen

Leadless Pacemaker: Intracardiac Intracardiac VVIR pacemaker ~20F, ~24 mm length, 7-10 yr longevity Steerable Catheter +

Leadless Pacemaker: Intracardiac

Leadless pacing Comments Advantages Percutaneous catheter-based endovascular implant Precise placement in many locations True multisite ventricular stimulation Epicardial placement Possible endocardial left heart placement Reduced infection Reduced vascular occlusion Disadvantages Recharging energy source Compliance Travel Stability/embolization Complexity of follow up and programming

Novel technologies Biological pacemakers An approach to create a pacemaker in a cell that previously had little or no pacemaker function These approaches modify the electric signals generated by cardiac myocytes and/or specialized conducting cells to transform them into dominant pacemakers

Strategies to generate biological pacemakers Gene therapy overexpress a gene that will increase pacemaker rate in cardiac myocytes (by increasing inward current) knock out the function of a gene that would otherwise decrease pacemaker rate (and decrease outward current) Stem cell therapy Human embryonic stem cells-hescs Human mesenchymal stem cells-hmscs

Limitations for development of biological pacemaker Gene therapy-viral vectors Adenoviruses lead to only transient improvement in pacemaker function potential inflammatory responses Retroviruses risk of carcinogenicity and infectivity Stem cell therapy immunogenicity of cell potential for neoplasia proper engineering of pure cardiac lineages spatial non uniformity of implants need for an optimal cell mass and optimal cell-cell coupling for long term normal function