New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol

Similar documents
Evaluation of a Rapid Homogeneous Method for Direct Measurement of High-Density Lipoprotein Cholesterol

Separation of HDL Particles by Immunoprecipitation

1 Introduction Imprecision Within-run imprecision, results Day-to-day imprecision, results... 2

Comparison of a Homogeneous Assay With a Precipitation Method for the Measurement of HDL Cholesterol in Diabetic Patients

Patricia C. Fallest-Strobl, 1 Elin Olafsdottir, 2 Donald A. Wiebe, 1 and James O. Westgard 1 * Lipoproteins

ARTICLE. Utility of Direct Measurement of Low-Density Lipoprotein Cholesterol in Dyslipidemic Pediatric Patients

Comparison of two assays for measuring LDL cholesterol

(a) y = 1.0x + 0.0; r = ; N = 60 (b) y = 1.0x + 0.0; r = ; N = Lot 1, Li-heparin whole blood, HbA1c (%)

liquicolor Design Verification

Shinichi Usui, 1 Masakazu Nakamura, 2 Kazuhiro Jitsukata, 3 Masayuki Nara, 4 Seijin Hosaki, 1 and Mitsuyo Okazaki 4*

Serum LDL- and HDL-cholesterol determined by ultracentrifugation and HPLC

Serum low-density lipoprotein and high-density lipoprotein cholesterol. determined by ultracentrifugation and high-performance liquid

Evaluation of five methods for determining low-density lipoprotein cholesterol (LDL-C) in hemodialysis patients

Evaluation of Calculated Low-Density Lipoprotein Against a Direct Assay

Homogeneous assay for measuring low-density lipoprotein cholesterol in serum with triblock copolymer and -cyclodextrin sulfate

Katsuyuki Nakajima, PhD. Member of JCCLS International Committee

SCIEX Vitamin D 200M Assay for the Topaz System

In Vitro Diagnostic Glucose Test System

HDL CHOLESTEROL. 01 English - Ref.: 13. Ref.:13. Insert

LIPASE liquicolor. Design Verification. Multipurpose Reagent

3 Linearity and Detection Limit Linearity Detection limit... 4

For In Vitro Diagnostic Use. Rx Only. Reviewed by Date Reviewed by Date

liquicolor (AMP Buffer, IFCC) Design Verification

The Adiponectin Turbidimetric Immunoassay Reagent Kit

LDL . (LDL) Downloaded from ijdld.tums.ac.ir at 12:38 IRST on Friday February 1st 2019 LDL LDL NCEP-ATP-III (LDL) :

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000

Accuracy of Three Dry-Chemistry Methods for Lipid Profiling and Risk Factor Classification

Lipoprotein Quantification: An Electrophoretic Method Compared with the Lipid Research Clinics Method

Gentian Canine CRP Immunoassay Application Note for scil VitroVet*

METHOD VALIDATION: WHY, HOW AND WHEN?

Calibration of High-Density Lipoprotein Cholesterol Values From the Korea National Health and Nutrition Examination Survey Data, 2008 to 2015

1. Reagent Store at 2-8 ºC.

Lipid Profile Analysis of Aircrew

LDLC3. English System information For cobas c 311/501 analyzers:

USING THE ACCESS AMH ASSAY IN YOUR LABORATORY

For in vitro diagnostic use only. For Rx use only. Reviewed by Date Reviewed by Date

PLASMA LIPOPROTEINS AND LIPIDS DETERMINATION OF PLASMA CHOLESTEROL AND TRIGLICERIDE LEVEL

1. PROTOCOL. Comparison Study Summary. Tuality Healthcare 324 SE 9 th Ave. Suite E Hillsboro, OR July 30, 2014

LDL LD. 01 English - Ref.: 129. Ref.:129. Insert. Intended use. Methodology. Reagents. Test principle. Summary. Precautions and warnings

BÜHLMANN fcal turbo. Calprotectin turbidimetric assay for professional use. Reagent Kit B-KCAL-RSET. Revision date:

Determination of hemoglobin is one of the most commonly

IDEXX Catalyst One Chemistry Analyzer for In-house Measurement of Total Thyroxine (TT 4 ) Concentration in Serum from Dogs and Cats

行政院國家科學委員會補助專題研究計畫成果報告

Journal of Lipid Research Volume 22, 1981 Note5 on Methodology 1015

High-density Lipoprotein Cholesterol (HDL-C) Assay Kit

Technical Bulletin. Cholesterol Reference Method Laboratory Network (CRMLN) Overview. TB Rev. 0

Piccolo Lipid Panel Reagent Disc

AF HDL and LDL/VLDL Assay Kit

Kinetic assay of serum and urine for urea with use of urease and leucine dehydrogenase

Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)

A Leap above Friedewald Formula for Calculation of Low Density Lipoprotein Cholesterol

Walter B. Bayubay CLS (ASCP), AMT, MA Ed, CPI

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

Accuracy and Precision in Point-of-Care Lipid Testing: CardioChek P A Point-of-Care Test System and PTS Panels Test Strips

LIPID-ATHEROSCLEROSIS LABORATORY SERVICES GUIDE

Traceable lipoprotein counting for Cardiovascular disease risk assessment Vincent DELATOUR, PhD

Diagnostic reagent for quantitative in vitro determination of Urea / Blood Urea Nitrogen in serum, plasma and urine by colorimetry.

Free Fatty Acid Assay Kit (Fluorometric)

1 PROTOCOL. Comparison Study Summary. Springs Memorial Hospital. Springs Memorial Hospital 800 W. Meeting St. Lancaster, SC (803)

LDL (Human) ELISA Kit

This package insert contains information to run the Cholesterol assay on the ARCHITECT c Systems.

note on methodology I

ASSESMENT OF LOW-DENSITY LIPOPROTEIN CHOLESTEROL BY HOMOGENEOUS ASSAY VERSUS FRIEDEWALD S EQUATION - A STUDY OF 50 CASES.

ACCESS hstni SCIENTIFIC LITERATURE

1052 Technical Briefs

THE EFFECT OF VITAMIN-C THERAPY ON HYPERGLYCEMIA, HYPERLIPIDEMIA AND NON HIGH DENSITY LIPOPROTEIN LEVEL IN TYPE 2 DIABETES

Suppl. Table 1: CV of pooled lipoprotein fractions analysed by ESI-MS/MS

1 PROTOCOL. Comparison Study Summary

FreeStyle Lite A Blood Glucose Meter That Requires No Coding

Ingmar Jungner, 1* Santica M. Marcovina, 2 Göran Walldius, 3 Ingar Holme, 4 Werner Kolar, 1 and Eugen Steiner 1. Lipoproteins

Coverage Guidelines. NMR LipoProfile and NMR LipoProfile -II Tests

Apolipoprotein A1 (Apo A1) ELISA

Electrolyte Analyzer with Ion-Selective Electrode and Blood Gas analyzer

Comparison of Friedewald Formula and Modified Friedewald Formula with Direct Homogeneous Assay for Low Density Lipoprotein Cholesterol Estimation

6to. Congreso Virtual de Cardiología - 6th Virtual Congress of Cardiology

General Chemistry Scheme Guide

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Keywords: albuminuria; albumin/creatinine ratio (ACR); measurements. Introduction

A validation study of after reconstitution stability of diabetes: level 1 and diabetes level 2 controls

Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation

John J. Albers and Janet L. Adolphson

Depleting Lipoproteins from Serum

GUIDE TO THE EVALUATION OF COMMUTABILITY OF CONTROL MATERIALS

Statistical Considerations: Study Designs and Challenges in the Development and Validation of Cancer Biomarkers

Standard Operating Procedure

Free Glycerol Assay Kit (Colorimetric)

Forum for Collaborative HIV Research External Validation of CD4 and Viral Load Assays Paris, France June 29, 2007

EFFECT OF NICARDIPINE ON FASTING PLASMA LIPIDS AND APOLIPOPROTEINS IN MALE NEW ZEALAND WHITE RABBITS. Kamsiah Jaarin, Nafeeza MI*

Plasma Hemoglobin Determination: Two Manual Methods Compared. An Honors Thesis (HONRS 499) Anne M. Emerick. Sharlene Strahl. Beech Grove, Indiana

IDEXX Catalyst SDMA Test for in-house measurement of SDMA concentration in serum from dogs and cats

Development and Validation of a UV-Spectrophotometric Method for Quantification of Atorvastatin in Tablets

Rosuvastatin: An Effective Lipid Lowering Drug against Hypercholesterolemia

Friedewald formula. ATP Adult Treatment Panel III L D L Friedewald formula L D L = T- C H O - H D L - T G / 5. Friedewald formula. Friedewald formula

Week 17 and 21 Comparing two assays and Measurement of Uncertainty Explain tools used to compare the performance of two assays, including

APOB (Human) ELISA Kit

Bias in clinical chemistry. Elvar Theodorsson EFLM and Linköping University

Laboratory Investigation of Dyslipidemia

Method Comparison Report Semi-Annual 1/5/2018

Estimation of glucose in blood serum

Transcription:

Clinical Chemistry 44:7 1443 1451 (1998) Lipids and Lipoproteins New immunoseparation-based homogeneous assay for HDL-cholesterol compared with three homogeneous and two heterogeneous methods for HDL-cholesterol Matthias Nauck, * Winfried März, and Heinrich Wieland We evaluated four new commercial methods for HDLcholesterol determination. The three completely homogeneous assays were an immunoseparation-based (IS) method from Wako, a polyethylene glycol-modified enzyme (PEG) method from Boehringer Mannheim, and a synthetic polymer-based (SP) method from Genzyme. The fourth method was a new heterogeneous method in which lipoproteins are removed using dextran sulfatecoated magnetic beads and Mg 2 (MB, Reference Diagnostics). We compared these methods with the conventional phosphotungstic acid/mgcl 2 precipitation (PTA) procedure. The homogeneous assays had good intraassay imprecision with total CVs <2.3%, whereas the CVs of the MB assay were <5.9%. Adding HDL to serum to achieve HDL-cholesterol () concentrations up to 1000 mg/l revealed nearly complete recoveries in the IS, PEG, and MB assays, whereas the SP assay showed a lower recovery ( 70%). The SP apparently increased at increasing LDL-cholesterol and VLDL-triglyceride concentrations, whereas the IS, PEG, and MB methods were not influenced by LDL-cholesterol up to 6 000 mg/l (MB, 5 000 mg/l) and VLDL-triglycerides up to 9 000 mg/l. Free fatty acids above 2 mmol/l produced falsely high in the IS and SP assays, the error amounting to as much as 50% in some samples. An intermethod comparison in 291 fresh serum samples yielded correlation coefficients of at least r 0.95 for all assays, when compared with the PTA procedure. The slopes and intercepts of the regression lines were 1.05 and 57 (IS), 1.12 and 9.9 (PEG), 1.00 and 39 (SP), and 1.0 and 38 mg/l (MB), respectively. The new assays are precise and simplify the determination of, but in part they lack specificity or are susceptible to interferences, resulting in discrepancies when compared with the established PTA procedure. The positive association of coronary heart disease risk with total cholesterol and LDL-cholesterol (LDL-C) 1 concentrations and its negative association with HDL-cholesterol () concentrations are well established (1 4). concentrations 350 mg/l are considered as a cardiovascular risk factor; concentrations exceeding 600 mg/l may be protective (3). According to Friedewald et al. (5), together with total cholesterol and triglycerides, the determination of allows the calculation of LDL-C. For these reasons, reliable and easy-to-perform methods are needed to quantify. Most frequently, is measured in the supernatant after precipitation of apolipoprotein (apo) B-containing lipoproteins by phosphotungstic acid/mgcl 2 (PTA) or dextran sulfate (6, 7). All of these methods involve both a precipitation and a centrifugation step, which prevent full automation. Previously, new procedures for the determination of were published (8 12). They have in common that they avoid at least the tedious centrifugation step. In 1996, we published the results of an evaluation of a homogeneous assay that included polyethylene glycol (PEG) to complex the non-hdl lipoproteins (reagent 1); antibodies against apo B and apo C-III, which aggregate the non-hdl lipoproteins (reagent 2); enzymes for cholesterol determination (reagent 3); and guanidine hydrochloride to stop all reactions (reagent 4) (9). The performance characteristics of this method were good, but University Hospital of Freiburg, 79106 Freiburg, Germany. *Address correspondence to this author at: Department of Medicine, Division of Clinical Chemistry, Hugstetter Strasse 55, 79106 Freiburg i. Br., Germany. Fax 49-761-270 3444; e-mail manauck@mzl200.ukl.uni-freiburg.de. Received January 21, 1998; revision accepted March 17, 1998. 1 Nonstandard abbreviations: LDL-C, LDL-cholesterol,, HDL-cholesterol; apo, apolipoprotein; PTA, phosphotungstic acid/mgcl 2 precipitation; PEG, polyethylene glycol; IS, immunoseparation; SP, synthetic polymer; MB, dextran sulfate-coated magnetic bead; FFA, free fatty acid; and NCEP, National Cholesterol Education Program. 1443

1444 Nauck et al.: HDL-cholesterol methods the disadvantage of the procedure was that it relied on four different reagents, which limited its application to a small number of automatic analyzers. The aim of this study was to evaluate three homogeneous assays [an immunoseparation-based (IS) assay from Wako, a PEG-based assay from Boehringer Mannheim, and a synthetic polymer-based (SP) assay from Genzyme] and a dextran sulfate-coated magnetic beadbased (MB) procedure from Reference Diagnostics for the determination of in parallel with the conventional PTA assay with respect to precision, linearity, interferences, and ease of handling. Materials and Methods samples Blood was drawn from 291 in- and outpatients of the University Hospital of Freiburg, including nonfasting samples. The blood was allowed to clot at room temperature, and serum was obtained by centrifugation at 1500g for 15 min. All analyses with the homogeneous and the precipitation assays were performed within 1 day of blood collection. lipid measurements Cholesterol and triglycerides were determined enzymatically with the CHOD-PAP and GPO-PAP methods, respectively. These reagents were purchased from Boehringer Mannheim. All measurements, including the assays, were performed on a Boehringer Mannheim/Hitachi automatic analyzer type 911. Control sera Precinorm L and Precipath L (both from Boehringer Mannheim) were included in each analytical run. In addition, the nonesterified fatty acids were determined with the NEFA C assay, purchased from Wako, on a Wako 30R automatic analyzer in a subset of 130 samples. All tests, including the new homogeneous assays, were performed according to the manufacturers recommendations and calibrated using the standards included in the test kits. Reagents of the homogeneous assays were lyophilized and solubilized before use. is-based homogeneous hdl-c assay from wako The reagents for the IS assay were obtained from Wako. In this assay, anti-human apo B antibodies react with non- HDL particles, i.e., chylomicrons, VLDL, and LDL (reagent 1). These complexes do not react with the enzymes involved in the subsequent enzymatic cholesterol determination, whereas the cholesterol content of the HDL particles is measured (reagent 2). homogeneous hdl-c assay from boehringer mannheim based on peg-modified enzymes The reagents for the PEG assay were obtained from Boehringer Mannheim. At a neutral ph value (ph 7.0) and in the presence of MgCl 2, sulfated -cyclodextrin and dextran sulfate form water-soluble complexes with LDL, VLDL, and chylomicrons (reagent 1), which are not accessible to PEG-modified enzymes (reagent 2). Because HDL is not complexed, the cholesterol moiety is readily available for enzymatic quantification using cholesterol esterase and cholesterol oxidase coupled to PEG (8). sp-based homogeneous hdl-c assay from genzyme The reagents for the SP assay were obtained from Greiner Biochemica, Flacht, Germany. Synthetic polymers and polyanions adsorb to the surface of LDL, VLDL, and chylomicrons and convert these lipoproteins into denaturation-resistant complexes (reagent 1). In a second step, a detergent destroys the HDL structure, and the cholesterol content of the HDL particles is determined enzymatically (reagent 2) (11). mb-based hdl-c assay All reagents, cups, and tubes for this assay were obtained from Reference Diagnostics. In a flat bottom cup, 500 L of serum was incubated with 100 L of reagent containing 250 mmol/l Mg 2 and MBs. After the cups were mixed for a short period on a vortex-type mixer and incubated for 10 min, they were transferred to a magnet-containing tube, which was then directly placed in the Hitachi analyzer. The dextran sulfate binds all apo B-containing particles, which are pulled down in the magnetic field within 1 min. In severe hypertriglyceridemic samples, this separation can take up to 30 min. The cholesterol content of the HDL particles that remain in the supernate can easily be measured by the CHOD-PAP method. We applied a modified version of this assay, in which the accuracy at low cholesterol concentrations has been claimed to be improved by using a higher sample volume. The dilution of the sample was accounted for by multiplying the results by 1.2 (10). hdl-c determination by a pta-based method We used the PTA procedure as the comparison method. The reagents were purchased from Boehringer Mannheim. Two hundred microliters of serum were mixed with 500 L of the PTA reagent and incubated for at least 5 min. The apo B-containing lipoproteins were sedimented by centrifugation (5 min), and the cholesterol content was measured in the supernate with the CHOD-PAP method. hdl-c determination by a combined ultracentrifugation and precipitation method In 130 samples, a combined ultracentrifugation-precipitation assay was used as the comparison method. Essentially, the protocol of the Lipid Research Clinics Program was followed, with modifications previously described (13, 14). In brief, VLDL were floated by ultracentrifugation (density 1.006 kg/l), and the LDL was separated from the HDL in the infranatant by PTA.

Clinical Chemistry 44, No. 7, 1998 1445 isolation of vldl, ldl, and hdl, and preparation of lipoprotein-deficient serum VLDL, LDL, and HDL were isolated by sequential ultracentrifugation using density 1.006 kg/l, 1.006 density 1.063 kg/l, and 1.063 density 1.21 kg/l as density limits (15). Lipoprotein-deficient serum was obtained by 2 repeated ultracentrifugation at 150 000g for 48 h after adjusting the serum to density 1.25 kg/l by adding solid KBr. apo a-i Apo A-I was measured turbidimetrically on the Wako- 30R analyzer with reagents purchased from Greiner Biochemica. The assay was calibrated against the IFCC apo A-I standard. linearity Testing of linearity was performed by adding HDL isolated by ultracentrifugation to serum. To a constant volume of serum, increasing amounts of HDL were added. To modify the matrix as minimally as possible, the samples were brought to equal volumes with lipoproteindeficient serum. interferences The influences of LDL and VLDL on measurements were investigated in experiments in which they were added to samples. In addition, free fatty acids (FFAs) and bilirubin were measured in the samples of the intermethod comparisons. Interference from hemoglobin was analyzed according to Glick et al. (16). statistical methods Precision data were calculated according to recommendations of the NCCLS/EP5-T protocol (17). Regression analyses were performed using the method of Passing and Bablok (18). Total error was calculated as the sum of the systematic error plus random error (19, 20). Systematic error is calculated from the linear regression equation y c bx c a, where b is the slope of the regression line and aisthey-axis intercept. At an concentration of x c, systematic error is the absolute value of y c x c. Random error is 1.96 SD from the run-to-run precision study. Results precision Two commercial control sera with low and medium concentrations and one human serum pool were used to assess the precision of the assays (Table 1). The within-day imprecision values were determined as the average of the imprecision obtained each day. The between-day imprecision values were calculated from the imprecision of the means obtained each day, which were then adjusted for the within-day imprecision component. The total CVs ranged from 1.1% to 2.3% for the three homogeneous assays, from 3.9% to 5.9% for the MB assay, and from 3.1% to 3.7% for the PTA assay, respectively. linearity The new assays were linear up to at least 1000 mg/l, as revealed by increasing amounts of HDL prepared by sequential ultracentrifugation to sera (Fig. 1). For the SP assay, a slope of 0.7 was obtained when the Assay Sample a mg/l Mean, Table 1. Summary of the precision studies in control materials and a human serum pool. Within-day b Between-day Total c SD, mg/l CV, % SD, mg/l CV, % SD, mg/l CV, % IS HSP d 397.8 3.4 0.9 5.5 1.4 6.4 1.6 PNL 493.1 4.2 0.9 5.5 1.1 6.9 1.4 PPL 342.7 2.9 0.8 5.4 1.6 6.1 1.8 PEG HSP 357.9 2.3 0.7 6.0 1.7 6.4 1.8 PNL 468.3 2.4 0.5 4.3 0.9 4.9 1.1 PPL 315.8 1.8 0.6 6.9 2.2 7.1 2.3 SP HSP 388.7 3.5 0.9 5.0 1.3 6.1 1.6 PNL 488.4 4.0 0.8 3.6 0.7 5.4 1.1 PPL 398.4 2.8 0.7 4.3 1.1 5.1 1.3 MB HSP 336.7 7.4 2.2 10.9 3.2 13.2 3.9 PNL 390.2 10.2 2.6 20.5 5.3 22.9 5.9 PPL 251.0 6.1 2.4 12.3 4.9 13.7 5.5 PTA HSP 305.5 5.7 1.9 9.3 3.0 10.9 3.6 PNL 409.2 6.0 1.5 11.3 2.8 12.8 3.1 PPL 261.8 4.3 1.7 8.7 3.3 9.7 3.7 a Two control sera and one human pool serum were analyzed with each assay. Pools were divided into 300- L aliquots and stored at 4 C until tested. One aliquot of each pool was assayed in duplicate on each of 21 days. b Calculations for within-day and between-day SD were based on 21 samples; for within-day SD, calculations were based on a pair of 21 samples. c SD Total 2 SD W 2 SD B 2 ; where SD W within-day standard deviation, and SD B between-day standard deviation. d HSP, human serum pool; PNL, Precinorm L; PPL, Precipath L.

1446 Nauck et al.: HDL-cholesterol methods The PEG assay showed a minimal increase over the whole concentration range, but deviations 5% occurred only in samples with LDL-C above 6000 mg/l. LDL-C increased the values of the SP assay at any concentration. The MB assay was markedly influenced at LDL-C concentrations above 5000 mg/l. Cross-reactivity with VLDL also varied between assays. Triglycerides did not substantially interfere with the IS and PEG assays up to 9000 mg/l VLDL-triglycerides. The values of the SP assay increased over the whole concentration range, whereas VLDL-triglycerides interfered with the MB assay at concentrations of 5000 mg/l. Both the IS and the MB assays showed an unexpected negative bias with increasing VLDL-triglycerides. Fig. 1. Determination of : linearity and analytical recovery. Increasing amounts of HDL isolated by ultracentrifugation were added to a serum pool. The measured HDL increased linearly with the amounts of HDL added up to at least 1000 mg/l. The equations of the regression lines are: IS (f), y 0.98x 21.3; PEG ( ), y 0.99x 19.3; SP (F), y 70x 14.4; and MB (Œ), y 0.90x 23.1. measured was plotted against added, suggesting that the recovery of this assay was 100%. specificity concentrations are plotted against added LDL-C and VLDL-triglycerides, respectively, in Fig. 2. Cross-reactivity with LDL varied between assays. The IS assay was not influenced by LDL-C up to 6000 mg/l. intermethod comparisons As the comparison method, we used the PTA procedure either in whole serum (n 161), or after removal of VLDL by ultracentrifugation (n 130). A total of 291 fresh sera were analyzed with each of the new methods and the comparison method. Mean total cholesterol and total triglycerides were 1690 and 1680 mg/l, respectively. Maximum cholesterol and triglyceride concentrations were 3670 and 6830 mg/l, respectively. concentrations ranged between 35 and 906 mg/l, determined with the PTA method. The correlation coefficients were between 0.949 and 0.987 (Table 2). When we estimated the parameters of the regression lines according to Passing and Bablok, slopes relating the homogeneous IS and PEG assays to the PTA assay were significantly higher than 1.00 (P 0.05), whereas the SP and MB methods produced slopes close to 1.00 (18). All intercepts were significantly (P 0.05) different from 0.0 mg/l, which produced signif- Fig. 2. Specificity of the assays. Cross-reactivity with LDL (A) and cross reactivity with VLDL (B) in the IS (f), PEG ( ), SP (F), and MB (Œ) assays.

Clinical Chemistry 44, No. 7, 1998 1447 Assay Correlation coefficient Table 2. Summary of intermethod comparisons. a Slope Regression line Intercept PTA, x b New procedure for,y IS 0.980 1.05 c 56.8 d 336 414 e PEG 0.987 1.12 c 9.9 d 336 388 e SP 0.949 1.00 39.0 d 336 372 e MB 0.987 1.00 37.8 d 336 380 e a Regression analyses were done according to Passing and Bablok (18). b Concentrations are given in mg/l. c Slopes are significantly different from 1.00. d Intercepts are significantly different from 0.00. e The means were significantly higher, compared with the PTA method. icantly (P 0.05) higher values for all new methods, compared with the conventional precipitation procedure. The bias plots of the IS and PEG assays revealed small but systematic deviations, which increased slightly as concentrations increased (Fig. 3). At concentrations 350 mg/l, some of the IS results showed a deviation of approximately 200 mg/l, whereas the PEG assay produced only one outlier. The bias plot of the Fig. 3. Bias plots of (new assay minus PTA assay) in the IS (A), PEG (B), SP (C), and MB (D) assays.

1448 Nauck et al.: HDL-cholesterol methods SP assay showed substantial scattering over the entire range. The results of the MB assay were negatively biased throughout the entire concentration range, with only a small scattering. The correlation coefficients between the apo A-I measurements and the concentrations of the IS, PEG, SP, and MB assays were 0.92, 0.93, 0.89, and 0.93, respectively. total error The total errors were calculated at the decision points of 350 mg/l and 600 mg/l, respectively. As shown in Table 3, the systematic deviations contributed much more to the total errors than did the random errors. The highest total errors were found for the IS and PEG assays. free fatty acids Conditions with increased FFAs occur mainly in inpatients receiving intravenous heparin therapy. At concentrations 2 mmol/l, there is substantial binding of FFAs to lipoproteins (21). This increases the electrophoretic mobilities of the lipoproteins and may change their interaction with precipitating reagents (22 24). The results obtained in those serum samples of the intermethod comparisons that had FFA concentrations 2.0 mmol/l (n 22) indicated that the IS and SP assay were susceptible to interference from FFAs, whereas the assays from PEG and MB were not (Fig. 4). Experiments with samples enriched in FFA, according to the method of Spector and Hoak (25), completely confirmed these findings (data not shown). interferences Hemoglobin at concentrations up to 2 g/l did not interfere substantially with the new homogeneous Table 3. Total error for the new assays. Assay Systematic error, % Random error, % Total error, % IS 350 mg/l 21.2 1.1 22.3 600 mg/l 14.5 1.1 15.6 PEG 350 mg/l 14.8 1.4 16.2 600 mg/l 13.7 0.8 14.5 SP 350 mg/l 11.1 0.8 11.9 600 mg/l 6.5 0.7 7.2 MB 350 mg/l 10.8 2.4 13.2 600 mg/l 6.3 4.0 10.3 assays using IS and PEG (16). The SP assays yielded lower values, whereas in the MB and the PTA method increased markedly when hemoglobin was added (Fig. 5). Discussion As shown in many epidemiological and clinical studies, a low concentration of is an important risk factor for coronary artery disease (1). Thus far, has widely been determined by methods in which apo B-containing lipoproteins are precipitated with polyanions and bivalent cations. These methods are precise and agree well with ultracentrifugation methods but are tedious in respect to the centrifugation step involved (26, 27). Recently, several new assays have been devised which have with exceptions satisfactory performance characteristics (8 12). Here we present the results of a comparison study that included three principally different homogeneous assays: the first (IS) uses antibodies for the separation of non-hdl lipoproteins coupled to a conventional enzymatic cholesterol assay; the second (PEG) uses MgCl 2, sulfated -cyclodextrin, dextran sulfate, and PEG-coupled enzymes; the third (SP) uses synthetic polymers, polyanions, and detergents coupled with a conventional enzymatic cholesterol assay for the quantification of. The fourth method (MB) is based on the absorption of apo B-containing lipoproteins to dextran sulfate-coated magnetic beads. All of these assays were compared with the conventional PTA procedure. General advantages of the homogeneous methods are that they obviate pretreatment of the samples and that only small sample volumes are needed. These features allow the fully automated determination of even in the emergency laboratory, where may be useful in the diagnosis of serious infections, such as malaria, or to monitor patients after liver transplantation (28, 29). The National Cholesterol Education Program (NCEP) performance goals for 1998 demand that the CV of determinations be 4% at concentrations 420 mg/l (30), a criterion that was met by all investigated assays. The NCEP precision goal for concentrations 420 mg/l is a SD 17 mg/l (30). The homogeneous assays and the PTA procedure fulfilled these criteria. The MB assay produced a SD 17 mg/l in one of three pools examined. Thus, the NCEP precision goals will obviously be met by all homogeneous assays considered here at both high and low concentrations, whereas the MB assay may need further improvement. With regard to the precision, the differences between the three homogeneous assays are small and appear not clinically relevant. These data agree with previous publications (9 12). The slopes of the experiments with added HDL indicated nearly complete recoveries with the IS and PEG assay. Our data confirm that the specificity of the PEG method is good (10, 12, 30, 31). Furthermore, they indicate that the antibody concentrations of the IS assay are

Clinical Chemistry 44, No. 7, 1998 1449 Fig. 4. Interferences of FFAs with the determination of (ratio, new assay/pta assay) in the IS (A), PEG (B), SP (C), and MB (D) assays. Fig. 5. Interferences of hemoglobin with the IS (f), PEG ( ), SP (F), MB (Œ), and PTA (E) assays, tested according to Glick et al. (16). sufficient to complex all non-hdl particles. The specificity of the IS assay is thus at least as good as that of the homogeneous from International Reagents Corporation, Kobe, which also contains antibodies to form stable aggregates of the non-hdl lipoproteins. The latter method, however, has the disadvantage of including four different reagents (8). On the other hand, only 70% of the added HDL was recovered with the SP method. The addition of LDL and VLDL produced falsely high concentrations, indicating limited specificity of this method, as described previously (11, 12). The MB assay was specific, but the interferences from LDL-C and VLDL-triglycerides started at lower concentrations than in the IS and PEG assays. Recently, Demacker et al. (27) showed that the PTA procedure agrees well with the CDC reference method. Therefore, and because the PTA procedure is very common in laboratories, it is well suited as a comparison method. We obtained excellent correlation coefficients when we compared the homogeneous assays with the PTA procedure. The slope of the IS assay was 1.00, which caused the positive slope of the bias plot (Fig. 3). This was due to a

1450 Nauck et al.: HDL-cholesterol methods falsely high specification of the calibrator provided by the manufacturer, so that the results do not exactly agree with the PTA procedure. In a previous premarketing evaluation of the PEG assay, a positive bias of 3% was observed (31). The optimistic data of this previous multicenter study were not reproduced in the current study. The PEG assay showed a slope significantly (P 0.05) exceeding unity. This deviation was due to a falsely high declaration of the calibrator, which may have occurred on large-scale production. Finally, a very recently performed evaluation of the PEG method performed in our laboratory showed that the positive bias had disappeared, indicating that this assay is now working well (y 0.98x 11.9 mg/l; r 0.997; n 100). The unsatisfactory results of the SP assay have been reported by other investigators as well (11, 12). The low specificity of this assay is hampering the use of this method in the clinical chemical laboratory, in spite of the good imprecision and a slope of 1.0 in the intermethod comparison. The scattering of the bias plots, caused by the nonspecificity of this method, is not acceptable. The MB assay showed the best agreement with the comparison method, including an ideal slope of 1.0. It is worth noting that all results of the MB assay were slightly higher than the PTA procedure, caused by a small positive intercept of the regression line. The NCEP goals for 1998 demand a total error of 13% (30). In the current study, the IS and PEG homogeneous assays have not met these criteria because of high systematic error caused by an incorrect calibration (slopes 1 plus a positive y-intercept in the intermethod comparison). The SP assay had the lowest total error because of a very small systematic error. Obviously, the limited specificity of the SP assay for HDL is balanced by a suitable calibrator, which accounts for the fact that LDL-C and VLDL-C are in part determined as. The MB assay meets the NCEP criteria, the total error amounting to 13.2% at 350 mg/l. A common denominator of the present study and of many earlier reports is that homogeneous assays tend to overestimate in the range of 10%. This raises the suspicion that homogeneous assays may yield an HDL fraction that differs in some respect from HDL found in the supernate of precipitation reactions. Such a systematic difference between homogeneous and conventional methods would not be entirely surprising. HDL represents a polydisperse system of particles markedly differing by physicochemical characteristic, apolipoprotein composition, and pathobiochemical importance. On the basis of their apo E content, two populations of HDL particles can be distinguished, those without apo E and those with apo E. The latter accounts for 10% of the total. In the PTA assay, the apo E-containing HDL particles are precipitated and therefore not included in the (32). In the homogeneous PEG assay, in contrast, these particles contribute to (33), a finding that may at least in part account for the bias found between the homogeneous and the precipitation methods. It is currently not known how different HDL subfractions behave in the other homogeneous methods. What are the consequences of these differences in practice? The large epidemiological studies, which established the role of low concentrations as a risk factor of coronary artery disease, were performed with precipitation methods adjusted to the CDC reference method. These studies will probably not be repeated in the future because they are expensive and the results would be biased through the widespread use of lipidlowering therapies, even in primary prevention. It will probably not be feasible to change the cutoff point for from 350 (without apo E-containing ) to 380 mg/l (including apo E-containing ). More pragmatic, however, will be adjusting the new methods to the CDC reference method (31, 34), thereby deliberately disregarding the fact that the homogeneous assays yield an HDL fraction that may physicochemically be distinct from HDL produced by precipitation reactions. The reagents for the homogeneous assay are approximately threefold more expensive than conventional precipitation reagents. With the exception of the SP assay, the homogeneous assays evaluated here are convenient to use in routine laboratories. The MB assay, which also avoids centrifugation, is substantially cheaper than the homogeneous assays and therefore represents an alternative for laboratories with a workload of 50 samples per day. However, in most laboratories, the higher reagent costs for the new assays will probably be offset by economizing the laboratory work. In summary, the homogeneous IS and PEG assays produce precise and accurate determinations of. Even hypertriglyceridemic samples up to at least 9000 mg/l revealed unbiased results. The MB assay showed the best agreement with the PTA procedure, except in of hypertriglyceridemic and hemolytic samples. This assay is cheaper than the homogeneous assays but is not fully automated. All new assays, with the exception of the SP assay, represent a major improvement in our methodology to quantify and may facilitate the identification of individuals at increased risk of atherosclerosis. Although it was the only homogeneous assay to meet the NCEP performance goals, the SP assay proved nonspecific and is therefore not recommended for use in the clinical laboratory. We are grateful for the excellent technical assistance of Gabi Herr, Brigitte Kreisel, and Sibylle Rall. We also thank Wako, Boehringer Mannheim, Greiner, and Reference Diagnostics for providing assay kits free of charge.

Clinical Chemistry 44, No. 7, 1998 1451 References 1. Law MR, Wald NJ, Thompson SG. By how much and how quickly does reduction in serum cholesterol concentration lower risk of ischaemic heart disease? Br Med J 1994;308:367 72. 2. Wilson PW, Abbott RD, Castelli WP. High density lipoprotein cholesterol and mortality. The Framingham Heart Study. Arteriosclerosis 1988;8:737 41. 3. National Cholesterol Education Program. Second report of the expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (adult treatment panel II). Circulation 1994; 89:1330 445. 4. International Task Force for Prevention of Coronary Heart Disease. Prevention of coronary heart disease: scientific background and new clinical guidelines. Recommendations of the European Atherosclerosis Society. Nutr Metab Cardiovasc Dis 1992;2:113 56. 5. Friedewald WT, Leva RJ, Fredrickson DS. Estimation of the concentration of low density lipoprotein cholesterol in plasma, without use of preparative ultracentrifuge. Clin Chem 1972;18:499 509. 6. Warnick GR, Cheung MC, Albers JJ. Comparison of current methods for high density lipoprotein cholesterol quantification. Clin Chem 1979;25:596 604. 7. Demacker PNM, Vos-Janssen HE, Hijmans AGM, van t Laar A, Janssen AP. Measurement of high-density lipoprotein cholesterol in serum: comparison of six isolation methods with enzymatic cholesterol analysis. Clin Chem 1980;26:1780 6. 8. Sugiuchi H, Yoshinori U, Okabe H, Irie T, Uekama K, Kayahara N, Miyauchi K. Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol-modified enzymes and -cyclodextrin. Clin Chem 1995;41:717 23. 9. Nauck M, März W, Haas B, Wieland H. Homogeneous assay for direct determination of high-density lipoprotein cholesterol evaluated. Clin Chem 1996;42:424 9. 10. Harris N, Galpachian V, Rifai N. Three routine methods for measuring high-density lipoprotein cholesterol compared with the reference method. Clin Chem 1996;42:738 43. 11. Harris N, Galpachian V, Thomas J, Iannotti E, Law T, Rifai N. Three generations of high-density lipoprotein cholesterol assays compared with ultracentrifugation/dextran sulfate-mg 2 method. Clin Chem 1997;43:816 23. 12. Huang YC, Kao JT, Tsai KS. Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol. Clin Chem 1997;43:1048 55. 13. Manual of laboratory operation. Lipid Research Clinics Program. DHEW No. (NIH) 75 628. Bethesda, MD: National Heart and Lung Institute, 1974:1 74. 14. Wanner C, Hörl WH, Luley C, Wieland H. Effects of HMG-CoA reductase inhibitors in hypercholesterolemic patients on hemodialysis. Kidney Int 1991;39:754 9. 15. Havel RJ, Eder HA, Bragdon JH. The distribution and chemical composition of ultracentrifugally separated lipoproteins in human plasma. J Clin Invest 1955;34:1345 53. 16. Glick MR, Ryder KW, Jackson SA. Graphical comparisons of interferences in clinical chemistry instrumentation. Clin Chem 1986;32:470 5. 17. NCCLS. User evaluation of precision performance of clinical chemistry devices. Tentative Guideline EP5-T. Villanova, PA: National Committee for Clinical Laboratory Standards, 1984. 18. Passing H, Bablok W. Comparison of several regression procedures for method comparison studies and determination of sample size. Part II. J Clin Chem Biochem 1984;22:431 45. 19. Carey RN, Garber CC. Evaluation of methods. In: Kaplan LA, Pesce AJ, eds. Clinical chemistry: theory, analysis and correlation, 3rd ed. St. Louis: CV Mosby, 1996:402 23. 20. Westgard JO, Carey RN, Wold S. Criteria for judging precision and accuracy in method development and evaluation. Clin Chem 1974;20:825 33. 21. Nauck M, März W, Wieland H. Adding albumin normalizes electrophoretic mobility of lipoproteins in sera with high concentrations of free fatty acids. Clin Chem 1996;42:1283 5. 22. Armstrong V, Seidel D. Evaluation of a commercial kit for the determination of LDL cholesterol in serum based on precipitation of LDL with dextran sulfate. Ärztl Lab 1985;31:325 33. 23. Nauck M, Friedrich I, Wieland H. Measurement of LDL and VLDL cholesterol with precipitation techniques. A comparison with the ultracentrifugation method. Klin Lab 1994;40:167 76. 24. Siekmeier R, März W, Gross W. Insufficient accuracy and specificity of polyanion precipitation methods for quantifying low-density lipoproteins. Clin Chem 1990;36:2109 13. 25. Spector AA, Hoak JC. An improved method for the addition of long-chain free fatty acid to protein solutions. Anal Biochem 1969;32:297 302. 26. März W, Gross W. Analysis of plasma lipoproteins by ultracentrifugation in a new fixed angle rotor: evaluation of a phosphotungstic acid/mgcl 2 precipitation and a quantitative lipoprotein electrophoresis assay. Clin Chim Acta 1986;160:1 18. 27. Demacker PNM, Hessels M, Toenhake-Dijkstra H, Baadenhuijsen H. Precipitation methods for high-density lipoprotein cholesterol measurement compared, and final evaluation under routine operating conditions of a method with a low-to-reagent ratio. Clin Chem 1997;43:663 8. 28. Nilsson-Ehle I, Nilsson-Ehle P. Changes in plasma lipoproteins in acute malaria. J Intern Med 1990;227:151 5. 29. Nikkila K. Liver transplantation restores low serum levels of very low density and high density lipoproteins in end-stage primary cirrhosis. Ann Med 1992;24:129 36. 30. Warnick GR, Wood PD for the National Cholesterol Education Program Working Group on Lipoprotein Measurement. National Cholesterol Education Program recommendations for measurement of high-density lipoprotein cholesterol: executive summary. Clin Chem 1995;41:1427 33. 31. Nauck M, März W, Jarausch J, Cobbaert C, Sägers A, Bernard D, et al. Multicenter evaluation of a homogeneous assay for HDL cholesterol without sample pre-treatment. Clin Chem 1997;43:1622 9. 32. Okamoto Y, Tsujii H, Haga Y, Tanaka S, Nakano H. Determination of apolipoprotein E in high-density lipoprotein fraction by immunofixation method and turbidimetric immunoassay after precipitation. J Atheroscler Thromb 1994;1:23 9. 33. Okamoto Y, Tanaka S, Nakano H. Direct measurement of HDL cholesterol preferable to precipitation method. Clin Chem 1995; 41:1784. 34. Warnick GR, Wood PD. National Cholesterol Education Program recommendations for measurement of high-density lipoprotein cholesterol: executive summary. Clin Chem 1995;41:1427 33.