What s New in itero Scanner 4.0

Similar documents
Using the Eraser Tool for Occlusal Reduction

itero Troubleshooting Guide Version itero troubleshooting guide

Protocol for 3Shape TRIOS

fusion treatment is powered by suresmile technology to provide 3D models and fully-customized wires based on your scans of the patient.

Connect your Scanner to SomnoMed Canada. SOMGauge Protrusive Bite Recording - Manual. Scanning Impressions - Lower and Upper

fusion treatment is powered by suresmile technology to provide 3D models and fully-customized wires based on your scan of the patient.

Protocol for itero and ioc

< > INVISALIGN OUTCOME SIMULATOR QUICK REFERENCE GUIDE. Home Contents Overview Important Notes. STEP 1 Scan Patient s Teeth Submit Scan

Table of Contents D4D Technologies LLC All rights reserved A Table of Contents

CEREC CONNECT. Omnicam and Bluecam Workflow and Upload Instructions for Sending Cases to the Laboratory

CEREC CONNECT. Omnicam and Bluecam Workflow and Upload Instructions for Sending Cases to the Laboratory

CS User and Installation Guide

TRIOS BY 3SHAPE HOW TO PROVIDE 3SHAPE TRIOS INTRAORAL SCANS FOR THE PRODUCTION OF SOMNODENT DEVICE. KEY QUESTIONS: 1 How do I send my case?

Impression Manual.

Fully Automated IFA Processor LIS User Manual

How to provide intraoral scans to SomnoMed for the production of SomnoDent device.

itero Orthodontic Scanner

CS 3600 / CS 3600 ACCESS A SMARTER WAY TO SCAN INTRAORAL SCANNING

Not just digital itero. The path to the perfect fit. 3 CAD modeling created by laboratory. 1 Digital scan by dentist. 2 Real-time chairside feedback

3Shape TRIOS Scanner

Release Notes DWOS Lava Edition

Available for CEREC SW, inlab CAD SW, 3Shape, Dental Wings, DWOS Lava Edition, exocad, Open design software. Atlantis. Atlantis Core File.

Contents. Quick Start Guide

IOS & The Sirona Connect System Clinician Procedure

ClinCheck Fact Sheet.

CLINICAL CONSIDERATIONS CROWDING

Demo Mode. Once you have taken the time to navigate your RPM 2 app in "Demo mode" you should be ready to pair, connect, and try your inserts.

Digital Impression Scanning

Chairside Reference Guide

TASKS. 2. Apply a disclosing agent to make the plaque visible.

Straumann CARES Visual 9

Making a Room Reservation with Service Requests in Virtual EMS

FRAMEWORK MANAGEMENT. _ Construction of temporaries Instruction for use

CEREC Implants Acquisition Phase

Entering HIV Testing Data into EvaluationWeb

ProMax 3D Scanning Protocol

DENTRIX ENTERPRISE 8.0.5

User Instruction Guide

CEREC v3.8 Biogeneric Software. by Dr Simon Smyth

SureSmile protocol. CEREC Scanner with Omnicam

What s NEW. in 3Shape Dental System 2017

Treatment Planning: Visualization Software ClinCheck. min45

artegral ImCrown manual

EWOO Picasso Trio Scanning Protocol

EDUCATIONAL TECHNOLOGY MAKING AUDIO AND VIDEO ACCESSIBLE

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

Scanora 3D Scanning Protocol

ProScript User Guide. Pharmacy Access Medicines Manager

Contour Diabetes app User Guide

Using SPSS for Correlation

Lesson 2 EMG 2 Electromyography: Mechanical Work

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

HOW TO USE THE BENCHMARK CALENDAR SYSTEM

IMPRESSION PROCEDURES TRAINING MANUAL

You can use this app to build a causal Bayesian network and experiment with inferences. We hope you ll find it interesting and helpful.

your talent. our technology. the perfect fit.

CEREC Guide 2.0. Brent Pedersen, CEREC Technology Advisor/Trainer Joe Perry, Sirona 3D Regional Manager

FASTDESIGN. System. Same-Day Dentistry has never been this easy and affordable. Technologies, Inc. INTRODUCING THE

6610 NE 181st Street, Suite #1, Kenmore, WA

Dental Morphology and Vocabulary

Tooth and Surface Identification (TID and SID)

Invisalign G4 FAQs. General:

INTRAORAL SCANNER TRANSFORMING CREATIVITY

Invisalign Quick Start Guide. ClinCheck plan review. Dedicated to help you treat with confidence.

Reporting Nonviable MDH Vaccine to MIIC

[HEALTH MAINTENANCE AND INVITATIONS/REMINDERS] June 2, 2014

Advance Dental Simulation Module on Crown Preparation

Summary. DWOS 3.6 new features. Version 1.3. February 27, 2014

PH-04A: Clinical Photography Production Checklist With A Small Camera

COMPLETING ONLINE EHS COURSES

áåi~ä=pa=ñçê=^äìíãéåíë=spksu

v Feature Stamping SMS 12.0 Tutorial Prerequisites Requirements TABS model Map Module Mesh Module Scatter Module Time minutes

User Manual. RaySafe i2 dose viewer

Instructor Guide to EHR Go

mehealth for ADHD Parent Manual

MEAT CONTENT CALCULATION

Diabetes Management App. Instruction Manual

Introducing a NEW update for the in-office design software that facilitates better outcomes

USER GUIDE: NEW CIR APP. Technician User Guide

SPAMALIZE s Cerebellum Segmentation routine.

Content Part 2 Users manual... 4

v Feature Stamping SMS 13.0 Tutorial Prerequisites Requirements Map Module Mesh Module Scatter Module Time minutes

LiteLink mini USB. Diatransfer 2

SICAT AIR & OPTISLEEP. The appliance-based 3D solution for the treatment of obstructive sleep apnea

Lava. Chairside Oral Scanner C.O.S. The Future in Motion

Instructions for CT Scanning

The Comprehensive Treatment Management System

Invisalign Quick Start Guide I.

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

MemRx Orthodontic Appliances

Bruker D8 Discover User Manual (Version: July 2017)

GuidedService. The ultimate guide for precise implantations

Audit Firm Administrator steps to follow

Feature Stamping SURFACE WATER MODELING SYSTEM. 1 Introduction. 2 Opening a Background Image

ATLANTIS WebOrder. ATLANTIS ISUS User guide

What s NEW in Version 4.6

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

Transcription:

What s New in itero Scanner 4.0

New User Interface itero has a new user interface with a completely new look and feel. The new user interface is designed to: - Maximizes the use of available screen space - Enhance visualization of the 3D model - A more intuitive user interface - Improve case workflow

New User Interface

New User Interface

Login Login into itero/cm is now done with MyCadent accounts - Select your User Name - Enter your Email and Password, as you do in MyCadent - Press Sign In

Login On selecting User Name, if user had a previously successful login: - Email field will be filled automatically - If Remember Login was checked previously, Password field will be filled automatically If you do not have an account in MyCadent, you can create one using the login dialog. - Press Don t Have MyCadent Account and the dialog will display additional options. - Select your name from the Username drop-down list. - Press Create Account. Legacy login style will still be enabled for a while - Select your User Name - Press Don t Have MyCadent Account and the dialog will display additional options - Press Skip Login

RTM Scanning Protocol Goals - Real time buildup and visualization of the 3D model - Doctor sees a high quality 3D image (merging, hole-filling) - Simplify capture of the margin area in multi-unit cases Rx - Same case types, but scanned in RTM mode Quadrant (RTM) Expanded (RTM) Full arch (RTM) Reference Model (RTM) - Rx enables user to choose scanning order Prep jaw first or opposite jaw first Prep tooth first or arch first.

RTM Scanning Protocol Scan Tool - Scanning divided into segments For example Quadrant (RTM) has 7 segments: - Lower Buccal and Lower Lingual - Upper Buccal and Upper Lingual - Prep Tooth and Prep Tooth Contacts -Bite - User is guided through the segment, as in previous scanning protocols Scan positions are updated quickly after each scan is taken Unregistered scans are shown at the top in a red frame Additional operations are available through the left pedal menu - Next to advance to the next segment - Undo to delete the last scan that was taken in the current segment - Rescan Segment to delete all scans in the current segment - Prev to return to previous segment - Delete Unregistered to delete all scans that have not registered successfully - View to enter the View Tool There is a limitation of maximum number of scans per segment - When scanning of a segment is finished User should wait until all registration is finished or until registration fails User can use Next to move to the next segment or Add Scans if more scans required System will Add Scans automatically if a scan has failed registration - User is responsible for capturing all necessary information - Unregistered scans are deleted upon leaving a segment

RTM Scanning Protocol Scanning of Prep - The goal is to capture the margin area and the entire preparation - Scans should be taken immediately after the cord is pulled out - In multi-unit cases, each prep tooth is scanned separately - User should take as few scans as possible - In case of prep first, we reuse prep scans to build the arch - Color overlay is shown only on the first prep scan, and only when no other scan is visible - During scanning, prep scans are displayed in high resolution. All the rest are displayed in preview resolution. - Contact scans (interproximals) participate in both prep model and arch model - Automatically spin the model for review at the end of a prep segment Prep Occlusal Clearance - Can be calculated and shown if user scans Opposite Jaw First - After the prep is scanned, the left pedal menu will contain Occlusal Clearance - Upon choosing this command User will be guided to take bite scan Bite scan will be registered Occlusal Clearance will be computed and shown - If needed, doctor can reduce the prep tooth some more and then go back and rescan it

RTM Scanning Protocol View Tool - Multiple Merge surfaces in RTM View Tool Special visualization of preps with arches Buttons to Zoom on active prep tooth, show it separate - Prep Registration If the prep is not registered to the arch a pop up window will ask for assistance to register the scan segments The process is performed by clicking the general prep location within the arch to assist registration To prevent this, it is important to follow scanning guidelines: The buccal and lingual scans have to be captured parallel to the arch, and at a tilt of 45 degrees. The tip of the scanner should always be pointed to the distal of the current segment. - Eraser Tool User can erase an area on a single merge surface, either arch or prep, and fill it by a single scan or more Note: These scan(s) will only fill the erased area without affecting surrounding surfaces - Sending of RTM model RTM model can be sent only if all preps stitched to arches and merge was successfully performed on all surfaces By sending the RTM model, doctor approves the quality of sent model

RTM Scanning Guidelines and Troubleshooting Many scans don't stitch, inside a segment: - Take a scan with large overlap to the last successful scan in the segment. To achieve more overlap, the scanner tilt and orientation are also important not only the cross position. You want to tilt and orientation of the scanner to be close to that of the previous scan, in order to guarantee registration success. - If you reach the maximum allowed number of scans, use Delete Unregistered to continue trying. - If adding scans s with overlap doesn't help Use Rescan Segment and start over It makes sense to do so, because it is possible that one of the successful scans is bad (e.g. distorted, or taken from the wrong side of the mouth), therefore adding scans will never succeed - Do not use Next Modeling will not be able later to fix these problem for you If you do, all scans that didn't stitch will be deleted, and you will have to rescan them later

RTM Scanning Guidelines and Troubleshooting None of the Lingual scans stitch (Buccal side scanned) - Take an occlusal scan of a posterior tooth This increases the overlap with the buccal side -In Expanded cases, this may happen on the side of the jaw where you only need to scan anteriors (up to cuspids) The lingual and buccal views of the cuspid do not have enough overlap Take an occlusal scan of the cuspid If this doesn't help, tilt the scanner more towards the buccal side until it succeeds - If you reach the maximum allowed number of scans, use Delete Unregistered to continue trying - If nothing works, try to see whether the buccal scans are OK If you suspect that they might contain wrong data, go to the buccal segment and use Rescan Segment to rescan the buccal side - Do not use Next Modeling will not be able later to fix these problem for you If you do, all scans that didn't stitch will be deleted, and you will have to rescan them later

RTM Scanning Guidelines and Troubleshooting Jaw sides (right and left) do not stitch together - Make sure that both segments (right buccal and left buccal) contain information of the centrals Add scans to one of these segments if it doesn't - Continue scanning the lingual sides (right lingual and left lingual) There is a good chance that the system will succeed in stitching right-left based on lingual scans - If problem persists, try to scan an area that is common to both sides Add a scan of both centrals in the right lingual segment - Make sure it stitches - Add scans until it succeeds Move to the left lingual segment and add a similar scan there (showing both centrals) - This creates two scans, one in each side, that have a large overlap - If you reach the maximum allowed number of scans, use Delete Unregistered to continue trying - You are responsible for connecting the two sides Modeling will not be able later to fix these problem for you If you use Next, you will not lose any data, but the jaw will not be merged - You will need to add scans later in order to connect the two sides

RTM Scanning Guidelines and Troubleshooting Failed to capture some part of the prep tooth - Add scans in that area, each time trying to capture the tooth from a different viewing i angle - If this is a small area which doesn't include the margin Consider to postpone this, and later use the Eraser Tool It will treat only that area without risking the quality of the margin - If you reach the maximum allowed number of scans, use Delete Unregistered to continue trying

RTM Scanning Guidelines and Troubleshooting Failed to capture the incisal edge of a tooth, where the scanner is touching the tooth. - This is the result of a dirty sleeve. Try to clean it (or replace it) - Try to take a scan of that area from a slightly different viewpoint, such that the scanner doesn't touch the tooth - If it doesn't work, it is also OK to postpone the capture of these areas Sometimes scans from another side (lingual/buccal or left/right) will eventually capture the missing area - Consider using the Eraser Tool for fixing the problem When taking the "filling" scan after marking the eraser, try not to touch the incisal edge of the tooth

RTM Scanning Guidelines and Troubleshooting Merged Model contains unwanted surfaces - These surfaces can be caused by lips or tongue touching the teeth during the scan of that t area - Use the Eraser Tool to fix the problem locally This is the purpose of this tool

Miscellaneous Scan Bodies - Teeth that were defined as Scan Body will be represented in the tooth table of the Rx dialog as 2 rows: The first for the Custom Abutment that will replace the Scan Body The second for the Crown that will be built on top of the Custom Abutment - These Rx fields are all optional. File Attachment - Users can attach a file to the itero case. At most one attachment per case is allowed. - The attachment can be used, for example, for additional Rx info when ordering a Custom Abutment. - The attachment UI is at the bottom left of the Rx dialog: