BIS Readings Of Aspect A 2000 Monitor Are Not Contaminated By Transmitted Oscillations Induced By Jet Ventilation

Similar documents
Kent CD: Awareness during general anesthesia: ASA Closed Claims Database and Anesthesia Awareness Registry. ASA Newsletter 74(2): 14-16, 2010

Manual versus target-controlled infusions of propofol

Age-related requisite concentration of sevoflurane for adequate sedation with combined epidural-general anesthesia

Increasing isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients

BIS Monitoring. ASSESSMENT OF DEPTH OF ANAESTHESIA. Why measure depth of anaesthesia? or how to avoid. awareness in one easy lesson

Original Article. * Received for Publication: September 2, 2006 * Revision Received: December 27, 2006 * Revision Accepted: April 4, 2007

The Effect of Bispectral Index Monitoring on Anesthetic Use and Recovery in Children Anesthetized with Sevoflurane in Nitrous Oxide

Awareness: Where do we stand?

REFERENCE GUIDE USING THE BISPECTRAL INDEX (BIS ) MONITORING SYSTEM FOR CRITICAL CARE

Sedation For Cardiac Procedures A Review of

The correlation of bispectral index with endtidal sevoflurane concentration and haemodynamic parameters in preschoolers

Monitoring for Unconsciousness During General Anaesthesia

Dae-hee Kim 1, Ji-young Yoo 1, Jong-Yeop Kim 1, Soo-hwan Ahn 1, Seongsu Kim 2, and Sang-kee Min 1. Clinical Research Article

Depth of Anesthesia Monitoring in Cardiac Surgery. Adam Dryden MD, FRCPC University of Ottawa Heart Institute

Monitoring Consciousness Using the Bispectral Index During Anesthesia

Mark D. Antoszyk, CRNA, BS Director Anesthesia Services Department of Anesthesiology Carolina s Medical Center Northeast Concord, North Carolina

The bispectral index (BIS) monitor was developed

Pediatric Evaluation of the Bispectral Index (BIS) Monitor and Correlation of BIS with End-tidal Sevoflurane Concentration in Infants and Children

A SAFE AND EFFECTIVE WAY TO OPTIMIZE ANESTHESIA DURING SURGERY

W J A. World Journal of Anesthesiology. Awareness during anesthesia: Current status in Japan. Abstract INTRODUCTION MINIREVIEWS.

Richard A. Beers, M.D. Professor, Anesthesiology SUNY Upstate Medical Univ VA Medical Center Syracuse, NY

Bio Anesthetic Monitor

BIS Brain Monitoring for Critical Care

Closed-Loop Control of General Anesthesia: My Clinical Experience

The Influence of Injection Rate on the Hypnotic Effect of Propofol during Anesthesia: A Randomized Trial

Change in auditory evoked potential index and bispectral index during induction of anesthesia with anesthetic drugs

May 2006 Page 1 / 5 Danmeter A/S

Sedation in Children

Anesthesia depth: EEG or non-eeg derived or both?

PHYSICIAN COMPETENCY FOR ADULT DEEP SEDATION (Ages 14 and older)

Cover Page. The handle holds various files of this Leiden University dissertation.

Hypotension after induction, corrected with 20 mg ephedrine x cc LR EBL 250cc Urine output:

Bispectral index (Bis) guided comparison of control of haemodynamic responses by fentanyl and butorphanol during tracheal intubation in neurosurgical

Effect of remifentanil or esmolol on bispectral index and entropy to tracheal intubation during propofol anesthesia

Unusual elevation in Entropy but not in PSI during general anesthesia: a case report

Spectral entropy measurement of patient responsiveness during propofol and remifentanil. A comparison with the bispectral index {

Abstract. Introduction

New Biomedical Devices And Documentation Of Brain Death

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

BIS Technology Enabling safety and quality improvements in the cardiac operating room

Bird M : Acute Pain Management: A New Area of Liability for Anesthesiologist. ASA Newsletter 71(8), 2007.

Sedation is a dynamic process.

Effects on the Bispectral Index during Elective Caesarean Section: A Comparison of Propofol and Isoflurane

Cricoid pressure: useful or dangerous?

(GCS) Glasgow Coma Scale (BIS)

Effect of landiolol on bispectral index and spectral entropy responses to tracheal intubation during propofol anaesthesia

Emergency Department Guideline. Procedural Sedation and Analgesia Policy for the Registered Nurse

Remifentanil. Addressing the challenges of ambulatory orthopedic procedures 1-3

Awareness during anesthesia--an update.

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

Evaluation of Postoperative Complications Occurring in Patients after Desflurane or Sevoflurane in Outpatient Anaesthesia: A Comparative Study

Nobuko Tachibana Yukitoshi Niiyama Michiaki Yamakage

Postoperative cognitive dysfunction a neverending story

Department of Anesthesiology, Beijing Friendship Hospital, Capital Medical University, Beijing, PR China. Abstract

INTUBATING CONDITIONS AND INJECTION PAIN

AVOIDING THE CRASH 3: RELAX, OPTIMAL POST-AIRWAY MANAGEMENT AVOIDING THE CRASH: OPTIMIZE YOUR PRE, PERI, AND POST AIRWAY MANAGEMENT

The effect of desflurane on rocuronium onset, clinical duration and maintenance requirements

There is a growing interest in using propofol for

awareness during general anaesthesia. implications of explicit intraoperative recall

Survey of the sevoflurane sedation status in one provincial dental clinic center for the disabled

Chapter 25. General Anesthetics

Table showing induction time (seconds) among studied groups Induction time (Seconds)

BRITISH BIOMEDICAL BULLETIN

Optimal sedation and management of anxiety in patients undergoing endobronchial ultrasound (EBUS)

Bispectral index as an indicator of anaesthetic depth during isoflurane anaesthesia in the pig

European Board of Anaesthesiology (EBA) recommendations for minimal monitoring during Anaesthesia and Recovery

HST-151 Clinical Pharmacology in the Operating Room

Detection of brain death onset using the bispectral index in severely comatose patients

Analgesic-Sedatives Drug Dose Onset

Index. Note: Page numbers of article titles are in boldface type.

Sedation in children and young people. Appendix J. Sedation for diagnostic and therapeutic procedures in children and young people

GUIDELINES ON CONSCIOUS SEDATION FOR DENTAL PROCEDURES

Original Article INTRODUCTION. Abstract

Study Of Effects Of Varying Durations Of Pre-Oxygenation. J Khandrani, A Modak, B Pachpande, G Walsinge, A Ghosh

Series 2 dexmedetomidine, tramadol, fentanyl, intellectually disabled patients:

Available online at ORIGINAL RESEARCH. Medicine Science 2018; ( ):

INTUBATION/RSI. PURPOSE: A. To facilitate secure, definitive control of the airway by endotracheal intubation in an expeditious and safe manner

Depth of anaesthesia monitors Bispectral Index (BIS), E-Entropy and Narcotrend-Compact M

Succinycholine: Succinylcholine has no place in pediatric anesthesia. Wads Ames MBBS FRCA

Cardiothoracic Fellow Expectations Division of Cardiac Anesthesia, Beth Israel Deaconess Medical Center

Use of cerebral monitoring during anaesthesia: Effect on recovery profile

Level of sedation evaluation with Cerebral State Index and A-Line Arx in children undergoing diagnostic procedures

Anesthetic Techniques in Endoscopic Sinus and Skull Base Surgery

Monitoring effects of acupressure, needle and laserneedle stimulation by infrared thermography and laser Doppler flowmetry?

Anesthesiology, V 105, No 6, Dec

"Gentlemen, this is no humbug" Dr John Collins Warren, 17 October : Horace Wells 1846: William T. Morton

SedLine Sedation Monitor

Anesthesia Monitoring. D. J. McMahon rev cewood

TECHNISCHE UNIVERSITÄT MÜNCHEN. Medizinische Fakultät. Klinik für Anaesthesiologie, Klinikum rechts der Isar (Vorstand: Prof. Dr.

Increased electroencephalographic gamma activity reveals awakening from isoflurane anaesthesia in rats

Anesthetic Experience of Spinal Anesthesia after Sedation in Un-cooperated Elderly Patients

Guidelines for preventing and managing accidental awareness during general anesthesia

Comparison of Ease of Insertion and Hemodynamic Response to Lma with Propofol and Thiopentone.

Autoregressive Model Order Estimation Criteria for Monitoring Awareness during Anaesthesia

Diagnostics consultation document

Brain Monitoring of Anesthetic Effect

Date 8/95; Rev.12/97; 7/98; 2/99; 5/01, 3/03, 9/03; 5/04; 8/05; 3/07; 10/08; 10/09; 10/10 Manual of Administrative Policy Source Sedation Committee

Time to Lowest BIS after an Intravenous Bolus and an Adaptation of the Time-topeak-effect

COMPARISON OF INTUBATING CONDITIONS OF SUCCINYLCHOLINE WITH THAT OF ROCURONIUM

A randomised comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during mechanical ventilation for general anaesthesia

Transcription:

ISPUB.COM The Internet Journal of Neuromonitoring Volume 4 Number 1 BIS Readings Of Aspect A 2000 Monitor Are Not Contaminated By Transmitted Oscillations Induced By Jet Ventilation G Schwarz, G Mausser, G Litscher, U Ohner, A Schoepfer, G Friedrich Citation G Schwarz, G Mausser, G Litscher, U Ohner, A Schoepfer, G Friedrich. BIS Readings Of Aspect A 2000 Monitor Are Not Contaminated By Transmitted Oscillations Induced By. The Internet Journal of Neuromonitoring. 2004 Volume 4 Number 1. Abstract The tubeless high-frequency jet ventilation during surgery of the upper respiratory tract is usually performed with total intravenous anesthesia (TIVA). Because TIVA is associated with an increased incidence of awareness, the bispectral index (BIS) is considered useful to monitor the depth of anesthesia. However, BIS values can be influenced by physiological, pharmacological and technical factors. Specific technical devices are described to compromise BIS-readings during anasthesia by transmitted oscillations. Jet ventilation causes rhythmic pulsations that are conducted to frontal structures. We studied whether oscillations caused by tubeless jet ventilation affect BIS readings of an Aspect 2000 BIS monitor. Nineteen patients (13 male, 6 female; ASA status 1-3; mean age 46.9 ± 15.7 years; range 21-70) undergoing ear, nose and throat (ENT) procedures were enrolled. TIVA was standardized (propofol 8-10 mg/kg/h; remifentanil 0.2-0.5 µg/kg/min) and paralysis obtained with rocuronium (0.5 mg/kg). BIS was recorded with an Aspect A2000 BIS monitor before induction and during anesthesia (M1 = spontaneous breathing; M2 = superimposed high-frequency jet ventilation, pulsating frequency 600/min; M3 = high-frequency jet ventilation, pulsating frequency 60/min). The median BIS recordings (range of mean BIS values 31-35) during anesthesia did not show significant changes (p < 0.05) during jet ventilation (M2, M3) in comparison to spontaneous breathing (M1). In conclusion, oscillations of tubeless jet ventilation do not appear to contaminate BIS readings obtained during anesthesia in adults. INTRODUCTION The bispectral index (BIS) is an adjunctive method to monitor depth of anesthesia [ 1, 2, 3 ]. However, BIS readings are subject to pharmacologic [ 4, 5, 6, 7, 8, 9, 10 ] and non pharmacologic [ 11, 12, 13, 14, 15, 16 ] influences which can compromise the interpretation of BIS or cause paradoxical readings. Biologic oscillations such as the EMG [ 13 ] and technical oscillations due to equipment [ 16 ] can also influence BIS readings. Oscillations induced by jet ventilation can be conducted to the forehead and are recordable over these structures [ 17 ]. We studied whether such oscillations affect BIS readings obtained with the BIS Aspect A 2000 monitor under total intravenous anesthesia (TIVA). METHODS The protocol was approved by the institutional ethics committee and all patients gave written informed consent. We enrolled 19 patients (13 male, 6 female; ASA status 1-3, mean age 46.9 ± 15.7 years; range 21-70 years) in our study. Biometric data and the indications for ENT surgery of the upper airways are shown in Table 1. All patients received 7.5 mg midazolam PO 1 hour before anesthesia. Induction and maintenance of anesthesia were standardized. Anesthesia was induced intravenously with fentanyl (1.5 µg/kg) and propofol (2-2.5 mg/kg). Paralysis was obtained with rocuronium (0.5 mg/kg) IV. Anesthesia was maintained with propofol (8-10 mg/kg/h IV) and remifentanil (0.2-0.5 µg/kg/min). Jet ventilation and endoscopic surgical procedures (with the micromanipulator guided CO 2 laser, n = 14) were performed with a modified Kleinsasser laryngoscope (n = 18) or a special tracheoscope [ 18 ] (n = 1). Tubeless high-frequency jet ventilation was performed with a commercial jet respirator (BronchotronTM, Percussionaire Air Corp., Sandpoint, ID, USA) at the following settings: superimposed high-frequency jet ventilation (SHFJV) with a respiratory rate of 14/min superimposed with pulsating frequencies of 600/min and high-frequency jet ventilation 1 of 5

(HFJV) with a pulsation frequency of 60/min. Inspiration was set at 50 %, the driving pressure was < 2 mbar, FIO 2 0.4. Figure 1 Table 1: Indications for surgical procedures under jet ventilation (n = 19) ranges of 31-32, 32-33 and 33-35, respectively. All BIS readings during anesthesia differed significantly from those before induction. BIS readings during anesthesia (M1, M2 and M3) did not differ from one another and were not affected by the patterns of jet ventilation (Fig. 1). The EMG proportion was 80 % before induction and 0 % between M1 and M3 (Fig. 2). The median SQI at M2 and M3 was > 90 % and 60 % before induction (Figs. 1, 2). Figure 2 Figure 1: Box plot of bispectral index (BIS) before (A) and during (M1 - M3) jet ventilation in 19 patients (spontaneous breathing (M1); jet ventilation with pulsating frequencies of 600/min (M2) and 60/min (M3)). The ends of the boxes define the 25th and 75th percentiles, with a line at the median and error bars defining the 10th and 90th percentiles. BIS was recorded with an Aspect A 2000 monitor (Aspect Medical Systems, Natick, MA, USA). The monitor recorded the proportion of EMG inputs and the signal quality index (SQI). The surface electrodes (BIS, Aspect Medical Systems, Natick, MA, USA) were placed frontally according to the manufacturer's guidelines. The impedance was < 5 kohm. The BIS trend depiction was digitally photodocumented for post hoc plausibility analysis. Standard monitoring included ECG, noninvasive blood pressure, peripheral oxygen saturation (SaO 2 ) and skin temperature (Solar 800, Marquette Medical Systems, Milwaukee, USA). Blood gasses were measured at the measuring points as described below. BIS readings were obtained immediately before induction of anesthesia (A) and three phases during anesthesia (M1, M2, M3), with the ventilation settings described above. M1 was defined as 1.5, 2.5 und 4.0 min after the BIS decreased to < 50. M2 and M3 were measured after changing of the ventilation settings, including 1-min. equilibration intervals at 1.5, 2.5 und 4.0 min. Figure 3 Figure 2: Electromyographic recordings (EMG) before (A) and during (M1 - M3) jet ventilation. Abbreviations explained in Fig. 1. STATISTICS The values obtained before anesthesia and at all 3 measuring points of the 3 measuring phases were tested with one way repeated measures analysis of variance using SigmaStat software (Jandel Scientific Corp., Erkrath, Germany). As post hoc analysis Dunnett s method was used. P values < 0.05 were considered statistically significant. RESULTS The median BIS just before induction of anesthesia was 95. Median BIS readings at M1, M2 and M3 were within the SaO 2 exceeded 90 % in all patients at all measuring points. 2 of 5

Body surface temperature ranged from 35.0 to 35.7 C. NIBP and pco 2 showed no associations with BIS readings. DISCUSSION Tubeless high-frequency jet ventilation increases diagnostic and therapeutic options during endoscopic surgery of the respiratory tract by providing sufficient ventilation without restricting the surgical field [ 18, 19, 20 ]. TIVA is preferred for procedures done under jet ventilation ( 18 ] but is associated with a higher incidence of awareness [ 21 ]. Accordingly electrophysiologic monitoring of the depth of anesthesia appears appropriate. But monitoring makes sense only if the recorded data are plausible and unaffected by the ventilation technique used, especially as increases and decreases of BIS are not always signs of inadequate anesthesia, and because BIS does not accurately indicate the depth of anesthesia in all patients ( 22, 23, 24 ]. The A 2000 Bispectral IndexTM (BISTM) monitoring system we used in this study is the successor of the Aspect A 1000 (Aspect Medical Systems, Natick, MA, USA). Additional features of the Aspect A 2000 are bar readings of the EMG and signal quality, which help to interpret BIS values. Current surgical navigation systems in otorhinolaryngology can create electromagnetic fields that cause changes in brain electric activity and inadequate BIS readings [ 15 ]. A further category of biomedical instruments affecting BIS readings during surgery are equipments generating mechanical oscillations. Devices for forced-air warming of the head have been reported to interfere with BIS readings [ 14 ]. Guignard and Chauvin [ 22 ] speculated that air circulation can generate vibration of the head wires. Hemmerling and Migneault [ 16 ] described an endoscopic shaver that induced falsely increased BIS values and hypothesized that shaverinduced oscillations at the shoulder joint are transmitted via bone to forehead and temporal area. In a pilot study we found transmission of oscillations from laryngeal and buccal localizations to the frontal region of the head [ 17 ]. These oscillations (Fig 3 a,b) were synchronous to the pulsation frequencies (60/min, 600/min) of jet ventilation and were probably caused by rhythmic pressure transmission of the jet ventilation from the pharyngolaryngeal region to the skull. However, our BIS readings presented here showed no significant changes at any point during anesthesia, neither during spontaneous breathing nor during SHFJV with a pulsating frequency of 600/min or HFJV with a pulsating frequency of 60/min. Data quality was adequate with absent artificial high frequency (EMG) contaminations and with a predominantly high signal quality index. Figure 4 Figure 3: Oscillations of jet ventilation (digitally fotodocumentation) at pulsation frequencies of 600/min (a) and 60/min (b) recorded with a piezzo-electric sensor at the forehead (BIS Monitor Aspect A 1000). The mean BIS readings in this study were slightly below the recommended lower target range of 40 [ 2, 3 ] because anesthesia for surgery of laryngeal and tracheal structures was kept deeply enough to suppress autonomic responses to surgery-induced stimuli. Whether the deeper stages of anesthesia could have an influence on our results cannot be verified by the study design. In summary, physically transmitted oscillations to the forehead generated by the pulsations of tubeless jet ventilation do not appear to compromise the BIS readings of Aspect A 2000. CORRESPONDENCE TO Gerhard Schwarz, MD Department of Anesthesiology and Intensive Care Medicine Medical University of Graz Auenbruggerplatz 29 A-8036 Graz Austria Tel: ++43/316/385-83911 Fax: ++43/316/385-3491 gerhard.schwarz@meduni-graz.at References 1. Rampil IJ. A primer for EEG signal processing in anesthesia. Anesthesiology 1998; 89: 980-1002. 2. Sebel PS, Lang E, Rampil IJ, et al. A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect. Anesth Analg 1997; 84: 891-899. 3. Liu J, Singh H, White PF. Electroencephalographic bispectral index correlates with intraoperative recall and depth of propofol - induced sedation. Anesth Analg 1997; 84: 185-189. 4. Hirota K, Kubota T, Ishihara H, Matsuki A. The effects of nitrous oxide and ketamine on bispectral index and 95% spectral edge frequency during propofol-fentanyl anesthesia. Eur J Anaesthesiol 1999; 16: 779-783. 5. Puri GD. Paradoxical changes in bispectral index during nitrous oxide administration. Br J Anaesth 2001; 86: 141-142. 6. Detsch O, Schneider G, Kochs E, et al. Increasing 3 of 5

isoflurane concentration may cause paradoxical increases in the EEG bispectral index in surgical patients. Br J Anaesth 2000; 84: 33-37. 7. Goto T, Nakata Y, Saito H, et al. Bispectral analysis of the electroencephalogram does not predict responsiveness to verbal command in patients emerging from xenon anesthesia. Br J Anaesth 2000; 85: 359-363. 8. Mychaskiw G, Horowitz M, Sachdev V, Heath BJ. Explicit intraoperative recall at a Bispectral Index of 47. Anesth Analg 2000; 92: 808-809. 9. Kurehara K, Horiuch T, Takahashi M, et al. A case of awareness during propofol anesthesia using bispectral index as an indicator of hypnotic effect. Masui 2001; 50: 886-889. 10. Schneider G, Wagner K, Reeker W, et al. Bispectral Index (BIS) may not predict awareness reaction to intubation in surgical patients. J Neurosurg Anesthesiol 2002; 14: 7-11. 11. Mychaskiw G, Heath BJ, Eichhorn JH. Falsely elevated bispectral index during deep hypothermic circulatory arrest. Br J Anaesth 2000; 85: 798-800. 12. Hall JD, Lockwood GG. Bispectral index: comparison of two montages. Br J Anaesth 1998; 80: 342-344. 13. Bruhn J, Bouillon TW, Shafer SL. Electromyographic activity falsely elevates the bispectral index. Anesthesiology 2000; 92: 1485-1487. 14. Hemmerling TM, Fortier JD. Falsely increased BIS values in a series of patients undergoing cardiac surgery using forced-air-warming therapy of the head. Anesth Analg 2002; 95: 322-323. 15. Hemmerling TH, Desrosiers M. Interference of electromagnetic operating systems in otorhinolaryngology surgery with bispectral index monitoring. Anesth Analg 2003; 96: 1698-1699. 16. Hemmerling TH, Migneault B. Falsely increased bispectral index during endoscopic shoulder surgery attributed to interferences with the endoscopic shaver device. Anesth Analg 2002; 95: 1678-1679. 17. Schwarz G, Mausser G, Litscher G, Friedrich G. Physical transmission of jet-ventilation oscillations to frontal registration positions for process-calculated EEGparameters: A clinical-experimental pilot study. Internet J Neuromonitoring 2004; http://www.ispub.com/ostia/index.php?xmlfilepath=journals /ijnm/vol3n2/jet.xml. 18. Friedrich G, Mausser G, Nemeth E. Wertigkeit und Einsatzmöglichkeiten der superponierten Hochfrequenz-Jet- Ventilation (SHFJV) in der endoskopischen Chirurgie der Atemwege. HNO 2002; 50: 719-726. 19. Ihra G, Gockner G, Kashanipour A, Aloy A. Highfrequency jet ventilation in European and North American institutions: developments and clinical practice. Eur J Anaesth 2000; 17: 418-430 20. Bacher A, Pichler K, Aloy A. Supraglottic combined frequency jet ventilation versus subglottic monofrequent jet ventilation in patients undergoing microlaryngeal surgery. Anesth Analg 2000; 90: 460. 21. Domino KB, Posner KL, Caplan RA, Cheney FW. Awareness during anesthesia. A closed claims analysis. Anesthesiology 1990; 90: 1053-1061. 22. Guignard B, Chauvin M. Bispectral index increases and decreases are not always signs of inadequate anesthesia. Anesthesiology 2000; 92: 903. 23. Litscher G, Schwarz G. EEG/EP - Monitoring: Technische und biologische Fehlerquellen. In: Schwarz G, Litscher G, eds. Neuromonitoring in Anasthesie und Intensivmedizin. Wiesbaden: Wiss. Verl.-Abt. Abbott, 1998: 171-190. 24. Litscher G, Schwarz G. Noninvasive bioelectrical neuromonitoring in anesthesia and critical care. Eur J Anesth 2002; 19: 543-549. 4 of 5

Author Information Gerhard Schwarz, M.D. Gerlinde Mausser, M.D. Gerhard Litscher, Ph.D., MDSc. Ursula Ohner, M.D. Andreas Schoepfer, M.D. Gerhard Friedrich, M.D. Department of Otorhinolaryngology, Medical University of Graz 5 of 5