Ribbon Splitting Tool (RST-000)

Similar documents
Fibrlok II 2529 Universal Optical Fiber Splice

Instructions. Fibrlok II Optical Fiber Splicing System. Issue 1, June 1992

Fibrlok II 2529 Universal Optical Fiber Splice

Instructions. Fibrlok Optical Fiber Splicing System. Issue 6, August 1991

Geschrieben von: Yadira Jones

Pollen Slide Mounting Protocol

ISO IVD 13485: : :2015

HOW TO USE YOUR INSTANYL MULTI-DOSE NASAL SPRAY

Mass Fusion Splicing of Optical Fiber Ribbon Cables

ReSound Vea Custom In-the-canal (ITC) and In-the-ear (ITE)

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

Medescan Nebuliser Med - S600A Instructions Manual

Dear HighQ Check System Owner :

Control D. User Manual. Blood Glucose Monitor. Subscribe on MYCONTROL.life HAIDEN

Nucleus CP810 Sound Processor User Guide

Instructions for Use HEMLIBRA (hem-lee-bruh) (emicizumab-kxwh) injection, for subcutaneous use

Do not re use needles. If you do you might not get your dose (underdosing) or get too much (overdosing) as the needle could block.

HumaPen SAVVIO INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

OPTICAL FIBER SPLICING. Courtesy from Significant Technologies Sdn Bhd

How To Get The Most Out of Your StarSet Headset

Gentleman s Brand. Ambassador kit USER GUIDE

For use only with INSTRUCTIONS FOR USE

Big. Shots. Big. Sh ts. The sound choice in Hearing Protection. Be Ear-Responsible

TWIST STEPPER NO. 045

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx Video Portable OtoScope System

Blood Glucose Monitoring System. Owner's Booklet. Instructions for Use

INSTRUCTIONS FOR USE TYMLOS (tim lows ) (abaloparatide) injection, for subcutaneous use

Increase Strength, Flexibility, Range of Motion and Endurance. NeckXsystems Guidelines & Exercise. NeckX is Patent Pending

Custom instruments. Insio primax User Guide. Hearing Systems

Instructions for Use. Welcome!

TABLE OF CONTENTS. 2.0 USING MANAGER PREFERENCE 2.1 Using manager preference mode 2.2 Selecting US or metric 2.3 Using CSafe

ULTR A SERIES G7-S75

Seven Simple Steps to Start. Your Dexcom G4 PLATINUM System

Inhaler technique reminder cards

Big. Shots. Big. Sh ts. mini. The sound choice in Hearing Protection. Be Ear-Responsible

Point of Care Testing. Bedside Glucose Meter

BLINDED MODE USERS GUIDE SUPPLEMENT

BRS GM100 Glucose Monitoring System. User Instruction Manual Ver. 3.5

Single Use Curlew TM Multiple Biopsy Forceps

EVER Pharma D-mine Pen Pen injector for Apomorphine 10 mg/ml

Pure 312 Nx, Pure 13 Nx

Instructions for Use. HUMALOG KwikPen. insulin lispro injection (rdna origin) 100 units/ml, 3 ml pen

TWISTING STAIR STEPPER WITH BANDS NO. 068 USER MANUAL

HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE

Home Health Foundation, Inc. To create more permanent IV access for patients undergoing long term IV therapy.

Mac mini (PowerPC) Storage Interface Board Replacement

Precision Xtra Training

PATIENT INSTRUCTIONS FOR USE SINGLE- DOSE PREFILLED SYRINGE

STEP-BY-STEP GUIDE TO SELF-INFUSION. Subcutaneous Administration of GAMMAGARD LIQUID

Mini-Mist. Owner s Manual. portable nebulizer. PMM241 Rev.3 12/10

Blood Glucose Monitoring System. Link the Effects of Food to Glucose Results. Owner s Booklet

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray

ULTR A SERIES G7-S13

SelectTech 3.1 Bench Assembly / Owner s Manual

OWNER S MANUAL. Quick Insertion Guide: INSERT EARTIP into ear canal and rotate earpiece backwards & into position CHECK FOR SEAL

Motorised Treadmill Model No: JI1625

IMPACT Pro R Instructions and guidance

SelectTech 4.1 Bench Assembly / Owner s Manual

SMOKELESS TOBACCO SPRING LOAD TRAYS

Instructions for Use. BASAGLAR KwikPen. insulin glargine injection (100 units/ml, 3 ml pen)

TJF-160F/VF Cleaning and Disinfection Checklist

A-dec 372L or 572L Dental Light on an A-dec Performer Dental Chair INSTALLATION GUIDE

PEMF Users Manual. IMPORTANT: Read Me Before Powering On Your Machine!

Product Specifications and Usage Information P4405, P4410, & P4420 Genesys 30 Dosimeter Holder System

COYOTE Flip Splice Trays for High Density Splice Applications

Lat Pull Down Owner's Manual

Items in the package:

Cap Clip Rubber Seal Plunger Pen Body Dose Window

GEX Recommended Procedure Eff. Date: 09/21/10 Rev.: D Pg. 1 of 7

Drainage Frequency: PATIENT GUIDE. Dressing Frequency: Every Drainage Weekly Drainage. Physician Contact Information. Dr. Phone:

IMPORTANT INFORMATION - PLEASE READ. Table of Contents. Introduction. General Information

Instructions for Use Neulasta (nu-las-tah) (pegfilgrastim) Injection, for subcutaneous use Single-Dose Prefilled Syringe. Plunger rod Used plunger rod

Step-by-Step Instructions For OraQuick HCV Rapid Antibody Test

ULTR A SERIES G7-S23

PRIMA. Blood Glucose Monitoring System. Owner s Manual

OWNER S MANUAL. BODYCRAFT 7699 Green Meadows Dr., Lewis Center, Ohio Tel:

HDM 330/500 Operating instructions Mode d emploi Manual de instrucciones Manual de instruções

SureFlow. Oxygen Flow Station PROVIDER TECHNICAL MANUAL

Tips for Training New Customers

E L E C T R O N I C VA P O R I Z E R S. User Manual

Geschrieben von: Phillip Takahashi

ULTR A SERIES G7-S51

HUMULIN 70/30 KwikPen

DO NOT TRANSFER TO A SYRINGE SEVERE OVERDOSE CAN RESULT

Inspection Window. Syringe Body

Successful Splicing Made Easy

Thank you for purchasing the AB COASTER. Our customer service staff is ready to help and to answer any questions.

VOICE. Blood Glucose Monitoring System. Owner s Manual

For more information visit or contact hearx:

Jadelle Contraceptive Implants up to 5 years Insertion and Removal

MX SELECT OWNER S MANUAL. Revolutionising Strength Training REGISTER YOUR PRODUCT AT MXSelect. MX_Select.

For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges.

TH Premium RIC LI 19. Guide for Hearing Care Professionals

Power-Pak 445 Adjustable Dumbbell System

INSTRUCTIONS FOR USE. Norditropin NordiFlex Somatropin (rdna origin) injection 30 mg/3 ml Prefilled Pen

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

V22 V22. USER INSTRUCTIONS Version. 01 STRONGARM ERGOSKELETON. Lift Assist Device

Transcription:

Ribbon Splitting Tool (RST-000) P/N 004-098 Issue 12 related literature Search www.corning.com/opcomm. Click on Resources. Slider button Latch 1. General Figure 1 1.1 This procedure describes how to divide fiber optic ribbons with the Corning Optical Commuications Ribbon Splitting Tool (p/n RST-000) (Figure 1). Both mid-span and end-of-ribbon applications are covered in this procedure. 1.2 The RST-000 can split a ribbon up to a length of 0.5 meter (20 in) before the tool needs cleaning. For longer lengths, the splitting process is resumed after clean ing the ribbon matrix material from the tool s channels. 1.3 The RST-000 has nine positions which accommo date ribbons from 4 to 36 fibers, as indicated by the sum of the stacked numbers on the tool (e.g., 2/2 = 4-f, 12/24 = 36-f). A high-precision slider mechanism splits the ribbon matrix to create two smaller ribbons. The tool is bi-direc tional (i.e., ribbons can be pulled though its channels in either direction). 2. Precautions CAUTION: Recommend the use of safety glasses (spectacles) conforming to ANSI Z87, for eye protection from accidental injury when handling chemicals, cables or fiber. Pieces of glass fiber are very sharp and have the potential to damage the eye. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending, and crushing forces. Consult the cable specification sheet for the cable you are installing. Do not bend the cable more sharply than the minimum recommended bend radius. Do not apply more pulling force to the cable than specified. Do not crush the cable or allow it to kink. Doing so may cause damage that can alter the transmission characteristics of the cable; the cable may have to be replaced. Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 1 of 6

CAUTION: The RST-000 is a high-precision tool. Store the tool in the box provided, and use care to avoid dropping the tool. Failure to do so may result in misalign ment which must be factory-corrected. Do not attempt to adjust a damaged tool yourself. WARNING: Isopropyl alcohol is flammable with a flashpoint at 54 F. It can cause irritation to eyes on contact. In case of contact, flush eyes with water for at least 15 minutes. Inhalation of vapors irritates the respiratory tract. Exposure to high concentrations has a narcotic effect, producing symptoms of dizziness, drowsiness, headache, staggering, unconsciousness, and possibly death. 3. Tools and Materials The following tools and materials are required to complete this procedure: Cleaning brush (provided with tool) Aerosol duster or source of clean, filtered air Permanent marker pen Tape measure Vinyl tape Spatula If the tool has not been properly maintained, you may need the following items: Ultrasonic cleaner with approved cleaning solution A piece of card stock (e.g., a business card or index card) Lint free tissues or cloth Isopropyl alcohol 4. General Information on Using the Ribbon Splitting Tool 4.1 The Ribbon splitting tool produces nine configura tions of ribbons (Table 1): Original Ribbon Fiber Count Ribbon Configurations after splitting 36 12 /24 24 12 / 12 12 6 / 6 4 / 8 2 / 10 8 4 / 4 6 / 2 6 2 / 4 4 2 / 2 Table 1: Ribbon Configurations 4.2 It is critical to be aware of the orientation of the ribbon and identity of the fibers being split into new, smaller ribbons. For example: If you wish to separate fibers 1 and 2 (the blue and orange fibers) in a 6-fiber ribbon from the other four fibers (# s 3-6, green, brown, slate, white), the original 6-fiber ribbon MUST be placed in the 2/4 slot of the tool with its white #6 fiber at the bottom of the channel (Figure 2). Improper loading of the tool would result in fibers 6 and 5 in the 2-fiber ribbon and fibers 1 through 4 in the other. Top half of tool Bottom half of tool 6 fiber ribbon Figure 2 4.3 For end-of-ribbon uses of the tool, the ribbons may either be fed into the appropriate channel with the lid closed or placed into the channel with the lid open. The length of the ribbon to be split will determine which method is more convenient. For mid-span applications, the lid must always be opened to accept the ribbon. Fiber # 1 (blue) Fiber # 2 (orange) Fiber # 3 (green) Fiber # 6 (white) "new" 2 and 4-fiber ribbons Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 2 of 6

CAUTION: Failure to clean the channels before each use of the tool may result in the wrong fibers being separated. Refer to Section 9, Maintenance, for cleaning instructions. 5. Cable and Ribbon Preparation Step 1: IMPORTANT: Remove the sheath and access the ribbons according to the appropriate procedure for the cable you are installing. For mid-span accessing, it is critical that you refer to your system plan to determine access length, the proper end of the accessed ribbon/fibers to be cut, etc. Make sure that the original ribbon is clean and dry before placing it in the tool to prevent build up of matrix debris, filling compound remover, and dirt in the tool s channels. Determine the configuration (both fiber count and fiber position) and mark the required length of the new ribbons with a permanent marker (Figure 3). NOTE: Figure 3 If your application requires a split length of more than 0.5 meter (20 in), use a different color marker to indicate the half meter point(s) where the tool will need to be removed and cleaned (Figure 4). End-of-Ribbon Applications: Split length of more than 0.5 meter Desired length mark third split 0.5 meter mark Clean tool second split 0.5 meter mark Clean tool first split Ribbon end Mid-span Applications: Split length of more than one meter End mark En Proceed to the section appropriate for your use 6. Splitting into 12-Fiber Ribbons 7. End-of-Ribbon Applications or 8. Mid-Span Applications. center Figure 4 Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 3 of 6

6. Splitting into 12-Fiber Ribbons Step 1: Open and clean the tool as described in Section 10, Maintenance To load an open tool, position the ribbon approximately 2-in from its end in the appropriate channel, either the 12/12 split or the 12/24 split (Figure 5). 2 in Figure 5 Push in and hold the slider button on the end of the tool and pull the ribbon so that the last 2 inches are split using the tool (Figure 6). Step 4: Press the latch release to open the lid and clean the tool as needed with the brush provided as described in Section 10, Maintenance Verify that the ribbons have split correctly between the blue and aqua fibers. Step 6: Take one ribbon in each hand, pulling one upwards and one downwards (Figure 7). Switch pulling directions every 12 inches, alternating back and forth. Figure 6 TPA-6279 Figure 7 Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 4 of 6

7. End-of-Ribbon Access for all other Applications Step 1: Open and clean the tool as described in Section 10, Maintenance To load an open tool, position the ribbon in the appropriate channel at its marked separation point or a 0.5-meter mark, whichever is closest to the end of the rib bon (Figure 8). Close the lid. Skip to step 4. To feed the ribbon into a closed tool: a. Hold the ribbon 2.5 cm (1 in) from its end (Figure 9). Figure 8 Figure 9 b. Insert the ribbon into the proper channel. Push the end of the ribbon through the tool (Figure 10). c. Pull the ribbon through the tool until you reach the marked separation length or the first mark on the ribbon, whichever is closest to the end of the ribbon (Figure 11). Step 4: Step 6: Step 8: Step 9: Push in and hold the slider button on the end of the tool as you smoothly pull the 0.5-meter length of ribbon through the channel to the end of the ribbon (Figure 12). Press the latch release to open the lid. Clean the tool with the brush provided with the tool as described in Section 10, Maintenance If you still have an additional length of ribbon to split, open the tool and insert the original ribbon in the proper channel of the tool at the marked separation length or next 0.5-meter mark. Figure 10 Figure 11 Push in and hold the slider button on the end of the tool as you smoothly pull the next 0.5-meter length (or remain ing required length) of ribbon through the channel to the split made in step 4. Repeat steps 5 and 6 as necessary to complete the end-of-ribbon splitting. Prepare the ribbons for splicing or termination according to your system plan. Figure 12 Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 5 of 6

8. Mid-Span Applications Step 1: Open and clean the tool as described in Section 10, Maintenance Position the ribbon in the appropriate channel at one of its marked end points (see Figure 8). Close the lid. Push in and hold the slider button on the end of the tool as you move the tool along the ribbon from the end mark to either the other end mark (splits less than 0.5 meter), or to the 0.5-meter mark, as appropriate (Figure 13). Figure 13 Step 4: Press the latch release to open the lid (Figure 14). Clean the tool with the brush provided with the tool as described in Section 10, Maintenance If you still have an additional length of ribbon to split, open the tool and insert the original ribbon in cor rect channel of the tool at the other end mark or next 0.5 -meter mark, as appropriate. Figure 14 Step 6: Step 8: Push in and hold the slider button on the end of the tool as you smoothly move the tool from this mark to the split made in step 3 (Figure 15). Repeat steps 4 and 5 as necessary to complete the mid-span ribbon splitting. Prepare the ribbons for splicing or termination according to your system plan. 9. Accessing Individual Fibers Figure 15 For end-of-ribbon applications, determine the length of fiber needed and identify the appropriate fibers in the ribbon that need to be broken out into individual fibers as specified in the system plan. For mid-span applications, skip to Mid-Span Applications. End-of-Ribbon Applications Step 1: First split Measure the required distance on the ribbon with a tape measure and mark this point with a permanent mark ing pen (Figure 16). Wrap the ribbon at the mark with vinyl tape to prevent excessive breakout of the ribbon (Figure 17). Tape 2 1 9 2 0 Figure 16 Figure 17 Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 6 of 6

For example: Use the RST-000 as described in Section 7, End-of-Ribbon Access for all other Applications, for the first split to start isolating the fibers to be accessed individually. If you wish to access fibers 1 through 4 (the blue, orange, green, and brown fibers) in a 12-fiber ribbon, place the ribbon in the 4/8 slot of the tool with the blue fiber at the top of the tool. The result is a 4-fiber ribbon and an 8-fiber ribbon. Step 4: At the free end of the ribbon with the fibers to be accessed individually, use scissors to cut the end at a 45-degree angle (Figure 18). Using a spatula or finger nail, start to separate the longest fiber away from the rest of the ribbon (Figure 19). 45 Figure 18 Figure 19 Step 6: Pull this fiber until it is separated down to the wrap made in step 2 (Figure 20). NOTE: Step 8: Step 9: NOTE: Figure 20 Figure 21 Repeat steps 5 and 6 for the remaining fibers in the ribbon. If a fiber breaks near its free end while trying to separate it out, cut this fiber and the remaining unseparated fibers in the ribbon at a new 45-degree angle. Restart the separation process with the longest unseparated fiber. Remove the ribbon matrix from the separated fibers by wiping the fibers with a lint-free tissue or cloth soaked in isopropyl alcohol. Wipe the fibers individually until all of the matrix material has been removed (Figure 21). Verify that all the matrix material has been removed by running your fingers along the fibers. The fibers should feel and appear very uniform in dimension and texture. Some small amount of fiber color may have been removed this is normal. Step 10: Wipe the fibers with a clean and dry lint-free tissue or cloth. The individual fibers are now ready for splicing or fan-out procedures. Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 7 of 9

Mid-Span Applications Step 1: Step 4: For example: For mid-span applications, identify the ribbon to be accessed, and identify the appropriate fibers in that ribbon that need to be broken out into individual fibers as speci fied in the system plan. Move the loop of ribbon to a work surface, if possible. Use a tape measure and permanent marker to mark the desired breakout length on the ribbon. Wrap the ribbon at the marks with vinyl tape to prevent excessive breakout of the ribbon (Figure 22). Use the RST-000 as described in Section 7, End-of-Ribbon Access for all other Applications, for the first split to start isolating the fibers to be accessed individually. If you wish to access fibers 1 through 4 (the blue, orange, green, and brown fibers) in a 12-fiber ribbon, place the ribbon in the 4/8 slot of the tool with the blue fiber at the top of the tool. The result is a 4-fiber ribbon and an 8-fiber ribbon. Step 6: Step 8: Step 9: Splice closure (or splice tray) Tape and marks Center of ribbon slack loop The RST-000 can be used to initiate additional splits to help gain access to individual fibers. The RST- 000 is used in the same manner as step 4, except that the tool is only used for the first 2.5 cm (1 in) of the split. The remainder of the split is completed by pulling the smaller ribbons by hand to the tape mark. These addition al splits will result in two or more 2-fiber ribbons. In the example above, the RST-000 can be used to initiate the split of the 4-fiber ribbon into two 2-fiber ribbons. Grasping the 2-fiber ribbon with your thumb and forefinger of each hands about 7.5 cm (3 in) apart, gently rotate the ribbon while simulating the motion of bicycle pedals with your hands. Repeat this motion until the fibers begin to fall out of the matrix material (Figure 23). Repeat step 6 as necessary until all required fibers from the ribbon have been separated from the matrix material. Figure 22 Route the remaining fibers and/or ribbon(s) from step 5, which will not be accessed, into a splice tray. Remove the ribbon matrix from the separated fibers by wiping the fibers with a lint-free tissue or cloth soaked in isopropyl alcohol. Wipe the fibers until all of the matrix material has been removed (Figure 24). Figure 23 Figure 24 Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 8 of 9

Step 10: Verify that all the matrix material has been removed by running your fingers along the fibers. The fibers should feel and appear very uniform in dimension and texture. NOTE: Step 11: Some small amount of fiber color may have been removed this is normal. Wipe the fibers to be accessed with a clean and dry lint-free tissue or cloth. The individual fibers are now ready for splicing. 10. Maintenance Step 1: Press the latch release to open the lid. Swing the lid to its open position. To clean the tool: a. Use the brush provided with the tool to remove dust or fragments of ribbon matrix from the top and bottom halves of the tool (Figure 25)). b. Blow the channels out with compressed air (Figure 26). Figure 25 Figure 26 If the tool has become adversely affected by built-up matrix debris, filling compound remover, and dirt, use an ultrasonic cleaner with approved cleaning solution to thoroughly clean the tool. For field cleaning, use a piece of card stock (e.g., a busi ness card or index card), soaked in alcohol to clean the channels (Figure 27). For service or repair of the RST-000, contact your Corning Optical Commuications customer care representative. ALCO H O L Figure 27 Corning Optical Communications LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-828-901-5000 www.corning.com/opcomm Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. 1998, 2018 Corning Optical Communications. All rights reserved. Standard Recommended Procedure 004-098 Issue 12 October 2018 Page 9 of 9