ComparisonofUlnar-ShorteningOsteotomyWitha NewTrimedDynamicCompressionSystemVersusthe SynthesDynamicCompressionSystem:ClinicalStudy

Similar documents
Step-Cut Distal Ulnar Shortening Osteotomy

Ulna Shortening Osteotomy Using a Compression Device

Interesting Case Series. Ulnolunate Impaction Syndrome

Triangular Fibrocartilage Complex Repair. The triangular fibrocartilage complex (TFCC) is one of the main stabilizers of the

Index. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)

The pre-drilled hole method in the freehand technique for ulnar shortening osteotomy : a case series study

A Patient s Guide to Adult Distal Radius (Wrist) Fractures

Chapter 12 Distal Ulnar Resection

Ulnar Shortening Osteotomy for Ulnar Impaction Syndrome

University of Groningen. Fracture of the distal radius Oskam, Jacob

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred.

Osteotomy System. Surgical Technique

Chapter 13. Arthroscopic Lunotriquetral Arthrodesis and Head of the Hamate Resection. Introduction. Operative Technique (Fontes) Midcarpal Exploration

CASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

Technique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.

Total distal radioulnar joint replacement for symptomatic joint instability or arthritis

Ulnar Impaction. Douglas M. Sammer, MD a, Marco Rizzo, MD b, * hand.theclinics.com KEYWORDS BIOMECHANICS

Surgical Technique Carpal Fusion

Arthroscopy: today the gold-standard in wrist joint surgery. Ivan Tami. Swiss Medical Network. Musculoskeletal Conference, Bern.

8 Recovering From HAND FRACTURE SURGERY

Chapter 19. Arthroscopic Bone Grafting for Scaphoid Nonunion. Introduction. Operative Technique. Radiocarpal and Midcarpal Exploration

E-CENTRIX. Ulnar Head Replacement SURGICAL TECHNIQUE

Forearm Fracture Solutions. Product Overview

Successful Bone Healing of Nonunion After Ulnar Shortening Osteotomy for Smokers Treated With Teriparatide

Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach

Wrist Arthritis & Partial Wrist Fusion

RAYHACK Kienbock Radial Shortening System

6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]

SPORTS INJURIES IN HAND

Carpal rows injuries!

Long-term Outcomes of Ulnar Shortening Osteotomy for Idiopathic Ulnar Impaction Syndrome: At Least 5-Years Follow-up

The Forearm, Wrist, Hand and Fingers. Contusion Injuries to the Forearm. Forearm Fractures 12/11/2017. Oak Ridge High School Conroe, Texas

A Patient s Guide to Triangular Fibrocartilage Complex (TFCC) Injuries

A Patient s Guide to Adult Forearm Fractures

Case Report Bone Resection for Isolated Ulnar Head Fracture

Visualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique

Integra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE

LCP Ulna Osteotomy System 2.7. Low profile angular stable fixation for ulna shortening osteotomies.

2.4 mm Variable Angle LCP Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

TFCC Tears and Repair. Jeffrey Yao, M.D. Associate Professor Department of Orthopaedic Surgery Stanford University Medical Center

Complications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago

Hand Fracture System with Small Bone External Fixation System. Product Overview

Union Surgical. T-Pin. Fixation System for Distal Radius & Distal Ulna Fractures. Surgical Technique

Modular Ulnar Head surgical technique. Transforming Extremities

The Wrist Fusion Set. Stainless Steel and Titanium TECHNIQUE GUIDE. Instruments and implants approved by the AO Foundation

Outcome of Kienböck s Disease 22 Years after Distal Radius Shortening Osteotomy

FOOSH It sounded like a fun thing at the time!

Interesting Case Series. Perilunate Dislocation

Chapter 4: Forearm 4.3 Forearm shaft fractures, transverse (12-D/4)

Hand and wrist emergencies

TRIQUETRUM FRACTURE. The triquetrum bone is one of the small bones that make up the carpus.

Title. Author(s)Iwasaki, Norimasa; Minami, Akio. CitationThe Journal of Hand Surgery, 34(7): Issue Date Doc URL.

A Patient s Guide to Adult Olecranon (Elbow) Fractures

An Update of Upper Limb Conditions

Jacqueline C. Vanderzanden, Brian D. Adams & Justin J. Guan

Cover Page. The handle holds various files of this Leiden University dissertation.

Orthopaedic Surgery Upper Extremity

MANAGEMENT OF INTRAARTICULAR FRACTURES OF ELBOW JOINT. By Dr B. Anudeep M. S. orthopaedics Final yr pg

ORIGINAL PAPER. Department of Hand Surgery, Nagoya University School of Medicine ABSTRACT

University of Groningen. Fracture of the distal radius Oskam, Jacob

JMSCR Vol 05 Issue 04 Page April 2017

Comparison between Distractor Application on Both Radial & Ulnar Side and Radial Side Only for Fracture Distal Radius with Ulnar Styloid Fracture

Distal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)

FOOSH It sounded like a fun thing at the time!

A Patient s Guide to Adult Radial Head (Elbow) Fractures

D-RAD SMART PACK Plating System. A series of case studies

Rehabilitation after Total Elbow Arthroplasty

Post-Traumatic Malunion of the Proximal Phalanx of the Finger. Medium- Term Results in 24 Cases Treated by In Situ Osteotomy

Union rate: Union: Stable 94% All fracture 90% Union after surgery for nonunion with surgery 80% OA in healed scaphoid: 9%

The Journal of the Korean Society of Fractures Vol.13, No.4, October, 2000

Ulna-shortening osteotomy : subjective appreciation and long-term functional outcome

Zimmer Small Fragment Universal Locking System. Surgical Technique

Technique Guide. VA-Locking Intercarpal Fusion System. Variable angle locking technology for mediocarpal partial arthrodesis.

Fractures and dislocations around elbow in adult

Client centered approach to distal radius fracture management. Jared Rasmussen OTR

Acu-Loc Wrist Spanning Plate System. Surgical Technique

University of Groningen. Fracture of the distal radius Oskam, Jacob

Index. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /

Introduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.

Distal radius fractures are

Factors Predicting Late Collapse of Distal Radius Fractures

CLINICAL PRESENTATION AND RADIOLOGY QUIZ QUESTION

Acute Wrist Injuries OUCH!

The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are

The Kienböck disease and scaphoid fractures. Mariusz Bonczar

Degrees Of Volar Angulation In Distal Radius Fracture Effects Distal Radioulnar Joint Stability:a Biomechanical Study

Anatomic Foveal Reconstruction of the Triangular Fibrocartilage Complex With a Tendon Graft

Thumbs Up! A Novel Use of the Acutrak Screw Fixation System for the Management of Triphalangeal Thumb

15 17 November 2018, Dubai, UAE. Event Overview

Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬

Carpal Instability: Clarification of the Most Common Etiologies and Imaging Findings

Recurrent subluxation or dislocation after surgical

Incidence 643,000 per year United States 15% of all fractures, peak occurrence age 60 70, Classification - AO/OTA (Murray 2013)

PROXIMAL AVULSION of RADIOCARPAL CAPSULE Parc Lesion: a new entity

University of Groningen. Fracture of the distal radius Oskam, Jacob

Another light in the dark: review of new method for the arthroscopic repair of triangular fibrocartilage complex

Primary internal fixation of fractures of both bones forearm by intramedullary nailing

UNFAVORABLE RESULTS AND degenerative arthritis. Arthroscopically Guided Osteotomy for Management of Intra-Articular Distal Radius Malunions

International Journal of Health Sciences and Research ISSN:

Transcription:

SCIENTIFICARTICLE ComparisonofUlnar-ShorteningOsteotomyWitha NewTrimedDynamicCompressionSystemVersusthe SynthesDynamicCompressionSystem:ClinicalStudy ShaiLuria,MD,AnthonyJ.Lauder,MD,ThomasE.Trumble,MD Purpose Ulnar-shortening osteotomy has become common in the treatment of symptomatic positive ulnar variance. Our goal was to evaluate prospectively a new dynamic compression plating system in comparison with a commonly used dynamic compression system. In contrast with other systems, the new system uses a slotted hole that enables fixation of the plate to the bone prior to performing the osteotomy, a fitted compression clamp, and a lag screw. Cutting guides that attach directly to plate eliminate the need for freehand osteotomies. Methods Thirty-seven patients were treated with a 3.5-mm, 6-hole dynamic compression plate with distraction device (Synthes, Paoli, PA) and compared with 17 patients treated with a new dynamic compression system manufactured by Trimed (Valencia, CA). Procedure length was recorded. The patients were evaluated for amount of shortening, pain, range of motion, grip strength, time to union, and return to work as well as with validated outcome measures. Results Improvement was found in all measures although no difference was found between the 2 groups other than significantly shorter length of operation with the Trimed system (a mean of 2 hours with the Synthes system vs 1 hour with the Trimed system). Ten plates were removed in the Synthes group and 4 plates were removed in the Trimed group because of symptomatic prominence of the plate. There were no infections, delayed unions, or nonunions in either group. Conclusions The new Trimed plating system for ulnar shortening was found to be as effective as the Synthes system and with a shorter procedure time. This may be related to the different measuring periods, although years of practice with the Synthes technique preceded this study. We believe the shortened procedure time for the Trimed system is due to its technical advantages. ( J Hand Surg 2008;33A:1493 1497. Copyright 2008 by the American Society for Surgery of the Hand. All rights reserved.) Type of study/level of evidence Therapeutic III. Key words Compression plate, forearm fracture malunion, positive ulnar variance, triangular fibrocartilage complex, ulnar osteotomy. THE ULNAR-SHORTENING OSTEOTOMY has become and the distal-most aspect of the dome of the ulnar the standard for correcting positive ulnar variance. Ulnar variance is defined as the differencethe distal ulna is more distal than the ulnar corner of the head. Positive ulnar variance occurs when the dome of in length between the distal ulnar corner of the radius distal radius. This positive variance may lead to ulnar- From the Department of Orthopaedics and Sports Medicine, University of Washington School of Medicine, Seattle, WA. OrthopaedicsandSportsMedicine, UniversityofWashington, 1959N.E. PacificSt., Box356500, Corresponding author: Shai Luria, MD, Hand and Microvascular Surgery, Department of Received for publication September 5, 2007; accepted in revised form May 23, 2008. Seattle, WA 98195; e-mail: lurias@u.washington.edu. T.E.T.wasinvolvedinthedevelopmentoftheTrimedSystempresentedinthearticle,butnobenefits of any form have been received or will be received related directly or indirectly to the subject of this article. 0363-5023/08/33A09-0006$34.00/0 doi:10.1016/j.jhsa.2008.05.021 2008 ASSH Published by Elsevier, Inc. All rights reserved. 1493

1494 CLINICAL COMPARISON OF ULNAR-SHORTENING SYSTEMS sided wrist pain and degenerative processes due to the overloading that occurs between the ulnar head and the ulnar carpus. Thus, the goal of the shortening procedure is to relieve the symptoms by reestablishing a neutral or slightly negative ulnar variance. 1 The typical indications for the osteotomy include ulnar impaction syndrome, nonrepairable tears of the triangular fibrocartilage complex (TFCC), attritional lunotriquetral ligament tears, radial malunions, and early posttraumatic distal radioulnar joint arthritis. 2 4 Previous radial head excision and associated Essex-Lopresti lesions may be an indication as well, along with replacement of the radial head. 3,4 Numerous authors have introduced methods and systems for performing, and hopefully simplifying, the osteotomy 2,5 8 to prevent malrotation, angulation, or nonunion because of incomplete closure of the osteotomy gap. This study compares the results of ulnar-shortening procedures with a new plate and compression system 9 to a previously described and accepted method. 8 FIGURE 1: The Bone Compression Clamp compressing the osteotomy site during insertion of a lag screw. (Illustration courtesy of Dr. Thomas E. Trumble.) MATERIALS AND METHODS Synthes dynamic compression system Thirty-seven patients had an ulnar-shortening osteotomy using a dynamic compression (DC) plate and an AO compression/distraction device (Synthes, Paoli, PA) between 1996 and 2004. The inclusion criteria for the study were ulnar-sided wrist pain with concomitant positive ulnar variance on standard radiographs (ulnar variance views 10 ) in patients between the ages of 18 and 65 years. Patients who were active smokers were excluded. Patients with no forearm fracture malunion were evaluated arthroscopically for possible repairable TFCC pathology prior to the osteotomy. All arthroscopies consisted of debridement and not TFCC repair. Approval by the institutional review board was obtained as well as informed consent from each patient. The procedure was performed as described by Chen and Wolfe. 8 Sixteen patients were men and 21 were women. Average patient age at the time of the shortening osteotomy was 36 years. The average ulnar positive variance was 3.8 mm (SD, 1.1). Six of the osteotomies were carried out for prior distal radius fractures that healed with shortening of the radius. Thirty-one of the osteotomies were performed for degenerative, nonrepairable tears of the TFCC confirmed in arthroscopy. This technique implements a 3.5-mm, 6-hole DC plate (Synthes). Perfectly parallel freehand osteotomies must be made at 45 angles to the plate. This is followed by the placement of a lag screw inserted perpendicular to the approximated osteotomies. After completing the osteotomy, the Synthes distraction device is used to further reduce and compress the distal and proximal bone ends. The length of the procedure was recorded. Trimed ulnar-shortening osteotomy (DC) system Seventeen patients had an ulnar-shortening osteotomy using a new system manufactured by Trimed (Valencia, CA), between 2004 and 2006. This system has replaced the Synthes plate in the senior authors practice. The patients were entered into the study in the similar fashion as prior to 2004, and the inclusion criteria were not changed. Approval by the institutional review board and informed consent were obtained. Seven of the patients were men and 10 were women. Average patient age at the time of surgery was 38 years. The average ulnar positive variance was 3.9 mm (SD, 1.4). Three of the osteotomies were performed to relieve symptoms stemming from distal radius malunions that had healed with shortening of the radius. The remaining 14 osteotomies were performed for degenerative TFCC tears confirmed in arthroscopy. This new system, designed by the senior author, implements a new plate design allowing for compression at the osteotomy site with a Bone Compression Clamp and lag screw (Fig. 1). In this system, the lag screw is placed through a guide ensuring perpendicular placement of the screw to the osteotomy. Unlike other techniques that require moving the plate prior to cutting the ulna, 8 this system uses a slotted hole so that the plate is firmly affixed prior to performing the osteotomy (Fig. 2). Furthermore, the system has cutting guides that attach directly to the plate, eliminating the need for

CLINICAL COMPARISON OF ULNAR-SHORTENING SYSTEMS 1495 FIGURE 2: The final osteotomy and plate construct. Note the slotted hole on the side of the plate with 3 screws (arrow). This hole eliminates the need to remove the plate during the saw cuts and allows for compression at the osteotomy site. (Illustration courtesy of Dr. Thomas E. Trumble.) FIGURE 3: Osteotomy guides attached directly to the plate. This eliminates the need for freehand parallel cuts. The saw placed through the guide slot is marked with an arrow. After the second cut, the slice of bone is removed. (Illustration courtesy of Dr. Thomas E. Trumble.) freehand osteotomies (Fig. 3). The guides are designed to perform the cuts according to the amount of shortening necessary. The technique was performed as previously described. 9 The length of the procedure was recorded. Postoperative protocol The postoperative protocol was similar in both groups. The patients were immobilized in a sugar-tong splint for 2 weeks followed by a removable forearm brace. Digit range of motion was encouraged immediately after surgery. After 2 weeks, motion was allowed in the brace, followed by gentle strengthening exercises after 6 weeks and maximal strengthening when bone healing was complete. Outcome measures All patients were evaluated for preoperative and postoperative range of motion and grip strength. These measures were recorded for the surgical side and then compared with the contralateral arm. Pain levels at the wrist were recorded using a visual analog scale. Patient upper-extremity function was established using the Disabilities of the Arm, Shoulder, and Hand (DASH) Outcome Measure. Ulnar variance was recorded before and after the procedure to measure the amount of shortening achieved by the osteotomy. The length of the procedure was recorded from the time of skin incision to wound closure. Time to union was evaluated both clinically and radiographically (defined as bridging of the trabecular bone and cortical margin blurring). Return to work and complications, including symptomatic hardware necessitating hardware removal were recorded. Statistical analysis Statistical analysis was performed with use of SPSS 15.0 for Windows software (SPSS Inc., Chicago, IL). The analysis of variance was calculated followed by the least significant difference using Scheffe s method to detect statistical differences between the preoperative and postoperative measures or the Wilcoxon signed ranks test for nonparametric measures. A p value of less than or equal to.05 was considered significant. RESULTS The average procedure length differed between the groups. The procedure lasted an average of 2 hours (SD, 0.3) for the Synthes DC group and 1 hour (SD, 0.3) for the Trimed group (p.05). All patients were followed for 12 months. Bony union was achieved at an average of 7 weeks for the Synthes DC system and 7 weeks for the Trimed system. Shortening of the ulna averaged 3.9 mm and 4.1 mm for the Synthes DC group and the Trimed group, respectively. Wrist pain scores decreased from an average of 6.0 preoperatively to 0.8 after surgery in the Synthes DC group. The patients in the Trimed group had a similar experience with their scores changing from 5.9 to 0.7. Thirty-four of the 37 patients of the Synthes DC group and 16 of the 17 patients of the Trimed group returned to their previous occupations. Three of the Synthes DC group and 1 of the Trimed group did not return to their previous work position or sports activities, although all patients returned to some form of work. Outcome measurements are detailed in Table 1. Complications In the Synthes DC group, 10 plates were removed for symptomatic prominence of the plate. Four plates were

1496 CLINICAL COMPARISON OF ULNAR-SHORTENING SYSTEMS TABLE 1. Outcome Measurements With the Synthes and the Trimed DC Systems Synthes DC System Trimed Ulnar-Shortening Osteotomy (DC) System Preoperative Postoperative Percent Contralateral (%) Preoperative Postoperative Percent Contralateral (%) Wrist flexion/extension 108 116 96 110 116 98 Wrist radial/ulnar deviation 34 40 92 36 44 96 Forearm pronation/supination 134 144 97 133 137 97 Grip strength 26 kg 32 kg 95 26 kg 34 kg 94 Pain (visual analog, 1 10) 5.97 0.78 NA 5.88 0.71 NA DASH scores 65.1 11.3 NA 65.4 10.4 NA NA, not applicable. removed in the Trimed group. There were no infections, delayed unions, or nonunions in either group. Two patients in the Synthes group and 1 in the Trimed group developed carpal tunnel syndrome during the follow-up period. We did not relate this to the procedure but to the population at risk. DISCUSSION The ulnar-shortening osteotomy has proven benefits for patients with ulnar-sided wrist symptoms (the clinical syndrome of ulnar impaction) stemming from positive ulnar variance. Presumably, wrist pain is relieved through a decompression effect provided by the correction of the radioulnar length discrepancy. Many methods for correcting this overloading of the distal ulna, lunate, and triquetrum have been proposed. In 1941, Henry Milch was the first to describe a shortening technique using nothing more than a wire and plaster immobilization. Plate and screw fixation of an osteotomy was not proposed until the early 1970s. Since that time, several plating systems have been developed to make a technically demanding procedure more facile while simultaneously decreasing complication rates. 2,5 8 This study compared patient outcomes of ulnarshortening osteotomies made with 2 different surgical systems and techniques. The Synthes DC system has been used with good results. However, this technique requires osteotomy cuts be made perfectly parallel to ensure good alignment and opposition of the cut bone ends. Furthermore, the plate must be moved during the procedure to complete the osteotomy. This adds both time and room for error. With the new system (Trimed), osteotomies are made through guides attached to the plate, thus eliminating freehand cuts, and the placement of the plate may be adjusted with the aid of sliding holes without the need for plate reapplication. In this study, we demonstrate the shorter duration of this procedure, presumably a result of these technical features. The fact that the Trimed system was used during a later period of the study may have influenced the procedure times. Improvement in the technical learning curve may possibly result in shorter operative time, not necessarily due to the ease of the technique. It should be noted that the years of experience of the senior author with ulnar osteotomies was achieved using the Synthes system, prior to the study. Yet the new Trimed system enabled us to achieve the same results with significantly less time. Our data show that patients improved rather dramatically after having ulnar shortening with either system. Postoperative range of motion and grip strength increased to nearly 100% of the contralateral side. Furthermore, DASH scores demonstrated that patients believed they were functioning at much higher levels after surgery, and visual analog pain scores dropped to near negligible levels. This illustrates the utility of this procedure in appropriately selected patients. Importantly, the similar results for both systems demonstrate our new system works as well as the well-established Synthes DC system technique. The new Trimed system offers several technical advantages, resulting in similar success, possibly with a shorter length of operation. REFERENCES 1. Palmer AK, Werner FW. Biomechanics of the distal radioulnar joint. Clin Orthop Relat Res 1984;187:26 35. 2. Rayhack JM. Technique of ulnar shortening. Tech Hand Up Extrem Surg 2007;11:57 65. 3. Scheker LR, Severo A. Ulnar shortening for the treatment of early post-traumatic osteoarthritis at the distal radioulnar joint. J Hand Surg 2001;26B:41 44.

CLINICAL COMPARISON OF ULNAR-SHORTENING SYSTEMS 1497 4. Boulas HJ, Milek MA. Ulnar shortening for tears of the triangular fibrocartilaginous complex. J Hand Surg 1990;15A:415 420. 5. Kitzinger HB, Karle B, Low S, Krimmer H. Ulnar shortening osteotomy with a premounted sliding-hole plate. Ann Plast Surg 2007; 58:636 639. 6. Sunil TM, Wolff TW, Scheker LR, McCabe SJ, Gupta A. A comparative study of ulnar-shortening osteotomy by the freehand technique versus the Rayhack technique. J Hand Surg 2006;31A: 252 257. 7. Labosky DA, Waggy CA. Oblique ulnar shortening osteotomy by a single saw cut. J Hand Surg 1996;21A:48 59. 8. Chen NC, Wolfe SW. Ulna shortening osteotomy using a compression device. J Hand Surg 2003;28A:88 93. 9. Lauder AJ, Luria S, Trumble TE. Oblique ulnar shortening osteotomy with a new plate and compression system. Tech Hand Up Extrem Surg 2007;11:66 73. 10. Adams BD. Distal radioulnar joint instability. In: Green DP, Hotchkiss RN, Pederson WC, Wolf SW, eds. Green s operative hand surgery. 5th ed. Philadelphia: Elsevier, 2005:605 644.