Achieve Broad Lipid Quantitation using a High-Throughput Targeted Lipidomics Method

Similar documents
LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

LC-Based Lipidomics Analysis on QTRAP Instruments

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Principles of Shotgun Lipidomics

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Modernizing the Forensic Lab with LC-MS/MS Technology

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Obtaining Answers to Biological Questions Sample Prep to Data Analysis. Jeremiah D. Tipton, Ph.D. SCIEX Advanced Workflow Specialist in OMICS

Key Advantages of Comprehensive Cannabis Analysis

SelexION Technology for Lipid Analysis: Pushing the Boundaries of Lipidomics

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

Digitizing the Proteomes From Big Tissue Biobanks

Glycerolipid Analysis. LC/MS/MS Analytical Services

Relative Quantitation of Human Polymorphonuclear Leukocyte Cell Membrane GPEtn Lipids

SCIEX Vitamin D 200M Assay for the Topaz System

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Profiling the Distribution of N-Glycosylation in Therapeutic Antibodies using the QTRAP 6500 System

Comprehensive Lipid Profiling of Human Liver Tissue Extracts of Non-Alcoholic Fatty Liver Disease

Overview. Introduction. Experimental. Cliquid Software for Routine LC/MS/MS Analysis

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Mass Spectrometry based metabolomics

The use of mass spectrometry in lipidomics. Outlines

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma

Increased Identification Coverage and Throughput for Complex Lipidomes

SUPPLEMENTARY DATA. Materials and Methods

LC/MS Method for Comprehensive Analysis of Plasma Lipids

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Measuring Lipid Composition LC-MS/MS

Screening and Speciation of Raw and Processed Meat Products

4th Multidimensional Chromatography Workshop Toronto (January, 2013) Herman C. Lam, Ph.D. Calibration & Validation Group

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Thermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Supporting information

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Fast, Robust and Reliable Method for the Identification and Quantitation of Sildenafil Residue in Honey using LC-MS/MS

Choosing the metabolomics platform

Lipid Class Separation Using UPC 2 /MS

Determination of Amantadine Residues in Chicken by LCMS-8040

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

AbsoluteIDQ p180 Kit. Targeted Metabolite Identifi cation and Quantifi cation

AbsoluteIDQ p150 Kit. Targeted Metabolite Identifi cation and Quantifi cation. Bringing our targeted metabolomics expertise to your lab.

Supporting Information

Made For Routine Food, Environment, and Forensic Testing

Identification of Ginsenosides Using the SCIEX X500R QTOF System

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

AbsoluteIDQ Kit: Targeted Metabolomics Identification and Quantification

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Agilent Solutions for Lipidomics. Greater Insight into

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

SUPPORTING INFORMATION FOR: CONCENTRATIONS OF POLYBROMINATED DIPHENYL ETHERS, HEXABROMOCYCLODODECANES AND TETRABROMOBISPHENOL-A IN BREAST MILK FROM

Accurate Quantification of Lipid Species by Electrospray Ionization Mass Spectrometry Meets a Key Challenge in Lipidomics

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Improved method for the quantification of lysophospholipids including enol ether

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Phospholipid characterization by a TQ-MS data based identification scheme

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Edgar Naegele. Abstract

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

Join the mass movement towards mass spectrometry

Polar Pesticides Method Update

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

High-throughput lipidomic analysis of fatty acid derived eicosanoids and N-acylethanolamines

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Annotation of potential isobaric and isomeric lipid species measured with the AbsoluteIDQ p180 Kit (and p150 Kit)

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Core E Analysis of Neutral Lipids from Human Plasma June 4, 2010 Thomas J. Leiker and Robert M. Barkley

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Lipids Analysis. Lipids

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

New Instruments and Services

Essential Lipidomics Experiments using the LTQ Orbitrap Hybrid Mass Spectrometer

Mass-Spectrometric Analysis of Lipids (Lipidomics)

The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides

New Frontiers for MS in Metabolipidomics

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

Improving Coverage of the Plasma Lipidome Using Iterative MS/MS Data Acquisition Combined with Lipid Annotator Software and 6546 LC/Q-TOF

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Transcription:

Achieve Broad Lipid Quantitation using a High-Throughput Targeted Lipidomics Method LC-Based Approach for Lipid Class Separation and Quantitation on QTRAP 6500+ System Mackenzie Pearson, Santosh Kumar Kapil, Sean Wu, Paul RS Baker SCIEX, MA, USA Direct infusion shotgun lipidomics is an established approach for broad-based lipidomic analysis 1. It is fast and simple, but it can suffer from inherent ion suppression effects, and due to the complexity of the lipidome and the extensive isobaric overlap, there is potential for ambiguous identification 2. Reverse and normal phase LC strategies coupled with MS are also frequently used for lipidomics analyses. These strategies separate lipids based on their physico-chemical properties, but the huge diversity of lipid molecular species makes development of standardized all-inclusive methods challenging, especially when quantitation is desired 3. Furthermore, discovery-based approaches such as information dependent acquisition (IDA) suffer from poor reproducibility, making quantitation unreliable 4. An efficient way to maximize sensitivity and specificity is through targeted lipidomics using HPLC and Multiple Reaction Monitoring (MRM) with a triple quadrupole-based mass spectrometer. A LC separation that can separate lipids into classes and subclasses is key to such an assay 5. Here, a targeted method is described using qualified MRM transitions and commercially available lipid internal standard mixtures, which provides quantitative measurement of ~1150 different lipid molecular species (Figure 1). The target list is can be shortened for a class-specific study or expandable to include new lipid classes. Benefits of LC-MRM and QTRAP 6500+ System for Targeted Lipidomics Optimized chromatography separates lipids by class, which reduces inter-class isobaric interferences (24 mins per sample). Individual lipid classes elute within a narrow RT window, making it simple to assign the RTs and implement scheduled MRM to achieve the detection of ~ 1150 lipids. QTRAP 6500+ system offers wide dynamic range, fast polarity switching scan (< 5msec), as well as high sensitivity even at high acquisition rates (2-5 msec dwell times) The MRM scan mode maximizes the sensitivity and the specificity, which enables rapid and facile quantitation. This method utilizes internal standards for developing time scheduled MRM methods as well as for downstream relative quantitative analysis. Figure 1. Overview of the LC-Based Targeted MRM Assay. The targeted lipidomics analysis via LC-MS/MS provides for rapid identification and quantification of a broad spectrum of lipid molecular species in bovine heart extract. MultiQuant Software automatically processes data using a pre-built processing method. p 1

Methods Sample Preparation: Bovine heart total extract (BHE, Avanti, 1g/100mL) is a commercially available lipid mixture that contains diverse lipid species: PC (5.4%), PE (6.8%), PI (2.5%), PA (1.1%), CA (2.3%), Neutral Lipids (DAG, TAG, MAG, DAG and CE; 49.8%), and other, including sphingolipids (32.1%). Available internal standards for retention time determination and for quantitation include the Avanti SPLASH standard mixture and the SCIEX Lipidzyer Platform kits 6. LC-MS Analysis: The LC separation was performed using a ExionLC System consisting of a binary high pressure mixing gradient pump with degasser, a thermostated autosampler, and a column oven (35 ºC). The QTRAP 6500+ system, equipped with an IonDrive Turbo V source, was operated in low mass mode with polarity switching. Retention times are first roughly determined using either the BHE with spiked internal standards or a representative matrix sample and the unscheduled MRM method. Analysis of this preliminary data enables the development of a time-scheduled MRM method leveraging the enhanced features in the Scheduled MRM Algorithm Pro. Details on the chromatographic and MS methods can be obtained from the Comprehensive Targeted Method for Global Lipidomics Screening 7. Data Processing: All data was processed using MultiQuant Software 3.0.2. Automated computation of the time scheduled final MRM methods was performed using the smrm Pro Builder v1 8. Figure 2. Negative Mode Strategy for More Complete Phospholipid Identification. In a typical MRM assay, MRMs that denote the phospholipid head groups in positive mode are used. Here, negative mode MRMs are used that provide information on fatty acid composition to provide information at the molecular species level. Figure 3. MultiQuant Software for Data Processing of Lipid MRM Data. Data acquired using either the unscheduled or time scheduled MRM methods can be quickly processed using MultiQuant software. Export of retention times, peak areas and peak widths are then used to fully optimize the final method. MRM Approach in Lipid Identification Here a large panel of MRM transitions have been developed to provide a targeted assay for a broad range of lipid species. The targeted list is composed of ~1150 lipid molecular species, including PC/LPC, PE/LPE, PS/LPS, PI/LPI, PG/LPG, PMAG, DAG, TAG, FFA, CE, CER, DCER, HCER, LHCER and SM. Lipid classes currently included in assay provide good coverage of lipids commonly found in mammalian plasma, tissues and cells. Additional lipids can be added to the assay depending on matrix as workflow is easily extensible. Most lipid classes and categories are acquired in the positive ion mode. However, for the targeting of phospholipids (PL), rather than using the more common approach via the head group loss in positive ion mode, this approach uses negative ion mode via the loss of fatty acid to identify the PL (PC, PE, PS, PI, PG) at the fatty acid composition molecular species level. As shown in Figure 2, the PC 34:2 can only be identified at the class level using the positive ion mode while the specific molecular species can be figured using the negative ion mode. Use of fast polarity switching on the QTRAP 6500+ system allows monitoring of both positive and negative MRMs providing a key advantage for this method. This level of molecular species specificity is often key to understanding the specific biology. p 2

Streamlined Method Development As the number of lipids covered in this method is large, it is important to use the Scheduled MRM Algorithm Pro approach during acquisition of biological dataset for highest quality quantitation results. Unique features such as the flexible window width per MRM, dwell time weighting and dynamic window extension are all leveraged. To streamline the development of this final assay, an Excel based smrm Pro Builder 8 has been developed to assist the user during the assay refinement steps. First the user collects MRM data on a representative matrix (with or without internal standards) for the upcoming biological study (3-5 replicates). Results from the first pass unscheduled MRM data are processed with MultiQuant software (Figure 3) and then entered into the smrm Pro Builder and an initial rough approximation of the retention times is determined. Next 5-10 replicate injections are performed on the matrix using a preliminary time scheduled MRM method, ideally a pooled sample from the biological samples. Data analysis here provides information on peak width, RT variance, and lipid signal and the smrm Pro Builder computes a final optimized Scheduled MRM Acquisition Pro method (Figure 4). After method construction, the Scheduled MRM Algorithm Concurrency tool 9 can be used to check the concurrency and hence resulting dwell time for the assay. Chromatographic Reproducibility The LC-MRM reproducibility was evaluated by injecting a plasma lipid extract (10 replicates) using the final Scheduled MRM Pro assay. Excellent reproducibility was observed with majority of lipid species showing retention time standard deviations below 0.05 minutes (Figure 5). Figure 4. Optimization of Scheduled MRM Algorithm Pro Assay using smrm Pro Builder Template. To obtain better quality data, the assay can be optimized further using the advanced features in the Scheduled MRM Algorithm Pro. Using the peak width and RT variance computed, an optimized MRM detection window can be included in assay for each lipid species (top). By measuring the relative peak areas of each molecular species, increased dwell time weights can be used for the lower abundant species, improving the quantitation quality (bottom). The types of enhancements improve the assay by maximizing dwell times while maintaining cycle time of the method. Figure 5. Reproducibility of the Chromatography for Plasma Replicates. (Top)Very reproducible chromatography was achieved with majority of lipid molecular species having retention deviations below 0.05 minutes (bottom). p 3

Quantitative Reproducibility Using the optimized Scheduled MRM Algorithm Pro acquisition method, 10 replicate injections were performed on plasma using the QTRAP 6500+ system. Reproducibility of quantitation was assessed by computed the %CV of the peak area replicates for the lipids within each class. Figure 6 (middle) shows the cumulative fraction of lipids in each class at each % CV level. For example, 16 LPE lipids were measurable in plasma were the 4 th most abundant class as measured by sum of peak areas (top) and showed the highest reproducibility (middle). All LPEs could be measured with CVs below 5%. The PG, PC, PI and PS classes were also measured with very good reproducibility with 80% of lipids quantified with 10% CV or better. The TAGs are a large class and 217 were measurable in this sample but were very low abundant and therefore had much lower reproducibility. Improved Results Quality with Scheduled MRM Pro Algorithm Advanced method features like Dwell Weighting and Flexible Window Width in Scheduled MRM Algorithm Pro allow for additional method optimization to further fine tune an MRM method with many transitions such as this. Using the smrm Pro Builder template and performing LC-MRM replicates, optimized values for these features can be determined. Results obtained using the Basic algorithm and the fully tuned Pro Algorithm were compared for 10 replicates of plasma matrix. Improvements in peak area reproducibility were observed for lipid species in the low abundant classes (PS, CER, MAG, Figure 6, bottom). Using Internal Standards for Quantitation It is important to note that quantitation of lipids via global lipid profiling is challenging. In this method, several options are available to quantitate lipid levels in samples. For relative quantitation, a single lipid molecular species for each lipid class is needed. This strategy corrects for extraction efficiency as well as systematic errors; however, this strategy should only be used for comparative analysis between two samples. Using this strategy, it is not correct to report the concentrations of individual lipid molecular species, because the fragmentation efficiency of different molecular species within the same class is not equal and depends on the length and the number(s) of double bonds present in the fatty acid that fragments in the negative ion mode. Using this strategy, it is possible to conclude certain lipids increase or decrease when two different samples are compared. SPLASH mix from Avanti Polar Lipids is a commercially available mixture of lipid internal standards that can be used for this quantitation strategy. Figure 6. Increased Area Reproducibility of Assay using Scheduled MRM Pro Algorithm. Rough composition of lipids in plasma was estimated by summing the peak areas of detected lipids in each class (top). Peak area %CV were computed across the 10 replicate injections and plotted for each lipid class (Middle). By optimizing the advanced method parameters available in the Scheduled MRM Pro Algorithm, improvements in results quality were seen for the low abundant classes as compared to running the basic time scheduled algorithm (bottom). p 4

A second strategy involves using multiple labeled internal standards to enable accurate quantitation (quantitative bias <10%); absolute quantitation requires a labeled internal standard for every analyte and is not possible in these experiments. Accurate quantitation can be achieved by assigning a structurally similar (but not necessarily identical) internal standard to each analyte. Recently, a comprehensive mixture of labeled internal standards was developed for the Lipidyzer Platform. Using these standards, accurate quantitation can be achieved for many but not all of the lipid classes targeted in this method (SM / DAG / CE / CER / TAG / LPE / LPC / PC / PE / FFA). The method reported here is flexible to either internal standard strategy through addition of the chosen internal standards to the sample and inclusion in the MRM method development. Summary In this study, a targeted global lipid profiling strategy is presented that enables a broad array of different lipids to be quantified at the molecular species level (~1150 molecular species). An optimized chromatography method was developed to minimize isobaric interference through the chromatographic separation of lipid class, which allows for a relatively rapid and specific lipid screening technique. The target list of lipids is comprehensive, covering most major lipid classes and categories, and MRMs were selected to cover lipids containing fatty acids with 14-22 carbons and 0-6 double bonds. The method is customizable, so new lipid categories, classes and molecular species can be added. Results quality of the method has been demonstrated in plasma matrix to highlight both the robustness and the flexibility of the LC-MRM assay. References 1. Han X, Yang K, Gross RW. Multi-Dimensional Mass Spectrometry-Based Shotgun Lipidomics And Novel Strategies For Lipidomic Analyses. Mass Spectrometry Reviews. 2012; 31(1): 134-178. 2. Bielow C, Mastrobuoni G, Orioli M, Kempa S. On Mass Ambiguities in High-Resolution Shotgun Lipidomics. Anal Chem. 2017; 89: 2986-2994. 3. Ovčačíková M, Lísa M, Cífková E, Holčapek M. Retention behavior of lipids in reversed-phase ultrahigh-performance liquid chromatography-electrospray ionization mass spectrometry. J. Chromatogr A. 2016; 10(1450), 76-85. 4. Koelmel JP, Kroeger NM, Gill EL, Ulmer CZ, Bowden JA, Patterson RE, Yost RA, Garrett TJ. Expanding Lipidome Coverage Using LC-MS/MS Data-Dependent Acquisition with Automated Exclusion List Generation. J Am Soc Mass Spectrom. 2017. 28(5), 908-917. 5. Hines KM, Herron J, Xu L., Assessment of Altered Lipid Homeostasis by HILIC-Ion Mobility-Mass Spectrometry- Based Lipidomics. J Lipid Res. 2017. doi: 10.1194/jlr.D074724 6. Novel Chemical Standards Kits Enable Facile Lipid Quantitation. SCIEX Technical note RUO-MKT-02-3879-A. 7. SOP link 8. smrm Pro Buildter Template link 9. Concurrency calculator link An easy to use tool (smrm Pro Builder template) was also developed to streamline the optimization of the targeted MRM assay to maximize results quality when performing assay with very large numbers of time scheduled MRM transitions. AB Sciex is doing business as SCIEX. 2018 AB Sciex. For Research Use Only. Not for use in diagnostic procedures. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. Document number: RUO-MKT-02-8482-A p 5