IR (INTELLIGENT) INTERNAL ONE-STAGE SYSTEM
MESSAGE FROM THE CEO Our company, Biotem Co. Ltd, has been working to improve and enhance dental implant technology for many years in order to provide the most satisfying product for both patients and dentists. With this accumulated experience, our technical know-how has reached a very high level. We have gained international certificates such as ISO 485, CE together with KGMP, and we have stepped into the world-wide market. Currently, Korea s standard of dental implant technology is one of the best, most advanced in the world. Patients are now seeking a more advanced implant service. Therefore, to meet the patients high expectations, dentists and implant companies have been trying to increase their technological standards. For this reason, Biotem has also developed a new technology, called Bio-Dental Implant System, and soon we can start the mass production process. Biotem implant products - Dentists can operate more safely and easily and patients can be satisfied with full credibility. We will make every effort to become an excellent world-leading company that will keep developing innovative technology in order to improve the lives of people around the world. Y. H. Lee, President 3
HISTORY 2006 2008 2009 20 2012 > March. Launching of new development of biotem implant system. > February. Establishment of biotem implant factory in Busan, Korea. > August. Establishment of Biotem co.,ltd. (Co-C.E.O by Y.H Lee and S.K Choi). > November. Obtained licence of manufacturing of medical devices by K.F.D.A. > November. Obtained certificate of external type of fixture (certi no: 08-834). Obtained certificate of abutment ( certi no: 08-834) > December. Obtained certificate by K.G.M.P. > January. Obtained certificate of internal type of fixture (certi no: 09-56). > March. Obtained certificate of internal sub-merged type of fixture (cert no: 09-6). > April. Obtained certificate of internal paragon type of fixture (certi no: 09-321). > May. Signed agreement of technical co-operation for the surface treatment of fixture for ha-coating system with Platon, Japan co., Ltd. > May. Registered as a foreign manufacturer of medical devices by ministry of health and welfare of Japan. > June. Obtained certificate of i.s.o 485:2003. > October. Obtained certificate of C.E 0120. > November. Inauguration of Y.H.Lee as a C.E.O of biotem co., Ltd. > June Establishment of overseas branch office in Japan and Taiwan. > November. Obtained the authorization of venture company (High technological based-on company) by Korean government authority. > April. Obtained the certificate of first qualified degree of medical devices products by ministry of health and welfare of Taiwan. IR (INTELLIGENT) INTERNAL ONE-STAGE SYSTEM > Features and Advantages > Surface Treatment > Prosthetic Flow Chart > IR Fixture (Internal One-Stage) > IR Fixture (Internal ITI Original) > Closing Screw > Cover Screw > Healing Abutment > Solid Abutment > Wide Solid Abutment > Impression Coping > Solid Analog > Plastic Coping > Impression Coping (Pick-up Type) > Fixture Analog > Cemented Abutment > Angled Abutment 4 5
SURFACE TREATMENT FEATURES AND ADVANTAGES SURFACE TREATMENT (RBM) SURFACE OBSERVATION RESULT X 500 X 2000 IR FIXTURE > Ra: Average 1.89µm > Sdr: Average 83.34% MORSE TAPER IMPLANT-ABUTMENT CONNECTION SURFACE (XPS DATA) DIFFERENT CUFF HEIGHTS REDUCED THREAD PITCH SELF TAPPING CONICAL DESIGN S Wide scan C Ca P RBM SURFACE Ti 6 7
PROSTHETIC FLOW CHART IR Fixture IR Fixture Closing Screw Healing Abutment Closing Screw Healing Abutment Solid Abutment Impression Coping Impression Coping Fixture Analog (Integrated) Solid Analog (Integrated) Cemented Abutment Angled Abutment Single Plastic Coping Bridge Abutment Screw (Set Screw) 8 9
IR FIXTURE (INTERNAL ONE-STAGE) IR FIXTURE (INTERNAL ITI ORIGINAL) Cuff Length Platform Diameter FIXTURE Mini Regular Wide ø 3.5 ø 4.1 ø 4.1 ø CUFF 1.8 1.8 2.8 1.8 2.8 2.0 2.0 LENGTH 7 FXIR 3508 M FXIR 35 M FXIR 3511 M FXIR 35 M FXIR 35 M FXIR 4007 M FXIR 4008 M FXIR 40 M FXIR 4011 M FXIR 40 M FXIR 40 M FXIR 4008 FXIR 40 FXIR 4011 FXIR 40 FXIR 40 FXIR 4807 M FXIR 4808 M FXIR 48 M FXIR 4811 M FXIR 48 M FXIR 48 M FXIR 4808 FXIR 48 FXIR 4811 FXIR 48 FXIR 48 FXIR 4808 W FXIR 48 W FXIR 4811 W FXIR 48 W FXIR 5507 FXIR 5508 FXIR 55 FXIR 5511 Cuff Length Platform Diameter FIXTURE Mini Regular Wide ø 4.1 ø 4.5 ø 4.1 ø CUFF 1.8 1.8 1.8 2.8 2.8 2.0 2.0 LENGTH FXIR 4007 MG FXIR 4008 MG FXIR 40 MG FXIR 4011 MG FXIR 40 MG FXIR 40 MG FXIR 4507 MG FXIR 4508 MG FXIR 45 MG FXIR 4511 MG FXIR 45 MG FXIR 45 MG FXIR 4807 MG FXIR 4808 MG FXIR 48 MG FXIR 4811 MG FXIR 48 MG FXIR 48 MG FXIR 4007 G FXIR 4008 G FXIR 40 G FXIR 4011 G FXIR 40 G FXIR 40 G FXIR 4807 G FXIR 4808 G FXIR 48 G FXIR 4811 G FXIR 48 G FXIR 48 G FXIR 4807 WG FXIR 4808 WG FXIR 48 WG FXIR 4811 WG FXIR 48 WG FXIR 5007 G FXIR 5508 G FXIR 55 G FXIR 5511 G FXIR 55 G > Machined surface cuff: affinity with the gingival tissue and easy to manage plagues. > Limited implantation torque: 50Ncm. > No mount system: using a special fixture driver with more durability and easy separation - connection to fixture. > Machined surface cuff: affinity with the gingival tissue and easy to manage plagues. > Limited implantation torque: 50Ncm. > No mount system: using a special fixture driver with more durability and easy separation - connection to fixture. 11
CLOSING SCREW SOLID ABUTMENT SIZE PLATFROM HEIGHT Mini / Regular () Wide Neck () CSI 4000 CSI 4805 W Height Mini / Regular SAIS 48354 SAIS 48355 SAIS 48357 COVER SCREW > Using in the case of the limited adjacent space or the insufficient gingival of the suture part. > Using a 1.2 Hex Driver > Fastening torque: 5~8Ncm > Stable connection structure of 8º Morse Taper method. > Using for making the cement typed prosthesis. > Fastening torque: 30Ncm SIZE HEIGHT WIDE SOLID ABUTMENT Mini / Regular ø 1.5 HAI 48601 PLATFROM HEIGHT > Using a 1.2 Hex Driver > Fastening torque: 5~8Ncm Height Mini / Regular Wide Neck SAIS 48434 SAIS 48435 SAIS 48437 SAIS 604 EW SAIS 605 EW SAIS 607 EW HEALING ABUTMENT Height SIZE Mini / Regular ø HEIGHT 2.0 3.0 HAI 48602 HAI 48603 HAI 48604 > Stable connection structure of 8º Morse Taper method. > Using for making the cement typed prosthesis. > Fastening torque: 30Ncm Wide Neck ø 6.5 2.0 6.0 HAI 60702 HAI 60704 HAI 60706 > Using a 1.2 Hex Driver > Fastening torque: 5~8Ncm 12
IMPRESSION COPING IMPRESSION COPING (PICK-UP TYPE) PLATFORM PLATFORM OCTA (for solid) (for wide solid) (for wide neck solid) IPI 48 IPI 48 E IPI 60 EW 3.1 IPI 4808 M IPI 4812 M IPI 4808 IPI 4812 > A coping for the impression of Solid Abutment. IPI 6008 EW IPI 6012 EW SOLID ANALOG > A component that is used in the impression to transfer the position of an implant or analog to a model. > A 1.2 Hex Driver is needed to connect to the guide pin. PLATFORM HEIGHT Wide Solid LAIS 48354 LAIS 48355 LAIS 48357 LAIS 4854 E LAIS 4855 E LAIS 4857 E FIXTURE ANALOG LAIS 604 EW LAIS 605 EW PLATFORM OCTA Mini 3.1 LAIF 4812 M > An integrated Lab analog of abutment and analog. Regular LAIF 4812 Wide Neck LAIF 6012 W PLASTIC COPING TYPE Single Bridge PCI 4801 PCI 4801 N > A replication of the master model and manufacture a prosthesis with joining an abutment. Single Wide Solid Single Bridge PCI 4801 E PCI 4801 EN Single Bridge PCI 6001 PCI 6001 N Bridge > A coping for casting of the prosthesis in a solid analog of master model. 14
CEMENTED ABUTMENT BIOTEM SURGICAL KIT PLATFORM OCTA HEIGHT Height Regular Regular 3.1 SAIT 40434 SAIT 40435 SAIT 40437 SAITB 40434 SAITB 40435 SAITB 40437 POINT DRILL CODE PD 2029 Wide SAITB 604 EW SAITB 605 EW SAITB 607 EW STRAIGHT DRILL > Using for making the cement typed prosthesis. > Fastening torque: 30Ncm > Octa size: / 3.1 ø 2.0 L CODE BSD 2008 20 2011 20 20 MARKING DRILL ANGLED ABUTMENT D ø 2.7 ø 4.6 ø 5.0 ø 5.6 PLATFORM OCTA θº CODE MDR 27 46 50 56 Mini 3.1 º 25º AAIT 354 AAIT 35425 CORTICAL DRILL Octa Regular Wide neck º 25º º 25º AAITB 354 AAITB 35425 AAITB 60 W AAITB 6025 W D ø 3.4 ø 3.7 ø ø 4.5 ø 5.0 CODE CDA 3411 3711 4011 4511 5011 6011 CDA 3411T 3711T 4011T 4511T 5011T 6011 T > Using for adjusting the path of a prosthesis. > Using a 1.2 Hex Driver. > Fastening torque: 30Ncm 16 17
TAPERED DRILL PARALLEL PIN CODE DGA 1620 ø 3.0 L CODE BTD 3008 30 3011 30 30 DRILL EXTENSION CODE ETB 4526 L ø 3.3 CODE BTD 3308 33 3311 33 33 FIXTURE DRIVER IR TYPE L CODE LENGTH ø 3.6 CODE BTD 3608 36 3611 36 36 Mini FDIM 38 FDIM 3112 Short For Machine Regular / Wide FDIM 2908 FDIM 2912 Short L ø 3.8 CODE BTD 3808 38 3811 38 38 Mini CODE FDIH 38 FDIH 31 LENGTH Short For Wrench Regular / Wide FDIH 2908 FDIH 29 Short L ø 4.2 CODE BTD 4208 42 4211 42 42 18 19
HAND DRIVER SURGICAL KIT CODE LENGTH STARTER KIT 0.9mm HDB 09 1.2mm HDB 1208 Short 1.2mm HDB 12 Driver Cap (option) CODE LENGTH 1.2mm HDT 1208 HDT 12 Short Biotem Torque Wrench PROFESSIONAL COMPLETE KIT Biotem Torque Wrench 20 21
CERTIFICATIONS ISO CE CE / ISO ATTACHMENT CERTIFICATE OF MANUFACTURER 22
www.biotemdental.com Korea Headquarters # A-504 Woolim Lions Valley, #146-8 Sang Dae Won Dong, Jung Won Gu, Seongnam city, Kyeong Gi Do, Korea. Tel. 82-2-6278-3050 Fax. 82-2-6278-3052 Distributed by