Locator retained mandibular complete prosthesis (isy Implant System)

Similar documents
Replacement of a missing posterior tooth in the mandible (isy by CAMLOG)

Cost-effective immediate restoration in the anterior region of the mandible (isy by CAMLOG)

isy indications and techniques

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

Implant Restorations: A Step-By-Step Guide

Safety and esthetics with

Guided surgery as a way to simplify surgical implant treatment in complex cases

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

IMPRESSION PROCEDURES TRAINING MANUAL

MEDICAL UNIVERSITY OF VARNA FACULTY OF DENTAL MEDICINE DEPARTMENT OF PROSTHETIC DENTAL MEDICINE GOVERNMENT EXAMINATION SYLLABUS

US Implant System 2013 PROSTHETIC PROCEDURE

a perfect fit CAMLOG GUIDE SYSTEM Planning, template fabrication and implantation

Full Arch Rehabilitation All-on-4 Technique Restorative Steps Recipe for Success

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

From planning to surgery: a totally digital working flow for Leone implants placement

Innovative Präzision Made in Germany

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

The intelligent system.

Mini implants for Stabilization of partial dentures

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

SS Implant System 2013 PROSTHETIC PROCEDURE

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

Generation fifty plus: Restoring a natural smile

Solid Zirconia Full-Arch Implant Prosthesis (Protocol C All-CAD with Multi-Unit Abutments) BruxZir. FIRST Appointment. The BruxZir

Fixed Partial Dentures /FPDs/, Implant Supported. in implant prosthodontics

Lect. 14 Prosthodontics Dr. Osama

» QuattroFix treatment concept by MEDENTIKA «

Element-Z Screw-Retained Hybrid

DIGITAL DIAGNOSIS AND TREATMENT PLANNING FOR PLACEMENT AND RESTORATION OF SINGLE IMPLANTS IN THE POSTERIOR MAXILLA By Timothy Kosinski, DDS

Restorative Driven Implant Solutions Utilizing the Latest Technology

Prosthetic V. Removable dentures I.

UNDERSTANDING DIGITAL DENTISTRY: CBCT AND INTRA-ORAL 30 SCANNING

Contemporary Implant Dentistry

Rehabilitation of Resorbed Mandibular Ridge with Implant Supported Overdenture- A Clinical Report

Patient s Presenting Complaint V.C. presented with discomfort and mobility from the crowned maxillary left central incisor tooth. Fig 1.

IMPLANTS. Pearls. Your Precious Pearls. Made in Germany

NARROW DIAMETER implant

TRIPOD A new protocol for immediate loading

RESTORATION OF A FULLY EDENTULOUS PATIENT UTILIZING SIMPLE TECHNIQUES FOR IMPRESSION AND FABRICATION OF A HYBRID BRIDGE

CHAPTER. 1. Uncontrolled systemic disease 2. Retrognathic jaw relationship

Ankylos. Laboratory Manual

EasyLineImplant. Guided Surgery

SimpleLine II Surgical / Prosthesis Manual

Prosthodontic Procedure

4766 Research Dr. San Antonio, TX insightdentalsystems.com

For the oral rehabilitation

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Even faster thanks to ExpertEase Immediate restoration directly following implant placement. new

Hex-Lock Abutment System. Restorative Manual

Steps in construction of an interim dental implant-supported hybrid prosthesis:

Much has been written about the success of various

Ankylos. Product Catalog

INTRODUCTION. Why Choose Cortex Prosthetics?

The REAL Mini Implant

Prosthodontic Procedure

Removable partial dentures

PEN-040. Root Canal Model (length measurement) PEX-01. Tooth Extraction Model PIM-01. Implant Insertion Mandible Model

Featured Patient Case #1: Complete Mouth Reconstruction with Hybrid Restorations

EFFECTIVE DATE: 04/24/14 REVISED DATE: 04/23/15, 04/28/16, 06/22/17, 06/28/18 POLICY NUMBER: CATEGORY: Dental

Xive. Product Catalog

prosthetic technique manual

Conus Concept: A Rewarding Complete Denture Treatment

GMI. MONOLITH implant system. Surgical procedures guide

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

م.م. طارق جاسم حممد REMOVABLE PARTIAL DENTURE INTRODUCTION

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

Continuing Education. Implant Prosthetics for the General Practice. Samuel M. Strong, DDS

Implant Phase Flow Chart

SuperLine & Implantium Surgical / Prosthesis Manual

OCCLUSALLY SCREW-RETAINED

Quick start Prosthetics

Smarter Thinking. Simpler Design. TiLobe Prosthetic Manual for PrimaConnex & Genesis implants

Prosthodontic Procedure

Blue Sky Bio Multi unit Abutments BIO Multi-Units are available for all our Bone Level Implants

Implant Studio Patient Case

ident CT Guide Protocol

Osseointegrated dental implant treatment generally

GMI FRONTIER implant system. Surgical procedures guide

CHECK-UP Determination of Impression type & Method after implant placement

The patient gave a history of hypertension and gastritis for which was taking Lacidipine 4mg, Omeprazole 20mg and Simvastatin 40mg.

Long-term success of osseointegrated implants

For technical assistance: Tel Working time: 8.30 am pm

Real World Implant Prosthetics: Fixed and Removable Samuel M. Strong, DDS

Fig. 2: The initial clinical situation is characterized by gaps between the upper and lower anterior teeth.

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

NEODENT GUIDED SURGERY

MANAGEMENT OF ATROPHIC ANTERIOR MAXILLA USING RIDGE SPLIT TECHNIQUE, IMMEDIATE IMPLANTATION AND TEMPORIZATION

cement-retained single crowns using cementable abutments

» For multi-unit restorations -

SuperLine & Implantium Surgical / Prosthesis Manual


GuidedService. The ultimate guide for precise implantations

In 1977, Lew1 developed a passive

Oral Rehabilitation with CAMLOG implants after loss of dentition due to an accident

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

Case report: Replacement of failing 2 stage implants by basal implants and conventional bridgework

3D Printing Technology ----Applications in Dentistry

INTERNATIONAL MEDICAL COLLEGE

Transcription:

Locator retained mandibular complete prosthesis (isy Implant System) Mucosa-supported complete prostheses with poor fit greatly reduce people's quality of life. This is why the importance of implant-supported prosthetic restorations is increasing among the group of edentulous patients. If this wish is accompanied by limited financial resources, then simplified therapeutic approaches can be offered, for example, a Locator retained prosthesis. This type of restoration, in conjunction with the implant system isy by CAMLOG, is both efficient and financially attractive. Case presentation The 76-year-old female patient has been edentulous for over 20 years and wears purely mucosa-supported complete prostheses. In particular, the mandibular prosthesis displays a poor fit and severely restricts the patient in everyday life. After consultation, she decided in favor of an implant-supported restoration, but refused extensive surgical measures. The transgingival healing implant isy by CAMLOG was selected as the implant system. Prosthetic restoration was to be performed using a Locator retained prosthesis. Despite the highly atrophied mandible, elaborate surgical measures (for example, vestibuloplasty) as well as computer-guided planning could be dispensed with. A new, mucosa-supported prosthesis was to be fabricated for the maxilla. Authors: Dr. K.-L Ackermann, MDT G. Neuendorff, MDT Ch. Hammerl-Riempp Indication: Locator retained mandibular complete prosthesis October 30, 2014 1

Fig. 21 Fig. 23 1 Fig. 1: initial situation the edentulous patient displays the typical aged facial features without her dentures. It is planned to fabricate new dentures for the mandible and the maxilla. Because of the poor prosthetic base in the mandible, a Locator retained prosthesis was to be used after the insertion of four implants (isy by CAMLOG). Fig. 2: articulated situation models impression taking of the situation and cast fabrication respectively, demonstrated a large vertical distance that needed to be bridged. The jaw bone in the mandible is extremely atrophied. In addition, bone resorption in the maxilla led to a sagittal back-shift. 2

Fig. 23 Fig. 3: wax try-in the pre-operative and intraoperative information necessary for the implant prosthetic restoration in the mandible was obtained on the basis of a functional and esthetic tooth set-up in the patient's mouth. 3

Fig. 4 Fig. 52 Fig. 3 Fig. 4: x-ray template the set-up is transferred to radiopaque (teeth) and transparent (base) resin to fabricate the x-ray template. This is followed by planning of the implant positions. Taking the tooth inclination into account, four implants are planned in vestibular orientation and the drill sleeves are inserted into the template accordingly. Fig. 5: evaluation of the implant positions a panorama layer x-ray is taken using the inserted x-ray template. This ensures good twodimensional orientation and confirms that the four implants can be inserted in regio 34, 32, 42 and 44. 4

Fig. 26 Fig. 37 Fig. 6: pre-drilling the x-ray template is reduced in the region of the implant positions and the prepared transfer template is repositioned after exposing the bone with an alveolar ridge incision. The position and axial direction of the implants (drill with Ø 2 mm) is acheived through the drill sleeves. Fig. 7: after removing the template, the pre-drilled hole is expanded with a round bur (Ø 3.5 mm) whereby the sphere is sunk to the equator. This pilot drilling is followed by pre-drilling (Ø 2.8 mm) to the desired implant length. 5

Fig. 98 Fig. 9 Fig. 8: preparation the isy Direction and depth indicators are inserted into the drill holes for form drilling orientation purposes and then the preparation of the implant beds is completed with the single patient form drills included in the isy Implant set. Preparation is performed with only slight pressure, swiftly and under generous cooling. Fig. 9: the sterile packaged implants are supplied with gingiva former and multifunctional cap pre-mounted on an implant base. The isy Insertion tool is used to remove the implant from the packaging. 6

Fig. 10 Fig. 11 Fig. 10: insertion the implant is placed in the oral cavity with the insertion instrument, inserted manually. Fig. 11: the implant is then driven into its final position using the isy Torque wrench. The transition from the micro-rough (Promote plus) to the machined surface is at bone level. The implant base acts as insertion post as well as base for the gingiva former. 7

Fig. 12 Fig. 13 Fig. 12: the gingiva formers are mounted on the implant bases via a snap mechanism and the soft tissue is sutured peri-implant free of saliva. The temporary prosthesis is ground at the implant emergence sites, the base is lined with permanent soft plastic and the patient discharged from the dental practice. Fig. 13: good healing and a healthy peri-implant soft tissue were achieved after the healing period. 8

Fig. 14 Fig. 15 Fig. 14: isy Multifunctional cap the isy Multifunctional cap is also included in the set together with the isy Implant (with pre-mounted implant base) and the gingiva former. Fig. 15: the isy Multifunctional caps are mounted on the implant bases after removing the gingiva formers. 9

Fig. 16 Fig. 16: The multifunction cap can be used for determining the jaw relationship and bite registration. In addition, the multifunctional caps are used for impression taking. After temporary removal of the implant bases, the gingival height of the Locator abutments can now be selected according to the mucosal thickness. The repositioned implant bases with gingiva formers now remain in the patient's mouth until insertion of the final restoration. 10

Fig. 20 17 Fig. 21 18 Fig. 21 Fig. 17: master cast after screwing the lab bases and lab analogs together and mounting the multifunctional caps, the master cast is then fabricated. Fig. 18: after removal of the multifunctional caps and implant bases, the previously selected Locator abutments are screwed on and a nonprecious metal framework is fabricated over the Locator housings for the prosthetic base. 11

Fig. 20 19 Fig. 21 20 Fig. 21 Fig. 19: To obtain maximum precision and freedom of tension of the final restoration, bonding of the four Locator housings should be performed in the patient's mouth. Fig. 20: basal view of the non-precious metal framework bonded to the Locator housings in the mouth. 12

Fig. 21 Fig. 21: esthetic try-in in a second wax try-in, the esthetic, functional and phonetic parameters are checked and then the wax prostheses are transferred to plastic. 13

Fig. 22 Fig. 23 Fig. 22: basal view of the completed prosthesis for the mandible. The replacement males are inserted. Fig. 23: insertion of the prosthesis the peri-implant gingival situation is free of irritation. The soft tissue adapts beautifully to the Locator abutments. 14

Fig. 24 Fig. 24: the inserted prostheses. The denture in the severely atrophied mandible is retained on the isy Implants via Locators and displays no movement. The patient is highly pleased with the esthetic and functional result of the restoration. 15

Fig. 25 Fig. 25: owing to the limited budget of the patient, the selected restoration represented an optimal solution. The isy by CAMLOG Implant System ensures an efficient and cost-effective procedure with a reduced range of components. 16