Automated Hematology Analyzer. Differentiate with the XT-4000i

Similar documents
Lavender Top Management SUCCESS BEYOND FINANCES

Lavender Top Management SUCCESS BEYOND FINANCES. Mission/ Vision

CELL-DYN Strength in Technology, Proven Reliability. Optical WBC Technology. Patented M.A.P.S.S. Differential. Multiple Technologies

CELL-DYN 3700 Strength in Technology, Proven Reliability

10/30/2015. XN Case Studies: Every Picture Tells a Story

INFECTION/ INFLAMMATION

Full Blood Count analysis Is a 3 part-diff good enough? Dr Marion Münster, Sysmex South Africa

XN-SERIES. XN Technology and Case Studies

RD-100i OSNA the new generation of sentinel lymph node analysis in breast cancer

Hematology 101. Cindy Rogers, MT(ASCP) Diagnostics System Specialist

LEANING Away Waste and Improving Patient Care with Advances in Hematology

XN-SERIES. Hematology Case Studies: Every Picture Tells a Story

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

A Look Into the Determination of Cell Morphology in Hematology in the 21 st Century. Ramon Simon-Lopez, MD Global Scientific Director Beckman Coulter

Getting Beyond the Flags: Quantitative assessment of immature granulocyte (IG) populations may improve the assessment of sepsis and inflammation.

3. Blood Cell Histograms:

HM5. Hematology Analyzer BETTER. ACTUALLY.

Sysmex Journal International Vol.9 No.2 (1999)

5/1/2017 DISCUSSION POINTS. Clinical Utility of Immature Cell Indices Beyond the Routine CBC John E. Donnelly BSN, RN

Literature List Body Fluids

Auto Validation and Management Reports Using Sysmex WAM. Alfonso Ziccardi Laboratory Operation Manager for AP/CP/Safety Officer

It s Easier Than you Think How to Implement the Advanced Clinical Parameters

Performance evaluation of Celltac G: a new automated hematology analyzer

Advanced Hematology Five-Part Differential. Simple Operation

RD-100i OSNA the new generation of sentinel lymph node analysis in breast cancer

3/31/2017 OBJECTIVES CASE STUDY #1 MANUAL REVIEW. Hematology Case Studies: Every Picture Tells a Story

Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation

Brief Communication Diagnostic Hematology

Usefulness of NEUT-X determination in routine diagnostic procedures: application to myelodysplastic syndromes. F. Cymbalista.

of s and s Disclosure

Clinical use of flow cytometry

Sysmex Journal International Vol.26 No.1 (2016)

CASE STUDIES PERIPHERAL BLOOD AND BODY FLUIDS

Guide to the 1-3 Minute Blood Film Microscopic Review: Why and How?

DR SUDHIR MEHTA MD,MNAMS,FICP. Senior Professor & Head Medical Unit SMS Medical College & Hospital Jaipur

XN series. Case interpretation. Gebruikersdag Vlaanderen- 6 oktober 2016

Hematology & Coagulation Practicum Objectives CLS - 647

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Evaluation of the Abbott Cell-DYN 3500 Hematology Analyzer in a University Hospital

8/28/2015. ACP Toolbox SYSMEX CLINICAL SUPPORT TEAM SYSMEX CUSTOMER RESOURCE CENTER. Maggie Fischer BSN, RN, MS Carolyn Williams, BSN, RN, CRNI

Precision and Accuracy of the Leukocyte Differential on the Sysmex XE-2100

Interpreting Hematology Scatter-Plots; One Cancer Center s Keys to Seeing the BIG Picture

Customer Information Literature List White Blood Cells

Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens

Rapid Laboratories In House Tests

Blutbild 2012: Automatisiert oder manuell? Georg Stüssi Servizio di Ematologia Istituto Oncologico della Svizzera Italiana

Collect and label sample according to standard protocols. Gently invert tube 8-10 times immediately after draw. DO NOT SHAKE. Do not centrifuge.

Elekta Synergy Digital accelerator for advanced IGRT

Use of the XE-2100 in a Patient with Cold Auto-immune Hemolytic Anemia

9/23/2018. Hematology Case Studies Jason Anderson, MPH, MT(ASCP) Field Product Specialist OBJECTIVES FLUORESCENT FLOW CYTOMETRY

Combining. and New Diagnostic. to Help Clinicians Achieve. Patient Outcomes at. per Healthcare Encounter

Differential Blood Smear H3

Evaluation of the Diagnostic Performance of the Sysmex XT-2000i Automated Hematology Analyzer in the Detection of Immature Granulocytes

EDUCATIONAL COMMENTARY BLOOD CELL IDENTIFICATION

Versatile, affordable ultrasound. Philips HD6 ultrasound system. The print quality of this copy is not an accurate representation of the original.

Complete Blood Count (CBC)

NOTE: This table will be discontinued after this lot.

Complete Blood Count (CBC) Assist.Prof. Filiz BAKAR ATEŞ

M. Velizarova, T. Yacheva and K. Tzatchev Department of Clinical Laboratory and Clinical Immunology, MU Sofia

Evaluation of the Abbott CELL-DYN 4000 Hematology Analyzer

Reliable versatility. Philips HD5 ultrasound system

WHITE PAPER IMMATURE GRANULOCYTE (IG) POPULATIONS MAY IMPROVE THE ASSESSMENT OF INFECTION AND SEPSIS. Getting beyond the flags.

Quality control in the hematology laboratory for the sake of the patient. Dr Marion Münster Manager Medical & Scientific Affairs Sysmex South Africa

CYBERKNIFE M6 SERIES: Unmatched Precision and Patient Comfort

Evaluation of haematology analyzer CELL-DYN 3700 SL

Please contact Customer Service with any questions. Ph: option 5

2008 CAP TODAY Q & A

HSCT MANAGEMENT WHITE PAPER. Managing stem cell apheresis effectively

Quantitative Measurement of Cardiac Biomarkers

cobas u 601 urine analyzer Providing precise and secure test results

Evidence-Based Hematological Solutions

Differential Blood Smear H3

Hematology 101. Blanche P Alter, MD, MPH, FAAP Clinical Genetics Branch Division of Cancer Epidemiology and Genetics Bethesda, MD

Changes of hematological references depends on storage period and temperature conditions in rats and dogs

Two Important Statistics

Color: Gray/Yellow. 5/7/2018 L Hematology results from IDEXX VetLab In-clinic Laboratory Requisition ID: 0 Posted Final Test Result Reference Range

Interpreting the CBC. Robert Miller PA Assistant Professor of Clinical Pediatrics and Family Medicine USC Keck School of Medicine Retired

HAEMATOLOGICAL EVALUATION OF ANEMIA. Sitalakshmi S Professor and Head Department of Clinical Pathology St John s medical College, Bangalore

MEDICAL DEVICES. Aurora. Improved efficiency, outstanding donation experience

Quantitative Measurement of Emergency Biomarkers in Parallel

8.2 Principles of Quantitative Hematologic Determinations (1)

Lunar Prodigy Advance

Evaluation of the QBC Star centrifugal three-part differential haematology system

Paper ID: ART

HumaCount 5D. Outperforming 5-part Hematology System. CoreLab DX. Hematology

CONFIDENCE IN THE OUTCOMES THAT MATTER MOST TO YOU

History. n 1865 First description of reticulocytes by Erb, who. n 1881 Using supravital staining, Ehrlich demonstrated

IMAGEPOINTHX. Multispecialty Ultrasound System THE COMPLETE HARMONIC-IMAGING SOLUTION FOR MULTISPECIALTY ULTRASOUND

Continuing Education Questions

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

IMMATURE PLATELETS CLINICAL USE

May is Better Sleep Month

Performance Evaluation of NS-hema21t Automated Hematology Analyzer and Comparison of the Hematological Parameters with Sysmex XT1800i

NORMAL LABORATORY VALUES FOR CHILDREN

Customer Information Literature List Platelets

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

Advanced parameters offer faster, surer guidance to cancer care

Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing

Transcription:

XT-4000i Automated Hematology Analyzer Differentiate with the XT-4000i

Advanced Technology Solutions to Meet Your Lab s Needs Even with these challenges, the need for hematology testing has remained steady or continued to grow. Laboratories are searching for hematology analyzers that can improve productivity and efficiency while providing enhanced clinical information. Designed to be reliable and efficient, the Sysmex XT-4000i offers medium to high volume labs an automated hematology system that can truly meet and exceed their expectations. The XT-4000i streamlines your workflow by providing testing for up to 100 samples per hour, enabling rapid turnaround time. Today s Laboratory Challenges Laboratories continue to face a number of challenges. These include clinical, operational and financial issues such as: Demand for clinically relevant information Medical technologist labor shortage Increased workload Need for faster turnaround time Requirement for high reliability Limited laboratory budgets Fluorescent Flow Cytometry Yields Optimized Productivity The Sysmex XT-4000i Automated Hematology System utilizes the power of fluorescent flow cytometry and hydrodynamic focusing technologies. Using a unique, state-of-the-art, diode laser bench, Sysmex fluorescent flow cytometry provides the sensitivity needed for measuring and differentiating cell types in whole blood and body fluid samples. Fluorescent technology and hydrodynamic focusing enable the XT-4000i to consistently classify normal WBC, RBC and PLT populations from abnormal populations, thereby decreasing the number of manual interventions 1

Clinically Relevant Information Effective Red Cell Disorder Screening and Therapy Monitoring The XT-4000i System provides the panel of standard parameters for basic and reliable anemia screening and monitoring. RBCs and PLTs RBCs and PLTs are counted in a dedicated channel using Impedance or Direct Current (DC) detection method combined with hydrodynamic focusing technology. Challenges to cell counting such as coincidence or recirculation are circumvented and automatic discriminators separate the two cell populations. Even with samples at extremely low or unusually high concentrations, the Sysmex XT-4000i analyzes RBCs and PLTs with uncompromised precision and accuracy. Laser Technology Adaptive Cluster Analysis System (ACAS) WBC Differential Counting RBC and PLT Counting Non-cyanide Hemoglobin High Quality Hemoglobin (HGB) Analysis The XT-4000i utilizes the non-cyanide reagent, Sodium Laurel Sulfate Hemoglobin (SLS). The end product is a colored compound that is measured spectrophotometrically. Since hemoglobin determinations are performed from a dilution and in its own separate chamber, there is no interference from high WBC counts, lipemia or abnormal proteins. Direct Hematocrit (HCT) Measurement The cumulative pulse heights of all the RBC counts yield the HCT. This is based on the principle that the pulse height (voltage change) produced by cells passing through the aperture is proportional to cell volume. 2 WBC Differential Scattergram WBC, A Clear Differentiation The combination of side scatter (cell complexity), forward scatter (size) and fluorescence (DNA & RNA concentration) of nucleated cells provides a concise and precise image of each detected peripheral blood cell. Fluorescent technology enables the XT-4000i to reliably differentiate normal WBC populations from abnormal WBC populations. The sensitivity of the unique application of fluorescent flow cytometry gives the lab a high level of confidence in reporting accurate WBC differentials, even on critical patient samples when the WBC count is low. The Sysmex XT-4000i offers a 6-part differential, which includes an Immature Granulocyte Count (IG%, #). The IG count offers reportable, quantitative results for immature granulocytes (metamyelocytes, myelocytes and promyelocytes).

Advanced Parameters In One Comprehensive System XT-4000i Technology Provides Clinically Relevant, Reportable Parameters: Retic: Fluorescent reticulocyte count to reduce manual confirmation methods and their inherent errors RET-He: Reticulocyte Hemoglobin Content measures the incorporation of iron into the red cell to assist in anemia evaluation and management (e.g., functional iron deficiency anemia) PLT-O: Fluorescent optical platelet count and traditional impedance PLT counting to improve accuracy of very low and very high PLT counts NRBC: Fluorescent NRBC flagging Fluorescent Reticulocyte Count Fluorescent Reticulocyte Count Known as the Gold Standard reticulocyte testing parameter, the fluorescent reticulocyte count is available on the XT-4000i. Sysmex provides on-board retic testing in a dedicated channel, improving your efficiency in reporting reticulocytes 24 hours per day. Reticulocyte Channel Benefits Advanced clinical parameters Reticulocyte Hemoglobin and Immature Granulocyte Reticulocyte Hemoglobin (RET-He) Benefits Rapid, direct analysis of an earlier stage of RBC development for prompt clinical follow-up Assessment of anemia and is an established parameter used in KDOQI (Kidney Disease Outcomes Quality Initiative) guidelines for assessing the initial iron status of patients Accuracy and sensitivity in measurement of red cell production that supports effective monitoring of costly drug protocols for cell stimulation by clinicians Accurate reticulocyte % and # Improved immature reticulocyte information (IRF) for earlier diagnosis and treatment by clinicians Elimination of common interferences from Howell-Jolly bodies, Pappenheimer bodies and immature reticulocytes to avoid manual counts In addition, the Reticulocyte Hemoglobin (RET- He) is a parameter measured in the RET Channel and is used to measure the incorporation of iron into erythrocyte hemoglobin. 3

Improved Productivity & Efficiency XT-4000i Body Fluid Mode Fluorescent Optical Platelet The XT-4000i analyzer includes a body fluid specific mode. This mode provides a reportable RBC, WBC, WBC differential (polymorphonuclear and mononuclear) and a total count (TC-BF) for all common body fluid samples (CSF, synovial and serous). The analyzer applies proven impedance and fluorescent flow cytometry ensuring an accurate body fluid count. WBC Body Fluid Count MN PMN Fluorescent Optical Platelet The XT-4000i offers a Fluorescent Optical Platelet (PLT-O) in addition to the traditional impedance PLT (PLT-I) count. These dual technologies support maximizing instrument information from abnormal patient samples. Flagging associated with atypical or abnormal platelets due to increased size or fragmentation is minimized by use of the optical platelet count. Accuracy in reporting is supported by the availability of both technologies. Fluorescent Optical Platelet (PLT-O) Benefits The XT-4000i Body Fluid Count Provides Expanded sensitivity and linearity; WBC and RBC counts reportable to 3 decimal places 2-Part Differential No sample pretreatment No additional reagents No additional quality control material required An automatic background check prior to analyzing a sample The XT-4000i Body Fluid Count Benefits Improved productivity Decreased turnaround time (TAT) Decreased manual technical intervention Improved accuracy on low platelet counts Accurate counts when interferences are present, thus reducing manual intervention Automated judgment for reporting PLT-O or PLT-I through instrument settings, eliminating tech-to-tech decision variability Positive Synovial Body Fluid 4

Maximizing Uptime e-tools: Assuring Quality and Optimizing Performance SNCS TM, Sysmex Network Communications System, is proprietary software which enables fast, secure communication from your analyzer to Sysmex servers using a high-speed, outbound internet connection. This powerful tool is the instrument data link feeding a variety of innovative tools and services. Insight TM Insight is a web-based Inter-laboratory Quality Assessment Program (QAP) which allows on-demand quality control reporting with access anytime, anywhere. Meet requirements to document peer comparison data for your analyzer while eliminating manual steps. Improved Patient Care The XT-4000i offers a CBC, 6-part differential and one of the highest throughputs in the market for a mid-range analyzer. The small whole blood sample size closed mode: 150μL, open mode: 85μL can be utilized for your pediatric and oncology patient samples. The capillary mode, pre-dilute analysis mode, requiring only 40μL of whole blood, provides quality clinical data, rapidly and consistently. Results from the capillary mode include CBC and Retic counts and user-defined flagging from very low volume samples. Remote Monitoring Continuous collection and monitoring of instrument performance data is linked to our tracking and dispatch system. We monitor your instrument performance, instrument configuration settings and back-up settings continuously. Make your lab more efficient with: Unobtrusive, remote and real-time monitoring Proactive identification and follow-up of potential issues Enhanced first-time field fixes, if needed Productivity The system provides a throughput of up to 100 samples per hour, producing high-quality results rapidly for clinicians to use in diagnosis and treatment decisions. The XT-4000i can be used in conjunction with Sysmex WAM Decision Support Software for the Clinical Laboratory, which enhances sample and data workflow and improves turnaround time (TAT). Differentiate with the XT-4000i The XT-4000i offers a comprehensive clinical testing menu for both whole blood and body fluids, providing accurate, precise and sensitive results. With its rapid throughput, your clinicians receive quality results to assist in management and diagnosis of all patients. Clinically relevant information from one comprehensive system! 5

Sysmex XT-4000i Specifications Excellent Performance Reliable platform Low sample volume requirements Sysmex Network Communications System (SNCS ) remote diagnostic monitoring system supporting maximum uptime Ranked by independent third party as highest vendor for reliability for 9 consecutive years* *IMV ServiceTrak 2009 Reportable, Diagnostic Information from a Single Sample Analysis 6-partwholebloodWBCdifferential (NE + Lymph + Mono + Eo + Baso + IG) with NRBC flagging Body fluid cell count and 2-part differential Anemia evaluation parameters; Reticulocyte, IRF, and RET-He Optical and Impedance Platelet measurement capabilities Easy-to-use Intuitive software menus On-board help key for rapid troubleshooting Comprehensive quality control information Barcoded reagent management Principles & Technologies Fluorescent Flow Cytometry: WBC-Diff, IG, RET, IRF, PLT-O Hydrodynamic Focusing, Direct Current: RBC, HCT, PLT Non-cyanide, Sodium Lauryl Sulfate (SLS): HGB 27 Whole Blood Reportable Parameters WBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT (Impedance and Fluorescent Optical), NEUT%, LYMPH%, MONO%, EO%, BASO%, IG%, NEUT#, LYMPH#, MONO#, EO#, BASO#, IG#, RDW-SD, RDW-CV, MPV, RET%, RET#, IRF, RET-He 7 Body Fluid Reportable Parameters WBC-BF, RBC-BF, TC-BF, MN%, MN#, PMN%, PMN# Linearity WBC: 0 440.00 x 10 3 /µl RBC: 0 8.00 x 10 6 /µl PLT: 0 5,000 x 10 3 /µl Body Fluid Linearity WBC-BF: 0.004 10.000 X 10 3 /µl RBC-BF: 0.001 5.000 X 10 6 /µl TC-BF: 0.004 10.000 X 10 3 /µl Throughput Whole Blood Mode: 100 samples/hour Body Fluid Mode: 30 samples/hour Sample Volumes Closed mode: 150µL Open mode: 85µL Capillary mode: 40µL Data Storage (IPU: Information Processing Unit) Quality Control (Total QC Management) 10,000 samples including graphics Levey-Jennings Control Charts X-bar M file Comprehensive QC files including current and new lot feature Online Quality Assurance Program Interfaces Dimensions/Weight w x h x d [in] / [lbs] ASTM Sysmex WAM (HL7 & ASTM) Main Unit including sampler: 20.9" x 24.8" x 28.3" / 130 lbs. Pneumatic Unit: 11.0" x 15.7" x 14.0" / 37.5 lbs.

Sysmex Corporation 1-5-1 Wakinohama-Kaigandori, Chuo-ku, Kobe 651-0073, Japan Tel. +81 (78) 265-0521 Fax +81 (78) 265-0530 www.sysmex.co.jp Sysmex America, Inc. One Nelson C. White Pkwy, Mundelein, IL 60060, U.S.A. Tel. +1 (847) 996-4500 Fax +1 (847) 996-4397 www.sysmex.com/usa Sysmex Canada, Inc. 5045 Oribitor Drive, Building 9, Suite 401 Mississauga, ON, L4W 4Y4, Canada Tel. +1 (905) 366-7900 Fax +1 (905) 366-7899 www.sysmex.ca Sysmex do Brasil Indústria e Comércio Ltda Rua Joaquim Nabuco, 615 - Bairro Cidade Jardim, São José dos Pinhais Paraná Brasil CEP 83040-210 Tel. +55 (41) 2104-1314 Fax +55 (41) 2104-1300 www.sysmex.com.br Sysmex Europe GmbH Bornbarch 1, 22848, Norderstedt, Germany Tel. +49 (40) 52726-0 Fax +49 (40) 52726-100 www.sysmex-europe.com Sysmex Deutschland GmbH Bornbarch 1, 22848, Norderstedt, Germany Tel. +49 (40) 5341020 Fax +49 (40) 5232302 www.sysmex.de Sysmex UK, Ltd. Sysmex House, Garamond Drive, Wymbush Milton Keynes, Buckinghamshire, Mk8 8DF, U.K. Tel. +44 (870) 9029270 Fax +44 (870) 9029211 www.sysmex.co.uk Sysmex Asia Pacific PTE, Ltd. 2 Woodlands Sector 1, #01-06 Woodlands Spectrum, Singapore 738068, Singapore Tel. +65 (6221) 3629 Fax +65 (6221) 3687 www.sysmex-ap.com Sysmex Shanghai, Ltd. 9th Floor, Azia Center, 1233 Lujiazui Road, Shanghai, 200120, China Tel. +21 (6886) 3300 Fax +21 (6886) 3355 www.sysmex.com.cn 2011 Sysmex America Inc. All rights reserved. Document Number MKT-10-1138 04/2011 1M