Evaluation parameters and technique for classification of intraocular tumours

Similar documents
1444. Application of ultrasound spectral analysis for intraocular tissues differentiation

Characteristic Ultrasonographic Findings of Choroidal Tumors

Linear Ultrasonic Wave Propagation in Biological Tissues

Routine Quality Assurance Cookbook

Application of Phased Array Radar Theory to Ultrasonic Linear Array Medical Imaging System

Lung Tumour Detection by Applying Watershed Method

Early Detection of Lung Cancer

Outline. Brief history and principles of ophthalmic ultrasound. Types of ocular ultrasound. Examination techniques. Types of Ultrasound

A new method of sonograph lateral resolution measurement using PSF analysis of received signal

Ultrasound B-Scan for Posterior Segment Evaluation

Ultrasound Measurements and Non-destructive Testing Educational Laboratory

Enhanced Detection of Lung Cancer using Hybrid Method of Image Segmentation

ULTRASOUND IMAGING EE 472 F2018. Prof. Yasser Mostafa Kadah

Assessment of Reliability of Hamilton-Tompkins Algorithm to ECG Parameter Detection

MELANOMA OF THE CHOROID EXAMINED WITH AN ACOUSTIC BIOMICROSCOPE*

Descriptions of NDT Projects Fall 2004 October 31, 2004

Extraction of Blood Vessels and Recognition of Bifurcation Points in Retinal Fundus Image

Feasibility Evaluation of a Novel Ultrasonic Method for Prosthetic Control ECE-492/3 Senior Design Project Fall 2011

Ultrasound Evaluation of the Posterior Segment of the Eye A Ready Reckoner

Evaluation of Ultrasound Attenuation Characteristics of Human Cataract

Myofascial Pain Syndrome Trigger Point Detection based on Ultrasound Image

EXTRACT THE BREAST CANCER IN MAMMOGRAM IMAGES

ISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 2, Issue 10, April 2013

Heart Rate Calculation by Detection of R Peak

COMPUTERIZED SYSTEM DESIGN FOR THE DETECTION AND DIAGNOSIS OF LUNG NODULES IN CT IMAGES 1

A quality control program for MR-guided focused ultrasound ablation therapy

Supplementary Figure S1: Histological analysis of kainate-treated animals

Diploma of Medical Ultrasonography (DMU) Physical Principles of Ultrasound and Instrumentation Syllabus

LABVIEW based expert system for Detection of heart abnormalities

Pipeline Technology Conference 2007

ULTRASONIC ARRAY APPROACH FOR THE EVALUATION OF ELECTROFUSION JOINTS OF POLYETHYLENE GAS PIPING

Fluorescein and Indocyanine Green Videoangiography of Choroidal Melanomas

Brain Tumor Detection using Watershed Algorithm

Ultrasound in Medicine

week by week in the Training Calendar. Follow up graphics, sort, filter, merge, and split functions are also included.

Terminology Tissue Appearance

GLOBAL INNOVATION BY DESIGN

Brain Tumor Detection Using Morphological And Watershed Operators

DIGITAL IMAGE PROCESSING IN ULTRASOUND IMAGES

Cancer Cells Detection using OTSU Threshold Algorithm

1 Fundamentals. Basic Definitions and Physics Principles. Fundamentals

Gabor Wavelet Approach for Automatic Brain Tumor Detection

w. D. Jolly, F. A. Bruton, and C. Fedor

Principles of Ultrasound. Cara C. Prideaux, M.D. University of Utah PM&R Sports Medicine Fellow March 14, 2012

ULTRASOUND BLOOD FLOW IMAGING IN CAROTID ARTERIES BEFORE AND AFTER ENDARTERECTOMY

Uveal Melanoma. Protocol applies to malignant melanoma of the uvea.

An Overview of Ultrasound Testing For Lesion Detection in Human Kidney

International Journal of Advance Engineering and Research Development EARLY DETECTION OF GLAUCOMA USING EMPIRICAL WAVELET TRANSFORM

Role of B-Scan Ultrasonography in pre-operative cataract patients

CHARACTERIZATION OF ANNULAR ARRAY TRANSDUCER

What is Ultrasound? What is Ultrasound? B A. Basic Principles of Ultrasound. Basic Principles of Ultrasound. Basic Principles of Ultrasound

International Journal of Computer Sciences and Engineering. Review Paper Volume-5, Issue-12 E-ISSN:

Development of novel algorithm by combining Wavelet based Enhanced Canny edge Detection and Adaptive Filtering Method for Human Emotion Recognition

CHAPTER IV PREPROCESSING & FEATURE EXTRACTION IN ECG SIGNALS

ANALYSIS AND DETECTION OF BRAIN TUMOUR USING IMAGE PROCESSING TECHNIQUES

BMMC (UG SDE) IV SEMESTER

8/15/2011. Quantitative Ultrasound Imaging: A Historical Perspective. Motivation. Motivation & Applications. Motivation & Applications

1 Introduction. Abstract: Accurate optic disc (OD) segmentation and fovea. Keywords: optic disc segmentation, fovea detection.

The Physics of Ultrasound. The Physics of Ultrasound. Claus G. Roehrborn. Professor and Chairman. Ultrasound Physics

Hemodynamic Analysis System

Performance of phased array and conventional ultrasonic probes on the new ISO reference block

On the feasibility of speckle reduction in echocardiography using strain compounding

SPECTRAL ANALYSIS OF LIFE-THREATENING CARDIAC ARRHYTHMIAS

Detection of Abnormalities of Retina Due to Diabetic Retinopathy and Age Related Macular Degeneration Using SVM

Detecting ultrasonographic hollowness in small choroidal melanocytic tumors using 10 MHz and 20 MHz ultrasonography: a comparative study

Segmentation of Color Fundus Images of the Human Retina: Detection of the Optic Disc and the Vascular Tree Using Morphological Techniques

Diagnosis of Breast Cancer Using Ensemble of Data Mining Classification Methods

Experience Spectacular Retinal Imaging with the new NIDEK F-10 Digital Ophthalmoscope

A Review on Brain Tumor Detection in Computer Visions

Ultrasonic Testing Level I:

DIAGNOSTIC TECHNIQUE OF ABNORMALITIES IN BALL BEARINGS WITH AN ULTRASONIC METHOD

Basic Physics of Ultrasound and Knobology

NMIJ measurement service on ultrasonic field parameters available to demonstrate performance and safety of ultrasonic medical equipment

Diagnostic Ultrasound. Sutiporn Khampunnip, M.D.

Brain Tumor Detection Using Image Processing.

Semi-automatic Thyroid Area Measurement Based on Ultrasound Image

The table below shows the density and velocity of waves in two different substances. Density / kg m 3 Velocity / m s 1

Derivation of Sonograph Quality Parameters by the Use of Point Spread Function Analysis

DETECTION OF HEART ABNORMALITIES USING LABVIEW

Gene Expression Profiling has been proposed as a method of risk stratification for uveal melanoma.

A step forward full automatic analysis Silvère BARUT 1, Nicolas DOMINGUEZ 1, Jean-Noël NOIRET 2, Ivan KAMENEFF 3

Breast Cancer Prevention and Early Detection using Different Processing Techniques

Brain Tumour Detection of MR Image Using Naïve Beyer classifier and Support Vector Machine

shear wave elastography

Improved Inspection of Composite Wind Turbine Blades with Accessible Advanced Ultrasonic Phased Array Technology

An efficient method for Segmentation and Detection of Brain Tumor in MRI images

Advances in Ocular Imaging

CEA PROGRAM FOR MULTIPLE-TECHNIQUE NON DESTRUCTIVE

Ultrasonic Measurement of Aircraft Strut Hydraulic Fluid Level

Ultrasound Physics & Terminology

ANALYSIS OF MALIGNANT NEOPLASTIC USING IMAGE PROCESSING TECHNIQUES

ADVANCE ULTRASONIC INSPECTION

Technique. 92i. M. M. J. McNicholas, 2 D. P. Brophy,1 W. J. Power,3 4 and J. F. Griffin1 3

Implementation of Automatic Retina Exudates Segmentation Algorithm for Early Detection with Low Computational Time

Mammography is a most effective imaging modality in early breast cancer detection. The radiographs are searched for signs of abnormality by expert

7.1 Grading Diabetic Retinopathy

Heart Abnormality Detection Technique using PPG Signal

ULTRASOUND. OB/Gyn (Core) Ultrasound PIEZOELECTRIC EFFECT. Principles of Ultrasound Physics and Instrumentation. Nathan Pinkney, BS, CDOS

Diagnosis of Liver Tumor Using 3D Segmentation Method for Selective Internal Radiation Therapy

Controlled Cryogenic Ablation Using Ultrasonic Sensing

Transcription:

Evaluation parameters and technique for classification of intraocular tumours M. Žakauskas 1, A. Mačiulis 1, A. Kopustinskas 1, A. Paunksnis 2, D. Krivaitienė 2 1 Department of Applied Electronics, Kaunas University of Technology Studentų g. 50-327, LT-3031 Kaunas, Lithuania 2 Institute of Biomedical Research, Kaunas Medical University Eivenių g.4, LT-3007 Kaunas, Lithuania Introduction Classification and diagnosis of intraocular tumours is one of the actual problems in ophthalmology. Melanoma, metastasis and no malignant tumour are frequently observed intraocular tumours. Simply no malignant tumour in the text refers as no tumour. Melanoma is melanocytus neoplastic tumour, which may induce the secondary tumours (metastasis) to lungs, liver and bones. Melanoma commonly starts to grow in the eye posterior urea. Melanoma is the direct reason of death for each third patient. Therefore early diagnosis of this pathology is crucial for proper treatment and prognosis. Ultrasound echographic technique is widely used for visualization of intraocular tumours. Non invasiveness, informativity and user-friendliness are the main features of ultrasound technique. The brightness of ultrasound image element (pixel) depends on the distribution of acoustic impedance or tissue density. The possibility of ultrasound technique applying for classification of various tumours is based on the direct relationship between tumour tissue density distribution and its morphology. Set of publications is made on echographic characterization of intraocular tumours [1, 2, 3]. Ordinary method for analysis of echographic images is based on search and evaluation of specific parameters, statistical analysis and methods of image texture classification. A 15- year retrospective analysis of tumours classification is presented in [1]. Main echographic parameters are determined in [3]. Application of data mining technique for medical decision support is discussed in [4]. Fundamental technique for parametrisation of ultrasonic images is presented in [5]. The essence is to use the point spread function and inverse filtering technique for restoration of ultrasonic images. Further investigations are needed to show whether the use of complicated mathematical tools allows to reduce the image noises and gives a more useful information. Analysis of publications shows that the possibilities of ordinary methods for tumour classification are not exhaused. It is desirable to search for new specific parameters, based on the information about the mechanism of image element genesis, to determine interrelationship and to increase the reliability of classification. The aim of the present paper is to develop technique, to find optimal values of specified ultrasonic images parameters and investigate the system See5.0(C5.0) for classification of intraocular tumours. Method of investigation All patients have been examined with the ultrasonic diagnostic imaging system Mentor Advent, using A/B scan mode. The block diagram of the developed computerized ultrasound system for intraocular tumour image acquisition and analysis is shown in Fig.1. The focused transducer center frequency is 12,5 MHz, radius of the transducer 2,7 mm, the scan range 5 cm. The images are transmitted from video output of the ultrasound system to PC by the use of a frame grabber. Captured echographic images were analysed using numerical computation and the visualization software MATLAB. Some statistical computations were performed by using Microsoft Office Excell 2000. Echographic parameters for classification of eye tumours are obtained from ultrasonic A/B images. A-echogram presents the time (distance from transducer) function of an echo signal amplitude. B-echogram presents two dimensional distribution of an echo signal amplitude in the B-scan plane. A typical example of A/B image, obtained with above mentioned ultrasonic system is shown in Fig.2. Following parameters of intraocular tumour are defined from echographic images: height, base, shape, the level of tumour compactivity, existing complications (hemorrhages, retinal detachments), internal reflectivity (the feature to reflect ultrasound waves), internal regularity (the feature of distribution of peak amplitudes throughout the tumour), choroidal excavation. It is important to define allocation, size, complications and morphological type of an intraocular tumour. The final decision of the morphological type of the tumour was obtained after enucleating and invasive pathology investigations. Structure and geometry of eye an tumour is shown in Fig. 3. The height and the base of tumour are measured during the patient eye examination, the height and base ratio is calculated. The shape, retinal detachment and choroidal excavation were determined from B-echographic images. 48

ISSN 1392 2114 ULTRGARSAS, Nr.4(49). 2003. Intraocular tumour Ultrasound transducer Mentor Advent A/B System Frame grabber IBM compatible PC Fig. 1. Block diagram of the developed computerized ultrasound system for image acuisition and analysis Fig. 2. Typical image, obtained with the ultrasound research MENTOR Advent A/B System Others parameters were obtained by examination of A- echographic image. The amplitude of an echosignal depends on the ratio of acoustic impedances of tissue or on the ratio of densities of tissue at the given point of image. The echosignal carries a valuable information about morphology of the tissue shape, homogenity and structure. Reflectivity of the tumour is characterized by the reflection coefficient K A (%), which is calculated as a ratio of mean and maximal amplitudes of the echosignal: m 1 ui R m K = i 1 A 100%, (1) Umax Umax where u i is the i- in value of the digitized echosignal amplitude, reflected by the tumour, U max is the maximal amplitude of the echosignal, m is the number of discrete points. Physically the reflectivity coefficient indicates the continuity of the distribution mean variations of the tumour tissue density. The three level system for evaluation of discrete values of the reflectivity coefficient was chosen: high, medium, low. The regularity of an intraocular tumour tissue is characterized by the irregularity coefficient m 2 ( xi x i) i= 1 K R =, (2) L Fig.3. B-view of eye tumour (top), A echogram (below), T tumour, RD retinal detachment, CE choroidal excavation, P- height of tumour, R mean amplitude of reflected signal, B base of tumour where x i is the position (mm) in A image of the i-th peak value of the echosignal, L is the length (mm) of a tumour in A image, m is the total number of peak values in the echosignal, x = L / m is the step of a regular tissue structure. The irregularity coefficient shows the continuity of distribution of maximal variation of tumour tissue densities. Statistical data The database on 99 intraocular tumours for statistical analysis was stored in the laboratory of ophthalmology in the Institute of Biomedical Research of Kaunas Medical University Hospital during the period from 2000 to 2003. The ultrasound intraocular images database consists of 52 cases of melanoma, 8 metastasis and 39 - no tumours. The height and the base are comparable for all tumours and this is not a reliable statistically parameter for classification, but the height and base ratio characteristic of each group is statistically significant (see Fig.4). By the use of modified TNM (Tumor, Nodes, Metastasis) classification system all eye tumours are grouped accordingly to their 49

height into T1 (height no more 3,0 mm), T2 (height between 3,0 and 5,0 mm) and T3 (height more 5,0 mm) groups. The melanoma type tumours compose significant part in the T3 (65,4%) group, 13,5 % melanoma type tumours are found in the T1 group and 21,1% T2 group. In the T3 group metastasis type tumour was undetected. Metastases often belong to the T1 (50 %) or to the T2 (50%) groups. No tumour type composes a significant part in the T1 (53,9 %) group, but this type may belong approximately equally to the T2 or T3 groups - respectively 25,6% and 20,5 %. Interesting data were obtained analyzing the shape and others parameters of eye tumours. In the melanoma group mushroom (50%) and dome (48,1%) shape types are main, the flat shape type occures seldom, holey type never. In the metastasis group tumours the mushroom shape type is not observed, there often could be seen dome (37,5 %) and holey (50%) shape type, the flat type ocures seldom (12,5%). In the group of no tumours the main is the dome shape type, the flat shape type is not observed. The low (40,4%) and medium (59,6%) reflectivity coefficient is characteristic in the melanoma group. The medium 62,5%) and high (25%) reflectivity coefficient is dominating in the metastasis group. The medium (46,2%) and low (35,9%) reflectivity coefficient often can be seen in the group of no tumours. No tumour group has a low level of regularity. The low regularity tissue has 61,5% from all no tumours. In metastasis and melanoma groups is characteristic high regularity structure, it has 75% and 65,4% tumours accordingly. Choroidal excavation sometimes (18,6%) could be seen in the melanoma group, but in metastasis and no tumours groups clearly visible choroidal excavations are not found. Correlations between classification parameters for various tumour groups are different in many cases. Statistically significant correlations are shown in Table 1. 1,000 0,800 0,600 0,400 0,200 0,000 Height/Base Height/Base Height/Base Ratio Ratio Ratio Melanoma Metastasis No tumor STDEV Height/Base ratio Fig. 4. Distribution of height and base ratio in different groups Table 1. Correlation between classification parameters Control group Parameters of correlation Coefficient of correlation Melanoma Between ratio hight/base and shape 0,48 Between retinal detachment and hight 0,55 Between ratio hight/base and K R 0,39 Metastasis Between shape and K R -0,69 Between shape and ratio hight/base -0,65 Between base and choroidal excavation 0,65 Between choroidal excavation and retinal detachment -0,58 No tumour Between K R and hight 0,73 Between K R and ratio hight/base 0,45 Between reflectivity and retinal detachment -0,39 50

ISSN 1392 2114 ULTRGARSAS, Nr.4(49). 2003. Analysis of classification results The program See 5.0/C5.0 was used for classification of intraocular tumours. RuleQuest Research Corp. distributes the version of program with one limitation database for classifiers construction must be less than 400 samples. Performance of the program is based on the data mining system. Initial data with known conclusions (diagnosis) are used for the classifiers constructing. The decisions tree (see Fig.5) or classification rules are designed using these initial data. After that the classification is performed using new cases with an unknown diagnosis. Data attributes with continuous and/or digitized values can be used. Unnecessary attribute can be eliminated by a special command in parameters description file. Part of initial data or data file with unknown diagnosis can be used for investigation of classification reliability. There is possibility to determine which cases are classified inaccurately. The classifier is made using selected (decisions tree or/and classification rules) classification algorithm. Tumours in the database were analyzed in three different ways: - tumours were sorted into the malignant tumours, metastasis and no tumours; - the malignant tumours and metastasis were treated as one class, no tumours - as another class; - tumours are sorted into the malignant tumours and no tumours, the metastasis were eliminated. The influence of the irregularity coefficient threshold value was investigated for differentiation of tumors into the regular and irregular groups. Values of thethreshold were changed from 1.4 to 1.8 (see Fig. 6). The influence of reflectivity coefficient thresholds values was investigated for differentiation into the tumours with high, medium and low reflectivity as well. 35 I II III 30 25 20 15 10 5 0 1,4 1,5 1,6 1,7 1,8 Threshold Fig. 6. Investigation of influence of the irregularity coefficient threshold value on classification reliability, there: I - classification results, when were selected values of reflectivity and irregularity coefficients; II - classification results, when were eliminated aberrant cases in the database; III - classification results, when were involved only tumors with a prominence higher than 2 mm Results Fig. 5. Example of intraocular tumours classification using classifier based on decision tree Intraocular tumours were classified using four classifiers: decision tree, classification rules, corporate decision trees and corporate classification rules. Random picked 80 % of cases in databases were used for training of selected classifier and reminder 20% - for evaluation of the classifier reliability. 20 tests with each classifier with different set of intraocular tumours were preformed and after the reliability was evaluated for the selected classifier. The influence of different attributes to classification reliability was investigated. The digitized values of the reflectivity coefficient (low, medium, high) and the irregularity coefficient (regular, irregular) were used. Tumour height was eliminated as attribute in the database. In this case the reliability of classifiers had increased. Investigation results show that the best reliability is found when digitized values of reflectivity and irregularity coefficients are used. The best classification accuracy is obtained when the thresholds values of the reflectivity coefficients K A are 70% and 93% (K A <70% - low reflectivity, 70% K A 93% - medium reflectivity, K A >93% - high reflectivity) and the threshold value of the irregularity coefficient K R is 1.72 (K R 1.72 regular tumour, K R >1.72 irregular tumour). These affirmations are right when classifiers are constructed using: decision tree, classification rules and corporate classification rules. When classifiers are constructed using the corporate decision trees, the thresholds values are slightly different. After initial investigation the thresholds values of the reflectivity coefficient K A (70% and 93%) and the irregularity coefficient K R (1.72) were selected. Investigations results are presented in Table 2. Aberrant cases in the database were eliminated in order to obtain real classification results. These cases in the database probably could originate due to wrong diagnosis of physicians, inexperienced technician that made examination 51

of the patient, errors in calculation of tumours attributes (incorrect selection of A-echogram zone), low prominence of a tumour and etc. The classification results get better about 30% after 10 aberrant cases were eliminated from the tumours database (Table 2). Verbeek and Thijssen [2] proposed not to take into the account the tumors with prominence less than 2mm. 15 cases with such properties were eliminated from the tumours database. That improved reliability of the classification. After all these improvements, classification of tumours with 92% reliability was achieved (Table 2). Table 2. Results of classification reliability investigations. There cases I, II and III are explained in heading of Fig.6 the melanoma, metastasis and no tumours the melanoma and no tumours, metastasis the melanoma and no tumours, metastasis are No Classification rule ascribed as tumours eleminated I II III I II III I II III 1. Decision tree 26 15 12 28 17 10 19 2. Classification rules 29 16 13 25 15 11 20 3. Corporate decision trees 27 13 10 26 11 8 16 4. Corporate classification rules 30 13 10 22 11 8 17 Conclusions 1. Reliability of classification became higher when the attribute tumour height was eliminated. 2. The digitized values of the reflectivity coefficient (low, medium, high) and the irregularity coefficient (regular, irregular) should be used. The best reliability of classification is achieved when the thresholds values equal to 70% and 93% for the reflectivity coefficients and the threshold value equal to 1.72 for the irregularity coefficient was selected. 3. The classifier constructed using the corporate decision trees has been found the best for classification of intraocular tumors. 4. Amount of classification errors decreases to 13%, when aberrant cases in the database were eliminated. Amount of classification errors have decreased to 8%, when tumors with prominence less than mm were eliminated from the database. 5. All classification algorithms have difficulties to recognize metastasis. This can be explained with small amount cases of these kind of the tumours in database and with a small height specific to metastasis. So, it is relevant to expand the tumours database and to continue the investigations. Reference 1. Verbeek A. M., Thijssen J. M., Cuypers M. H. M. Echographic classification of intraocular tumours. Acta Ophthalmologica. 1994.. No.72. P. 416-422. 2. Verbeek A. M., Thijssen J. M., Osterveld B. J., Romijin R. L. Ultrasonic differentiation of intraocular melanomas: parameters and estimation methods. Ultrasonimaging. 1991. P. 27-55. 3. Mačiulis A., Kopustinskas A., Paunksnis A, Šebeliauskienė D. Echografinio vidinių akies auglių ir tinklainės degeneracinių pokyčių klasifikavimo parametrų analizė. Elektronika ir elektrotechnika. Kaunas: Technologija. 2002. Nr.5(40). P.76-80. 4. Jegelevičius D., Lukoševičius A., Paunksnis A., Barzdžiukas V. Application of data mining technique for diagnosis of posterior uveal melanoma. Informatica. 2002. No.4. P. 455-464. 5. Jegelevičius D., Lukoševičius A., Paunksnis A., Šebeliauskienė D. Parameterisation of ultrasonic echographic images for intraocular tumour differentiation. Ultragarsas. 2002. Nr.1. P. 50-56. M. Žakauskas, A. Mačiulis, A. Kopustinskas, A. Paunksnis Vidinių akies darinių klasifikavimo parametrų ir būdo parinkimas Reziumė Melanoma tai melanocitinis neoplastinis auglys, galintis metastazuoti į plaučius, kepenis, kaulus. Vienam iš trijų ligonių gyslainės melanoma yra tiesioginė mirties priežastis, todėl šią patologiją būtina anksti diagnozuoti ir tinkamai gydyti. KMUK Akių ligų klinikos oftalmologijos laboratorijoje atliekami diagnostiniai akių tyrimai ultragarsu A/B režimais. Tyrimo metu gauti vaizdai keičiami į kompiuterinį formatą ir išsaugomi. Vėliau šie vaizdai analizuojami matematiniais bei statistiniais metodais. Tyrimui naudojami parametrai gaunami iš ultragarsinių vaizdų. Akies dariniai skirstomi į tris klases: melanomas, metastazes ir ne auglius. Darbo metu buvo tiriama atskirų klasifikavimo parametrų įtaka klasifikavimo tikslumui. Buvo naudojamos diskretizuotos atspindžio koeficiento (aukštas, vidutinis, žemas) ir nereguliarumo koeficiento (reguliarus, nereguliarus) vertės. Surastos optimalios šių koeficientų vertės. Pateikta spaudai 2003 08 26 52