Amendment No. 2. Item No. 2 (Rfx/ Event number )

Similar documents
Commissioning and Radiobiology of the INTRABEAM System

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Slide 1. Slide 2. Slide 3. Introduction of INTRABEAM IORT. Disclosure. Contents. I have nothing to disclose.

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

EORTC Member Facility Questionnaire

IORT with mobile linacs: the Italian experience

Quality assurance in external radiotherapy

ph fax

Learning Objectives. Clinically operating proton therapy facilities. Overview of Quality Assurance in Proton Therapy. Omar Zeidan

DOSIMETRIC COMPARISION FOR RADIATION QUALITY IN HIGH ENERGY PHOTON BEAMS

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

Leila E. A. Nichol Royal Surrey County Hospital

Unrivaled, End-to-End

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

I. Equipments for external beam radiotherapy

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Implementation Guide for the DoseControl Dosimetry System

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

S. Derreumaux (IRSN) Accidents in radiation therapy in France: causes, consequences and lessons learned

Eric E. Klein, Ph.D. Chair of TG-142

A new geometric and mechanical verification device for medical LINACs

IMRT QA: Point Dose Measurements or 2D Array?

Future upcoming technologies and what audit needs to address

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Canadian Partnership for Quality Radiotherapy. Technical Quality Control Guidelines for Gamma Knife Radiosurgery. A guidance document on behalf of:

CT Quality Control Manual FAQs

Nuclear Associates

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Radiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague

Hong Kong Association of Medical Physics. Guide to Candidates

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

8/2/2017. Objectives. Disclosures. Clinical Implementation of an MR-Guided Treatment Unit

Radiochromic film dosimetry in water phantoms

Accuracy Requirements and Uncertainty Considerations in Radiation Therapy

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Data Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident

Hampton University Proton Therapy Institute

International Practice Accreditation

Indiana University Health Proton Therapy Center. Chee-Wai Cheng, Ph.D.

SunCHECK Patient Comprehensive Patient QA

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Small field diode dosimetry

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Calibration of dosimeters for small mega voltage photon fields at ARPANSA

Brachytherapy Planning and Quality Assurance w Classical implant systems and modern computerized dosimetry w Most common clinical applications w

Multilayer Gafchromic film detectors for breast skin dose determination in vivo

M. J. Maryanski, Three Dimensional BANG Polymer Gel Dosimeters AAPM'99, CE Course

Brachytherapy Planning and Quality Assurance

Technology Challenges of Commercial Medical Electron Accelerators

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

Online Care, Online Control, Online Confidence

The Journey of Cyberknife Commissioning

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

An anthropomorphic head phantom with a BANG polymer gel insert for dosimetric evaluation of IMRT treatment delivery

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Topics covered 7/21/2014. Radiation Dosimetry for Proton Therapy

Intensity Modulated RadioTherapy

Volumetric Modulated Arc Therapy - Patient Specific QA

IEC Subcommittee 62C (Equipment for Radiotherapy, Nuclear Medicine and Radiation Dosimetry): Recent and Active Projects

Assessment of Dosimetric Functions of An Equinox 100 Telecobalt Machine

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results

Dosisverifikation mit Delta 4 Discover während der Behandlung

ABSTRACTS FOR RADIOTHERAPY STANDARDS USERS MEETING. 5 th June 2007

DOELAP On-Site Assessment Requirements Checklist Page 1 of 24 Participant:

ADVANCED TECHNOLOGY CONSORTIUM (ATC) CREDENTIALING PROCEDURES FOR LUNG BRACHYTHERAPY IMPLANT PROTOCOLS

Special Procedures Rotation I/II SBRT, SRS, TBI, and TSET

Joint ICTP/IAEA Advanced School on Dosimetry in Diagnostic Radiology and its Clinical Implementation May 2009

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC)

Mania Aspradakis John Byrne Hugo Palmans John Conway Jim Warrington Karen Rosser Simon Duane

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

Albert Lisbona Medical Physics Department CLCC Nantes Atlantique a

SRS/SBRT Errors and Causes

Debate Motion. Theoretical benefits of VMAT: Real Costs of VMAT. "Arc Based Techniques Will Make Conventional IMRT Obsolete

A Snapshot on Nuclear Cardiac Imaging

Computed tomography Acceptance testing and dose measurements

Varian Edge Experience. Jinkoo Kim, Ph.D Henry Ford Health System

AbstractID: 8073 Title: Quality Assurance, Planning and Clinical Results for Gamma Knife Radiosurgery S. Goetsch, Ph.D. Page 1 Seattle, WA May 2008

Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology

Quality Assurance in Stereotactic. Radiotherapy. Swedish Cancer Institute Seattle, WA

Special techniques overview : IORT

Implementation of the 2012 ACR CT QC Manual in a Community Hospital Setting BRUCE E. HASSELQUIST, PH.D., DABR, DABSNM ASPIRUS WAUSAU HOSPITAL

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Delivery Quality Assurance with a High Resolution Liquid Filled Ion Chamber Array for Robotic Radiosurgery

GAMMA DOSE DISTRIBUTION EVALUATION OF XiO TREATMENT PLANNING SYSTEM FOR STATIC FIELD IMRT, USING AAPM TG-119

GAMMA DOSE DISTRIBUTION EVALUATION OF XiO TREATMENT PLANNING SYSTEM FOR STATIC FIELD IMRT, USING AAPM TG-119

RaySafe X2 Solo DENT. X-ray meter for dental applications

CyBio Felix Your Automated Application Starts Here

Transcription:

Amendment 2 Sub: Amendment to the Document 06.12.2018 Ref.: Notice Inviting Bid ref. HITES/PCD/NCI-AIIMS/36/18-19 dated 26.09.2018 read with its Amendment no. 1 dated 19.11.18 The following changes have been authorised and are being incorporated in the above referred Document. SECTION - VII TECHNICAL SPECIFICATION AND GENERAL POINTS A. TECHNICAL SPECIFICATION: Item 2 (Rfx/ Event number 3000003420) IORT Machine (Electron Based) Sl. Document 1 Point 1.9 page 62 2 Point 1.11 Page 62 3 Point 1.15 Page 62 4 Point 1.21 page 63 The Dose per pulse shall be a value such that quality assurance (QA) procedures are simple to implement and are similar to those used in conventional radiotherapy treatment. Dual (primary and backup) dosimetry system for measuring radiation output, based on vented ion chambers with automatic pressure and temperature compensation The treatment head of the equipment should have at least 5 degrees of freedom Range of motion and treatment flexibility:- The treatment head shall have the ability to move in 5 axes with following minimum ranges:- Gantry: +/- 45 degrees Tilt: +20/-10 degrees Vertical: 30 cm total range Dual (primary and backup) dosimetry system for measuring radiation output, based on vented ion chambers with temperature compensation. The equipment should have at least 5 degrees of freedom The treatment equipment should have 5 degree of motion for facilitating treatment HITES/PCD/NCI-AIIMS/36/Amdt.2/18-19 dated 06.12.2018 Page 1 of 6

Sl. Document 5 Point 2.1 6 Point 2.3 7 Point 2.5 8 Point 2.6 9 Point 3.8 10 Point 3.9 11 Point 5, Page 64 HLL Infra Tech Services Ltd. This software should be able to execute stability QA;report, print, and store machine calibration results, perform quality checks and calculate the number of monitor units (MU) required to administer a prescribed dose at a specified depth with all energies and all types of applicators. Dose planning with the capability to mix different electron energies The software shall be DICOM 3.0 Compliant and HL 7 compliant. The software shall track and record daily QA sessions including: - Beam energy and output statistics - Functionality Tests - Interlocks It should have at least two 19" or more TFT flat screen LCD colour monitor for display of 1024 x 1024 matrix or more. Computer CPU systems should be running on a high-end workstation platform with UNIX/LINUX/ Window of latest configuration. RAM size must be at least 8 GB or better Dosimetry Equipment 1. Vendor must provide relevant QA device, Phantom and dosimetry equipment required for QA and dosimetric calibration. a) PDA :- Photo Diode Array: 5 diodes positioned orthogonally to each other to measure the radiation of the miniaturized accelerator. The objective of this test is to assure the isotropy of the emitted beam. b) PAICH :- Probe Adjuster Ion Chamber Holder: the output can be checked. An ion chamber is mounted onto the probe adjuster The software shall track and record daily QA sessions. The system should have 19" or more TFT flat screen LCD colour monitor for display of 1024 x 1024 matrix or more. Computer CPU systems should be running on a high-end workstation platform with latest configuration. RAM size must be at least 8 GB or better Dosimetry Equipment Vendor must provide relevant QA device, Phantom and dosimetry equipment required as follows; (i) Absolute Dosimetry Systems: Vendor should provide 3D mini water phantom. One water-proof cylinderical chamber and parallel plate chamber with suitable eletrometer for output measurements as per IAEA TRS- 398 protocol (ii) Relative dosimetry Systems: Vendor should provide radiochromic films (two pockets of two different sizes) suitable for HITES/PCD/NCI-AIIMS/36/Amdt.2/18-19 dated 06.12.2018 Page 2 of 6

Sl. Document in such a way that the ion chamber window sits right above the tip of the miniaturized accelerator to enable for treatment planning until a coefficient has been computed IORT depth dose measurements with suitable latest model flatbed film scanner system in addition to the system-specific dosimetric equipments and QA tools. (iii) One solid water phantom for daily QA checks. 12 Point 9.1 Page 65 The system should be integrated and connected to CT-Simulator, MR/PET-CT, PET-MRI and Treatment planning station of Radiotherapy department, etc. (iv) one specially designed water equivalant cylidercical phantom which is insertable with electron applicator for output factor measurements. DELETED Item 3 (Rfx/ Event number 3000003421) IORT Machine (X-Ray Based) Sl. document 1 Point 1.1 2 Point 1.2 3 Pont 1.5 The machine should be dedicated Mobile Photon beam LINAC. It should have a point-source type x- ray emission, Spherical dose distribution around the isocentre of the miniaturized accelerator, Steep dose gradient (approx. 1/r3) in water (soft tissue equivalent).positional accuracy of delivered dose +/- 1 mm. The LINAC should have mounted on mobile stand/mounting for LINAC having multiple axis movement. The equipment should have positional accuracy of delivered dose +/- 1 mm The machine should be dedicated Mobile X-ray based IORT system. It should have a point-source type x-ray emission, Spherical dose distribution around the isocentre of the miniaturized accelerator, Steep dose gradient (approx. 1/r3) in water (soft tissue equivalent).positional accuracy of delivered dose +/- 1 mm. The system should have mounted on mobile stand and easily movable from room to room facilitating all treatments. Either equipment positioing or emitting source point accuracy should be of + 1 mm HITES/PCD/NCI-AIIMS/36/Amdt.2/18-19 dated 06.12.2018 Page 3 of 6

4 Point 1.7 5 Point 1.9 6 Point 1.11 page 66 7 Clause. 5.1 Page No 67 8 Clause. 7.5 Page No 68 9 Clause. 8.1 Page No 68 10 BOQ Column D Page No 69 HLL Infra Tech Services Ltd. It should have inbuilt internal radiation monitor to enable real time measurement of dose delivered. High precision water phantom with < 100 μm accuracy for independent dose verification should be included in the offer. The equipment should be in use globally for wide range of indications (Breast Cancer, Endometrial Cancer, Lung Cancer, Soft tissue Sarcoma, Skin cancer etc.). Equipment standard and safety should comply with the national regulatory AERB guidelines and offered model should have AERB type approval and NOC. Factory trained service engineer/application specialists should be available in Delhi-NCR to look after the installation and maintenance of the system without patient treatment interruption The system should be integrated and connected to CT-Simulator, MRI/PET-CT, PET-MRI and Treatment planning station of Radiotherapy department, etc. Number of x-ray tube required for treatment of 1000 Patients (for Bid ranking only)* It should have either inbuilt internal radiation monitor or any alternative mechanism to ensure the precise dose delivery. The System should come with the proper QA phantom to allow the site tech personnel to execute the proper dosimetric verification tests. The equipment should be in use globally for wide range of indications for IORT. The model offered by the vendor may be of either AERB type approval/noc approved or AERB type approval/ NOCpending. Factory trained service engineer/application specialists should be available in Delhi-NCR to look after the installation and maintenance of the system without patient treatment interruption. Supporting certificate should be furnished. The system should be integrated and connected to imaging system and Treatment planning system. Number of x-ray tube required for treatment of 1000 Patients (for Bid ranking only)*. If the system uses, disposable x-ray tube along with required consumables for treatment, the following number of X-ray tubes with cooling tube and other consumable as below. Breast-500, Gynecological-300 and skin-200. Existing Specification (Ref: Point 4, Page 67): 4. Vendor must provide relevant QA device, Phantom and dosimetry equipment required for QA and dosimetric calibration. HITES/PCD/NCI-AIIMS/36/Amdt.2/18-19 dated 06.12.2018 Page 4 of 6

: Dosimetry, QA and Safety Measurement Equipments: Vendor must provide relevant dosimetry equipments and QA devices, Phantom required for QA and dosimetric calibration as follows; 1. The system which uses non-disposable x-ray tube should provide the following dosimetry and QA equipments. (i) Absolute Dosimetry Systems: Vendor should provide specially designed water phantom with soft x-ray small volume parallel plate chamber with suitable holder and eletrometer for output measurements as per AAPMTG-61 Protocol. (ii) Relative dosimetry Systems: Vendor should provide radiochromic films (two pockets of two different sizes) suitable for IORT depth dose, profiles measurements along with suitable latest model flatbed film scanner system in addition to the system-specific dosimetric equipments/qa tools. 2. The system which uses disposable x-ray tube should provide the following dosimetry and QA equipments: (i) Absolute Dosimetry Systems: vendor should provide in-built or standalone calibrated Well-Type chamber with suitable electrometer for source strength or output calibration as per AAPM TG-43 protocol (ii) Relative dosimetry Systems: Vendor should provide radiochromic films (two pockets of two different sizes) suitable for IORT depth dose measurements with suitable latest model flatbed film scanner system in addition to the system-specific dosimetric equipments/qa tools. 3. Vendor should provide the mobile micro MOSFET wireless dosimetry system with suitable software and hardware reader for invivo dose verfication during IORT treatement. 4. Vendor should provide the latest model one survey meter suitable for measuring lowenergy x-rays and its contamination leakage measurements. 5. Vendor should provide System specific periodic quality assurance phantom and devices suitable for their systems. HITES/PCD/NCI-AIIMS/36/Amdt.2/18-19 dated 06.12.2018 Page 5 of 6

Item 4 (Rfx/ Event number 3000003422) Mobile CT Scanner for IORT document Para 1.8 Page 70 The system should have an Image reconstruction speed of at least 16 images per sec or more The system should have an Image reconstruction speed of at least 24 images per sec or more. All other contents of the Document including terms & conditions remain unaltered. HITES/PCD/NCI-AIIMS/36/Amdt.2/18-19 dated 06.12.2018 Page 6 of 6