IJopRD INTRODUCTION ABSTRACT MATERIALS AND METHODS /jp-journals

Similar documents
Evaluation of Bond Strength of Silicone and Acrylic Resin Based Resilient Denture Liners Over A Period of Storage in Water.

An evaluation of the hardness of flexible Denture Base Resins

Comparison of Flexural Strength of two Provisional Materials Used In Fixed Prosthodontics -An in Vitro Study.

Original Article MATERIALS AND METHODS INTRODUCTION

Effect of different denture cleanser solutions on some mechanical and physical properties of nylon and acrylic denture base materials

Transverse Strength of Reinforced Denture Base Resin with Metal Wire and E-Glass Fibers

Comparison of Water Conditioning Effects on Hardness and Dimensional Stability of Methyl Methacrylate and Polyamide Denture Base Materials

Reinforcing Heat-cured Poly-methyl-methacrylate Resins using Fibers of Glass, Polyaramid, and Nylon: An in vitro Study

Department of Prosthodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand

Study to evaluate the Effect of Silane Treatment and Three Different Woven Fiber Reinforcement on Mechanical Properties of a Denture Base Resin

Bending strengths and hardness of autopolymerized acrylic resin

An Obturator With A Soft Touch: A Case Report

Effect of Thickness and Recycling on Transverse Strength of Relined Acrylic Resin Denture

Flexural and fatigue strengths of denture base resin

ISSN (Online) ISSN (Print) Mangalore, Karnataka, India. *Corresponding author Dr. Shilpa.S. Dandekeri

FRACTURE STRENGTH OF PALATAL DENTURE BASE CONSTRUCTED FROM DIFFERENT ACRYLIC DENTURE BASE MATERIALS

/jp-journals Evaluation of Impact Strength of Conventionally Heat Cured and High Impact Heat Cured Poly Methyl

In vitro Assessment of Clasps of Cobalt-Chromium and Nickel-titanium Alloys in Removable Prosthesis

Original Research. Absorption of soft lining materials Kumar SK et al

JCDP. Original Research ABSTRACT INTRODUCTION

Aim of this study is to analyse the flexural strength of resin denture base which is incorporated with carbon nano

Comparison of Mechanical Strength of Palatal Denture Base using Four Mesh Designs on /jp-journals

The effect of glass flakes reinforcement on the surface hardness and surface roughness of heat-cured poly (methyl methacrylate) denture base material

Comparison of fiber reinforcement placed at different locations of pontic in interim fixed partial denture to prevent fracture: An in vitro study

Effect of Household Denture Cleansers on Color Stability

COMPARISION OF IMPACT STRENGTH IN THREE DIFFERENT TYPES OF DENTURE BASE RESINS AN IN-VITRO STUDY

Bond Strength of Composite Resin Luting Cements to Fiber-reinforced Composite Root Canal Post

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

1. RPD Acrylic portions = denture teeth (DT), denture base (DB) (and veneering)

Flexural Strength of Three Denture Base Materials in Different Curing Procedures

Available online at ISSN No:

ABSTRACT. Anil K Gujjari, Vishrut M Bhatnagar, Ravi M Basavaraju

Poly(methyl methacrylate) (PMMA) with a small

SOLUBILITY OF DIFFERENT SOFT LINING MATERIALS IN DISTILLED WATER, ARTIFICIAL SALIVA AND DENTURE DISINFECTANT SOLUTION

The effect of addition of untreated and oxygen plasma treated polypropylene fibers on some properties of heat cured acrylic resin

ISO 1567 INTERNATIONAL STANDARD. Dentistry Denture base polymers. Art dentaire Polymères pour base de prothèses dentaires. Third edition

The Effect of Using Modified Flask on the Porosity of Processed Heat- Cure Acrylic Resin

Artic Posteriors 30 U 30 L 32 U 32 L 30 U 30 L 32 U 32 L 30 U 30 L 32 U 32 L. Jump to Product Item Numbers

An Evaluation on the Flexural Strength of Heat Cure Polymethyl methacrylate Denture Base Resin with and without Reinforcement of Polyethylene Fiber

Original Research. The Effect of temperature on the strength of luting cements Patil SG et al

TECHNICAL DATASHEET POUR TYPE ACRYLIC RESIN PDFTPT-082

M-PM DISC DIGITAL PRECISION BRILLIANT AESTHETIC

EFFECT OF THERMOCYCLING ON THE TENSILE AND SHEAR BOND STRENGTHS OF THREE SOFT LINERS TO A DENTURE BASE RESIN

Flexural Strength of Poly Propylene Fiber Reinforced PMMA

The Effect of Outdoor Weathering on Color Stability of Silicone and Acrylic Resin, Pigments A Comparative Evaluation: An in vitro Study

Original Research. Anumeha Narwal 1 1 Dept. of Prosthodontics, Punjab Government Dental College, Amritsar, Punjab, India.

Howard E. Strassler, DMD University of Maryland School of Dentistry

Handling efficiency of autopolymerized resin applied using the brush-on technique

Evaluation the Effect of Different Surface Treatment on Shear Bond Strength between Composite Increments (An in vitro study)

IvoBase Material. The innovative denture base material. Tissue friendly, tough, predosed

In vitro evaluation of the flexural properties of All-on-Four provisional fixed denture base resin partially reinforced with fibers

Annotation to the lesson 21 Topic: Methods of provisory crowns fabrication. Chair-side technique. Evaluation of

Dental Research Journal

Palatal Vault Depth Influence on the Flexural Strength of Two Heat Cure Acrylic Denture Base Resins: An in vitro Study

Flexural properties and impact strength of denture base polymer reinforced with woven glass fibers

Bonding strength of autopolymerizing resin to nylon denture base polymer

The effect of a plastic-wrapped LED light curing unit and curing distance variances on diametral tensile strength of composite resin

Surabhi Somkuwar, Sunil Kumar Mishra 1, Benaiffer Agrawal 1, Rupali Choure

Evaluation of Impact and Transverse Strength of Denture Bases Repaired with Nano Reinforced Resin

ISO INTERNATIONAL STANDARD. Dentistry Base polymers Part 1: Denture base polymers

DURATEMP Temporary Crown & Bridge Material. Temrex Corporation October 2009

Shear Bond Strength of Acrylic Teeth to Acrylic Denture Base after Different Surface Conditioning Methods

A Survey on the Current Trends in the Use of Different Core Buildup Materials and Luting Agents in General Dental Practice

AvaDent Bonding Procedure Results: The AvaDent bond exceeds ADA requirements.

Evaluate the Effect of Commercially Available Denture Cleansers on Surface Hardness and Roughness of Denture Liners at Various Time Intervals

ISSN X (Print) Research Article. *Corresponding author Dr. Hemal Agrawal

Original Research. Strength of Denture Relining Materials...Lau M et al

Self-Adhesive (SA) Cement VS Dual-Cured (DC) Resin Cement

Short Glass Fiber-reinforced Composite with a Semi-interpenetrating Polymer Network Matrix for Temporary Crowns and Bridges

Short Fiber Reinforced Composite: The Effect of Fiber Length and Volume Fraction

RPD ACRYLIC MATERIALS

Comparison between Acetal Resin and Cobalt-Chromium. Removable Partial Denture Clasp Retention: An in vitro Study.

Evaluation of Acetal Resin and Cobalt Chromium Clasp Deformation and Fatigue Resistance in Removable Partial Denture Clasps - An In Vitro Study

Effect of Fiber Post and Stainless Steel Wire on the Flexural Strength of Repaired Denture Base Acrylic Resin

The effect of aging on some physical properties of temporary soft denture liners

BEGO PMMA Multicolor Processing information for CAD/CAM-produced restorations

NextDent, the leading manufacturer of dental materials for 3D printing

The Effect of Microwave Disinfection on the Dimensional Change of Acrylic Resins.

Journal of IMAB - Annual Proceeding (Scientific Papers) 2016, vol. 22, issue 3

Mechanical Properties of Surface-Charged Poly(Methyl Methacrylate) as Denture Resins

Effects of relining materials on the flexural strength of relined thermoplastic denture base resins

Leading Dental Materials for 3D Printing. NextDent.com

Increasing the Interfacial Adhesion in Poly(methyl methacrylate)/carbon Fibre Composites by Laser Surface Treatment

AN INJECTION MOULDING DEVICE, IMPROVING THE EXISTING INJECTION SYSTEM FOR ACRYLIC DENTURE FABRICATION

Some flexural properties of a nylon denture base polymer

Changes in the Transverse Strength of Heat-Cured Acrylic Denture Base by Using Diodes Laser as Surface Treatment

Repair of fractured denture bases is an

Flexural Strength of Polymethyl Methacrylate Repaired with Fiberglass

Original Research. The combination of mechanical and chemical methods seems to be the best choice for denture cleaning. 1,7-9

Natural Tooth Pontic using Fiber-reinforced Composite for Immediate Tooth Replacement

Color stability and colorant effect on maxillofacial elastomers. Part I: Colorant effect on physical properties

Evaluation of Destaining Property of Denture Cleansers on Heat-cured Denture Base Resins using Common Indian Food Stains

Effect of Probiotics on Candidal Adherence on Different Denture Base Resins in Maxillofacial Patients

The effect of autoclave processing on some properties of heat cured denture base material

Effect of Surface Treatments and Adhesive Materials on the Shear Bond Strength of Artificial Denture Teeth to Denture Base Resins

Questions & Answers For Dentists Ultaire AKP. High-Performance Polymer Removable Partial Dentures

QUARTZ SPLINT. Our fiber expertise is your strength TM.

The Influence of Some Dentin Primers on Calcium Hydroxide Lining Cement

allinone... unbelievable? But true! Picture: Dr. Thano Kristallis

rigidity of polymer, icrease thermal and wear resistances and decrease water sorption and solubility.

Transcription:

IJopRD Swapnil Parlani et al RESEARCH ARTICLE 10.5005/jp-journals-10019-1204 Evaluation of Flexural Modulus of Flexible Denture Base Material kept in Water, Denture Cleanser, Artificial Saliva, and Open Air for Different Time Intervals: An in vitro Study 1 Swapnil Parlani, 2 Benaiffer Agarwal, 3 Anurag Malaiya, 4 Swati Singh, 5 Sunil K Mishra ABSTRACT Aim: This was an in vitro study done to evaluate the change in flexural modulus of flexible denture base material kept in water, denture cleanser, artificial saliva, and open air for different time intervals. Materials and methods: The experimental design included four main groups, with each group having three subgroups. A total of 120 specimens were fabricated with each group containing 30 specimens; these four groups, based on duration in the storage condition, were further subdivided into three groups. Group A1: 15 days, group A2: 30 days, and group A3: 60 days. Results: Flexural modulus of flexible denture in 15 days was found to be highest with denture-cleansing tablet (1246.52 ± 8.69 MPa) and lowest in water (1170.54 ± 7.35 MPa). Flexural modulus of flexible denture in 30 days was found to be highest with open air (1282.94 ± 8.35 MPa) and lowest in denturecleansing tablet (1145.60 ± 5.34 MPa). Flexural modulus of flexible denture in 60 days was found to be highest with open air (1360.34 ± 8.02 MPa) and lowest in denture-cleansing tablet (1120.43 ± 6.34 MPa). Conclusion: According to our study, flexibility of nylon denture base material decreases when kept in open air and water for prolonged period. Initially, flexibility of nylon denture base material increases in denture-cleansing tablet and in artificial saliva, and later flexibility decreased in the first month, then there was not much effect. The best medium for storage of flexible denture was found to be artificial saliva. Keywords: Artificial saliva, Denture cleanser, Flexural modulus, Polyamide, Polymethyl methacrylate. How to cite this article: Parlani S, Agarwal B, Malaiya A, Singh S, Mishra SK. Evaluation of Flexural Modulus of Flexible Denture Base Material kept in Water, Denture Cleanser, Artificial Saliva, and Open Air for Different Time Intervals: An in vitro Study. Int J Prosthodont Restor Dent 2018;8(2):54-58. Source of support: Nil Conflict of interest: None 54 1,2,5 Professor, 3,4 Postgraduate Student 1-5 Department of Prosthodontics and Crown and Bridge, People s College of Dental Sciences & Research Centre, Bhopal, Madhya Pradesh, India Corresponding Author: Anurag Malaiya, Postgraduate Student, Department of Prosthodontics and Crown and Bridge People s College of Dental Sciences & Research Centre, Bhopal Madhya Pradesh, India, e-mail: malaiya.anurag@gmail.com INTRODUCTION In the majority of population, the loss of teeth is a matter of concern and their replacement is done by removable or fixed artificial substitutes. Removable prostheses are fabricated using polymethylmethacrylate (PMMA) resin and nylon-based plastic (polyamide). 1 Due to various advantages, such as low toxicity, adequate strength, low water sorption and solubility, excellent esthetic value, easy to repair, and a simple processing technique, PMMA has been the most popular material used for denture fabrication since its introduction in 1937. Regardless, it has issues of polymerization shrinkage, weak flexural strength, lower impact strength, and low fatigue resistance. 2 In this manner, improvised thermoplastic nylon can be a useful alternative to PMMA in extraordinary conditions where higher flexibility, higher resistance to flexural fatigue, and higher impact strength are required. 3 Also, it was asserted that nylon materials have different focal point advantages including higher elasticity than common heat polymerizing resins, toxicological safety for patients with monomer allergy and metal allergy, and use of heat molding instead of chemical polymerization to control the polymerization shrinkage and its related deformation. 2 The denture of patient is exposed to different conditions in the oral cavity. These agents may affect the mechanical property of flexible denture base material. There might be changes in the modulus of elasticity of flexible denture base when they are exposed to denture cleansers, artificial saliva and kept in open air (not immersed in water), but it has not been studied and investigated till now. 4 So, this study aims to evaluate the effect of different agents on the flexural strength and flexural modulus of thermoplastic nylon denture base material for different time durations (15, 30, and 60 days). MATERIALS AND METHODS The study was undertaken in the Department of Prosthodontics with supporting technical assistance from Central Institute of Plastics Engineering and Technology and Centre for Scientific Research and Development.

IJOPRD Evaluation of Flexural Modulus of Flexible Denture Base Material Table 1: Specimen distribution among groups Group Category Number of samples I Denture cleanser (Clinsodent) 30 II Artificial saliva 30 III Open air 30 IV Water 30 The experimental design included four main groups, with each group having three subgroups. A total of 120 samples were fabricated with each group containing 30 samples (Table 1); further, based on duration in the storage condition, these four groups were further subdivided into three groups. Group A1: 15 days, group A2: 30 days, and group A3: 60 days (Flow Chart 1). SAMPLE FABRICATION AND STORAGE For standardization, the rectangular metal dies were made for the fabrication of sample with dimensions of 65 10 2.5 mm according to the American Dental Association specification number 12 for denture base polymers. The rectangular samples were fabricated using nylon co-polyamide resin (Lucitone FRS Dental Resin, Dentsply India Pvt. Ltd, Haryana, India) with injection molding technique (Dentsply, Milford, USA). The specimens were stored for 15, 30, and 60 days (Fig. 1) in different storage media. Flexural modulus of flexible denture base material was calculated using Universal Instron testing machine (Instron Corp., Canton, MA) at a crosshead speed of 1.8 mm/min (Fig. 2). Thickness and width of each sample were measured with the help of digital Vernier caliper. The samples were placed on jigs that were 50 mm apart (L) and then loaded at the center until fracture occurred. The peak load (fracture load) was recorded and tabulated as: S = 3PL/2bd 2 S = Flexural strength (N/mm 2 ), Flow Chart 1: Specimen distribution among groups Fig. 1: Sixty-day sample kept in different solutions Fig. 2: Flexural strength testing using universal testing machine International Journal of Prosthodontics and Restorative Dentistry, April-June 2018;8(2):54-58 55

Swapnil Parlani et al P = Load at fracture, L = Distance between jig support, b = Specimen width, d = Specimen thickness. Statistical Analysis Data were entered in Microsoft Excel 2016 for Windows. Mean, standard deviation (SD), minimum, and maximum values of flexural modulus of flexible denture base material in different agents at different time intervals were calculated. Shapiro Wilk test, two-way analysis of variance (ANOVA) and least significant difference (LSD) post hoc test was applied for pair-wise comparison. Data analysis was performed using version 21.0 of the Statistical Package for the Social Sciences, (IBM Corporation, Armonk, New York, USA). RESULTS The mean flexural modulus among groups I, II, III, and IV at three different time periods is presented in Table 2 and Graph 1. Table 2: Two way ANOVA for comparison of flexural modulus of flexible denture base material in different agents at different time intervals Flexural modulus at different time intervals (MPa) 15 days 30 days 60 days Agents Mean ± SD Min Max Mean ± SD Min Max Mean ± SD Min Max F ratio p-value Artificial 1083.83 ± 6.65 1076.03 1094.05 1223.04 ± 7.47 1213.86 1233.95 1239.21 ± 7.11 1227.31 1246.49 994.849 <0.001 saliva Water 1170.54 ± 7.35 1159.99 1181.10 1244.90 ± 5.60 1236.40 1252.40 1323.81 ± 9.52 1309.72 1337.91 Denturecleansing 1246.52 ± 8.69 1233.19 1259.90 1145.60 ± 5.34 1140.07 1158.43 1120.43 ± 6.34 1110.43 1128.98 tablet Open air 1210.04 ± 7.14 1200.09 1219.98 1282.94 ± 8.35 1269.39 1296.49 1360.34 ± 8.02 1345.73 1374.95 p-value < 0.05 was considered statistically significant 56 Graph 1: Comparison of flexural modulus of flexible denture base material in different agents at different time intervals

IJOPRD Evaluation of Flexural Modulus of Flexible Denture Base Material Table 3: Pairwise comparison via LSD post hoc test Days Medium 15 days Denture-cleansing tablet > Open air > Water > Artificial saliva 30 days Open air > Water > Artificial saliva > Denturecleansing tablet 60 days Open air > Water > Artificial saliva > Denturecleansing tablet ter Flexural modulus of flexible denture in 15 days was found to be highest with denture-cleansing tablet (1246.52 ± 8.69) and lowest in artificial saliva (1083.83 ± 6.65). Flexural modulus of flexible denture in 30 days was found to be highest with open air (1282.94 ± 8.35) and lowest in denture-cleansing tablet (1145.60 ± 5.34). Flexural modulus of flexible denture in 60 days was found to be highest with open air (1360.34 ± 8.02) and lowest in denture-cleansing tablet (1120.43 ± 6.34). Shapiro Wilk test showed that flexural modulus values followed normal distribution. The interaction effect of agents and time intervals was significant on flexural modulus [F (6,108) = 994.849, p < 0.001]. The LSD post hoc test (Table 3) done for pair-wise comparison showed best mean of flexural modulus for denturecleansing tablet in 15 days followed by open air, water, and least is for artificial saliva. In 30 and 60 days best mean of flexural modulus was found for open air, water, artificial saliva and least was for denture-cleansing tablets. DISCUSSION The purpose of this study was to know the effect of different storage media on the mechanical properties of flexible denture base material. When not disinfected, nylon exhibited the lowest flexural modulus of 1714 MPa, while the disinfected specimens had a value of 1937 MPa. The low flexural modulus exhibited by nylon means that it is less rigid than the conventional PMMA polymers. This is not surprising, as it is indicated in certain clinical situations where flexibility is desired. 5 Nylon is advanced as a denture base material in the light of the premise of its flexibility, which enables it to engage certain degree of undercuts for retention without these undercuts being blocked. 6 At the same time, nylon has also been claimed to be a good alternative in denture patients who have sensitivity or allergy to methyl methacrylate monomer. Polyamide did not have aromatic ring in the structure. In this manner, it is theorized that the infiltration of water particles into the polymer structure impacted the flexural modulus. 7 Polyamide had a tendency to have characteristically high water sorption values. This phenomenon is clarified by the water absorption happening among the molecular chains because of the high hydrophilicity of the numerous amide bonds forming the main chains of the polyamide resin. 8 Water sorption relies upon the level of hydrophobicity and porosity of the material. In clinical use, resin denture base materials are susceptible to water sorption and solubility when immersed in an aqueous medium, such as saliva, nasal secretion, and water or cleansing agents. When immersed in such solutions, plasticizers and other soluble components may leach out over extended periods while water or saliva is being absorbed. The loss of plasticizer may cause a decreased percentage of elongation and increased hardness values. Absorbed water has a detrimental effect on the physical and mechanical properties of the resin denture base. 9 According to our study, flexibility of nylon denture base material decreases when kept in open air and water for prolonged period. In the study done by Takabayashi, 10 water sorption of two of the tried polyamide materials (Valplast and Flexite Supreme) met International Organization for Standardization standards (32 gm/mm 3 ); yet, Lucitone FRS uncovered the most astounding water sorption because of the more prominent level of hydrophilic attributes supported by the contact edge estimations. It is suspected that the higher the amide aggregate focus, the more noteworthy the water sorption. In this way, it has been proposed that the amide group concentration, in the polyamide type denture base materials, could be acclimated to a level as low as that in popular industrial materials, such as nylon 6 or 66. Denture cleansers are most commonly utilized by denture wearers for cleaning, but cleanser may have harmful effect on the plastic or metal component of the denture, so the dental practitioner must be able to recommend a denture cleanser that is effective, non-deteriorative to denture base material, and safe for persistent utilize. 11 According to our study, flexibility of nylon denture base material increases in denture-cleansing tablet. Result of the study shows that highest flexural modulus was at 15 days and lowest at 60 days. There was an adverse effect of the prepared denture cleansers which contain isopropyl alcohol on indentation hardness and flexural strength; it decreased both these properties and so, it is advised not to use it with nylon denture because it decreased its flexibility on prolonged immersion 12. Commercially available Lacalut dent, which is an oxygenating denture cleanser, had no adverse effects on polymers used, so it is safe to use. 11 According to the result, flexibility in artificial saliva decreased in first month, then there was not much effect, and so, it can be used as storage medium for nylon denture base, as flexibility of material is maintained for longevity of prosthesis. CONCLUSION Flexible denture bases are mainly indicated in clinical cases with areas in oral cavity having severe hard and soft International Journal of Prosthodontics and Restorative Dentistry, April-June 2018;8(2):54-58 57

Swapnil Parlani et al tissue undercuts. In such areas, flexibility of denture bases is a prime requisite for easy placement and removal of denture bases. So, to maintain the flexibility of prosthesis, a suitable storage medium is required. For storage we use open air, water, denture cleanser, and artificial saliva. The result of present study shows that flexibility in artificial saliva decreased in the first month, then there was not much effect, so it can be used by the patient as storage medium for nylon denture base, as flexibility of material is maintained for longevity of prosthesis. REFERENCES 1. Shah VR, Shah DN, Chauhan CJ, Doshi PJ, Kumar A. Evaluation of flexural strength and color stability of different denture base materials including flexible material after using different denture cleansers. J Indian Prosthodont Soc 2015 Oct-Dec; 15(4):367-373. 2. Vojdani M, Giti R. Polyamide as a denture base material: a literature review. J Dent (Shiraz) 2015 Mar;16(Suppl 1):1-9. 3. Kohli S, Bhatia S. Polyamides in dentistry. Int J Sci Study 2013 Apr-Jun;1(1):20-25. 4. Peracini A, Davi LR, de Queiroz Ribeiro N, de Souza RF, Lovato da Silva CH, Paranhos HF. Effect of denture cleansers on physical properties of heat-polymerized acrylic resin. J Prosthodont Res 2010 Apr;54(2):78-83. 5. Ali IL, Yunus N, Abu-Hassan MI. Hardness, flexural strength, and flexural modulus comparisons of three differently cured denture base systems. J Prosthodont 2008 Oct;17(7):545-549. 6. John J, Gangadhar SA, Shah I. Flexural strength of heatpolymerized polymethyl methacrylate denture resin reinforced with glass, aramid, or nylon fibers. J Prosthet Dent 2001 Oct;86(4):424-427. 7. Galav A, Deogade SC, Mantri S, Sumathi K, Galav S. Effect of water storage on the flexural strength of heat-cured denture base resin reinforced with stick (s) glass fibers. Contemp Clin Dent 2017 Apr-Jun;8(2):264-271. 8. Nguyen LG, Kopperud HM, Øilo M. Water sorption and solubility of polyamide denture base materials. Acta Biomater Odontol Scand 2017 May;3(1):47-52. 9. Barsby MJ. A denture base resin with low water absorption. J Dent 1992 Aug;20(4):240-244. 10. Takabayashi Y. Characteristics of denture thermoplastic resins for non-metal clasp dentures. Dent Mater J 2010 Aug;29(4): 353-361. 11. Salman M, Saleem S. Effect of different denture cleanser solutions on some mechanical and physical properties of nylon and acrylic denture base materials. J Baghdad Coll Dent 2011 Jan;23:19-24. 12. Porwal A, Khandelwal M, Punia V, Sharma V. Effect of denture cleansers on color stability, surface roughness, and hardness of different denture base resins. J Indian Prosthodont Soc 2017 Jan-Mar;17(1):61-67. 58