ANALYSIS OF CARNAUBA WAX ON BPX5

Similar documents
HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography

HC-75 Calcium Form. 305 x 7.8 mm HC-75 Calcium Form (P/N 79436)

Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

A comparison study of the analysis of volatile organic acids and fatty acids

Column Selection for the Analysis of Fatty Acid Methyl Esters Application

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Oils and Fats Analysis

Analysis of FAMEs Using Cold EI GC/MS for Enhanced Molecular Ion Selectivity

Lutein Esters from Tagetes Erecta

Technical Report. Sugar and Sterol Analysis in Human Body Fluids on a True Dual Column GCMS System. 1. Summary. 2. Introduction

Sucrose Esters of Fatty Acids

Interested in conducting your own webinar?

Off-flavour Analysis in Food Using a Simple and Rapid SPME-GC/TQMS Method with Dedicated Off-flavour Database

Fatty Acid Methylation Kits

INTERNATIONAL OLIVE COUNCIL

SUCROSE OLIGOESTERS TYPE I

Fatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens

Rapid Separation of Fatty Acid Methyl Esters

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Lipid Analysis. Andréina Laffargue, IRD CRYMCEPT Montpellier workshop, October 17th Introduction to lipid structures

Fast and Accurate Method for Total 4-Desmethyl Sterol(s) Content in Spreads, Fat-Blends, and Raw Materials

VOLUNTARY MONOGRAPH. Council for Responsible Nutrition March 2006

IDENTIFICATION AND CONTROLOFRESIDUALSOLVENTS Identification and control of residual solvents EUROPEAN PHARMACOPOEIA 6.

Improving the Analysis of 37 Fatty Acid Methyl Esters

Comprehensive analysis of FAMEs, fatty acids, and triglycerides. Agilent J&W GC columns for food nutrition testing

ISO INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of individual and total sterols contents Gas chromatographic method

ISOMALT. Chemical formula 6-O-alpha-D-Glucopyranosyl-D-sorbitol: C 12 H 24 O 11 1-O-alpha-D-Glucopyranosyl-D-mannitol dihydrate: C 12 H 24 O 11 2H 2 O

Determination of Triglycerides and Waxes in Food Products Using Cool On-Column Injection and the MET- Biodiesel Capillary Column

NEW! 200 m GC Columns for Detailed Analysis of cis/trans FAME Isomers

Forensic Analysis of Blood Alcohol Concentration

GC/MS BATCH NUMBER: C90106

Rancidity Development in Macadamia Kernels As Determined by Head-space Hexanal Concentration. Aijun Yang and Cameron McConchie September 2009

The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample

Automated Sample Preparation for FAME Analysis in Edible Oils Using an Agilent 7696A Sample Prep WorkBench

Chromatography Vacuum Ultraviolet Spectroscopy

CORESTA RECOMMENDED METHOD N 8

GC/MS BATCH NUMBER: C90110

Highly Reproducible Detailed cis/trans FAMEs Analysis Ensured by New Optimized Rt-2560 Column Manufacturing and Application-Specific QC Test

Customer : Comments and Conclusions : Daniel Dantin - Laboratory director

NUTRITIONAL COMPONENTS OF SUPERCRITICAL CARBON DIOXIDE EXTRACTED WHEAT GERM OIL

EUROPEAN COMMISSION. Standing Committee on Plants, Animals, Food and Feed Section Animal Nutrition 23 MAY MAY 2016 AGENDA

MULTIDIMENSIONALE SCHEIDINGEN IN DE GAS- EN VLOEISTOF CHROMATOGRAFIE

Forensic Chemistry: Differentiation of Olive Oil and Sunflower Oil by GCxGC-TOFMS and Determination of Fraudulent Material.

Analysis of the fatty acids from Periploca sepium by GC-MS and GC-FID

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

AS Application Note 1602

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Trans Fat Determination in the Industrially Processed Edible Oils By Transmission FT-IR Spectroscopy By

ANALYSIS OF -HYDROXYBUTYRATE (GHB) AND -BUTYROLACTONE (GBL) IN LIQUIDS PERFORMED AT NATIONAL LABORATORY OF FORENSIC SCIENCE (SKL), SWEDEN

Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases

Rapidly Analyze a Wide Range of Glycol Ethers by GC-MS Using the New Rxi -1301Sil MS Column

METHOD OF ANALYSIS DETERMINATION OF THE COMPOSITION AND CONTENT OF STEROLS AND TRITERPENE DIALCOHOLS BY CAPILLARY COLUMN GAS CHROMATOGRAPHY

DETERMINATION OF COMPOSITION OF TRIACYLGLYCEROLS AND COMPOSITION AND CONTENT OF DI-ACYLGLYCEROLS BY CAPILLARY GAS CHROMATOGRAPHY, IN VEGETABLE OILS

Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016.

Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package

Investigating GCxGC separations using selective column chemistry and compound derivatization pairings for common metabolomics chemical compounds

E17 ETHYLCELLULOSE. Revision 3 Stage 4

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Supplementary Information

A MODIFICATION OF GAS CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF FATTY ACID COMPOSITION OF MILK FAT

Esters. What intermolecular forces do you think esters have? δ + CH 3

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

CORESTA Recommended Method No. 84

Unequalled durability against water elution. % tr

Koji URAKAMI,*,a Chiaki KOBAYASHI, a Yoshihiko MIYAZAKI, a Koji NISHIJIMA, a Yoshinobu YOSHIMURA, a and Keiji HASHIMOTO b

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

Analyze Dietary Fatty Acids, Sterols, and Lignans with an Agilent J&W DB-5ms UI Column

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

METHOD OF ANALYSIS DETERMINATION OF THE COMPOSITION AND CONTENT OF STEROLS BY CAPILLARY-COLUMN GAS CHROMATOGRAPHY

DIRECT EXTRACTION OF BENZODIAZEPINE METABOLITE WITH SUPERCRITICAL FLUID FROM WHOLE BLOOD

Innovations in Large Volume Injection

REPORT of ANALYSIS OF PESTICIDE RESIDUES. in SOFT DRINK SAMPLES sent by DIRECTORATE GENERAL OF HEALTH SERVICES, NEW DELHI to CFL, Mysore

A Rapid Method for Detection of Drugs of Abuse in Blood Samples Using the Thermal Separation Probe and the 5975T LTM GC/MS

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Variation in amino acid and lipid composition of latent fingerprints

Free Fatty Acids Test Standard

(Non-legislative acts) REGULATIONS

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

Free Fatty Acids Test Standard

Charles S. McEnally* and Lisa D. Pfefferle. Department of Chemical Engineering and Center for Combustion Studies, Yale University, New Haven

3-MCPD esters in edible oils: analytical aspects

Thermo Scientific Dionex CarboPac MA1 Column

Direct Analysis of Lipophilic Antioxidants of Olive Oils using Bicontinuous Microemulsions

SEDEX 90LT Presentation

β-carotene-rich Extract From Dunaliella Salina

Gas chromatography columns and accessories

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

4. CARBON AND ITS COMPOUND

DECISION OF THE EEA JOINT COMMITTEE No 120/2017. of 7 July amending Annex I (Veterinary and phytosanitary matters) to the EEA Agreement

Fatty acid profile analysis: Grape Seed Oil Sample Set Two ( )

CORESTA RECOMMENDED METHOD NÄ 9

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Evaluation of a New Ionic Liquid Stationary Phase with PEG Like Selectivity

Improving the Analysis of Fatty Acid Methyl Esters Using Automated Sample Preparation Techniques

CAPILLARY COLUMNS: 007-1

Real Time and In Situ Monitoring of the Crystallization of Palm Oil-based Products using Focused Beam Reflectance Measurement (FBRM)

Fast determination of residual glycerol and glycerides in biodiesel by SFC/MS using the Agilent 1260 Infinity Analytical SFC System

Metabolomics Strategies

Transcription:

FOO 01 - FOOD ANALYSIS OF CARNAUBA WAX ON BPX5 CARNAUBA WAX Column Part No.: 054118 Phase: BPX5, 0.25 µm film 12 m x 0.32 mm ID Initial Temp: 100 C, 2 min Rate: 10 C/min Final Temp: Detector: Sensitivity: Injection Mode: 350 C, 20 min FID 40 x 10-12 AFS On Column H2, 10 psi. Notes: The high temperature capability of the BPX5 made this analysis reproducible. On-column injection is recommended to reduce discrimination of high molecular weight compounds. 1. C26 alkanol 2. C28 alkanol 3. C30 alkanol 4. C32 alkanol 5. C46 ester 6. C48 ester 7. C50 ester 8. C52 ester 9. C54 ester 10. C56 ester 11. C60 ester 12. C62 ester 13. C64 ester 15. C66 ester FOO 01 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 02 - FOOD ANALYSIS OF FOOD ADDITIVES ANTIMICROBIALS ON BP5 FOOD ADDITIVES - ANTIMICROBIALS Column Part No.: 054186 Phase: BP5, 0.5 µm film 25 m x 0.32 mm ID Initial Temp: 160 C, 0 min Rate: 15 C/min Final Temp: Detector: Sensitivity: Injection Mode: 280 C, 0 min FID 256 x 10-12 AFS Split 1. Methyl Paraben 2. Ethyl Paraben 3. Propyl Paraben 4. Butyl Paraben 5. Heptyl Paraben FOO 02 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 03 - FOOD ANALYSIS OF SCOTCH WHISKY ON BP20 SCOTCH WHISKY Column Part No.: 054447 Phase: BP20, 1.0 µm film 12 m x 0.53 mm ID Initial Temp: 55 C, 3 min Rate: 10 C/min Final Temp: Detector: Sensitivity: Injection Mode: 120 C, 0 min FID 128 x 10-12 AFS Split 1. Acetaldehyde 2. Ethyl Acetate 3. Methanol 4. Ethanol 5. Propan-1-ol 6. 2-Methylpropan-1-ol 7. 2-Methylbutan-1-ol + 3-Methylbutan-1-ol FOO 03 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 04 - FOOD ANALYSIS OF 13 SUGAR COMPONENT ALDITOL ACETATE MIXTURE ON BPX70 13 Component Alditol Acetate Mixture Column Part No.: 054622 Phase: BPX70, 0.25 µm film 30 m x 0.25 mm I.D. Initial Temp.: 190 C, 1 min. Program Rate: 3 C/min. Final Temp: 260 C, 10min. He, 50 kpa Detector: MS (Electron Impact Ionisation, Ionisation Potential 70 ev) Scan 100 m/z to 350 m/z in 0.3 s. Injection Mode: Split 50:1 Notes: BPX70 column, though a very polar phase, is compatible with GC/MS systems 1. Erythritol 2. 2-Deoxy-ribitol 3. Rhamnitol 4. Fucitol 5. Ribitol 6. Arabinitol 7. Xylitol 8. 2-Deoxy-glucitol 9. Allitol 10. Mannitol 11. Galacitol 12. Glucitol 13. Myo-inositol FOO 04 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 05 - FOOD ARABINOGALACTAN PROTEIN FROM PLANT CELL SUSPENSION CULTURE ON BPX70 ARABINOGALACTAN PROTEIN FROM PLANT CELL SUSPENSION CULTURE Column Part No.: 054622 Phase: BPX70, 0.25 µm film 30 m x 0.25 mm I.D. Initial Temp.: 190 C, 1 min. Program Rate: 3 C/min. Final Temp: Detector: Injection Mode: 260 C, 10min. He, 50 kpa HP5790MSD. Split Notes: BPX70 is the only polar column commercially available suitable for GC/MS application 1. 2,3,4,6-O-methyl glucitol 2. 2,4,6-O- methyl glucitol 3. 3,4,6-O-methyl glucitol 4. 2,3,4-O-methyl glucitol 5. 2,3,6-O-methyl glucitol 6. 2,6-O-methyl glucitol 7. 4,6-O-methyl glucitol 8. 3,6-O-methyl glucitol 9. 2,4-O-methyl glucitol 10. 2,3-O-methyl glucitol 11. 3,4-O-methyl glucitol 12. 6-O-methyl glucitol 13. 2-O-methyl glucitol 14. 3-O-methyl glucitol 15. 4-O-methyl glucitol 16. glucitol hexa-acetate 17. myo-inositol hexa-acetate FOO 05 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 06 - FOOD ANALYSIS OF SUGAR ALDITOL ACETATES ON A 12M BPX70 COLUMN ALDITOL ACETATES Column Part No.: 054605 Phase: BPX70, 0.25 µm film 12 m x 0.32 mm I.D. Temp.: Isothermal at 210 C H 2 Detector: F.I.D. Sensitivity: 16 x 10-12 AFS Injection Mode: Split, 50:1 Notes: The polarity of BPX70 enables rapid analysis of Alditol Acetates. BPX70 is the only highly polar column compatible with GC/MS 1. Erythritol 2. Deoxyribitol 3. Rhamnitol 4. Fucitol 5. Ribitol 6. Arabinitol 7. Xylitol 8. Deoxyglucitol 9. Allitol 10. Mannitol 11. Galactitol 12. Glucitol 13. Inositol FOO 06 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 07 - FOOD ANALYSIS OF MONO, DI, & TRIGLYCERIDES ON BPX5 ANALYSIS OF MONO, Di & TRIGLYCERIDES Column Part No.: 054118 Phase: BPX5, 0.25 µm 12 m x 0.32 mm I.D. Initial Temp.: 80 C, 1 min Rate: Final Temp.: Detector: Injector Mode: Carrier: 10 C/min 365 C, 10 min FID On-Column (SGE OCI-5) He, 10 psi Notes: BPX5 column allows this analysis to be performed on a routine basis. On-column injection is recommended to ensure no loss of high MW fraction. FOO 07 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 08 - FOOD TRIGLYCERIDE DISTRIBUTION IN MILK FAT ON BPX5 TRIGLYCERIDE DISTRIBUTION IN MILK FAT Column Part No.: 054133 Phase: BPX5, 0.25 µm 12 m x 0.53 mm I.D. Initial Temp.: 100 C, 0.5 min. Rate 1: 50 C/min. Temp.: 280 C Rate 2: 10 C/min. Final Temp: 360 C, 5 min. He, 6 psi Injection Mode: On-column (OCI-5) Injection Volume: 1 µl PEAK TRIGLYCERIDE COMPOSITION No. CARBON No. (%) 1 T24 0.12 2 T26 0.41 3 T28 0.64 4 T30 1.30 5 T32 2.61 6 T34 5.99 7 T36 11.22 8 T38 13.49 9 T40 10.55 10 T42 7.36 11 T44 6.90 12 T46 7.10 13 T48 8.41 14 T50 10.49 15 T52 9.34 16 T54 3.95 17 T56 0.22 FOO 08 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 09 - FOOD ANALYSIS OF TRIGLYCERIDE DISTRIBUTION IN LARD ON BPX5 TRIGLYCERIDE DISTRIBUTION IN LARD Column Part No.: 054133 Phase: BPX5, 0.25 µm 12 m x 0.53 mm I.D. Initial Temp.: 100 C, 0.5 min. Rate 1: 50 C/min. Notes: Recommended Operating Conditions Carrier Gas Velocity (Helium): 100-150 cm/sec approx., Pressure: 5-7 psi Sample Concentration Temp.: 280 C Rate 2: 10 C/min. Final Temp: 360 C, 5 min. He, 6 psi Injection Mode: On-column (OCI-5) Injection Volume: 1 µl On-column: - Olive oil, lard and cocoa butter : 0.5-1.0 mg/ml (0.05-0.1 % solution) Injection Temp.: 100 C, solution dissolved in iso-octane Peak TRIGLYCERIDE COMPOSITION No. CARBON No. (%) 1 T44 0.21 2 T46 0.46 3 T48 2.66 4 T50 17.08 5 T52 62.93 6 T54 15.61 7 T56 1.25 FOO 09 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 10 - FOOD STANDARD MIXTURE OF TRIGLYCERIDES ON BPX5 STANDARD MIXTURE OF TRIGLYCERIDES Column Part No.: 054133 Phase: BPX5, 0.25 µm 12 m x 0.53 mm I.D. Initial Temp.: 100 C, 0.5 min. Rate 1: 50 C/min. Temp.: 280 C Rate 2: 10 C/min. Final Temp: 360 C, 5 min. He, 6 psi Injection Mode: On-column (OCI-5) Injection Volume: 1 µl Notes: This analysis requires on-column injection to provide quantitative results Peak TRIGLYCERIDE No. CARBON No. 1 T36 2 T38 3 T40 4 T42 5 T44 6 T46 7 T48 8 T50 9 T52 10 T54 FOO 10 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 11 - FOOD ANALYSIS OF TRIGLYCERIDE DISTRIBUTION IN COCOA BUTTER ON BPX5 Column Part No.: 054133 Phase: BPX5, 0.25 µm 12 m x 0.53 mm I.D. Initial Temp.: 100 C, 0.5 min Rate 1: 50 C/min Temp: 280 C Rate 2: 10 C/min Final Temp.: 360 C, 5 min Detector: FID Injector Mode: On-Column (SGE OCI-5) Carrier: He, 6 psi Injection Volume: 1 µl Notes: Recommended Operating Conditions Carrier Gas Velocity (Helium): 100-150 cm/sec approx., Pressure: 5-7 psi Sample Concentration On-column: - cocoa butter: 0.5-1.0 mg/ml (0.05-0.1 % solution) Injection Temp.: 100 C, solution dissolved in iso-octane Peak TRIGLYCERIDE COMPOSITION No. CARBON No. (%) 1 T48 0.27 2 T50 17.58 3 T52 45.49 4 T54 34.37 5 T56 2.01 6 T58 0.25 FOO 11 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 12 - FOOD TRIGLYCERIDE DISTRIBUTION IN OLIVE OIL ON BPX5 Column Part No.: 054133 Phase: BPX5, 0.25 µm 12 m x 0.53 mm I.D. Initial Temp.: 100 C, 0.5 min Rate 1: 50 C/min Temp: 280 C Notes: Recommended Operating Conditions Carrier Gas Velocity (Helium): 100-150 cm/sec approx., Pressure: 5-7 psi Sample Concentration Rate 2: 10 C/min Final Temp.: 360 C, 5 min Detector: FID Injector Mode: On-Column (SGE OCI-5) Carrier: He, 6 psi Injection Volume: 1µL On-column: - Olive oil : 0.5-1.0 mg/ml (0.05-0.1 % solution) Injection Temp.: 100 C, solution dissolved in iso-octane Peak TRIGLYCERIDE COMPOSITION No. CARBON No. (%) 1 T48 0.08 2 T50 7.27 3 T52 36.54 4 T54 54.47 5 T56 1.45 6 T58 0.17 FOO 12 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 13 - FOOD ANALYSIS OF PARTIALLY METHYLATED GLUCOSE ON BPX70 PARTIALLY METHYLATED GLUCOSE Column Part No.: 054602 Phase: BPX70, 0.25 µm film 25 m x 0.22 mm I.D. Initial Temp.: 185 C, 1min. Program Rate: 3 C/min. Final Temp: Detector: Injection Mode: 260 C, 10min. He, 50 kpa MS (Electron Impact Ionisation, Ionisation Potential 70eV) Scan 100m/z to 350 m/z in 0.3s. Split Notes: BPX70 is compatible with GC/MS systems. FOO 13 Copyright SGE Analytical Science Pty Ltd July 2008 1. 2,3,4-O-methyl rhamnitol 2. 2,3,5-O- methyl arabinitol (f) 3. 2,3,4-O-methyl arabinitol (p) 4. 3,5-O-methyl arabinitol 5. 2,3,4,6-O-methyl glucitol 6. 2,5-O-methyl arabinitol 7. 2,3,4,6-O-methyl galactitol 8. 2,3-O-methyl arabinitol 9. 2,4,6-O-methyl galactitol 10. 2-O-methyl arabinitol 11. 2,3,6-O-methyl glucitol 12. 2,3,4-O-methyl galactitol 13. arabinitol hexa-acetate 14. xylitol hexa-acetate 15. 2,3,4,6-O-methyl galactitol 16. 2-O-methyl galactitol 17. 4-O-methyl galactitol 18. galactitol hexa-acetate 19. glucitol hexa-acetate 20. myo-inositol hexa-acetate

FOO 14 - FOOD ANALYSIS OF BUTTER FAT ON HT5 ANALYSIS OF BUTTER FAT Column Part No.: 054661 Phase: HT5, 0.1 µm 6 m x 0.53 mm I.D. (Aluminum Clad) Initial Temp.: 200 C, 0 min Program Rate: Final Temp.: Detector: Sensitivity: Injection Mode: 10 C/min 370 C, 5 min H 2, 2 psi F.I.D. 32 x 10-12 AFS On-column FOO 14 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 15 - FOOD FREE BASE AND METAL COMPLEXED PORPHYRINS ANALYSIS ON HT5 FREE BASE AND METAL COMPLEXED PORPHYRINS Column Part No.: 054651 Phase: HT5, 0.1 µm 12 m x 0.32 mm I.D. (Aluminium Clad) Initial Temp.: 60 C, 0 min Notes: The high temperature nature of HT5 makes it the best column available for this analysis Program Rate 1: 20 C/min to 300 C Program Rate 2: 10 C/min Final Temp.: 430 C, 5 min H 2, 15 psi Detector: F.I.D. Sensitivity: 16 x 10-12 AFS Injection Mode: On-column 1. Porphyrin M=TiO 2. Porphyrin M=Cu 3. Porphyrin M=VO 4. Porphyrin M=Pd FOO 15 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 16 - FOOD ANALYSIS OF TRIGLYCERIDE STANDARDS ON HT5 ANALYSIS OF TRIGLYCERIDE STANDARDS Column Part No.: 054661 Phase: HT5, 0.1 µm 6 m x 0.53 mm I.D. (Aluminium Clad) Initial Temp.: 60 C, 0 min Program Rate: 10 C/min Final Temp.: Detector: Sensitivity: Injection Mode: 370 C, 5 min H 2, 2 psi F.I.D. 32 x 10-12 AFS On-column Notes: For the analysis of triglycerides, on-column injection is recommended. Temperatures above 380 C are not recommended as triglycerides can degrade. FOO 16 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 17 - FOOD THE ANALYSIS OF PLANT STEROLS ISOTHERMALLY ON BPX35 Column Part No.: 054714 Phase: BPX35, 0.25 µm 30 m x 0.22 mm ID Temp.: 310 C Detector: FID, 360 C Injector Mode: Split, 100:1 He, 20 psi Injection Volume: 1 µl 1. Caprosterol 2. Cholesterol 3. Cholestanol 4. Brassicasterol 5. Desmosterol 6. Ergosterol 7. Campasterol 8. Stigmasterol 9. Unknown 10. beta-sitosterol 11. Lanosterol FOO 17 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 18 - FOOD THE ANALYSIS OF PLANT STEROLS WITH TEMPERATURE PROGRAM ON BPX35 Column Part No.: 054701 Phase: BPX35, 0.25 µm 30 m x 0.25 mm ID Initial Temp.: 280 C, 1 min Rate 1: 4 C/min Final Temp.: 350, 5 min Detector: FID, 360 C Injector Mode: Split, 100:1 He, 20 psi Injection Volume: 1 µl 1. Caprosterol 2. Cholesterol 3. Cholestanol 4. Brassicasterol 5. Desmosterol 6. Ergosterol 7. Campasterol 8. Stigmasterol 9. Unknown 10. beta-sitosterol 11. Lanosterol FOO 18 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 19 - FOOD PLANT STEROLS ISOTHERMALLY ON BPX5 Column Part No.: 054142 Phase: BPX5, 0.25 µm 30 m x 0.22 mm ID Initial Temp.: 310 C Detector: FID, 360 C Injector Mode: Split, 100:1 He, 20 psi Injection Volume: 1 µl 1. Coprosterol 2. Cholesterol 3. Cholestanol 4. Desmesterol 5. Brassicasterol 6. Ergosterol 7. Campasterol 8. Stigmasterol 9. Unknown 10. beta-sitosterol 11. Lanosterol FOO 19 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 20 - FOOD PLANT STEROLS WITH TEMPERATURE PROGRAM ON BPX5 Column Part No.: 054142 Phase: BPX5, 0.25 µm 30 m x 0.22 mm ID Initial Temp.: 280 C, 1min Rate 1: 4 C/min Final Temp.: 350 C, 5min Detector: FID, 360 C Injector Mode: Split 100:1 He, 20 psi Injection Volume: 1 µl 1. Coprosterol 2. Cholesterol 3. Cholestanol 4. Desmosterol 5. Brassicasterol 6. Ergosterol 7. Campasterol 8. Stigmasterol 9. Unknown 10. beta-sitosterol 11. Lanosterol FOO 20 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 21 - FOOD PLANT STEROLS ON A 0.53 MM ID BPX5 COLUMN Column Part No.: 054148 Phase: BPX5, 1.0 µm 30 m x 0.53 mm ID Initial Temp.: 320 C Detector: FID, 360 C Injector Mode: split 100:1 He, 3 psi Injection Volume: 1 µl 1. Coprosterol 2. Cholesterol 3. Cholestanol 4. Desmosterol 5. Brassicasterol 6. Ergosterol 7. Campasterol 8. Stigmasterol 9. Unknown 10. beta-sitosterol 11. Lanosterol FOO 21 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 22 - FOOD COD OIL FATTY ACIDS (UNDERIVATISED) ON BP21 Column Part No.: 054468 Phase: BP21, 0.25 µm 25 m x 0.32 mm ID Initial Temp.: 70 C, 0.5 min Rate 1: 6 C/min Final Temp.: 260 C, 10 min Detector: FID, 280 C Injector Mode: Split, 50:1 He, 15 psi Injection Volume: 1 µl Injection Temp: 280 C 1. C14:0 2. C16:0 3. C16:1 4. C18:0 5. C18:1 6. C18:2 7. C18:3 8. C20:0 9. C22:0 10. C24:O Int. 1. 3-Methylbutanoic Acid Int. 2. Octanoic Acid FOO 22 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 23 - FOOD FREE FATTY ACID ANALYSIS ON BP21 Column Part No.: 054474 Phase: BP21, 0.5 µm Film 25 m x 0.53 mm ID Initial Temp.: 90 C, 1min Rate 1: 8 C/min Final Temp.: 160 C Detector: FID, 300 C Injector Mode: Split, 100:1 He, 5 ml/min Injection Volume: 1 µl 1. Acetic Acid 2. Propionic Acid 3. Isobutyric Acid 4. Butyric Acid 5. Isovaleric Acid 6. Valeric Acid 7. Unknown 8. Isocaproic Acid FOO 23 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 24 - FOOD ANALYSIS OF WINE ON BP20 Column Part No.: 054442 Phase: BP20, 1.0 µm 25 m x 0.32 mm ID Initial Temp.: 40 C, 2 min Rate 1: 5 C/min Temp 2: 50 C Rate 2: 15 C/min Final Temp.: 190 C H 2, 6 psi Injection Mode: 2 µl 1. Acetaldehyde 2. Ethyl Acetate 3. Methanol 4. Isopropanol 5. Ethanol 6. Propanol 7. Isobutanol 8. Isoamyl Alcohol 9. Acetic Acid 10. Unknown FOO 24 Copyright SGE Analytical Science Pty Ltd July 2008

FOO 25 - FOOD TOCOPHEROL ISOMER MIXTURE ON BPX5 Column Part No.: 054144 Phase: BPX5, 0.25 µm 15 m x 0.32 mm ID Initial Temp.: 70 C, 1 min Rate 1: 25 C/min Temp 2: 280 C Rate 2: 5 C/min Final Temp.: 330 C, 5 min He, 7 psi Detector: F.I.D., 340 C Injector Mode: Cool on-column (OCI-5) Injection Volume: 0.5 µl FOO 25 Copyright SGE Analytical Science Pty Ltd July 2008