» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL QUATTROCONE QUATTROCONE30. IPS Implant systems

Similar documents
» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL MICROCONE. IPS Implant systems

» Prosthetic Options by MEDENTiKA «

» QuattroFix treatment concept by MEDENTIKA «

Pilot guided surgery

For technical assistance: Tel Working time: 8.30 am pm

MICROCONE. IPS Implant Systems

High-end solution STEP-BY-STEP USER GUIDE

» MEDENTIKA PreFace Abutments

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE

» Passion IMPLANT PICK-UP. for Precision « MPS Multi Platform Systems. Closed tray

NEODENT GUIDED SURGERY

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Guided surgery manual

straumann Guided surgery Access to the Digital Experience

Straumann Guided Adapter. Basic information on. the Straumann Guided Adapter

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Implant System MAKE IT SIMPLE

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

LCP Medial Distal Tibia Plate, without Tab. The Low Profile Anatomic Fixation System with Angular Stability and Optimal Screw Orientation.

Basic Information on Straumann Guided Surgery. Straumann Dental Implant System

SURGICAL PROCEDURES FOR ROXOLID IMPLANTS

TITANIUM BASES CAD/CAM FOR CROWN AND BRIDGE RESTORATIONS CAD/CAM PROSTHETICS ON CAMLOG AND CONELOG IMPLANTS

TABLE OF CONTENTS P. 4-5 P. 6-7 P. 8-9 P P P P

Correction System. Surgical Technique

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Patella Planing System

Astra Tech Implant System. Manual and product catalog. Guided surgery. Computer guided implant treatment with the Astra Tech Implant System EV

isy indications and techniques

Technique Guide. 3.5 mm LCP Low Bend Medial Distal Tibia Plates. Part of the Synthes locking compression plate (LCP) system.

Technique Guide. Compact 2.0 LOCK Mandible. The locking system for the mandible.

Correction System. Surgical Technique

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

TSLP Thoracolumbar Spine Locking Plate

Guidance for. implant removal. Straumann Dental Implant System

A complete surgical kit for Premium and Shelta systems

RibFix Blu. Thoracic Fixation System

GLENOID SURGICAL TECHNIQUE

Guided surgery with NobelParallel Conical Connection Product overview

ORTH easy. The Complete System for Cortical Anchorage. OrthoEasy Pins

ACETABULAR CUP SURGICAL TECHNIQUE

SICvantage max Swiss Cross Technology

PROXIMAL TIBIAL PLATE

NARROW DIAMETER implant

GMI. MONOLITH implant system. Surgical procedures guide

Clinical Evaluation Surgical Technique

GenXT. NextGenerationImplantology. Product Catalogue 2014

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Mandible External Fixator II. Provides treatment for fractures of the maxillofacial area.

NARROW DIAMETER implant

TRI + Digital Solutions DENTAL WINGS MANUAL

NEW NEW. An Extended Solution for Narrow Ridges

The REAL Mini Implant

A complete surgical kit for Premium and Shelta systems

Guided Surgery System. Place implants with greater confidence. hahnimplant.com

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

Locator retained mandibular complete prosthesis (isy Implant System)

Trefoil Procedure manual

Surgical Technique. Cannulated Angled Blade Plate 3.5 and 4.5, 90

FLH183 04/08. Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales CF31 3XA, United Kingdom. Tel. +44 (0) Fax: +44 (0)

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

Distal Cut First Femoral Preparation

Instructions for Use DENTAL IMPLANTS

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

GUIDED SURGERY TOOL KIT (GSTK) & MASTER SLEEVES

» For multi-unit restorations -

Technique Guide. SureLock Distal Targeting Device. C-arm guided targeting for trochanteric fixation nail.

User Manual Complete Prosthetic Kit (CPK)

A self-tapping internal hex. implant by MAKE IT SIMPLE

AxSOS Locking Plate System

Integra. DigiFuse Cannulated Intramedullary Fusion System SURGICAL TECHNIQUE

2.0 mm Mandible Locking Plate System

Guided immediate loading implant surgery planned with Implant Studio D.D.S. Jae-min, Lee

Osteotomy System. The reference lines on the plate help facilitate the creation of the osteotomy, when a free hand cut is preferred.

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

GMI FRONTIER implant system. Surgical procedures guide

Technique Guide Hammertoe Correction System

Fixed Restoration for Atrophic Ridges

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

EasyLineImplant. Guided Surgery

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

DOUBLE/TRIPLE PELVIC OSTEOTOMY PLATES For Treating Coxofemoral Joint Instability and Subluxation in Immature Dogs

Cochlear Baha Attract Surgery. Aurélie Dewael Education Manager Cochlear Academy EMEA

MICROCONE. IPS Implant Systems

LCP Low Bend Medial Distal Tibia Plates 3.5 mm. Anatomic plates with low profile head for intra- and extraarticular fractures.

Product Catalog. Since 1985» Simple. Predictable. Profitable.

GUIDED SURGERY TECHNIQUE

Bone Level. Surgical Guideline. Dental Implant System

Thoracolumbar Spine Locking Plate (TSLP) System. A low-profile plating system for anterior stabilization of the thoracic and lumbar spine.

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

Cost-effective immediate restoration in the anterior region of the mandible (isy by CAMLOG)

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

Biomimetic Product catalogue

Technique Guide. LCP Proximal Femoral Hook Plate 4.5/5.0. Part of the LCP Periarticular Plating System.

The Versatile Polyaxial Solution for the Universal Spine Systems. USS II Polyaxial. Surgical Technique

The intelligent system.

TRINON. Index. Index. Overview Page 4. Catalogue

Even faster thanks to ExpertEase Immediate restoration directly following implant placement. new

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

WINSTA-C. Clavicle Plating System

Transcription:

» Guided Surgery by MEDENTiKA «IPS Implant systems MEDENTIGUIDE QUATTROCONE QUATTROCONE30 SURGERY MANUAL

» MedentiGuide «MedentiGuide drill sleeves support the surgeon in preparing the implant bed for MEDENTiKA implants. Their use must be planned with a specially designed 3D planning system and surgical drilling template. You can plan the surgery with standard planning programs. Treatment planning based on three dimensional imaging procedures (CT, DVT) enables high precision treatment planning and means that the treatment outcome can be accurately predicted. These software manufacturers* currently support the MedentiGuide System The advantages over conventional planning include: Precision three-dimensional planning and implantation, taking into account the desired restoration Automatic collision control that displays if the distances to the implants or nerves are too short Information on peri-implant bone quality so that conclusions can be drawn on the expected primary stability An individual drilling template can be produced on the basis of the digital planning data. This ensures the exact and precise transfer of the planning outcome to the patient s mouth. Note: MEDENTiKA GmbH accepts no liability for the correct planning, implementation and production of the drilling template. Sufficient knowledge of the 3D planning system being used and the MEDENTiKA implant system is essential. It is imperative that the user is very confident in the use of 3D planning systems before using the MedentiGuide drill sleeves. Furthermore, sufficient expertise in preoperative implant planning and dental implantology is required. * to some extent this depends on the availability of the updates of the specific manufacturer. 2 3

SYSTEM DESCRIPTION» Drilling template MedentiGuide An individual drilling template can be produced on the basis of the digital planning data. This ensures the exact and precise application of the planning outcome to the patient s mouth. MedentiGuide drill sleeves can be used in drill sleeves of various designs. The templates may be produced using suitable milling or printing systems with CADCAM technology or using alternative procedures. Insertion tool «The appropriate insertion tool is used to ensure that the outer sleeve is inserted securely into the template. NB: The drilling template must be firmly and securely seated on the jaw with no gaps. Drilling template with inserted outer sleeves Drilling template with inserted outer and innner sleeves 4 5

SYSTEM DESCRIPTION» Surgical Tray Drill lengths «QUATTROCONE QUATTROCONE30 Easy to use: No additional surgical tray is required with the MedentiGuide drill sleeve system. The drill sleeves are adapted to the Quattrocone standard drill. This significantly simplifies the preparation of the implantation and considerably reduces the material and storage costs. The MedentiGuide insertion tools are optionally available to guide the implants through the drill sleeves. The MedentiGuide System supports two drill lengths: 20 mm and 25 mm. In the planning phase it is important to ensure that the correct drill length is selected. PLEASE NOTE: The MedentiGuide drill sleeves are only designed for standard drills. The defined drilling depths do not include the drill tip of 0.2 mm. Please note their lengths if only minimum space is available to anatomical structures. Example for D 3.5 mm Implant: 15 13 11 9 7 0 Standard drill Ø 3.2 mm Bone quality D3 / D4 TWO DRILL LENGTHS: Short drill 1 marking ring Long drill 2 marking rings Total length 35.3 mm 20 mm Total length 40.3 mm 25 mm 0.2 mm drill tip 0.2 mm drill tip 6 7

SYSTEM DESCRIPTION» Sleeve in sleeve «QUATTROCONE QUATTROCONE30 MEDENTIGUIDE DRILL SLEEVES Locks in the rotational direction of the drill The inner sleeves are colour-matched to the corresponding colour-coded implants for easy recognition. Sleeve Art. No. Description Outer diameter Inner diameter Implant diameter Drill 0-32-06 0-32-07 0-32-08 Standard outer sleeve Large outer sleeve Adapter sleeve D 6.3 d 5.03 D 3.5-4.3 mm D 8.3 d 7.03 D 5.0 mm D 7.0 d 5.03 D 5.0 mm 0-32-15 Inner sleeve D 5.0 d 2.03 Pilot 0-32-16 Inner sleeve D 5.0 d 3.23 D 3.5 mm 4-14-01 4-14-06 4-14-02 4-14-07 MedentiGuide Drill Sleeves are a sleeve in sleeve system made up of various outer sleeves and matching inner sleeves. MedentiGuide drill sleeves can be used in drill sleeves of various designs. 0-32-17 Inner sleeve D 5.0 d 4.03 0-32-18 Inner sleeve D 7.0 d 4.73 D 4.3 mm 4-14-04 4-14-09 D 5.0 mm 4-14-53 4-14-55 The templates may be produced using suitable milling or printing systems with CADCAM technology or using alternative procedures. The MedentiGuide Sleeve System works with bayonet lock. The lock engages clockwise and thus in the rotational direction of the drill. 8 9

SYSTEM DESCRIPTION» MICROCONE implants D 3.5 4.3 mm QUATTROCONE30 implants 4.3 mm QUATTROCONE Implants D 5.0 mm QUATTROCONE30 Implants D 5.0 mm «d 2.02 d 2.02 Inner sleeve e.g. pilot drills H 5.0 mm H 5.0 mm D 5.0 mm Inner sleeve e.g. pilot drills d 5.03 D 5.0 mm The standard outer sleeve is used in conjunction with the QUATTROCONE implants D 3.5 - D 4.3. Standard outer sleeve For implants measuring D 3.0-4.5 d 5.03 mm D 6.3 mm H 4.0 mm H 4.0 mm H 3.0 mm D 7.0 mm d 7.03 mm Adapter sleeve To hold the standard inner sleeve Large outer sleeve For implants measuring D 5.0 The large outer sleeve must be used for the Quattrocone implants D 5.0. D 8.3 mm QUATTROCONE IMPLANTS D 3.5 - D 4.3 MM QUATTROCONE IMPLANTS D 5.0 MM Pilot 0-32-15 D 3.0 0-32-16 D 3.5 0-32-17 Pilot 0-32-15 D 3.0 0-32-16 D 3.5 0-32-17 Inner sleeve D 5.0 0-32-18 Adapter sleeve 0-32-08 Standard outer sleeve 0-32-06 Large outer sleeve 0-32-07 Large outer sleeve 0-32-07 10 11

QUATTROCONE IPS Implant systems IPS Implant systems 12 13

SYSTEM DESCRIPTION» Selection of drill length «QUATTROCONE The MedentiGuide System software supports the standard drill with two drill lengths: 20 mm and 25 mm. The distance from the top edge of the inner sleeve to the bottom edge of the implant is thus defined by the selected drill length. The distance between the lower edge of the outer sleeve and the top edge of the implant is always defined by the selected implant and drill lengths. The distance between the lower edge of the sleeve and the upper edge of the implant can be defined, depending on the desired implant length, by the choice of the drill length. NB: The desired drill length must therefore be taken into account during planning. Long drill Short drill 1 mm 4 mm 1 mm 4 mm 9 mm 4 mm 25 mm 20 mm 11 mm 11 mm 14 15

SYSTEM DESCRIPTION» MedentiGuide Placement instrument«quattrocone The implants can optionally be guided through the template for positioning. This involves the use of the corresponding MedentiGuide placement instruments, either for manual and ratchet or the contra-angled handpiece. The drill length determines whether the short or long MedentiGuide placement instrument is used. Long drill Short drill 7 9 11 13 7 9 11 13 11 13 15 Short drill & MedentiGuide placement instrument, short >> 1 marking ring Long drill & MedentiGuide placement instrument, long >> 2 markings rings 16 17

SYSTEM DESCRIPTION» MedentiGuide Placement instrument Implant alignment «QUATTROCONE MedentiGuide placement instrument, short To ensure that the implant is inserted at the correct height, it is rotated through the outer sleeve until the corresponding depth marker is flush with the top edge of the outer sleeve. 1 mm 4 mm Depth marker for implant length 11 mm If required, the implants can be aligned to the indexing of the implant connection. The MedentiGuide placement instrument is used in this case. The vertical marking on the placement instrument is aligned in the direction of the area of the square in the implant. The marking/notch on the outer sleeve is used as a guide to correctly position the implant. 20 mm 4 mm 11 mm Implant length 11 mm MedentiGuide Placement Instrument, long 1 mm 4 mm Depth marker for implant length 15 mm 5 mm 25 mm 15 mm Implant length 15 mm 18 19

» QUATTROCONE «drilling protocol (For example, for D 4.3 x 11 mm implant with the standard outer sleeve) Initial situation Pilot hole with the Ø 2.0 mm pilot drill Deep drilling with the final standard drill Ø 2.0 / 3.2 / 4.0 mm Insert the implant either by hand/ ratchet or with the contra-angled handpiece. Submerged or transgingival healing can be achieved 1 2 3 4 5 Cut a flap in the soft tissue to expose the bone around the implantation point or optionally expose the implantation point with the mucosal punch. NB: Check the drilling template at every step to ensure that it is correctly seated. It is important to observe the surgical manual for each implant system. The pilot hole is made with the Ø 2.0 mm pilot drill. Guided by the drill sleeve (inner sleeve), this defines the sagittal direction of the implant axis and the drilling depth. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. Incremental drilling is performed with the corresponding drill sleeve (inner sleeve), in this case with the D 2.0/3.2/4.0 mm standard drill. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. NB: Before inserting the implant, the inner sleeve must be removed. The implant is then screwed in position through the outer sleeve until the depth marking of the placement instrument is flush with the upper edge of the outer sleeve. Check the vertical marking on the placement instrument to ensure the desired alignment of the implant connection. The implant can heal either with submerged or transgingival methods. 20 21

» QUATTROCONE «drilling protocol (For example, for D 5.0 x 15 mm implant with the large outer sleeve) Initial situation Pilot hole with the Ø 2.0 mm pilot drill Optional interval drilling with the standard drill Ø 2.0 / 3.2 / 4.0 mm Deep drilling with the final Ø 3.2 / 4.0 / 4.7 mm standard drill Insert the implant either by hand/ratchet or with the contra-angled handpiece. Submerged or transgingival healing can be achieved 1 2 3 4 5 6 Cut a flap in the soft tissue to expose the bone around the implantation point or optionally expose the implantation point with the mucosal punch. NB: Check the drilling template at every step to ensure that it is correctly seated. It is important to observe the surgical manual for each implant system. The pilot hole is made with the Ø 2.0 mm pilot drill. Guided by the drill sleeve (adapter sleeve and the corresponding internal sleeve), this defines the sagittal direction of the implant axis and the drilling depth. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. Incremental drilling is performed with the appropriate drill sleeve (adapter sleeve and internal sleeve), in this case with the D 2.0/3.2/4.0 mm standard drill. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. The adapter sleeve is now removed with the inner sleeve from the previous drilling. The inner sleeve (0-32-18) for the final drilling is then inserted into the external sleeve. To achieve the final depth, drilling is performed with the final drill, which in this case is the standard drill D 3.2/4.0/4.7 mm. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. NB: Before screwing the D 5.0 implant into position, the inner sleeve has to be replaced with the adapter sleeve. Now the implant is screwed through the outer sleeve until the depth marking of the placement instrument is flush with the upper edge of the adapter sleeve. Check the vertical marking on the placement instrument to ensure the desired alignment of the implant connection. The implant can heal either with submerged or transgingival methods. 22 23

QUATTROCONE30 IPS Implant systems IPS Implant systems 24 25

SYSTEM DESCRIPTION» Selection of drill length «QUATTROCONE30 The MedentiGuide System software supports the standard drill with two drill lengths: 20 mm and 25 mm. The distance from the top edge of the inner sleeve to the bottom edge of the implant is thus defined by the selected drill length. The distance between the lower edge of the outer sleeve and the top edge of the implant is always defined by the selected implant and drill lengths. The distance between the lower edge of the sleeve and the upper edge of the implant can be defined, depending on the desired implant length, by the choice of the drill length. NB: The desired drill length must therefore be taken into account during planning. Long drill Short drill 1 mm 4 mm 1 mm 4 mm 7 mm 2 mm 25 mm 20 mm 13 mm 13 mm 26 27

SYSTEM DESCRIPTION» MedentiGuide Placement instrument «QUATTROCONE30 The implants can optionally be guided through the template for positioning. This involves the use of the corresponding MedentiGuide placement instruments, either for manual and ratchet or the contra-angled handpiece. The drill length determines whether the short or long MedentiGuide placement instrument is used. Long drill Short drill 7 9 11 13 7 9 11 13 11 13 15 Short drill & MedentiGuide placement instrument, short >> 1 marking ring Long drill & MedentiGuide placement instrument, long >> 2 marking rings 28 29

SYSTEM DESCRIPTION» MedentiGuide Placement instrument Implant alignment QUATTROCONE30 «MedentiGuide placement instrument, short To ensure that the implant is inserted at the correct height, it is rotated through the outer sleeve until the corresponding depth marker is flush with the top edge of the outer sleeve. 20 mm 1 mm 4 mm 6 mm Depth marker for implant length 9 mm The Quattrocone30 implants must be aligned to match the indexing of the implant connection (label AI). This is because there is only one possible position for the Quattrocone30 implants, due to their 30 angled implant shoulder. This is achieved with the corresponding MedentiGuide Placement Instrument labeled AI Q. The vertical marking on the placement instrument is aligned in the direction of the short side of the implant. The marking/notch on the outer sleeve is used as a guide to correctly position the implant. 9 mm MedentiGuide Placement Instrument, long 1 mm 4 mm Depth marker for implant length 13 mm 7 mm 25 mm 13 mm 30 31

» QUATTROCONE30 «drilling protocol (Example for D 4.3 x 13 mm implant with the standard outer sleeve when using the All-On-4 * or QuattroFix) *All-On-4 is a registered trademark of Nobel Biocare. Initial situation Pilot hole with the Ø 2.0 mm pilot drill Deep drilling with the final Ø 2.0 / 3.2 / 4.0 mm standard drill Insert the implant either by hand/ratchet or with the contra-angled handpiece. Submerged or transgingival healing can be achieved 1 2 3 4 5 Cut a flap in the soft tissue to expose the bone around the implantation point or optionally expose the implantation point with the mucosal punch. NB: Check the drilling template at every step to ensure that it is correctly seated. It is important to observe the surgical manual for each implant system. The pilot hole is drilled with the Ø 2.0 mm pilot drill. Guided by the drill sleeve (inner sleeve), this defines the sagittal direction of the implant axis and the drilling depth. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. Incremental drilling is performed with the corresponding drill sleeve (inner sleeve), in this case with the D 2.0/3.2/4.0 mm standard drill. The recommended speed is 300-600 rpm and the maximum speed is 800 rpm. NB: Before inserting the implant, the inner sleeve must be removed. The implant is then screwed in position through the outer sleeve until the depth marking of the placement instrument is flush with the upper edge of the outer sleeve. The vertical marking of the placement instrument must be observed to ensure the necessary alignment of the implant connection. The implant can heal either with submerged or transgingival methods. 32 33

» MedentiGuide products «IPS Implant systems

36» Surgery Surgery «37 MedentiGuide Outer sleeve standard Titanium Grade 5 CF MedentiGuide Placement instrument Implant Manual and ratchet Stainless steel Diameter (mm) D 6.3 / d 5.03 Article No. 0-32-06 Please note: This sleeve is used for implants D 3.0 - D 4.5. Implant connection RI RI AI AI Type Quattrocone Quattrocone Quattrocone30 Quattrocone30 Version short long short long Article No. 3-32-03 3-32-04 4-32-03 4-32-04 Please note: These insertion tools are used to insert implants when using MedentiGuide sleeves. MedentiGuide Outer sleeve large Titanium Grade 5 CF MedentiGuide Placement instrument Implant Contra-angle Stainless steel MedentiGuide Adapter sleeve Titanium Grade 5 CF Diameter (mm) D 8.3 / d 7.03 Article No. 0-32-07 Please note: This sleeve is used for implants D 5.0. Implant connection RI RI AI AI Type Quattrocone Quattrocone Quattrocone30 Quattrocone30 Version short long short long Article No. 3-32-01 3-32-02 4-32-01 4-32-02 Please note: These insertion tools are used to insert implants when using MedentiGuide sleeves. MedentiGuide Inner sleeve Quattrocone Implant Titanium Grade 5 CF Diameter (mm) D 7.0 / d 5.03 Article No. 0-32-08 Please note: This sleeve is used as a connecting piece between the Outer sleeve large and the Inner sleeves for the drill diameter D 2.0 - D 4.0. Placement instrument MedentiGuide Stainless steel Diameter (mm) D 5.0 / d 2.03 D 5.0 / d 3.23 D 5.0 / d 4.03 D 7.0 / d 4.73 Colour code grey pink purple brown Drill diameter D 2.0 mm D 3.2 mm D 4.0 mm D 4.7 mm Article No. 0-32-15 0-32-16 0-32-17 0-32-18 Type Outer sleeve standard Outer sleeve large Article No. 0-32-19 0-32-20

Publisher: MEDENTiKA GmbH Hammweg 8-10 76549 Hügelsheim Tel: +49 (0)7229 69912-10 info@medentika.de www.medentika.com Design: The WeberFink GbR graphic design studio www.weberfink.de Date: August 2018 We are certified according to: DIN EN ISO13485:2012 Medical Devices Directive 93/42/EEC, Annex II Subject to modification without notice. Errors and omissions excepted. The instructions for use and guarantee conditions are available on the website www.medentika.com. Please contact the manufacturer directly for further information concerning the guarantee.

MEDENTiKA GmbH Hammweg 8-10 76549 Hügelsheim info@medentika.de www.medentika.com» MEDENTiKA always well-treated «