The Gold Standard in Pediatric VAD Therapy A Compilation of Publications Demonstrating the Clinical Excellence of EXCOR Pediatric

Similar documents
Pediatric Mechanical Circulatory Support (MCS)

Why Children Are Not Small Adults? Treatment of Pediatric Patients Needing Mechanical Circulatory Support

Bridge to Heart Transplantation

Destination Therapy SO MUCH DATA IN SUCH A SMALL DEVICE. HeartWare HVAD System The ONLY intrapericardial VAD approved for DT.

Implantable Ventricular Assist Devices and Total Artificial Hearts. Policy Specific Section: June 13, 1997 March 29, 2013

Product Catalog. EXCOR Pediatric The Ventricular Assist Device for Children

Heart-lung transplantation: adult indications and outcomes

HeartWare ADVANCE Bridge to Transplant Trial and Continued Access Protocol Update

DECLARATION OF CONFLICT OF INTEREST

Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) Long Term Outcomes

Surgical Options for Advanced Heart Failure

Berlin Heart Pediatric Assistance Device: The Beginnings, The Teachings And The Cruising Speed : A Monocentric Experience With The Same System

Extra Corporeal Life Support for Acute Heart failure

ORIGINAL ARTICLE. Alexander M. Bernhardt a, *, Theo M.M.H. De By b, Hermann Reichenspurner a and Tobias Deuse a. Abstract INTRODUCTION

Jennifer A. Brown The Cleveland Clinic School of Perfusion Cleveland, Ohio

MEDICAL POLICY SUBJECT: VENTRICULAR ASSIST DEVICES

SPECIAL FEATURE.

Understanding the Pediatric Ventricular Assist Device

I have nothing to disclose.

AllinaHealthSystem 1

Management of Cardiogenic Shock. Dr Stephen Pettit, Consultant Cardiologist

How to Develop a Comprehensive Ventricular Assist Device Program

ECMO as a Bridge to Heart Transplant in the Era of LVAD s.

How to mend a broken heart: transplantation or LVAD?

Implantable Ventricular Assist Devices and Total Artificial Hearts

Ventricular Assist Devices (VADs) and Percutaneous Cardiac Support Systems

Echo assessment of patients with an ECMO device

LVAD Complications, Recovery

Left Ventricular Assist Devices (LVADs): Overview and Future Directions

Medical Policy. MP Total Artificial Hearts and Implantable Ventricular Assist Devices

Mechanical Circulatory Support: Reality and Dreams Experience of a Single Center

Mechanical Support in the Failing Fontan-Kreutzer

Total Artificial Hearts and Implantable Ventricular Assist Devices

Japanese Multicenter Outcomes With the HeartMate II Left Ventricular Assist Device in Patients With Small Body Surface Area

Japanese Multicenter Outcomes With the HeartMate II Left Ventricular Assist Device in Patients With Small Body Surface Area

Complications in CHD with a little help from our friends

Modern Left Ventricular Assist Devices (LVAD) : An Intro, Complications, and Emergencies

When to implant VAD in patients with heart transplantation indication. Aldo Cannata Dept of Cardiac Surgery Niguarda Ca Granda Hospital Milano

Recent Trials With Durable LVADs: Is There a Superior Device?

Heart Transplantation is Dead

Pediatric Mechanical Circulatory Support - What to Use

Risk Factors for Adverse Outcome after HeartMate II Jennifer Cowger, MD, MS St. Vincent Heart Center of Indiana

Extracorporeal life support in preoperative and postoperative heart transplant management

Ventricular Assist Device in Pediatric Heart Failure 성균관의대삼성서울병원흉부외과학교실

Advances in Advanced Heart Failure Therapies. Disclosures. Management Algorithm for Patients in Cardiogenic Shock

Mechanical Circulatory Support in the Management of Heart Failure

ECMO and VAD implantation

Andrew Civitello MD, FACC

First Experiences With the HeartWare Ventricular Assist System in Children

To ECMO Or Not To ECMO Challenges of venous arterial ECMO. Dr Emily Granger St Vincent s Hospital Darlinghurst NSW

เอกราช อร ยะช ยพาณ ชย

Total Artificial Hearts and Implantable Ventricular Assist Devices

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Artificial Heart Program

Total Artificial Hearts and Implantable Ventricular Assist Devices

DEMYSTIFYING VADs. Nicolle Choquette RN MN Athabasca University

Ramani GV et al. Mayo Clin Proc 2010;85:180-95

Medical Policy An independent licensee of the Blue Cross Blue Shield Association

Implantable Ventricular Assist Devices and Total Artificial Hearts

Selecting Patients for the SynCardia temporary Total Artificial Heart Help Your Patients Live Longer, Live Better

Implantable Ventricular Assist Devices and Total Artificial Hearts

Description. Section: Surgery Effective Date: April 15, Subsection: Transplant Original Policy Date: September 13, 2012 Subject:

The current trends of mortality following congenital heart surgery: the Japan Congenital Cardiovascular Surgery Database

Post-transplant Outcomes of Children Bridged to Transplant With the Berlin Heart EXCOR Pediatric Ventricular Assist Device

MEDICAL POLICY SUBJECT: VENTRICULAR ASSIST DEVICES. POLICY NUMBER: CATEGORY: Technology Assessment

Right Heart Failure in LVAD patients: Prevention and Management.

Pulmonary Hypertension

VENTRICULAR ASSIST DEVICES AND TOTAL ARTIFICIAL HEARTS

VENTRICULAR ASSIST DEVICES AND TOTAL ARTIFICIAL HEARTS

Adverse Event. Adverse Event Status. Please enter the date of the event you are reporting: Please enter a label describing this event:

ECMO AND SHORT-TERM SUPPORT:

Name of Policy: Ventricular Assist Devices and Total Artificial Hearts

Ted Feldman, M.D., MSCAI FACC FESC

Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients

Strengthening Your VAD Program

Overview of MCS in Bruce B Reid, MD Surgical Director Artificial Heart Program/Heart Transplantation

Mechanical Ventricular Circulatory Support in Children; Bad Oeynhausen Experience

Conall T. Morgan, MD, MRCPCH, Cedric Manlhiot, BSc, Brian W. McCrindle, MD, MPH, and Anne I. Dipchand, MD, FRCPC

Extracorporeal Membrane Oxygenation (ECMO)

None. Declaration of conflict of interest

The Japanese Organ Transplant Act came into effect

Improving Outcomes in Patients With Ventricular Assist Devices Transferred From Outlying to Tertiary Care Hospitals

From Recovery to Transplant: One Patient's Journey

Total Artificial Hearts and Implantable Ventricular Assist Devices

Ischemic Ventricular Septal Rupture

New ventricular assist devices. FW Mohr Clinical seminar: Devices for severe heart failure ESC congress Stockholm 2010

Extracorporeal Membrane Oxygenation (ECMO)

Update on Mechanical Circulatory Support. AATS May 5, 2010 Toronto, ON Canada

Planned, Short-Term RVAD During Durable LVAD Implant: Indications and Management

Concomitant Aortic Valve Procedures in Patients Undergoing Implantation of Continuous-Flow LVADs: An INTERMACS Database Analysis

Mechanical cardiac support in children with congenital heart disease with intention to bridge to heart transplantation


Mechanical Cardiac Support in Acute Heart Failure. Michael Felker, MD, MHS Associate Professor of Medicine Director of Heart Failure Research

Chairman and O. Wayne Isom Professor Department of Cardiothoracic Surgery Weill Cornell Medicine

Adverse Event - Intermacs

Heart Transplantation in Seniors European View

Description. Section: Surgery Effective Date: January 15, 2015 Subsection: Transplant Original Policy Date: September 13, 2012 Subject:

Adult Extracorporeal Life Support (ECLS)

The Heart Center Heart Failure and Transplant Program

Transcription:

EXCOR Pediatric The Gold Standard in Pediatric VAD Therapy A Compilation of Publications Demonstrating the Clinical Excellence of EXCOR Pediatric

EXCOR Pediatric The Gold Standard in Pediatric VAD Therapy EXCOR Pediatric is the only VAD system approved to provide circulatory support for pediatric patients in the US, Canada, the European Union and several other countries worldwide. The excellent clinical performance has been proven in clinics around the world and has been documented in various clinical studies including a prospective multicenter controlled clinical trial conducted in the US. EXCOR Pediatric offers solutions for univentricular or biventricular support. The EXCOR Pediatric system can support pediatric patients of all ages, from newborns to adolescents. The wide portfolio of pumps and cannulae allows Berlin Heart to meet the individual needs of each patient. Since 1990, the EXCOR Pediatric VAD has been successfully used in increasing numbers at 166 pediatric heart centers in 37 countries. More than 1,700 EXCOR Pediatric patients have been implanted with the EXCOR Pediatric VAD system and benefited from Berlin Heart s life saving technology. FIGURE 1 Illustration of countries in which EXCOR Pediatric is used worldwide (labeled in blue) The EXCOR Pediatric has become an important option for our pediatric patients with severe cardiac failure, providing successful outcomes for even our smallest patients. Dr. M. Bleiweis, University of Florida, Shand s Children s Hospital 2

Worldwide EXCOR Pediatric Experience Source: Berlin Heart Registry Clinical data of patients implanted between February 1990 and August 2015 has been captured and analyzed. Worldwide VAD therapy with EXCOR Pediatric demonstrates excellent outcome (1-year survival 74%, n=1,609). Patient characteristics Variable EXCOR Pediatric patients Age, Median (range) 2.0 years (1 day-17 years) Mean cardiac index 2.1 l/min/m 2 Mean LVEF 19% Preoperative MCS (short-term) 33% Ratio male/female sex 52%/48% Primary diagnosis Outcome The mean duration of support was 85 days. The longest duration of support for toddlers and adolescents was 2.5 years and 3.5 years, respectively. 1-year survival for all patients was 74%. 2% 2% 1% 3% 7% 11% 22% Type of support RVAD 1% 52% DCM Congenital HD Myocarditis Other Restrictive CMP Postcardiotomy Post HTX ICMP Toxic CMP FIGURE 2 Primary diagnosis Outcome [%] 100 90 80 70 60 50 40 30 20 10 0 0 1 2 3 4 5 6 7 8 9 10 11 12 74 % 60 % 10 % 4 % Time on Device [Months] Overall survival On system Transplanted BVAD 39% LVAD 60% Died Weaned Recovered FIGURE 4 Competing outcome with overall survival of EXCOR Pediatric patients worldwide At 1-year, 60% of the patients (n=1,609) have been transplanted, 10% have been weaned and 4% are still on support. FIGURE 3 Type of support 3

EXCOR Pediatric Prospective Trial of a Pediatric Ventricular Ass Review of the IDE Trial Results Fraser CD Jr, Jaquiss RD, Rosenthal DN, Humpl T, Canter CE, Blackstone EH, Naftel DC, Ichord RN, Bomgaars L, Tweddell JS, Massicotte MP, Turrentine MW, Cohen GA, Devaney EJ, Pearce FB, Carberry KE, Kroslowitz R, Almond CS, N Engl J Med. 2012;367(6):532-41 Background Options for mechanical circulatory support as a bridge to heart transplantation or recovery in children with severe heart failure are limited. Methods Study design: Prospective, multicenter, single-arm study Patients (n=48) 16 years of age or younger were divided into two cohorts according to body-surface area: Cohort 1: n=24, BSA <0.7 m 2 Cohort 2: n=24, BSA 0.7 to <1.5 m 2 The primary efficacy endpoint for the EXCOR Pediatric VAD was time to cardiac transplantation, death 1 or weaning with an unacceptable neurologic outcome. 2 1 Definition death: death while on support or within 30 days after weaning or before hospital discharge, whichever was longer 2 Definition unacceptable neurologic outcome: either coma or the presence of profound sensory, motor, language, or cognitive impairment as assessed with the Pediatric Stroke Outcome Measure (PSOM) 4

ist Device Patient characteristics Variable EXCOR Cohort 1 EXCOR Cohort 2 Age in months, Median (range) 11.7 (2.6-45.6) 111.2 (50.8-191.8) Weight in kg, Median (range) 9.2 (3.6-13.6) 30.7 (16.0-58.1) BSA in m 2, Median (range) 0.44 (0.23-0.62) 1.08 (0.71-1.66) Male/female sex (%) 50/50 54/46 INTERMACS profile status (%) 1 2 46 54 54 46 Preoperative ECMO for 10 d or less (%) 25 33 Preoperative centrifugal VAD (%) 8 0 Preoperative mechanical ventilation (%) 83 46 Preoperative inotrope infusion (%) 92 88 Preoperative cardiac arrest (%) 29 21 Closure of intracardiac shunt at implantation (%) 29 12 Valve repair or replacement at implantation (%) 8 17 Time (minutes) required for cardiopulmonary bypass [Average ± h] 185 ± 49 176 ± 52 Primary diagnosis 4% 4% 79% 13% FIGURE 5 Primary diagnosis EXCOR Pediatric cohort 1 4% 71% 25% FIGURE 6 Primary diagnosis EXCOR Pediatric cohort 2 CHD DCM or myocarditis Hypertrophic CMP Restrictive CMP Type of support 29% 71% FIGURE 7 Type of EXCOR Pediatric support cohort 1 42% 58% FIGURE 8 Type of EXCOR Pediatric support cohort 2 LVAD BVAD 5 IDE Trial & Post-Approval Trial

For children in cohort 1 and 2, the median duration of support with EXCOR Pediatric VAD was 28 days and 43 days, respectively. The longest duration of support with EXCOR Pediatric VAD in cohort 1 and 2 was 174 days and 192 days, respectively. Competing outcome with overall survival of EXCOR Pediatric VAD cohort 1 and cohort 2 100 100 90 88% 90 92% 88% 80 80 Percentage of patients 70 60 50 40 30 Percentage of patients 70 60 50 40 30 20 20 10 8% 0 4% 0 20 40 60 80 100 120 140 160 180 200 10 8% 4% 0 0 20 40 60 80 100 120 140 160 180 200 Time on device [days] Time on device [days] Overall survival On support Transplanted Overall survival On support Transplanted Weaned Died Weaned with unacceptable neurological outcome Died FIGURE 9 Competing outcome with overall survival of EXCOR Pediatric VAD cohort 1 At 174 days, 88% of the patients had undergone a successful transplantation, 4% had an unacceptable neurologic outcome after weaning from the device and 8% had died. Figure adapted from Fraser et al. N Engl J Med. 2012. FIGURE 10 Competing outcome with overall survival of EXCOR Pediatric VAD cohort 2 At 192 days, 92% of the patients had been transplanted or weaned. 88% of the patients had undergone a success ful transplantation and 4% had been weaned successfully from the device. Figure adapted from Fraser et al. N Engl J Med. 2012. Overall, for patients supported with EXCOR Pediatric VAD, 88% in cohort 1 and 92% in cohort 2 were bridged to transplant or recovery with acceptable neurological outcome. 6

Serious Adverse Events Serious adverse events include bleeding, infection and neurological dysfunction. In total, neurological dysfunctions occurred in 29% of the patients (n=48). Thereof, 14% with no reported deficits (PSOM 0), 29% with mild deficits (PSOM 0.5-1.0), 29% with moderate deficits (PSOM 1.5-2.0) and 14% with severe deficits (PSOM >2.5)*. 2 patients were not assessed. Of the patients with neurological dysfunction, 50% were on ECMO or other VAD support prior to implantation of EXCOR Pediatric VAD. The neurological dysfunction rate of 29% in cohort 2 is similar to that reported in patients (BSA >1.2 m 2 ) who were supported with adult-sized VAD 1. The sequelae of neurological dysfunction did not preclude eligibility for transplantation in the majority of patients. The results of the EXCOR Pediatric IDE trial demonstrated high survival rates with acceptable complications rates. 46 pump exchanges occurred in cohorts 1 and 2 combined. 43 pumps were changed due to blood clots. Serious Adverse Events Patients with event cohort 1 Patients with event cohort 2 Major bleeding a,b a Units PRBC within 24 h during 1 st 7 d post-implant ( 20 cc/kg PRBC for patients <50 kg) b Any transfusion or PRBC after 7 d post-implant 42% 50% Infection Localized non-device related Percutaneous site Internal pump component Sepsis Neurological dysfunction c,d,e Ischemic Hemorrhagic c TIA d Ischemic/Hemorrhagic CVA e Patients <6 months: new abnormality head ultrasound/eeg positive for seizure activity Non-CNS thromboembolism Arterial Venous 50% 17% 0% 21% 29%* 29% 0% 4% 4% 42% 0% 0% 25% 29%* 21% 8% Device malfunction 0% 0% Hemolysis Early (<72 h post-implant) Late (>72 h post-implant) 0% 4% * The severity of neurological complication was assessed according to a standardized neurological exam, that included imaging and a clinical examination using the Pediatric Stroke Outcome Measure (PSOM) 1 Reinhartz et al., Multicenter experience with the Thoratec Ventricular Assist Device in children and adolescents. J. Heart Lung Transplantation, 2001 0% 0% 0% 4% 7 IDE Trial & Post-Approval Trial

EXCOR Pediatric Prospective Post-Approval Trial Preview of Post-Approval Trial Results Jaquiss et al., Berlin Heart Post Approval Outcomes in North America, Oral Communication ISHLT 2015 Background Assessment of clinical efficacy and safety in prospective study Methods The clinical efficacy and safety of the EXCOR Pediatric in the commercial setting was assessed in an FDA mandated, prospective, multicenter post-approval study. Within the post-approval study 39 non-selected patients were enrolled, while the post-approval study phase (2011-2015) included 247 all comer patients. This study compared the clinical efficacy and safety to the IDE study (n= 48) and the IDE compassionate use cohort (2007-2011). Patient characteristics Post-approval phase (n=247) Post-approval study (n=39) IDE compassionate use (n=204) IDE (n = 48) Age in months, Median (range) 19.5 (0-389.3) 23.1 (0-196.1) 18.6 (0.2-191.8) 48.2 (2.6-191.8) Weight in kg, Median (range) 10.7 (2.9-112.0) 10.6 (3.4-70.0) 10.0 (2.8-60.0) 14.8 (3.6-58.1) BSA in m 2, Median (range) 0.49 (0.20-2.30) 0.49 (0.23-1.76) 0.48 (0.19-1.67) 0.67 (0.23-1.66) Diagnosis CHD (%) Single-ventricle physiology (%) Two-ventricle physiology (%) 24.3 11.3 13.0 12.8 7.7 5.1 28.9 8.8 20.1 18.8 0 18.8 Preoperative ECMO (%) n.s. 25.6 n.s. 29.2 Preoperative mechanical ventilation (%) n.s. 59.0 n.s. 66.7 Device type LVAD or RVAD (%) BVAD (%) 72.5 27.5 64.1 35.9 62.8 37.3 64.6 35.4 Time on support in days, Median (range) 55 (0-457) 55 (0-457) 40 (1-435) 38 (0-192) The post-approval phase patient population was at higher risk compared to the IDE cohort (smaller, younger, longer on support, higher CHD and especially single ventricle physiologiy population). 8

Adjudicated adverse events IDE vs. Post-approval cohort (in events per 100 patient-months): Event IDE (n=48) Post-Approval Study (n=39) p-value Major Bleeding 40.4 16.6 0.001 Major Infection 63.4 14.4 <0.001 Stroke (any stroke) 18.6 12.3 0.299 Ischemic stroke 16.4 8.7 0.143 Hemorrhagic stroke 2.2 3.6 0.848 Pump changes 47.0 22.4 0.002 An improved safety profile in the postapproval study cohort compared to the IDE cohort was observed despite longer time on support. The improved safety reflects the growing expertise in EXCOR Pediatric therapy. 9 IDE Trial & Post-Approval Trial

Efficacy Outcomes: IDE vs. Post-Approval Phase Cohort Outcome IDE (n = 48) Post-Approval Phase (n = 247) Transplanted 42 (87.5%) 172 (69.9%) Successfully Weaned 1 (2.1%) 8 (3.2%) Died or Unsuccessfully Weaned 5 (10.4%) 54 (21.9%) On Device 0 (0.0%) 13 (5.3%) Overall Survival 43 (89.6%) 180 (76.9%) The efficacy in the post-approval cohort was slightly inferior to the IDE cohort, 76.9% vs. 89.6% respectively. However comparing the post-approval cohort to the more similar IDE compassionate use cohort, the postapproval cohort proved to be superior with an overall survival of 76.9% vs. 70.6%. 10

Efficacy Outcomes: IDE compassionate use vs. Post-Approval Phase Cohort Outcome IDE compassionate use (n = 204) Post-Approval Phase (n = 247) Transplanted 138 (67.7%) 172 (69.9%) Successfully Weaned 6 (2.9%) 8 (3.2%) Died or Unsuccessfully Weaned 60 (29.4%) 54 (21.9%) On Device 0 (0.0%) 13 (5.3%) Overall Survival 144 (70.6%) 180 (76.9%) Similar survival rates and an improved adverse event profile were shown in the post-approval setting in patients compared to the selected IDE-patient cohort demonstrating the clinical efficacy and safety of EXCOR Pediatric in commercial setting. 11 IDE Trial & Post-Approval Trial

Long-term Mechanical Circulatory Support in Pediatric Patients with Review of the Bad Oeynhausen Experience Sandica et al., Long term mechanical circulatory support in pediatric patients: The Bad Oeynhausen experience, oral communication EACTS 2014 During the study period (January 2008 to April 2014), 29 pediatric patients were supported with EXCOR Pediatric. Median age of EXCOR Pediatric patients was 3.4 years, whereof 29% of the patients were younger than 1 year. Patient characteristics Variable EXCOR Pediatric patients (n=29) Age in years, Median (range) 3.4 (0.25-16.5) Weight in kg, Median (range) 13 (4.2-67.2) Preoperative cardiac arrest (%) 18 Preoperative inotrope infusion (%) 93 Preoperative mechanical ventilation (%) 28 Preoperative renal failure (%) 7 Ratio male/female sex (%) 62 / 38 Primary diagnosis Type of support Chronic myocarditis 7% HOCM 7% UVAD* 10% RCM 7% CHD 10% DCM 38% BVAD 24% LVAD 66% Myocarditis 31% FIGURE 11 Primary diagnosis Within the CHD cohort, there were 3 patients, all with single ventricle physiology. 2 of the 3 patients were supported at the Fontan stage, and 1 of the patients was supported at the Glenn stage. 1 of the 2 Fontan patients had a mechanical mitral valve. FIGURE 12 Type of support *Of the 29 patients, 3 presented with single ventricle physiology and were supported with an UVAD. 12

EXCOR Pediatric Outcome The overall mean support time was 126 days (4-619 days), with a cumulative experience of 3,647 days of cardiac support. 4 patients were supported for more than 6 months, 3 patients were on EXCOR Pediatric support for more than 12 months. Longest time on support was 619 days. Overall survival was 90%, whereof 66% of the patients were transplanted, 21% were weaned and 3% were still on support. All single ventricle physiology patients were successfully supported until transplantation. There were no deaths after heart transplantation or after explantation in any of the EXCOR Pediatric patients. Percentage of patients 100 90 80 70 60 50 40 30 20 90% 45% 24% 21% Overall survival Transplanted Weaned On support Died 10 10% 0 0 20 40 60 80 100 120 140 160 180 200 Time on device (days) FIGURE 13 Competing outcome with overall survival at 195 days (n=29) At 195 days, 45% of the patients were transplanted, 21% had been weaned, 24% were still on support and 10% died on support. Survival at 195 days was 90%. Timing of EXCOR Pediatric implantation is critical. Early implantation should be performed before irreversible end-organ dysfunction is evident. Accurate surgical technique during EXCOR Pediatric implantation is of high importance 1. With increasing experience and proven safety with long-term circulatory support in children, it is presumed that a higher proportion of patients can be weaned from EXCOR Pediatric support, thus in some cases avoiding the need for cardiac transplantation 1. Due to a shorter duration of pre-existing illness and comorbidities, and the higher regenerative capacity in the pediatric population, bridge to recovery can present a more frequent option in the future for the pediatric VAD population 1. However the Bad Oeynhausen experience demonstrates that this strategy needs to be associated with early implantation of EXCOR Pediatric. 13 Multicenter and Single Center Studies

Serious adverse events 14 blood pumps in 9 patients were changed within the study period. An aggressive policy to change the EXCOR blood pumps when fibrin deposits that may initiate thrombus formation are observed, may positively influence the rate of neurological complications 1. In this series, neurological complications without any major deficit were reported in 10% of the patients. Of these patients, 7% suffered from a cerebral embolism and 3% of intracranial bleeding. All patients recovered well without any major neurological deficit. Superficial infections were reported in 14% of the patients. Meticulous hemostasis and primary chest closure in the operating room allowed for early extubation and dramatically decreased the risk of infections in this EXCOR Pediatric cohort 1. 100 90 Percentage of patients 80 70 60 50 40 30 20 10 0 3% 7% Neurological complications 14% Superficial infections Hemorrhagic Ischemic FIGURE 14 Rate of neurological complications and superficial infections Neurological complications and superficial infections were reported in 10% and 14% of the EXCOR Pediatric patients, respectively. 1 Sandica et al., Safety of Long-Term Mechanical Support With Berlin Heart EXCOR in Pediatric Patients, World J Pediatr Congenit Heart Surg. 2012 Jan 1;3(1):72-6 The Bad Oeynhausen experience has proven that long-term EXCOR Pediatric support with a low rate of adverse events is possible. 14

15 Multicenter and Single Center Studies Horst Wackerbarth: The Red Couch - A Gallery of Mankind Tobias R. & Dr. Eugen S. Herz- und Diabeteszentrum NRW Bad Oeynhausen, Deutschland 2011

Largest Single-center Experience with Treatment of Cardiogenic Shock Review of the Berlin Experience Hetzer et al., Single-center experience with treatment of cardiogenic shock in children by pediatric ventricular assist devices, J Thorac Cardiovasc Surg 2011;141:616-23 In February 1990, the first pediatric patient was supported with an EXCOR VAD at the German Heart Institute Berlin. Continuous improvement of the system and adaption to the pediatric population as well as an increasing experience in pediatric VAD management and anticoagulation resulted in improved survival. The German Heart Institute Berlin data details the early experience with the EXCOR Pediatric system. During the study period (January 2002 to April 2009), 49 children were supported with EXCOR Pediatric. Patient characteristics Variable EXCOR Pediatric patients (n=49) Age in months, Median (range) 72 (12-204) Weight in kg, Median (range) 19 (3.6-80) Preoperative cardiac arrest (%) 29 Ratio male/female sex (%) 51 / 49 Preoperative ECMO (%) 14 Preoperative mechanical ventilation (%) 27 Primary diagnosis Type of support Post-HTX 4% Toxic CMP 2% RCM 6% RVAD 2% PPS 12% BVAD 22% CHD 12% DCM 51% LVAD 76% Myocarditis 12% FIGURE 15 Primary diagnosis FIGURE 16 Type of support 16

in Children by EXCOR Pediatric Outcome The median support time was 40 days (0-420 days), with a cumulative experience of 3,303 days of cardiac support. Overall survival was 69%. Of the patients younger than 1 year 93% were supported successfully until transplantation or recovery. Outcome per patient age 100 90 93% 80 70 67% Overall survival (%) 60 50 40 30 20 10 40% 0 <1 year 1-8 Years >8 years FIGURE 17 Outcome per patient age (n=49) EXCOR Pediatric treatment of infant younger than 1 year (n=15) was successful in 93% of the patients. 40% and 67% of the patient aged 1-8 (n=14) and older than 8 years (n=30) were successfully supported until transplantation or recovery, respectively. 17 Multicenter and Single Center Studies

Outcome per diagnosis 100 100% Overall survival (%) 90 80 70 60 50 40 30 20 10 0 73% 80% 33% 50% FIGURE 18 Outcome per diagnosis (n=49) Highest survival rates have been demonstrated in patients diagnosed with graft failure after heart failure and myocarditis (100 and 80%, respectively). CHD is the most challenging diagnosis, 33% survived until transplantation or recovery. Serious adverse events Overall 46 pumps had been exchanged. Thereof 12 pump exchanges were performed during a 3-months period in a single patient with HIT type II. Serious adverse event EXCOR Pediatric patients (n=49) Bleeding requiring re-thoracotomy 22% CVA 12% The EXCOR Pediatric VAD offers a valuable option as a bridge to transplant or recovery for children with cardiogenic shock. 18

Multicenter and Single Center Studies 19

Weaning after Long-term Support of Pediatric Patients with EXCOR Review of the Erlangen Experience R. Cesnjevar, A. Purbojo & A. Rüffer, Weaning after Long-term Support, oral communication EPUG 2014 During the study period (September 2008 to April 2014), 11 children diagnosed with either myocarditis or dilative cardiomyopathy were supported with EXCOR Pediatric. Patient characteristics Variable EXCOR Pediatric patients (n=11) Age in months, Median (range) 50.4 (6-192) Weight in kg, Median (range) 18 (6.6-61) Ratio male/female sex (%) 64 / 36 Preoperative ECMO (%) 36.4 Type of support BVAD 18% LVAD 82% FIGURE 19 Type of support 20

Pediatric Outcome The median support time was 133 days (3-877 days), with a cumulative experience of 2,290 days of cardiac support. Overall survival was 91%. 46% of the patients were transplanted, 36% were weaned and 9% are still on support. Outstanding survival rates after EXCOR Pediatric support in the setting of myocarditis and DCM have been demonstrated. High weaning rate of 36% was observed with EXCOR Pediatric support in this single center experience. Percentage of patients 100 90 80 70 60 50 40 30 20 10 0 0 60 120 180 240 300 360 Time on device (days) FIGURE 20 1-year survival (n=11) At 360 days, 37% of the patients were transplanted, 27% had been weaned and 9% died on support. 27% were still on support. Thereof, one patient was weaned after 700 days, one patient transplanted at 877 days of support and one patient was still on support at 527 days. A 3-year old girl diagnosed with DCM was supported for 877 days before successful transplantation. For a toddler, this is the longest time on support worldwide. It is important to note that no blood pump replacement was required anytime during the 877 days of support. Additionally, no major complications occurred during EXCOR Pediatric support. Long-term EXCOR Pediatric support does not preclude recovery of the failing ventricle and weaning. A 1-year old girl was diagnosed with myocarditis and pulmonary edema. After implantation of the EXCOR Pediatric VAD significant improvement of the LVEF was observed. The patient was successfully weaned after 700 days on EXCOR Pediatric support. 91% 37% 27% 9% Overall survival Transplanted Weaned On support Died 21 Multicenter and Single Center Studies

A Longer Waiting Game: Bridging Children to Heart Transplant with Review of the United Kingdom Experience Cassidy et al., A longer waiting game: bridging children to heart transplant with the Berlin Heart EXCOR device the United Kingdom experience, J Heart Lung Transplant. 2013 Nov;32(11):1101-6 During the study period (December 2004 to December 2011), 102 children were supported with EXCOR Pediatric with a cumulative experience of 5,247 days of support. Patient characteristics Primary diagnosis Other 10% Myocarditis 10% Variable EXCOR Pediatric patients (n=102) Age in months, Median (range) 30.5 (0-202.8) Weight in kg, Median (range) 11.6 (3-90) Preoperative cardiac arrest (%) 23.5 Preoperative mechanical ventilation (%) 93 CHD 13% Dilated or anthacycline CMP 67% Preoperative ECMO (%) 24.5 FIGURE 21 Primary diagnosis Type of support BVAD 37% LVAD 63% FIGURE 22 Type of support 22

EXCOR Pediatric Type of support The overall median support time was 39 days (range 1-252 days). The median support time was longer in children who weighed 20 kg compared to whose weighing >20 kg (43 vs. 24 days). The median length of support is considerably longer compared with a median waiting time of 7 days (longest 22 days) in the 1998 to 2003 era due to a static transplant rate and gradual increase in transplant candidates. Overall survival was 84%, 72% survived to transplantation and 12% demonstrated sufficient recovery of myocardial function for explantation. Variability of survival was noted between diagnostic groups. Children with CHD had the lowest survival (69%) of any individual group. The CHD subpopulation included 5 patients with single ventricle physiology and ventricular failure after Glenn shunt. Percentage of patients 100 90 80 70 60 50 40 30 20 10 0 0 20 40 60 80 100 120 140 160 180 200 220 252 Time on device (days) FIGURE 23 Competing outcome with overall survival At 253 days, 72% of the patients were transplanted, 12% had been weaned and 16% died on support. 84% 72% 16% 12% Transplanted Weaned Died On support Overall survival The Berlin Heart EXCOR Pediatric experience in the UK has allowed significant increases in the number of children offered MCS as BTT and the length of time that they can be safely supported. Although younger children 20 kg have significantly longer waiting times on VAD support, their outcomes are comparable to older children. 23 Multicenter and Single Center Studies

First Polish Multicenter Experience with EXCOR Pediatric Successful Review of the Initial Experience in Poland Kansy et al., First Multicenter Experience with EXCOR Pediatric in Poland - Successful introduction of pediatric VAD therapy, oral communication AEPC 2015 A total of 24 patients were implanted between December 2009 and March 2015. Patient characteristics Variable EXCOR Pediatric patients (n=24) Age in years, Mean (range) 6.1 (0.2-15.0) Weight in kg, Mean (range) 21.8 (4.9-57.0) BSA in m 2, Mean (range) 0.8 (0.24-1.71) LVEF in %, Mean (range) 17.7 (8-47) INTERMACS profile 1 2 3 4 8.5% 50.0% 33.0% 8.5% Preoperative inotrope infusion 100 Preoperative ECMO (%) 16.7 Preoperative mechanical ventilation (%) 37.5 Primary diagnosis RCM 4% Type of support CHD 8% LVNC 8% DCM 42% BVAD 21% ICM 13% Myocarditis 25% LVAD 79% FIGURE 24 Primary diagnosis FIGURE 25 Type of support 24

Introduction of Pediatric VAD Therapy Outcome Mean support time was 165 days (range 16-1,097). Mean support time to heart transplantation was 160 days (range 69-433 days). Longterm support of more than 3 years on VAD reflects the overall trend of extended waiting time until heart transplantation. Overall survival was 79 %, whereof 41.5 % survived to transplantation, 16.5 % demonstrated sufficient recovery of myocardial function for explantation and 21 % were still on support. One patient required re-implantation 7 days after weaning, he is still on EXCOR support. Percentage of patients 100 90 80 70 60 50 40 30 20 10 0 0 2 4 6 8 10 12 14 16 18 20 22 24 Time on device (months) 79% 41.5% 21% 16.5% Overall survival Transplanted Weaned On support Died FIGURE 26 Competing outcome with overall survival At 2 years, 41.5% of the patients were transplanted, 16.5% had been weaned, 21% are still on support and 21% died on support. Serious adverse events Serious adverse events EXCOR Pediatric patients (n=24) Major bleeding 8.3% (0.18 EPPY) Severe neurological events 12.5% (0.28 EPPY) Transient neurological events Local infection 8.3% (0.18 EEPY) 20.8% (0.46 EPPY) Despite overcoming a learning curve, the device technology was applied with remarkable outcomes and a low complication rate. Long-term VAD support of more than 2 years reflects the overall trend of extended transplant waiting time. The EXCOR Pediatric VAD has been successfully introduced in Poland with excellent results comparable to other experienced centers throughout the US and Europe. 25 Multicenter and Single Center Studies

Initial Clinical Experience in Japan Review of the interim results of the EXCOR Pediatric clinical study in Japan S. Kyo, What future will bring?, oral communication at ASCVTS 2014 In 2010, the organ transplant laws in Japan were revised and organ donation in children less than 15 years of age became possible. However, organ donation overall is extremely limited in Japan especially in the pediatric population. Longer bridge to transplantation support times with VADs is required for the pediatric population. A pediatric VAD offering safe support for a prolonged period was urgently needed. Since 2012, 4 patients have been supported with the EXCOR Pediatric VAD in Japan within a clinical study. Patient characteristics Variable EXCOR Pediatric patients (n=4) Age in months, Median (range) 78 (4-156) Weight in kg, Median (range) 11 (5-25) INTERMACS level 1 or 2 (%) 100 Preoperative ECMO (%) 50 DCM preoperative diagnosis (%) 100 LVAD type of support (%) 100 26

Outcome The overall median support time was 254 days (146-422 days). The Japanese patients were supported with EXCOR Pediatric for a cumulative time of 1,110 days. Overall survival was 100%, 50% were transplanted and 50% were still on support. 4 Still on support No. Patients 3 2 Transplanted Still on support 1 Transplanted 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Time on device (months) FIGURE 27 Time on device of Japanese patients Two patients have been transplanted and two patients are still on support at 7 months. The initial clinical experience with EXCOR Pediatric in Japan is promising. All patients were either successfully transplanted or are still on support at 7 months. 27 Multicenter and Single Center Studies

The availability of the Berlin Heart at BC Children s Hospital in Vancouver is incredibly exciting. The wait for suitable donor organs in Western Canada can be long. We are now able to bridge children with end-stage heart failure successfully and safely with this wonderful technology. We are very thankful to Berlin Heart for their tremendous support during the infancy of our surgical heart failure program. Sanjiv K. Gandhi, MD, Chief, Pediatric Cardiothoracic Surgery, BC Children s Hospital Berlin Heart GmbH Wiesenweg 10 12247 Berlin Germany Phone +49 30 81 87-26 00 Fax +49 30 81 87-26 01 info@berlinheart.de www.berlinheart.de Berlin Heart Inc. 200 Valleywood Suite B-100 The Woodlands Texas 77380 Phone +1 281 863-97 00 Fax +1 281 863-97 01 info@berlinheart.com www.berlinheart.com The Berlin Heart EXCOR Pediatric Ventricular Assist Device (EXCOR Pediatric) is approved for use by the FDA under a Humanitarian Device Exemption. Version MFE41.2 September 2015