INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

Similar documents
MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

Legacy Prosthetic Catalog

NARROW DIAMETER implant

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

Prosthodontic Procedure

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

MiNi Overdenture Fixture

SimpleLine II Surgical / Prosthesis Manual

SwissPlant Prosthetic Catalog. SwissPlant

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Prosthodontic Procedure

Abutment level impression Ⅰ. Combi abutment/dual abutment Multi units

OT EQUATOR CASTABLE Single Attachment for Overdentures

For the oral rehabilitation

Straight Octagon Abutment for Tissue Level Implant

INTRODUCTION. Why Choose Cortex Prosthetics?

IMPRESSION PROCEDURES TRAINING MANUAL

Multi-Unit Abutment Guide

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

SCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

NEW NEW. An Extended Solution for Narrow Ridges

4766 Research Dr. San Antonio, TX insightdentalsystems.com

Prosthodontic Procedure

GMI. MONOLITH implant system. Surgical procedures guide

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

Biomimetic PEARL. Product catalogue

N E W S M I L E S E V E R Y D AY

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

the perfect fusion Catalogue

NEW. An Extended Solution. for Narrow Ridges

GMI FRONTIER implant system. Surgical procedures guide

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

User Manual Complete Prosthetic Kit (CPK)

Straumann Screw-retained Prosthetics

GmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

SuperLine & Implantium Surgical / Prosthesis Manual

Quick start Prosthetics

NEW. An Extended Solution. for Narrow Ridges

ELSNER SYSTEM OVERVIEW Revolutionary solutions for your implant prosthetic problems

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

Biomimetic Product catalogue

IMPLANTS. Pearls. Your Precious Pearls. Made in Germany

The intelligent system.

CATALOG. Since 1985» Simple. Predictable. Profitable.

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

SuperLine & Implantium Surgical / Prosthesis Manual

NARROW DIAMETER implant

Ankylos. Acuris conometric concept. Manual and product catalog

US Implant System 2013 PROSTHETIC PROCEDURE

Multi-unit abutment open tray technique using the direct pick-up coping

Biomimetic PEARL. Product catalogue

NARROW DIAMETER implant

GUIDED SURGERY TECHNIQUE

Osteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher

isy indications and techniques

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

RePlant System Prosthetic Catalog

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

NEODENT GUIDED SURGERY

Product Catalog. Since 1985» Simple. Predictable. Profitable.

SIMPLE INSERTION, NATURAL STABILITY. Self-cutting capacity in both directions Makes it possible to achieve high primary stability with low torque

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

SS Implant System 2013 PROSTHETIC PROCEDURE

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Guided surgery manual

Dental Implant Catalog All Rights Reserved

Low Profile Neuro Plating System. Surgical Technique

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Instructions for Use DENTAL IMPLANTS

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

Bridging the Gap Between Original and Multi-Platform Systems.

Restoring Straumann implants. with Locator abutments.

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Multi-unit abutment closed tray technique using the indirect transfer coping

BONE LEVEL ABUTMENTS. on4. multi-unit

For technical assistance: Tel Working time: 8.30 am pm

» For multi-unit restorations -

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

- RESTORATIVE PRODUCT CATALOG

TRINON. Index. Index. Overview Page 4. Catalogue

C O M PA N Y P R O F I L E S I N C E W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E

FOR PROFESSIONALS. Product Catalogue. Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

Instructions for Use DENTAL IMPLANTS

How something small, can make such a big difference!! Your best choice in overdenture

PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014

I M P L A N T O L O G Y

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Product Catalog July 2017

HEXAGON Implant System

Where technology meets dentistry INNOVATION. at a GLANCE

IR (INTELLIGENT) INTERNAL ONE-STAGE SYSTEM

IMPLANTS. Y o u r P r e c i o u s P e a r l s

Transcription:

PROSTHESIS MANUAL

INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL REMOVABLE PROSTHESIS OVERDENTURES Pag. 13 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) MICRODENT EKTOS CONICAL (STRAIGHT) WITH FLAP MICRODENT EKTOS CONICAL (STRAIGHT) WITHOUT FLAP MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) MICRODENT EKTOS ANGLED MICRODENT EKTOS MINI CAPITEL MICRODENT EKTOS ANGLED MINI CAPITEL MICRODENT EKTOS OSSCILIA RETENTION LABELING CODE SYMBOLOGY S IMPLANTS INSTRUCTIONS FOR USE MRI SAFETY INFORMATION SURGICAL INSTRUMENTS GUARANTEE PROGRAM Pag. 14 Pag. 15 Pag. 15 Pag. 15 Pag. 15 IMPRESSION TAKING Pag. 08 CHART OF MICRODENT EKTOS S Pag. 16 CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION OPEN TRAY IMPRESSION TAKING CLOSED TRAY IMPRESSION TAKING PROVISIONAL CEMENTED PROSTHESIS SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL Pag. 09 Pag. 10 Microdent Cover screw Microdent Retention screw Microdent Healing abutment Microdent multifunction (straight) abutment Microdent Conical (straight) abutment with flap Microdent Conical (straight) abutment without flap Microdent Immediate loading Conical (straight) abutment Microdent Angled abutment Microdent Mini Capitel abutment Microdent Angled Mini Capitel abutment Microdent Osscilia retention abutment

PRESENTATION Implant Microdent System S.L. is a company that, from its creation in 1983, has specialized in developing, manufacturing and marketing components for odontological treatments, and, specially, oral implantology. Always striving for customer satisfaction, Microdent offers all the guarantee, both of quality and service, backed up by its long and ascending professional history in the field of oral implantology. The periodical offer of formation courses for professionals of the implantology field and the existence of a collaboration and assessment team allows Microdent to have products that verify the most strict quality parameters stablished, as well as to satisfy the needs of its clients. Microdent has modern facilities equipped with the most cutting-edge technology, thus making Microdent into one of the pioneer companies in the research and manufacture of solutions for oral implantology. The patents obtained by Microdent products demonstrate the continued dedication of the company to the research work. 5

Microdent With internal hexagonal connection INTRODUCTION PROSTHESIS MANUAL This manual informs dental practitioners and prosthetists of the different Microdent Implant System abutments available to make a dental prosthesis. This prosthetic manual suggests which Microdent abutment should be used depending on the situation and/or requirements of the patient. The use of the strict protocols described in this manual guarantees the efficacy of the Microdent products. WARNINGS MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. The multifunction abutment is characterized by its multiple functionality: implant holder, transfer and provisional abutment. The multifunction abutment is supplied with the implant and cover screw in their own packaging in a sterile state. The multifunction abutment is connected to the implant through the employment of a prosthetic screw, which is also presented in a sterile state. The upper part of the abutment has a hexagonal socket to accomodate a tool for: - Implant and abutment extraction from the container. - Implant transport from the container to the insertion point. MICRODENT EKTOS CONICAL (STRAIGHT) WITH FLAP A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. 6

MICRODENT EKTOS CONICAL (STRAIGHT) WITHOUT FLAP A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) www.microdentsystem.com A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. MICRODENT EKTOS ANGLED A retention screw is provided in the container with the abutment. Do not to exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cannot be modified. Angled abutments are not recommended for the posterior region of the mouth. MICRODENT EKTOS MINI CAPITEL Use the UTSNLEC / UTSNLEC51 keys to screw the abutment and the implant together. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. MICRODENT EKTOS ANGLED MINI CAPITEL The UTSNATR18 retention screw and the PACN carrier are provided in the container with the angled Mini Capitel abutment. Use the PACN carrier to fix angled Mini Capitel abutment to its desired position. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. MICRODENT EKTOS OSSCILIA RETENTION The use of the hex. 1.20 screwdriver is required to join the product and the implant together. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Do not exceed a disparallelism of 17º between implants. The exchange of retainers is facilitated through the use of the MC220PB screwdriver. The retainers are identified by color. The different colors denote different retentive strengths. - Black retainer = soft retention strength 2Kg. For use in laboratory trials. - White retainer = middle retention strength 3Kg. To keep stable for a long period of time. - Red retainer = strong retention strength 4Kg. Only to be used in special cases where an extreme fixation is required. 7

IMPRESSION TAKING CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION A multifunction abutment can be used for taking impressions with a closed tray. After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression. Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth. Cast the model with type IV clay (ISO 6873) and use silicone if needed. Necessary material HEX. MULTIFUNCTION TRANSFER BALL SCREW IMPLANT ANALOG ANALOG (MH120) CLOSED TRAY OPEN TRAY IMPRESSION TAKING Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area. Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a long or short open tray screw using the MH120 screwdriver. Place the drilled transfer area tray (circular or hexagonal) to test the fit. Make sure the screw heads stand out 1 mm and ensure they are easy to reach after taking the impression. After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression. Unscrew the emerging screws when removing the impression using the MH120 screwdriver. Remove the tray and fix the implant copies very carefully into the impression, then cast the model with type IV clay (ISO 6873). Silicone is recommended when simulating soft tissues. Long transfers (14mm H) will be used when the adjacent teeth have high crown length and when the patient s mouth opening is broad. Short transfers (10mm H) will be used for short crown lengths and small mouth openings. Necessary material HEX. SHORT TRANSFER HEX. LONG TRANSFER OPEN TRAY CIRCULAR SHORT TRANSFER CIRCULAR LONG TRANSFER OPEN TRAY TRANSFER LONG SCREW OPEN TRAY TRANSFER SHORT SCREW IMPLANT ANALOG (MH120) 8

CLOSED TRAY IMPRESSION TAKING Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area. Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a closed tray screw using the MH120 screwdriver and cover the screw with the plastic cap to avoid any silicone from entering. After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression. Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth. Cast the model with type IV clay (ISO 6873) and use silicone if needed. Necessary material www.microdentsystem.com HEXAGONAL TRANSFER TRANSFER SCREW PROTECTIVE CAP IMPLANT ANALOG (MH120) OPEN TRAY CIRCULAR TRANSFER TRANSFER BALL SCREW PROVISIONAL Necessary material Multifunction abutment and/or Immediate loading abutment Multifunction abutments can be used for both single and multiple prosthesis. Use Immediate loading hexagonal abutments for single restorations (they can also be used for multiple prosthesis) and Immediate loading circular abutments for multiple prosthesis. HEX. MULTIFUNCTION TRANSFER BALL SCREW (DL120) MULTIFUNCTION IMMEDIATE LOADING CONICAL HEX. IMMEDIATE LOADING IMMEDIATE LOADING CONICAL CIRCULAR OPEN TRAY TRANSFER LONG SCREW RETENTION SCREW (DL120) 9

CEMENTED PROSTHESIS SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL Conical abutment hexagonal with and without flap Recommended for single prosthesis. The conical abutment can be either with or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. In the conical abutment without flap, the prosthetic crown has to end at 0 mm, in order to lean on the implant platform (like a knife cutting edge). The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created. The conical abutment without flap is recommended when there are less than 2 mm of keratineized gum. This is a situation that can cause a difficult aesthetic situation but it is rectifiable with this kind of abutment. Angled abutment The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º. Available in three different angles (15º, 20º and 25º). To maintain the exact position of the implant connection, a hexagonal connection is used. CONICAL WITH FLAP RETENTION SCREW (DL120) CONICAL HEXAGONAL CONICAL WITHOUT FLAP RETENTION SCREW (DL120) AESTHETIC ANGLED AESTHETIC ANGLED RETENTION SCREW (DL120) Cement the prosthesis with the cement suggested for this kind of restorations 10

MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL Conical abutment circular with and without flap Recommended for multiple prosthesis. The conical abutment can be either with flap or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created. Angled abutment The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º. Available in three different angles (15º, 20º and 25º). www.microdentsystem.com CONICAL WITH FLAP RETENTION SCREW (DL120) CONICAL CIRCULAR CONICAL WITHOUT FLAP RETENTION SCREW (DL120) AESTHETIC ANGLED AESTHETIC ANGLED RETENTION SCREW (DL120) Cement the prosthesis with the cement suggested for this kind of restorations 11

CEMENT-SCREWED PROSTHESIS IMPRESSION TAKING: NECESSARY MATERIAL Mini Capitel abutment transfer and Mini Capitel analog Place the transfer on the Mini Capitel abutment. Proceed to take impressions with an open or closed tray. Once the impression is done, remove the transfer and drag the impression along with the carrier. Place the Mini Capitel analog in the impression. PROSTHESIS: NECESSARY MATERIAL Mini Capitel abutment Recommended for screwed multiple prosthesis. Mini Capitel abutments allow the complete prosthesis to be placed and removed even when the implants are not parallel. It is fixed on the platform of the implant, forming a single compact body without the possibility of rotational motion. It allows a compensation of up to 35º between implants (with no greater than 17.5º compensation for either of the two implants) to remedy disparallelism as well as providing a perfect adjustment and a vertical removal of the prosthesis. Available in different heights: from 1 mm to 4 mm, depending on the platform. For prosthetic restorations with either the Mini Capitel abutment or the angled Mini Capitel abutment, the same prosthetic accessories are used. The angled Mini Capitel abutment has an angle between 17º and 30º and a height of 0 mm and 1 mm. Mini Capitel abutment or angled Mini Capitel abutment Cementable abutment. Closed tray transfer Closed tray retention screw IMPRESSION TAKING MINI CAPITEL TRANSFER MINI CAPITEL Open tray transfer Open tray retention screw ANALOG (DL120) CIRCULAR MINI CAPITEL APPLICATOR MULTIPLE PROSTHESIS MINI CAPITEL MINI CAPITEL OR ANGLED MINI CAPITEL ANGLED HEX. MINI CAPITEL RETENTION SCREW CARRIER CEMENTABLE (DL120) Cementable abutment is common for both Mini Capitel and angled Mini Capitel abutments 12

REMOVABLE PROSTHESIS. OVERDENTURES IMPRESSION TAKING: NECESSARY MATERIAL Osscilia transfer and Osscilia analog Place the transfer on the Osscilia abutment, which is held by an elastic washer. Proceed to take impressions with an open tray. Once the impression is done, remove the tray and drag the impression along with the carrier. Place the Osscilia analog in the impression. www.microdentsystem.com PROSTHESIS: NECESSARY MATERIAL Osscilia abutment The retainer of the abutments for overdenture retention can be easily exchanged by a practitioner. An Osscilia abutment has a reduced prosthetic height and an emergence diameter of only 3.50 mm. The complete ensemble is formed by a metallic cap and three different types of interchangeable retainers that are housed inside the metallic cap. Through the employment of a simple key and the screw, the retainers are fixed. Different colors denote different strengths of retention. Black retainer = soft retention 2 Kg. For use in laboratory trials. White retainer = middle retention 3 Kg. To keep stable for a long period of time. Red retainer = strong retention 4 Kg. Only to be used in special cases when an extreme fixation is required. IMPRESSION TAKING OSSCILIA OVERDENTURES TRANSFER OSSCILIA TRANSFER OSSCILIA ANALOG OSSCILIA (DL120) PROSTHESIS OSSCILIA OVERDENTURES (MC220PB) OSSCILIA OSSCILIA RETENTION + METAL CAP BLACK RETAINER SOFT RETENTION STRENGTH WHITE RETAINER MIDDLE RETENTION STRENGTH RED RETAINER STRONG RETENTION STRENGTH (DL120) 13

LABELING CODE SYMBOLOGY S Images 1: image of primary packaging of a Microdent abutment Images 2: image of secondary packaging of a Microdent abutment IMPLANTS Unique Device Identifier (DI&PI) Device Identifier Manufacturer Implant type Do not re-use Caution, consult accompanying documents Caution: federal law restrics this device to sale by or on the order of a dental professional Endosteal diameter Reference/article number Lot/batch number Do not use if package is damaged Site for Instructions or Use (IFU) review Sterile by irradiation Expiration date Image 3: images of primary packaging (right) and secondary packaging (left) for a Microdent implant Two similar labels are included as guidance for practitioners, inside the implant package 14

INSTRUCTIONS FOR USE In accordance and compliance with legal requirements, all implants manufactured by Implant Microdent System have instructions for use. These instructions are available at www.microdentsystem.com www.microdentsystem.com MRI SAFETY INFORMATION Implants and abutments have not been evaluated for safety and compatibility in the MR environment. Implants and abutments have not been tested for heating, migration, or image artifact in the MR environment. The safety of implants and abutments in the MR environment is unknown. Scanning a patient who has this device may result in patient injury. SURGICAL INSTRUMENTS For a proper use and cleaning of surgical instruments, consult their instructions for use. GUARANTEE PROGRAM Implant Microdent System provides guarantees for the products it distributes. The terms and conditions of these guarantees are indicated in the Microdent Implant System Guarantee Program, consult their instructions for use: www.microdentsystem.com 15

MICRODENT EKTOS S All prosthetic abutments are made in titanium grade 5 MICRODENT EKTOS COVER SCREW Sterilized cover screw supplied in the implant package. Use of a 1.20mm hexagonal screwdriver required. Do not cement the cover screw to the implant. Do not exceed a torque of 5Ncm. EKTC35 Platform 3.50mm EKTC45 Platform 4.50mm EKTC57 Platform 5.70mm MICRODENT EKTOS RETENTION SCREW EKTRHC Screw can be used with different types of prosthesis. Use of a 1.20mm hexagonal screwdriver required. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. MICRODENT EKTOS HEALING EKPCR3502 Ø 3.50 height 2mm EKPCR3503 Ø 3.50 height 3mm EKPCR3504 Ø 3.50 height 4mm EKPCR3505 Ø 3.50 height 5mm Healing abutment EKPCR5702 Ø 5.70 height 2mm EKPCR4502 Ø 4.50 height 2mm EKPCR4503 Ø 4.50 height 3mm EKPCR4504 Ø 4.50 height 4mm EKPCR4505 Ø 4.50 height 5mm This abutment is intended for further use of Osscilia abutments and conical abutments without flap. Abutment supplied in sterile state. Use of a 1.20mm hexagonal screwdriver required. Do not cement the cover screw to the implant. Do not exceed a torque of 25Ncm. 16

EKPR3502 Ø 3,50 height 2mm EKPR3503 Ø 3,50 height 3mm EKPR3504 Ø 3.50 height 4mm EKPR3505 Ø 3.50 height 5mm www.microdentsystem.com Aesthetic Healing abutment EKPR5702 Ø 5.70 height 2mm EKPR4502 Ø 4.50 height 2mm EKPR4503 Ø 4.50 height 3mm EKPR4504 Ø 4.50 height 4mm EKPR4505 Ø 4.50 height 5mm Abutment supplied in sterile state. Use of a 1.20mm hexagonal screwdriver required. Do not cement the cover screw to the implant. Do not exceed a torque of 25Ncm. MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) Multifunction abutment EKPMF35 Ø 3.50 height 0mm EKPMF45 Ø 4.50 height 0mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15 Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. 17

MICRODENT EKTOS CONICAL (STRAIGHT) WITH FLAP Hexagonal EKPCCP3501H Ø 3.50 height 1mm EKPCCP3503H Ø 3.50 height 3mm EKPCCP3505H Ø 3.50 height 5mm Conical abutment hexagonal with flap EKPCCP5701H Ø 5.70 height 1mm EKPCCP4501H Ø 4.50 height 1mm EKPCCP4503H Ø 4.50 height 3mm EKPCCP4505H Ø 4.50 height 5mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. Circular EKPCCP3501R Ø 3.50 height 1mm EKPCCP3503R Ø 3.50 height 3mm EKPCCP3505R Ø 3.50 height 5mm Conical abutment circular with flap EKPCCP5701R Ø 5.70 height 1mm EKPCCP4501R Ø 4.50 height 1mm EKPCCP4503R Ø 4.50 height 3mm EKPCCP4505R Ø 4.50 height 5mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. 18

MICRODENT EKTOS CONICAL (STRAIGHT) WITHOUT FLAP Hexagonal www.microdentsystem.com EKPCSP3500H Ø 3.50 height 0mm EKPCSP3501H Ø 3.50 height 1mm EKPCSP3502H Ø 3.50 height 2mm EKPCSP3503H Ø 3.50 height 3mm EKPCSP3504H Ø 3.50 height 4mm EKPCSP3505H Ø 3.50 height 5mm Conical abutment hexagonal without flap EKPCSP4500H Ø 4.50 height 0mm EKPCSP4501H Ø 4.50 height 1mm EKPCSP4502H Ø 4.50 height 2mm EKPCSP4503H Ø 4.50 height 3mm EKPCSP4504H Ø 4.50 height 4mm EKPCSP4505H Ø 4.50 height 5mm EKPCSP5700H Ø 5.70 height 0mm EKPCSP5701H Ø 5.70 height 1mm The screw can be used with all the different types of abutments. Use of a 1.20mm hexagonal screwdriver required. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. 19

Circular EKPCSP3500R Ø 3.50 height 0mm EKPCSP3501R Ø 3.50 height 1mm EKPCSP3502R Ø 3.50 height 2mm EKPCSP3503R Ø 3.50 height 3mm EKPCSP3504R Ø 3.50 height 4mm EKPCSP3505R Ø 3.50 height 5mm Conical abutment circular without flap EKPCSP4500R Ø 4.50 height 0mm EKPCSP4501R Ø 4.50 height 1mm EKPCSP4502R Ø 4.50 height 2mm EKPCSP4503R Ø 4.50 height 3mm EKPCSP4504R Ø 4.50 height 4mm EKPCSP4505R Ø 4.50 height 5mm EKPCSP5700R Ø 5.70 height 0mm EKPCSP5701R Ø 5.70 height 1mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) HEXAGONAL CIRCULAR Immediate loading conical abutment EKPCI3500H Ø 3.50 height 0mm EKPCI4500H Ø 4.50 height 0mm EKPCI5700H Ø 5.70 height0mm EKPCI3500R Ø 3.50 height 0mm EKPCI4500R Ø 4.50 height 0mm EKPCI5700R Ø 5.70 height 0mm Abutment supplied with a retention screw. Use the EKTUCI screw for impression taking when using immediate loading abutments. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. 20

MICRODENT EKTOS ANGLED EKPAE3515H Ø 3.50 / 15º EKPAE3520H Ø 3.50 / 20º EKPAE3525H Ø 3.50 / 25º www.microdentsystem.com Hexagonal Aesthetic Angled abutment (height 0mm) EKPAE5715H Ø 5.70 / 15º EKPAE5720H Ø 5.70 / 20º EKPAE5725H Ø 5.70 / 25º EKPAE4515H Ø 4.50 / 15º EKPAE4520H Ø 4.50 / 20º EKPAE4525H Ø 4.50 / 25º Abutment supplied with the corresponding screw. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. MICRODENT EKTOS MINI CAPITEL EKCAPN3501R Ø 3.50 height 1mm EKCAPN3502R Ø 3.50 height 2mm EKCAPN3503R Ø 3.50 height 3mm EKCAPN3504R Ø 3.50 height 4mm Circular Mini Capitel abutment EKCAPN5701R Ø 5.70 height 1mm EKCAPN5702R Ø 5.70 height 2mm EKCAPN4501R Ø 4.50 height 1mm EKCAPN4502R Ø 4.50 height 2mm EKCAPN4503R Ø 4.50 height 3mm EKCAPN4504R Ø 4.50 height 4mm Screw in the abutment using the UTSNLEC key. Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. 21

MICRODENT EKTOS ANGLED MINI CAPITEL ANGLED 17º ANGLED 30º EKCAPNA35170H Ø 3.50 height 0mm EKCAPNA35171H Ø 3.50 height 1mm EKCAPNA35300H Ø 3.50 height 0mm EKCAPNA35301H Ø 3.50 height 1mm Hexagonal angled Mini Capitel abutment EKCAPNA45170H Ø 4.50 height 0mm EKCAPNA45171H Ø 4.50 height 1mm EKCAPNA45300H Ø 4.50 height 0mm EKCAPNA45301H Ø 4.50 height 1mm Abutment supplied with UTSNATR18 retention screw and PACN positioner. Use the PACN positioner to facilitate the desired fixation of the abutment. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Do not exceed a torque of 15Ncm for prosthetic retention screws. 22

Microdent Mini Capitel and Angled Mini Capitel abutment components MICRODENT EKTOS MINI CAPITEL FIXING KEY UTSNLEC Standard platform Material: Stainless steel UTSNLEC1 Wide platform Material: Stainless steel MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL CEMENTABLE UTSNPC4X Standard platform Material: Titanium grade 5 UTSNPC51 Wide platform Material: Titanium grade 5 www.microdentsystem.com Mini Capitel cementable copings cannot be milled. MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROTECTIVE CAP MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROSTHETIC RETENTION SCREW UTSNCP4X Standard platform Material: Titanium grade 5 UTSNCP51 Wide platform Material: Titanium grade 5 UTSNTR Standard platform Material: Titanium grade 5 + DLC UTSNTR1 Wide platform Material: Titanium grade 5 + DLC Do not exceed a torque of 15Ncm for prosthetic retention screws. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. PACN Angled Mini Capitel abutment carrier Material: Stainless steel UTSNATR18 Angled Mini Capitel retention screw Material: Titanium grade 5 + DLC These two components are supplied together in the same set with the angled Mini Capitel abutment. Use of a 1.20mm hexagonal screwdriver required. Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. 23

MICRODENT EKTOS OSSCILIA RETENTION EKEOSS3500 Ø 3.50 height 0mm EKEOSS3501 Ø 3.50 height 1mm EKEOSS3502 Ø 3.50 height 2mm EKEOSS3503 Ø 3.50 height 3mm EKEOSS3504 Ø 3.50 height 4mm EKEOSS4500 Ø 4.50 height 0mm EKEOSS4501 Ø 4.50 height 1mm EKEOSS4502 Ø 4.50 height 2mm EKEOSS4503 Ø 4.50 height 3mm EKEOSS4504 Ø 4.50 height 4mm Osscilia retention abutment EKEOSS5700 Ø 5.70 height 0mm EKEOSS5701 Ø 5.70 height 1mm Use of a 1.20mm hexagonal screwdriver required to fix the implant. Do not exceed a torque of 30Ncm. Do not exceed a maximum non-parallelization of 15 from the vertical. CSUTGOSS Metal cap with soft, middle and strong retainers Material: Titanium grade 5 + POM MC220PB Microdent Osscilia retainer screwdriver Material: Stainless steel Metal cap with soft, middle or strong Osscilia retainer Available with three different retention levels, identified by a colored plastic cap: - Black plastic cap: supplied with an embedded metal sheath, it has a soft retention for clinical or laboratory tests. - White plastic cap: it has a medium retention very appropriate to keep stable during a long time period. - Red plastic cap: used in specific cases where extreme fixation is required. The key for the Osscilia retainers is a MC220PB. 24