Databehandling. 3. Mark e.g. the first fraction (1: 0-45 min, 2: min, 3; min, 4: min, 5: min, 6: min).

Similar documents
MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

How to Use TOF and Q-TOF Mass Spectrometers

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

SimLipid 3.5. Manual PREMIER. Biosoft International Corina Way, Palo Alto, CA Tel: (650) FAX: (650)

Moving from targeted towards non-targeted approaches

Top 10 Tips for Successful Searching ASMS 2003

Unsupervised Identification of Isotope-Labeled Peptides

SIEVE 2.1 Proteomics Example

Lipid annotation with MS2Analyzer. Yan Ma 10/24/2013

QSTAR Operation. May 3, Bob Seward

Preparations. Planmeca Romexis Smile Design Quick guide. Capture 2D photo(s) Start Romexis Smile Design software

Don t miss a thing on your peptide mapping journey How to get full coverage peptide maps using high resolution accurate mass spectrometry

Primary Structure Analysis. Automated Evaluation. LC-MS Data Sets

Probability-Based Protein Identification for Post-Translational Modifications and Amino Acid Variants Using Peptide Mass Fingerprint Data

SimGlycan. A high-throughput glycan and glycopeptide data analysis tool for LC-, MALDI-, ESI- Mass Spectrometry workflows.

Nature Biotechnology: doi: /nbt Supplementary Figure 1

Proteomics of body liquids as a source for potential methods for medical diagnostics Prof. Dr. Evgeny Nikolaev

Supporting Information. Lysine Propionylation to Boost Proteome Sequence. Coverage and Enable a Silent SILAC Strategy for

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Actiwatch. Clinician Guide

Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

TMWSuite. DAT Interactive interface

AB Sciex QStar XL. AIMS Instrumentation & Sample Report Documentation. chemistry

Lecture 3. Tandem MS & Protein Sequencing

NON TARGETED SEARCHING FOR FOOD

Charts Worksheet using Excel Obesity Can a New Drug Help?

Fully Automated IFA Processor LIS User Manual

Dividing up the data

Mass Spectrometry. Mass spectrometer MALDI-TOF ESI/MS/MS. Basic components. Ionization source Mass analyzer Detector

Identification of Haemoglobinopathies by LC/MS

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

Managing and Taking Notes

for the Identification of Phosphorylated Peptides

ERI User s Guide. 2. Obtaining the ERI for research purposes

Workflows in SIEVE and LipidSearch

Clay Tablet Connector for hybris. User Guide. Version 1.5.0

Comparison of mass spectrometers performances

Managing and Taking Notes

Lionbridge Connector for Hybris. User Guide

Patients & Physicians

Figure HN-5-L1: The Sequence menu containing the preprogramming light sequences used in this experiment.

Creating YouTube Captioning

Agilent Lipidomics. Workflow Guide. MS Data Qualitative Workflow. With MS/MS ID Confirmation. Find features in one file by MFE in MH Qual.

Experiment HH-2: The Electrocardiogram and Heart Sounds

Proteome Discoverer Version 1.3

LC-MS. Pre-processing (xcms) W4M Core Team. 29/05/2017 v 1.0.0

Accurate determination of protein methionine oxidation by stable isotope labeling and LC-MS analysis

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

PedCath IMPACT User s Guide

Mass spectra of peptides and proteins - and LC analysis of proteomes Stephen Barnes, PhD

NIH Public Access Author Manuscript J Proteome Res. Author manuscript; available in PMC 2014 July 05.

Cancer Rates and Cement Plants 1

Characterization of an Unknown Compound Using the LTQ Orbitrap

Amadeo R. Fernández-Alba

Quantification with Proteome Discoverer. Bernard Delanghe

Shotgun Proteomics MS/MS. Protein Mixture. proteolysis. Peptide Mixture. Time. Abundance. Abundance. m/z. Abundance. m/z 2. Abundance.

Content Part 2 Users manual... 4

SUPPORTING INFORMATION. Lysine Carbonylation is a Previously Unrecognized Contributor. to Peroxidase Activation of Cytochrome c by Chloramine-T

2. Ionization Sources 3. Mass Analyzers 4. Tandem Mass Spectrometry

LC/QTOF Discovery of Previously Unreported Microcystins in Alberta Lake Waters

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Automating Mass Spectrometry-Based Quantitative Glycomics using Tandem Mass Tag (TMT) Reagents with SimGlycan

Biological Mass spectrometry in Protein Chemistry

Titrations in Cytobank

Unit 1: Introduction to the Operating System, Computer Systems, and Networks 1.1 Define terminology Prepare a list of terms with definitions

ATLANTIS WebOrder. ATLANTIS ISUS User guide

Protein Investigator. Protein Investigator - 3

PosterREPRINT AN AUTOMATED METHOD TO SELF-CALIBRATE AND REJECT NOISE FROM MALDI PEPTIDE MASS FINGERPRINT SPECTRA

CEU MASS MEDIATOR USER'S MANUAL Version 2.0, 31 st July 2017

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

User Guide. Protein Clpper. Statistical scoring of protease cleavage sites. 1. Introduction Protein Clpper Analysis Procedure...

Characterization of Disulfide Linkages in Proteins by 193 nm Ultraviolet Photodissociation (UVPD) Mass Spectrometry. Supporting Information

Unbiased in-depth characterization of CEX fractions from a stressed mab by MS. Matthias Berg, Novartis Pharma, BTDM

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Warning: Avoid putting the tip of the syringe needle too deeply into the hole to avoid damage to the heart tissue.

iworx Sample Lab Experiment HC-3: Pulse Wave Velocity

AudBase Guidebook Application How-To

DENTRIX ENTERPRISE 8.0.5

The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

User Guide for Classification of Diabetes: A search tool for identifying miscoded, misclassified or misdiagnosed patients

Biomolecular Mass Spectrometry

Double charge of 33kD peak A1 A2 B1 B2 M2+ M/z. ABRF Proteomics Research Group - Qualitative Proteomics Study Identifier Number 14146

SANAKO Lab 100 STS USER GUIDE

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Quadrupole and Ion Trap Mass Analysers and an introduction to Resolution

BlueBayCT - Warfarin User Guide

Estimating national adult prevalence of HIV-1 in Generalized Epidemics

General Single Ion Calibration. Pete 14-May-09

UWA ERA Publications Collection 2011

MASS SPECTROMETRY BASED METABOLOMICS. Pavel Aronov. ABRF2010 Metabolomics Research Group March 21, 2010

Learning Objectives. Overview of topics to be discussed 10/25/2013 HIGH RESOLUTION MASS SPECTROMETRY (HRMS) IN DISCOVERY PROTEOMICS

Table of Contents Morning Set-up (GSI equipment, only)... 2 Opening AudBase... 3 Choosing a patient... 3 Performing Pure-Tone Air & Bone

Experiences with application of full scan high resolution MS for pesticide residue analysis

UPLC-HRMS: A tool for multi-residue veterinary drug methods

Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry

Dementia Direct Enhanced Service

New Instruments and Services

Cardiac Agatston Scoring

Transcription:

Databehandling Data analysis 1. Choose Open in the Data analysis window. 2. Press the Open folder and choose the desired analysis. Click the + button, so that the Chromatograms line appears. Click the + on this line so the TIC±All line appears. 3. Mark e.g. the first fraction (1: 0-45 min, 2: 45-90 min, 3; 90-135 min, 4: 135-180 min, 5: 180-225 min, 6: 225-270 min). 4. Check and mark TIC ± All. 1. Choose Find in the Toolbar parameters Parameters: a) AutoMS(n) parameters Intensity threshold: 50 000 Retention time window (min): 0.75 (Note: computer might not understand comma, use period. ) Spectrum type (Line/Profile): Profile spectra only Background subtraction (MS only): None Do not choose Create individual AutoMS (n) chromatogram traces. b) Mass List parameters Choose Apex page Peak width (FWHM) (m/z): 0.1 S/N threshold: 0.1 Relative intensity threshold (base peak): 0 Absolute intensity threshold: 0.1 Choose Use peak finder to calculate peak position. c) Charge Deconvolute parameters

Choose peptide/small molecules Adduct ions: +H (first window) and H (second window) Deconvolute: choose Full scan, MS MaxRes Scan, MS(n) Low mass: 215 100 215 High mass: 1800 3000 2000 (1500) Abundance cutoff (%): 5 2 Resolved-isotope deconvolution Maximum charge: 3 3 2 Choose Related-ion deconvolution (MS full scan only). Max charge: 4 Min peak in set.3 MW agreement (0.01 %): 5 Choose clear previous results d) Mascot export options parameters Choose Set global charge limitation (2+ and 3+) Mixed list (non-deconvoluted and deconvoluted) Keep the other parameters unchecked! Press OK! 2) Choose Find in the toolbar Compounds-AutoMS(n) 3) Select and mark Compounds mass spectra so it is highlighted in blue 4) Choose Masslist in the toolbar Find 5) Choose Deconvolute Mass Spectra 6) In the downer left corner, all the peaks with selected information is displayed. If you want to select other information, right click in the window and choose layout, here you can choose between many different parameters (choose retention time and m/z in these experiments) 6) File Export Compounds and save the file as mgf. file 7) File Export Compounds and save the file as csv. File

Excel File Open and choose the csv.file The data will appear on the screen but in a messy way. Sort the data Mark the column Data in the upper toolbar Text to column make sure Delimited is checked Next Finish Remove the peak number so it wont disturb the comparison of the m/z Start at the top with the first mass find and replace (Ctrl H) are there many masses, then it is just garbage and not necessary to save replace them with 0 are there few peaks with that m/z and in several fractions compare the retention time approximately the same retention time it is probably a peptide mark the numbers red. When all fractions are compared and hopefully some m/z are marked red, go to the next step! Data analysis Mark the fraction you have found a potential peptide which is marked red (right click and drag, so the fraction is highlighted black). Choose Find in the toolbar Parameters (control that the parameters are set correctly, take a look in the upper section of this document to see the values of the Parameters). Choose Find CompoundsMS(n). The retention time and MS(n) isolation mass will appear down at the screen. If the data does not appear on the screen, choose Window Compounds List. In the left side of the screen under Analysis list, open the menu Compounds Mass Spectra and mark the Peak number with the m/z of interest and open the menu of that compound and mark e.g MS/MS (MS 2(631.4)) or mark the line with wanted retention time and m/z in the compound list.

Analysis list File Export Mass Spectrum Save as bsc.file (e.g. make a folder for each fraction and choose the m/z value as filename). Open BioTools! BioTools Open BioTools by Start All programs Bruker Daltonics BioTool File Open (open the wanted file) The mass spectrum will appear in a own window at the screen and some of the signals are marked red all of the signals must be marked red To mark the signals red: Right click in the window Choose Add peaks left click and drag over the black signals and they will become red. If you want to remove some red signals for some reasons Right click choose Remove peaks right click and drag to make red signals to black! Choose the MS icon MS If you have run a tryptic digestion choose MS (missing cleavage is normally 1 or 2).

In the page: a) URL: http://www.matrixscience.com/cgi/nph-mascot.exe?l b) Taxonomy: Rodentia (Rodents) (limit the search to only some species). c) Database: MSDB (eller NCBInr) these are very broad and free databases and not that good. We are using MSDB! SwissProt: better database, but only for the human genome. d) Enzyme: None e) Fixed modification: No! Do not mark neither of these f) Variable modification: No! Do not mark neither of these g) Peptide tolerance: ± 2 Da h) MS/MS : ± 1.5 Da i) Protein mass: leave open j) Charge state: + 2 (this number is transferred to the software by it self) k) m/z : 631.4 (this number is transferred to the software by it self) l) Inst: ESI-TRAP m) Report top: 20 hits (up to 100 hits, since we do not have the license). n) Press START and the data will be transferred to Mascot! Mascot 1) Format as: peptide summary 2) There will be a list with e.g. 20 proteins, depending on the parameters sat before the Mascot transfer (see BioTools part m), like this:

Search Selected Error tolerant 1. Q6WGI1_TRYBO Mass: 68445 Score: 61 Queries matched: 2 Heat shock protein 70 (Fragment).- Trypanoplasma borreli. Check to include this hit in error tolerant search Que ry Obser Mr(expMr(cal ved t) c) 152 875.7 900 179 961.3 000 2624.32623.2 482 303 2880.82879.1 782 628 De Mi lta ss Sco re Exp Ra ect nk Peptide 1.1 179 0 25 24 1 K.SQVFSTYADNQPGVHIQVYEGER.A 1.7 0 36 1.9 1 K.MYQAGGGGGMPGGMPGGMPGGMPGGMP 153 GGIPGG.- + 3 Oxidation (M) BioTool If the program is not already open Start All programs Bruker Daltonics BioTool Open the spectrum (bsc.file) File Open Spectrum Open Sequence Editor in the upper Toolbar (Window Start Sequence editior).

Click on the icon at the left in the upper toolbar and the sequence will automatically be copied in the sequence editor page. If the sequence is not copied in the Sequence Editor automatically, copy the sequence, but not the flang amino acids, and paste it in the page. To get information about b and y-ions, press Bio at the toolbar (both a, b and y ions will appear). http://www.ionsource.com/tutorial/denovo/denovotoc.htm and http://www.ionsource.com if you get 5 b and/or y ions that is good! (You can trust the a,b and y-ions. If you have the a ion and not the b ion, just add 28 Da (C=O) to the a ion and you have the b-ion). R1-Rx are called w-ions 1) Tolerance: 2 (use 2 in these experiments, when the tolerance is increased the score of the result is also increased). When increasing the tolerance from 1 to 2, more y-ions were detected. 2) Calculate: Masses 3) Threshold: 0.0 4) Check Monoisotopic 5) Do not check Average

(Choose View in the toolbar View MS/MS results then you will obtain the new and perhaps increased score. According to Albena, this score is more reliable than the Mascot score.) Choose Window in the toolbar and Show/Hide Treeview. A window will appear in the left of the screen with the Biotools score If you want to examine if there are any a/b-17 (NH3) or a/b-18 (water), choose the y- and b- button in the toolbar The Biotool score can be improved by a) choosing Oxidation (M) and pyro-glu (N-term Q) and pyro-glu (Nterm E) (tar med begge fordi man vet ikke hva som er på hvilken ende) as variable modifications b) choosing Missing cleavage mix : 2 (it is normally 1) c) if Biotool detect phosphoro

Quantification Data analysis Open the TIC for the wanted analysis Open the SIM for the specific ion if there are several peaks with the specific m/z check the mass spectrum and if necessary send the MS/MS spectrum to Mascot and control if the same peptide sequence appear as the original m/z. If the peak shape is poor, improve the shape by changing the m/z value to the exact mass (e.g. SIM of 631.4 but the chromatography shows that the most abundant m/z is 630.6 make a SIM of 630.6 and compare the peak shape). Mark the SIM file Integrate the peak manually, by choosing the icon then the peak area, retention time (RT) and range (pluss other parameters) appear at the end of the screen. Excel Open Excel Write the retention time and peak area of the internal standard (IS). If the compounds are separated into several peaks, sum the peak areas together and calculate the sample concentration by dividing the sample peak area with the area of the internal standard.

Normalize the concentration to 100 mg, then it is easier to compare the concentrations (e.g. µg/mg brain * 100 mg). If the retention time of the internal standard varies a lot, normalize the retention time as well ( e.g. tr/tr (IS)). Reporting Peak number Retention time m/z Concentration Normalized concentration Bartosz: m/z value and peptide sequence