BR-CN151 Audio Compressor Nebulizer
Features: -Unique design with Audio shape -For treatment of upper and lower respiratory -Operation smoothly and quietly -Perfect in craftsmanship with high level quality -Design with integrated handle, easy with carry - Bi-rich patented products -Color available : White/ Blue /Green Specifications & Technical datas: 1. Power: AC 230 V-50Hz or 120V -60Hz 2. Input Power :160VA or 180VA 3. Rate Current: 0.7A or 1.5A 4. Max Capacity of Medicine cup: 6ml (cc) 5. Average Nebulization Rate: 0.25ml/min (0.9% Saline Solution) 6.Mode of Operation: continuous >24 hours 7.Max Working Pressure : 35 Psi ( 345Kpa; 3.5 Bar ) 8.Operation Pressure Range: 9-16 Psi ( 62-110Kpa; 0.6-1.1 Bar ) 9.Liter Operation flow: 5-8 LPM 10.Noise: 55 db(a) ( at 1 meter distance ) 11. MMAD: 3.0 μm(0.9% saline/ tested by Cascade Impactor ) 12.Unit Size: 170 X 100 X 210 MM 13.Unit Weight: 1.27 KG 14. Operation Condition: +5 to +40, 15% RH to 93% RH
15.Suggested Applications : Hospital, clinic, atomizer room, nursing home, personal homecare. 1) Description: 2) Feature: 3)Specification: 4) Accessory: Items NO. BR-CN151 Audio Compressor Nebulizer Strong air flow Low noise Easy operation Easy handle and cleaning Excellent quality with good price Small size and light weight Nice gift box packing Power supply: AC110V/60Hz, 220V/50Hz-60Hz, Working pressure range: 35 to 50 psi Average nebulization rate: 0.33ml/min Product Size: 17 cm x 10 cm x 21cm Weight: 1.27 KGS Max capacity of medicine cup:6ml 1.5M air tube Mouthpiece Nosepiece Child mask 5pcs Air filter 6CC medicine cup 5)Manufacturer: Name: Shenzhen Bi-rich Medical Devices CO., Ltd.
Main Products: Compressor Nebulizer Services: ODM / OEM / According Sample 6) Warranty: Two years 7) Certification: ISO13485 CE 8) Sample: Available Delivery within 2 days Products All of our products are 100% same as the photos, what you see is what you get! All the products we offer have high quality and competitive price. Service and support : Sample Availability & Policy Free sample cost and the freight Guarantees/Warranties/Terms and Conditions 100% ensure our product quality and we provide one year guarantee.
Export/Import Processing Support Strictly inspection before send goods to appointed warehouse or container,we can support customer to ship the goods from Shenzhen to the destination which customer defined, and we have the right to export. After Sales Service Export/import processing support. Logistic support service will be provided to buyers if needed. We promise all feedback or complained would be settled within 24 hours OEM /ODM We accept OEM /ODM orders for all our product lines, including the client's logo, giftbox design, labels and package. Shenzhen Bi-rich Medical Devices Co., Ltd, specialized in the development, production and sales of Medical Nebulizer Devices. We manufacture the compressor nebulizer from purchasing, mold injection, air compressor motor, finished nebulizer,
assembly and packing, everything is in our own factory and under control. We always keep good quality, prompt delivery, best service and reliable cooperation for global valued customers Main product: Piston Compressor Nebulizers, air compressor motor, Sunction phlegm machine and so on.
Home Aerosol Treatment Bi-rich nebulizer, which is powered by an air compressor, has been prescribed by your doctor to deliver medicines and moisture to your air passages. The medicines and moisture help control your respiratory symptoms (such as wheezing) and help loosen secretions in the lungs. The instructions of this Bi-rich Nebulizer will help you correctly perform the procedure and operate the equipment safely. Your health care provider will tell you how often you need to perform this treatment. What supplies do I need? You will need the following supplies: Hand-held nebulizer Air compressor Mouthpiece or face mask Clean measuring devices (enough for each solution used in your treatment) Eyedropper or syringe to measure the medicines Where should the nebulizer be used? Use the nebulizer in a well-lighted area. Select a comfortable place in your home where you can take your treatment without being interrupted. Sit in a comfortable, straight-backed chair when taking your treatment. Place the compressor on a sturdy surface that will support its weight, such as a table or desk. Plug the compressor's cord into a properly grounded (three-pronged) outlet. Treatment procedure Wash your hands with soap and water, and dry them with a clean towel. Measure your medicine. o Always wash your hands before preparing the treatment. o Always use clean measuring devices (eyedroppers or syringes). o Use a separate measuring device for each solution used in your treatment.
o Measure your medicines exactly as you have been instructed. o Wash your hands after measuring each solution used in your treatment. 1. Remove the top part of the nebulizer cup. 2. Place the medicine in the bottom of the nebulizer cup. 3. Attach the top portion of the nebulizer cup, and connect the mouthpiece or face mask to the cup. Connect the tubing to the nebulizer and compressor. Turn on the compressor with the on/off switch.
4. Once you turn on the compressor, you should see a light mist 5. If you are using a mouthpiece, place it in your mouth and seal your lips tightly around it. 6. If you are using a face mask, position it comfortably and securely on your face. Inhale slowly and deeply. Hold your breath for a count of five and exhale slowly. Continue to inhale slowly and deeply for about five to 10 minutes or until the medicine is gone. If you become dizzy, shaky, or feel an increased heart rate, stop your treatment and rest for about five minutes. Then continue the treatment, but breathe more slowly. If these symptoms continue, call your health care provider. Turn the compressor off and unplug it. Take several deep breaths and cough. Continue coughing and try to clear any secretions you might have in your lungs. Cough the secretions into a tissue and dispose of it properly. Wash your hands with soap and water, and dry them with a clean towel.
Cleaning and disinfecting procedure Always clean the equipment in a smoke-free and dust-free location, away from open windows. Clean the equipment after house-cleaning (especially after vacuuming and dusting). Make sure the compressor is turned off and unplugged. After each treatment Take apart the nebulizer cup and mouthpiece or mask. Rinse these parts with warm tap water. NOTE: There is no need to clean the tubing that connects the nebulizer to the air compressor. Shake off the excess water and place the parts on a clean, dry towel. Allow the parts to air dry thoroughly. After the last treatment of the day Take apart the nebulizer cup and mouthpiece or mask. Wash these parts with warm soapy water using a mild detergent. Rinse all parts with warm water. Shake off the excess water and place the parts on a clean, dry towel. Allow the parts to air dry thoroughly. Every third day after washing the equipment Mix a solution of one part vinegar and three parts water in a clean bowl. Soak the nebulizer cup and mouthpiece or mask in the solution for 20 minutes. Rinse the parts well with warm tap water. Shake off the excess water and place the parts on a clean, dry towel. Allow the parts to air dry thoroughly. Equipment storage Compressor Cover your air compressor with a clean towel.
Keep the compressor on a sturdy surface that will support its weight. Do not store the compressor on the floor. Check your compressor's filter once a month. Replace it if it's dirty. Unscrew the filter cap, remove the old filter and replace it with a new one. Always keep an extra filter in case you need it. Your health care provider can supply the filters for you. Nebulizer Reassemble the clean nebulizer parts and store them in a small bag between treatments. Always keep an extra nebulizer in case you need it. Medicine storage Store all of your medicines in a cool, dry place. Check your medicines often. Make sure they have not changed color or formed crystals. If you notice any changes in the appearance of your medicines, throw them away. Ask your health care provider to refill your prescription. Troubleshooting Check the following if your unit should fail during operation. You can also refer to the pages of this manual for complete instructions. Problem Cause Remedy Nothing happens when the power switch is pressed. No nebulisation or low nebulisation rate,when the power is on. Is the AC adapter connected correctly to the an electrical outlet and the compressor? Is there medication in the medication tank? Is there too much/little medication in the medication tank? Is the vaporiser head missing and not assembled correctly? Is the nebulizer kit assembled correctly? Check that the plug is inserted in an electrical outlet. Unplug then reinsert the plug if necessary. Add the correct amount of medication to the medication tank. Attach the vaporiser head correctly. Assemble the nebulizer kit correctly.
The device is abnormally loud. The device is very hot. 深圳市百瑞琪仪器设备有限公司 Is the nozzle blocked? Is the nebulizer kit tilted at a sharp angle? Is the air tube connected correctly? Is the air tube folded or damaged? Is the air tube blocked? Is the air filter dirty? Is the air filter cover attached correctly? Is the compressor covered? Is the device operating continuously over 20 minutes? Make sure that the nozzle is free of blockages. Make sure that the nebuliser kit is not tilted at an angle of more than 45 degrees. Make sure that the air tube is correctly connected to the compressor and nebuliser kit. Make sure that the air tube does not contain kinks. Make sure that the air tube is free of blockages. Replace the air filterwith a new one. Attach the air filter cover correctly. Do not cover the compressor with any type of cover during use. Limit use to 20 minutes at a time, and allow a 40 minutes interval before using the device again. Note: If the suggested remedy does not solve the problem, do not try to repair the device- no parts of the unit are user serviceable. Return the unit to an authorized Bi-rich retail outlet or distributor. Warranty certificate for Bi-rich nebulizer ShenZhen Bi-rich Medical Devices Co.,Ltd warrants our nebulizer to be free from defective workmanship and materials for a period of (1) years from the date of purchase. Check with your dealer or more details. This warranty is limited to the original purchaser of the compressor. Any defective part or assembly will be repaired or replaced, at the sole discretion and determination of ShenZhen Bi-rich Medical Devices Co.,Ltd.if the unit has been properly operated during the warranty period. Normal maintenance items and disposable components are not covered by this warranty.shipping charges, if any,shall be paid by the purchaser.