THE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT

Similar documents
Indications for use. Contraindications within the United States

All-In-One. Iliac Branch System. PER F ORM ANC E b y d e s i g n ILIAC BRANCH ENDOPROSTHESIS

Durable outcomes. Proven performance.

Talent Abdominal Stent Graft

Challenges with Complex Anatomies Advancing Care in Endovascular Aortic Treatment

Optimal Treatment of Chronic Dissection

Objective assessment of current stent grafts: which graft for which lesion. Ludovic Canaud, MD, PhD Pierre Alric, MD, PhD Montpellier, France

A New EVAR Device for Infrarenal AAAs

Treatment of complex thoracic cases Focus on the new Gore Active Control TAG device

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Low profile TEVAR: is it an added value? Michel Bosiers, G. Torsello Münster

Zenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up

LOWERING THE PROFILE RAISING THE BAR

GORE TAG Thoracic Endoprosthesis ANNUAL CLINICAL UPDATE SEPTEMBER 2018 Abstract. Section I GORE TAG Device Clinical experience. Section II Conformable

Tips and Tricks to Deliver a Stengraft to the Ascending Aorta

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

We Catch. What Others Miss

European Experience with a New Thoracic Device. D.Böckler University Hospital Heidelberg Germany

Introducing the GORE TAG Conformable Thoracic Stent Graft with ACTIVE CONTROL System

Access More Patients. Customize Each Seal.

Innovating for life. CardioVascular LifeLine Customer Support Tel: Tel:

FROM THE EVERYDAY TO THE EXTRAORDINARY

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Arch Repair with the Bolton Medical RelayBranch Thoracic Stent-graft system: Multicenter experience

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

The evolution. AORFIX AAA Stent Graft now with the new AORFLEX Delivery System

Conformable Gore TAG Thoracic Endoprosthesis for the treatment of thoracic aortic aneurysms

Aortic stents, types, selection, tricks in deployment.

GORE EXCLUDER AAA Endoprosthesis ANNUAL CLINICAL UPDATE OCTOBER Section I Clinical experience. Section II Worldwide commercial experience

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Endoanchor-assisted TEVAR

thoracic stent graft system Smallest delivery profile as from 20 F

How to achieve a successful proximal sealing in TEVAR? Pr L Canaud

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

Percutaneous Approaches to Aortic Disease in 2018

-vita THORACIC 3G. Stent Graft System SOLUTIONS FOR VASCULAR DISEASE

My personal experience with INCRAFT in standard and challenging cases

Right Choice for Right Angles

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

Title. Different arch branched devices are available, is morphology the. main criteria of choice? Ciro Ferrer, MD

Hostile Proximal Neck: A New Conformable EVAR Device

Proven Performance Through Innovative Design *

Acute dissections of the descending thoracic aorta (Debakey

Balloon Expandable Covered Stents. Suddenly a Crowded Space

Current Status of Abdominal Aortic Stent Grafts. John R. Laird Professor of Medicine Director of the Vascular Center UC Davis Medical Center

TriVascular Ovation Prime Abdominal Stent Graft System

Durability of The Endurant Stent-Graft through 5 Years

Finally, the Control You Need to Deliver Accurate Treatment

Vascular V12. Covered Stent. The New Standard of Care

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Cook Medical. Zenith Flex AAA Endovascular Graft with Z-Trak Introduction System Physician Training

Maximize Control. Minimize Migration.

Endovascular Management of Thoracic Aortic Pathology Stéphan Haulon, J Sobocinski, B Maurel, T Martin-Gonzalez, R Spear, A Hertault, R Azzaoui

Abdominal and thoracic aneurysm repair

Aortic Arch pathology options: Open,Hybrid, fenestration, Chimney or branched stent-graft?

EVAR replaced standard repair in most cases. Why?

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Santi Trimarchi, MD, PhD Vascular Surgeon Thoracic Aortic Research Center, Director IRCCS Policlinico San Donato University of Milan

Endovascular aortic stent grafts have forever

FLEXIBLE, BALOON EXPANDABLE

MAXIMIZE RADIAL SOLUTIONS TO PERIPHERAL CHALLENGES

Expanding to every demand: The GORE VIABAHN VBX Stent Graft

Current State of Thoracic Branch Devices and Ongoing Clinical Trials

Hostile Neck During EVAR, The Role Of Endoanchores

Challenging anatomies demand versatility.

Anatomical challenges in EVAR

Technique and Outcome of Laser Fenestration For Arch Vessels

Going the distance: Conformable Gore TAG device demonstrates durable outcomes over the long. D.Böckler University Hospital Heidelberg, Germany

Left subclavian artery (LSA) coverage during

Development of a Branched LSA Endograft & Ascending Aorta Endograft

Robert F. Cuff, MD FACS SHMG Vascular Surgery

CoreValve Evolut R Technology review and Clinical Results. Paul TL Chiam

Zenith Alpha T HORACIC ENDOVASCULAR GRAFT

Performance of the conformable GORE TAG device in Type B aortic dissection from the GORE GREAT real world registry

First in Human Experience with the Gore Conformable Excluder Endoprosthesis

ABDOMINAL XT ABDOMINAL STENT GRAFT SYSTEM

Clinical experience with a new thoracic stent graft system (Ankura TM ). Procedural analysis, 30 days and 6-month results in a single center study

Re-interventions after TEVAR:

Endovascular treatment of aortic arch using Relay branched stent grafts

VALIANT THORACIC STENT GRAFT WITH THE CAPTIVIA DELIVERY SYSTEM 2016 ANNUAL PHYSICIAN CLINICAL UPDATE

US AORTIC PRODUCT CATALOG

DISCLOSURES ISOLATED DTA LESION? TYPE B DISSECTIONS TREATMENT OPTIONS

Cite this article as:

Pioneering EVAR techniques in aortic dissection

Changing Spectrum of Re-Interventions following TEVAR. 31 st Annual Florida Vascular Society. PENN Surgery

EXPERIENCE AFTER 500 ENDOLUMINAL STENT GRAFTS. DEVICES SPECIFIC OUTCOME AND LESSONS LEARNED.

Evolution of gender-related differences in outcome of EVAR

Challenges. 1. Sizing. 2. Proximal landing zone 3. Distal landing zone 4. Access vessels 5. Spinal cord ischemia 6. Endoleak

Accessi Iliaci Ostili

Anatomy and Classification of Aortic Dissection

Malperfusion Syndromes Type B Aortic Dissection with Malperfusion

Modified candy-plug technique for chronic type B aortic dissection with aneurysmal dilatation: a case report

Considerations for a Durable Repair

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

Ascending Aorta: Is The Endovascular Approach Realistic?

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

Endovascular Repair of Aortic Arch/Thoracic Aneurysms: Bolton RelayBranch Device

Transcription:

THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise

THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous anatomy. Optimized aortic wall apposition in angulated arch anatomy without excessive radial force, barbs, or bare springs Conforms and achieves better graft contact in curved segment of the aorta Minimizes the risk of damaging or perforating aortic tissue Designed to treat etiologies of the descending thoracic aorta including aneurysms, transections, and dissections Unique 6 33% oversizing range enables an optimal radial fit, whether treating a young trauma patient or a fragile dissected aorta Off-the-shelf tapered devices allow proximal to distal aortic diameter variance of up to 9.5 mm to be treated with a single device Compression resistant Maintains patency in small diameter thoracic aortas Stent design maintains wall apposition in angulated arch anatomy without compromising tissue integrity No reports of compression with more than 4,000 devices implanted 1

Radial Fit Physician can select oversizing based on patient anatomy for optimal conformability and customized radial fit. Conformable GORE TAG Device * 21 26 28 31 34 37 40 45 The 16 42 mm range can be treated with as few as five sizes. 20 Device Diameter (mm) Medtronic VALIANT Device * 22 24 26 30 28 32 COOK ZENITH TX2 Device with PRO-FORM * 26 24 22 28 30 32 34 36 36 34 38 38 40 40 42 42 44 46 94 85 Complete Inventory Bolton RELAY Plus Device * and Bolton RELAY NBS Device 24 22 26 28 30 32 34 36 40 38 42 44 46 82 RELAY Plus 58 RELAY NBS 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Intended Range of Aortic Diameters (mm) * Assumes rounding of measured vessel diameter (mm) to nearest whole number within IFU sizing range. The only thoracic endograft engineered to perform in 6 33% oversizing conditions Broad 16 42 mm aortic diameter treatment range with as few as five sizes Expanded device diameter range accommodates a wider range of aortic anatomies Only commercially available endograft approved to treat patients with 16 mm thoracic aortas Tapered aortas may be treated with a single straight device Off-the-shelf tapered designs Provides physicians with more options to match the endograft to the individual patient anatomy

CONFORMABILITY without COMPROMISE Advances the tradition of performance and durability. 3 2 5 4 1 5

1 Partially Uncovered Stent Helps achieve 360 wall apposition in angulated anatomy Eliminates potential damaging barbs or flared bare springs 2 Radiopaque Gold Bands Gold bands are located on both proximal and distal ends of graft Aids in accurate device positioning and visualization at patient follow-up 3 Increased Wire Diameter and Nine Apex Pattern Compression-resistant design Allows for increased 6 33% oversizing range Increased radial force while maintaining adequate fatigue life Maintains radial strength and achieves wall apposition in angulated arch anatomy 4 Sutureless Construction Eliminates risk of graft failure from sutures eptfe graft technology on luminal and abluminal surfaces 5 Sealing Cuffs Engineered to provide increased security against endoleaks 2 Optimized eptfe Film Layers Leverages 35 years of experience with eptfe and a reliable platform with proven clinical durability and strength Low permeability with abrasion-resistant properties Optimizes graft and film layers to maximize durability and conformability Reinforcing Film Low Permeability Film eptfe Graft

PERFORMANCE FACTS ELEGANTLY Simple DESIGN Flexible Low-Profile Design Low-profile delivery catheter provides flexibility while navigating anatomy in the aortic arch Single-Sheath Insertion No re-insertion is necessary if additional devices are required Minimizes vessel trauma and the potential for rupture with multiple sheath insertions Sheathless Delivery Catheter Facilitates passage and access through tortuous thoracic anatomy Reduces deployment force Single-Step Deployment System Easy, single-step, twist and pull deployment Radiopaque Modified Olive Engineered to enhance trackability and deliverability of the device

For more than 15 years, the GORE TAG Device has demonstrated impressive success in both clinical studies and real-world commercial use. More than 59,000 Devices Distributed Worldwide For more than a decade, we have worked alongside physicians in the evolution of the GORE TAG Device. Our collaboration has resulted in the distribution of more than 59,000 devices for the treatment of more than 34,700 patients worldwide. Proven Clinical Results The GORE TAG Device is supported by more than 15 years of TEVAR experience and clinical data with up to five years of follow-up. Most Studied Thoracic Endograft Available With the first implant occurring in 1997, the GORE TAG Device has been studied in ten FDA approved clinical studies, one European clinical trial, and one European registry. Thirty-Five Years of Experience with eptfe Graft Material Having pioneered eptfe graft technology 35 years ago, Gore continues to collaborate with physicians and scientists to create a robust and reliable design platform based on proven clinical performance.

Conformable GORE TAG Thoracic Endoprosthesis Catalogue Number Intended Aortic Diameter (mm) Proximal Diameter (mm) Distal Diameter (mm) Length (cm) Recommended GORE DrySeal Sheath Size (Fr) GORE DrySeal Sheath Outer Diameter (mm) TGE212110 16 19.5 21 21 10 18 6.8 TGE262110 19.5 24 / 16 19.5 26 21 10 20 7.5 TGE262610 19.5 24 26 26 10 20 7.5 TGE282810 22 26 28 28 10 20 7.5 TGE282815 22 26 28 28 15 20 7.5 TGE312610 24 29 / 19.5 24 31 26 10 22 8.3 TGE313110 24 29 31 31 10 22 8.3 TGE313115 24 29 31 31 15 22 8.3 TGE343410 27 32 34 34 10 22 8.3 TGE343415 27 32 34 34 15 22 8.3 TGE343420 27 32 34 34 20 22 8.3 TGE373710 29 34 37 37 10 24 9.1 TGE373715 29 34 37 37 15 24 9.1 TGE373720 29 34 37 37 20 24 9.1 TGE404010 31 37 40 40 10 24 9.1 TGE404015 31 37 40 40 15 24 9.1 TGE404020 31 37 40 40 20 24 9.1 TGE454510 34 42 45 45 10 24 9.1 TGE454515 34 42 45 45 15 24 9.1 TGE 454520 34 42 45 45 20 24 9.1 GORE DrySeal Sheath with Hydrophilic Coating GORE Tri-Lobe Balloon Catheter Catalogue Number Sheath Size (Fr) Catalogue Number Aortic Diameter (mm) DSL1828 18 BCM1634 16 34 DSL2028 20 BCL2645 26 42 DSL2228 22 DSL2428 24 DSL2628 26 All sheaths are 28 cm in length. W. L. Gore & Associates, Inc. Flagstaff, AZ 86004 +65.67332882 (Asia Pacific) 00800.6334.4673 (Europe) 800.437.8181 (United States) 928.779.2771 (United States) goremedical.com 1 Data on file. Products listed may not be available in all markets. COOK, PRO-FORM, TX2, and ZENITH are trademarks of COOK Medical, Inc. RELAY is a trademark of Bolton Medical. VALIANT is a trademark of Medtronic, Inc. GORE, C3, EXCLUDER, PERFORMANCE BY DESIGN, TAG, and designs are trademarks of W. L. Gore & Associates. 2013 W. L. Gore & Associates, Inc. AR1299-EU2 FEBRUARY 2013 GORE 3D Imaging System GORE EXCLUDER Device featuring C3 Delivery System Choose radial fit over radial force. Products listed may not be available in all markets. COOK, TX2 and ZENITH are trademarks of COOK Medical, Inc. CAPTIVIA, TALENT, and VALIANT are See trademarks why of at Medtronic, conformabletag.com Inc. GORE, PERFORMANCE BY DESIGN, TAG, and designs are trademarks of W. L. Gore & Associates. 2012 W. L. Gore & Associates, Inc. AR1248-EU1 JANUARY 2012