MICROBIAL EXPOSURE AND MOLD SPECIFIC SERUM IGG LEVELS OF SYMTOMATIC SCHOOLCHILDREN

Similar documents
CONCENTRATIONS OF VIABLE FUNGAL SPORES ON PAPER DOCUMENTS

MOLDS IN THE INDOOR ENVIRONMENT: Implications for Children s Health. Eugene C. Cole, DrPH Brigham Young University

Profiles of Airborne Fungi in Buildings and Outdoor Environments in the United States

Profiles of Airborne Fungi in Buildings and Outdoor Environments in the United States

FUNGAL GROWTH ON BUILDING MATERIALS AND LEVELS OF AIRBORNE FUNGI IN HOMES

Poultry fungal contamination as a public health problem

THE USE OF DNA TESTING IN MOULD INVESTIGATIONS ANN DORTE PØRNEKI, M.SC.

Microbiomes of the Built Environment: Homes

Introduction: PCR Air Sampling: November 12, Carrie E Tompkins Elementary School PCR Fungi Study:

M. A. CECIL & ASSOCIATES, INC Shannon Way, Port Republic, Maryland (301) INDUSTRIAL HYGIENE AND ENVIRONMENTAL HEALTH

Effects of mould remediation on school teachers health

Overdiagnosis and Public Health: Inventing an Epidemic in Moldy Montreal Schools

Mycotech Biological, Inc.

Facts about Stachybotrys chartarum and Other Molds

MSES consultants, inc.

DNA-Based Analyses of Molds in Singapore Public Buildings Results in a Proposed Singapore Environmental Relative Moldiness Index

Changes in pro-inflammatory cytokines in association with exposure to moisture-damaged building microbes

Department of Environmental Science, University of Eastern Finland, Kuopio, Finland. Department of Public Health, University of Helsinki, Finland

Moisture damage and childhood asthma: a population-based incident case control study

EVALUATION OF THE CYCLEX IMPACTOR PHASE 2: REPORT 3

Energy & Environmental Solutions, Inc. Mold Facts/Fiction/Who Knows

Certificate of Mold Analysis

MSES consultants, inc.

Thermotolerant filamentous fungi in belgian hospitals: 15 years of survey

Dealing With Dampness in Buildings

Nasal symptoms among residents in moldy housing

Air fungal contamination in ten hospitals food units from Lisbon

VARIANT INDOOR FUNGAL LEVELS IN RESIDENTIAL ENVIRONMENTS FOLLOWING A CLEANING INTERVENTION ON CARPETS AND SOFT FURNISHINGS

The CAP Method for Assessing Surface Dust Samples for Mold

MSES consultants, inc.

MICROBIOME OF ENCLOSED AIR IN SELECTED DORMITORIES IN UNIVERSITY OF PORT HARCOURT

Fungal DNA health studies and patient cases

This is the author s version of a work that was submitted/accepted for publication in the following source:

Influence of Environmental Parameters on Mold Sampling Results

Emil J. Bardana, Jr., M.D. Oregon Health Sciences University

Legally Defensible Strategies for Mold Investigations

Tape Lift and Swab Sampling of Items found at Glenwood Middle School Project #J15-876

Dampness, bacterial and fungal components in dust in primary schools and respiratory health in schoolchildren across Europe

January 31, Mr. Mark LaFleur Director of Plant Operations Town of Needham 1330 Highland Avenue Needham, MA 02492

Moisture damage and childhood asthma a population-based incident case-control

Certificate of Mold Analysis

Potential Health Effects of Mold Exposure in Buildings

Certificate of Mold Analysis

TOXICOLOGY AND RISK ASSESSMENT OF MYCOTOXINS

CHILDREN LIVING IN HOMES WITH PROBLEMS OF DAMP

MOULDS ASSOCIATED WITH MILK DEPENDING ON MACROCLIMATE AND GEOGRAPHICAL LOCATION

Ergosterol Content in Various Fungal Species and Biocontaminated Building Materials

Certificate of Mold Analysis

Certificate of Mold Analysis (941) (941) SAMPLE REPORT

RLB CIH, LLC. Final Report Microbial Contamination Sampling Taos Recreation Center Taos, New Mexico. March 9, 2007

Quantitative, Real-Time Polymerase Chain Reaction Analysis

Workshop: Hurricanes and Mold July 23, :00PM -4:30PM Savin Rock Conference Center West Haven, CT 06516

A Healthy Home, LLC West Center Dr. Lakewood, CO

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Certificate of Mold Analysis

Mould Allergy. Patient Information

Exposure to Moulds in Flats and the Prevalence of Allergic Diseases Preliminary Study

Protect your biggest investment. Live healthier. Because you re not only buying a home, you're also buying the air in it.

Certificate of Mold Analysis

Certificate of Mold Analysis

Health risk assessment of fungi in home environments

Comments: Your Results

Index. Immunol Allergy Clin N Am 23 (2003) Note: Page numbers of article titles are in boldface type.

Comparison of fungal contamination between hospitals and companies food units

Certificate of Mold Analysis

Adverse Health Effects Associated with the Indoor Air Quality of Flood-Damaged Structures

Fungi Isolated from Flue-cured Tobacco at Time of Sale and After Storage1

1251 Weatherstone Ct. Reston,VA Mold Reduction Report

Overcoming the Barriers to Establishing Quantitative Health Guidance Values for Airborne Mold 2019 IAQA Annual Meeting

A study of fungi in air in selected areas of Visakhapatnam city, India

Certificate of Mold Analysis

MOLD INSPECTION REPORT

IAQ Mold Concerns. CAPT Don Hagen, USN, MS, CIH Navy Marine Corp Public Health Center

Incorporation of microbiological and molecular methods in HACCP monitoring scheme of molds and yeasts in a Greek dairy plant: A case study

Comparison of indoor and outdoor fungi and particles in poultry units

Certificate of Mold Analysis

INT J CURR SCI 2012, SHORT COMMUNICATION ISSN A study of air microflora in selected areas of Visakhapatnam

Certificate of Mold Analysis

WHAT DOES MOLD MEAN? J&M Environmental Control Group 14 Monarch Bay Plaza, #470 Monarch Beach, CA 92629

Certificate of Mold Analysis

Literature Building Mold Sampling Report

Exposure to bio-aerosols in indoor and occupational settings

HEALTH EFFECTS OF INDOOR FUNGAL BIOAEROSOL EXPOSURE

Research Article The Relationship between Mold Exposure and Allergic Response in Post-Katrina New Orleans

Review article: Manchester Special Issue Accepted: Occupational Exposure to Moulds in Buildings. Jagjit Singh

Dr Toni Gladding Open University

Certificate of Mold Analysis

Cornell Waste Management Institute. Compost Air Emissions Health Studies

Forensic Analytical Environmental Services Division The Case of the Phantom Mold

Fungi in the Air of Hospital Wards

Aeromycological analysis of allergenic airborne fungi in Qazvin, Iran

Detection of Fungi Spectrum in Industrial and Home Bakeries and Determinated Fungal Allergy with Skin Prick Test

Fungal Contamination in Public Buildings: Health Effects and Investigation Methods

Non-commercial use only

Specific fungal exposures, allergic sensitization, and rhinitis in infants

Analysis Report prepared for Quest Air

Quantitative, Real-Time Polymerase Chain Reaction Analysis

Certificate of Analysis

Transcription:

MICROBIAL EXPOSURE AND MOLD SPECIFIC SERUM IGG LEVELS OF SYMTOMATIC SCHOOLCHILDREN A Hyvärinen 1, T Husman 1, S Laitinen 2, T Meklin 1, T Taskinen 3, M Korppi 4 Nevalainen 1 and A 1 National Public Health Institute, Kuopio, Finland 2 Kuopio Regional Institute of Occupational Health, Kuopio, Finland 3 Kiuruvesi Health Care Center, Kiuruvesi, Finland 4 Kuopio University Hospital, Kuopio, Finland ABSTRACT The association between serum mold-specific IgG levels of 181 primary schoolchildren with asthma or wheezing or cough symptoms and the microbial exposure were determined. The study was conducted in a school with mold damage and in another without such damage. Microbial exposure was characterized with environmental sampling. Serum IgG antibody concentrations to 20 microbial strains were determined with ELISA. There was an association between elevated serum IgG levels to Penicillium notatum and moisture damage in the school. In addition, moisture damage when present both in school and at home was associated with elevated IgG levels to Penicillium notatum and Eurotium amstelodami. These observations were in concordance with microbial findings in the index school. No other positive associations between IgG antibodies and microbial findings of the school buildings were observed; in fact, the microbe-specific IgG levels of children were often higher in the reference school. INDEX TERMS Microbial exposure, Moisture damage, IgG, Schoolchildren, Respiratory symptoms INTRODUCTION Technical or self-reported observations of dampness and mold in buildings have often been used as criteria for indoor microbial exposure in epidemiological studies (Peat et al. 1998). In short-time air sampling of viable microbes differences in concentrations and composition of microbes have been associated with moisture problems in a building (Hyvärinen et al. 1993, Hyvärinen et al. 1999). However, a linear association between symptoms and concentrations of viable fungi or bacteria is seldom found (Verhoeff and Burge 1997). An indirect monitoring of the exposure with serum microbe-specific immunoglobulin G (IgG) antibodies represents an attractive possibility. Mold-specific IgG levels have been shown to be a competent tool for exposure assessment in occupational environments with high microbial concentrations, such as in sawmills and agriculture (Eduard et al. 1992, Erkinjuntti- Pekkanen 1996). However, there is a lack of knowledge whether serum mold-specific IgG actually reflects exposure in sites with much lower bioaerosol concentrations e.g. in schools and private homes. The aim of this study was to evaluate whether there is an association between serum mold-specific IgG levels of schoolchildren and the microbial exposure in their school environment. Contact author email: anne.hyvarinen@ktl.fi 404

MATERIAL AND METHODS Buildings studied The study was conducted in two primary schools, which were categorized as a moisture damaged (index) school and a non-damaged (reference) school based on observations of moisture and mold in a thorough technical investigation by civil engineers. The standardized protocol has been described in detail by Nevalainen et al. (1998). The index school had frequent signs of moisture in its structures, mostly due to leaks in roofs and plumbing, missing or inadequate drainage and construction defects in the insulation. Visible mold was also observed in some parts of the school. The reference school had a few minor signs of moisture, assessed to be consequences of normal aging of the building. Study population A total of 212 children with respiratory symptoms, 170 from the index school (41 %) and 42 from the reference school (20%) were selected (Taskinen et al. 1999). From these, 181 (85%) children gave a blood sample for immunoglobulin G analyses and thus formed the cohort of this study; 148 (82%) came from the index school and 33 (18%) from the reference school. Microbial characterization Concentrations of airborne mesophilic fungi were determined with six-stage impactors (Andersen 10-800) on 2% malt extract agar (MEA) (Biokar, Beuvais, France) with streptomycin and on dichloran glycerol agar (DG18) (Oxoid, Basingstoke, England) with chloramphenicol. Tryptone yeast glucose (TYG) medium (Difco, Le Ponte Claix, France) with cycloheximide was used for mesophilic bacteria. Samples (10 min) were taken in the middle of the room at a height of 1-1.5 m in 20 different rooms in the index school and in 17 rooms in the reference school. Sampling was performed during the school day with normal activity and during wintertime when the outdoor air microbial levels are low due to snow cover (Reponen et al. 1992). Samples for fungi were incubated at 25 º C for 7 d. Fungal colonies were identified morphologically at genus using an optical microscope. In addition, Aspergillus versicolor, Aspergillus fumigatus, Aspergillus niger and Aspergillus glaucus were identified at the species level. Bacterial samples were incubated in the dark at 20-23 º C for 5 d and the total number of colonies was counted. The number of dryish actinobacteria type colonies was counted after 14 days. Concentrations (colony forming units per cubic meter, cfu/m 3 ) were calculated using flow rate, sampling time and the correction table for multiple impactions on individual sites (Andersen 1958). Surface samples were taken from both index (n=23) and reference (n=14) buildings and samples of damaged building materials (n=23) during the dismantling and renovation of the index building. Samples from damaged surfaces were taken with a sterile swab into sterile Tween 80 dilution buffer (distilled water with 42.5 mg/l KH 2 PO 4, 250 mg/l MgSO 4 x 7H 2 O, 8 mg/l NaOH and 0.02% Tween 80 detergent). Reference samples were taken from corresponding, undamaged, clean surfaces. The sampling area was 100 cm 2 for damaged surfaces and 200 cm 2 for undamaged surfaces. A series of dilutions were prepared and plated on MEA, DG18 and TYG as in the air sampling. Building material samples were weighed, homogenized and extracted with sterile Tween 80 dilution buffer. Suspensions were held in an ultrasonic bath for 30 minutes and in a shaker for 60 minutes. Dilution series were made and plated on MEA, DG18 and TYG media as described above. Antibody determination The serum samples were stored at 20 º C until all the serum samples were collected. The samples were analyzed blinded in a random order. Serum IgG antibodies were determined to 405

19 fungal strains, and three 1 actinobacterial strain, including the most common molds found in moisture damage buildings. Intracellular antigens for antibody determination were prepared from microbial cultures as described by Laitinen et al. (1999). The working dilutions of antigens were determined from the titration curves for each microbe separately by using IgG positive sera diluted 1:100. Serum immunoglobulin G (IgG) antibody concentrations were determined by an enzyme-linked immunosorbent assay (ELISA) (Laitinen et al. 1999). In the ELISA, the absorbance values of a test serum were compared to those of a pooled control serum collected from 321 adults positive to a few molds/microbes. The control serum was used on each microtiter plate. Absorbances produced by a test serum are expressed as percentages from the absorbances of the corresponding microbes produced by the positive reference serum. Statistics Concentrations of fungi and bacteria were not normally distributed and the data were analyzed with non-parametric tests. Differences in fungal and bacterial concentrations between the index and reference schools were analyzed using Wilcoxon s test. The differences in the occurrence of low/elevated mold specific IgG-levels were first tested with chi-square and Fisher s exact tests and the effects of confounding factors were adjusted with a logistic regression analysis. A serum antibody level was defined as elevated if it exceeded the 75 percentile of IgG concentrations for the corresponding microbe in the whole present study population. The SAS statistical was used for all analyses (SAS 1990). RESULTS Microbial results Total concentrations of airborne viable fungi varied between <4 130 (GM MEA =21 cfu/m 3, GM DG18 =24 cfu/m 3 ) and <4-250 cfu/m 3 (GM MEA =4 cfu/m 3, GM DG18 =7 cfu/m 3 ) in the index school and reference school, respectively. Total concentrations of viable fungi, and the concentrations of Penicillium and yeasts grown on both media were significantly higher in the index school than in the reference school. Concentrations of actinobacteria were <11 cfu/m 3 in both schools (GM index =0.7 cfu/m 3, GM reference =0.1 cfu/m 3 ). The occurrence of fungal genera, to which IgG antibodies were determined, in indoor air, surface and building material samples are presented in Table 1. All of the fungal types of the reference school were also found in the index school. In addition to the fungi in the Table 1, there were fungi that were only detected in the index school: Alternaria, Aspergillus niger, Chrysosporium, Exophiala, Hyalodendron, Monocillium, Mucor, Oidiodendron, Olpitrichum, Phialophora and Scopulariopsis. Microbe-specific immunoglobulin G antibodies More children with elevated antibody levels came from the reference school than from the index school (Table 1); the difference was significant for Stachybotrys chartarum and Rhodotorula glutinis. In contrast, 28 children in the index school had elevated IgG levels to Penicillium notatum and Eurotium amstelodami (p=0.052 vs reference school). Some compatibility between elevated serum IgG levels of Penicillium notatum and Eurotium amstelodami (Table 1) and measured microbial exposure was observed in higher levels of Penicillium and the more frequent occurrence of Eurotium in the index school (Table 1). Instead, the higher IgG levels to Stachybotrys chartarum, Rhodotorula glutinis (Table 1), in the reference school were not in concordance with microbial findings (Table 1). 406

Table 1. Occurrence of fungal genera or groups and actinobacteria in air, building material and surface samples (x = found xx = found in $5 air samples) in the index and reference school. The results are shown in relation to number (%) of children with an elevated IgG level. Microbe Index Reference B Air Material Surface IgG A Air Surface IgG A n (%) n (%) Actinobacteria xx x 35 (24) 1 x 11 (33) 1 Acremonium x x x 35 (24) 2 x 11 (33) 4 Aspergillus xx x x xx x Aspergillus fumigatus x x 37 (25) x 9 (27) Aspergillus versicolor x x x 38 (26) x 8 (24) Aureobasidium pullulans x x x 37 (25) x 9 (27) Cladosporium xx x x 34 (23) x 12 (36) Eurotium xx x 42 (28) O x x 4 (12) Fusarium x 39 (26) 7 (21) Geotrichum 34 (23) 12 (36) Mucor x x 36 (24) 10 (30) Paecilomyces x x x 37 (25) 9 (27) Penicillium xx x x 42 (28) 3O xx x 4 (12) 3 Rhizopus x 37 (25) 9 (27) Sphaeropsidales group x x 36 (24) 4 x 10(30) 4 Sporobolomyces 34 (23) 12 (36) Stachybotrys x 32 (22) 14 (42)* Trichoderma x x 37 (25) x 9 (27) Tritirachium x 35 (24) 11 (33) Yeasts (white and pink) xx x x 32 (22) 5 xx x 14 (42) 5 * Proceedings: Indoor Air 2002 A = A serum antibody level was defined as elevated if it exceeded the 75 percentile of IgG concentrations for the corresponding microbe in the whole study population; B = no material samples; 1 = Streptomyces albus; 2 = Acremonium atrogriseum; 3 = Penicillium notatum; 4 = Phoma macrostoma (belongs to Sphaeropsidales group); 5 = Rhodotorula glutinis (belongs to yeasts) * p<0.05 versus the index school children; O p=0.05 versus the reference school children 407

The associations between moisture damage in school, at home or at both places and moldspecific IgG levels were analyzed also with the logistic regression. Age, gender, housing mode, having pets, passive smoking, asthma and atopy (allergic rhinitis, allergic conjunctivitis or atopic eczema) were included in the model. The analyses confirmed the significant association between moisture damage in the school and elevated IgG levels to Penicillium notatum (p<0.05). In addition, elevated IgG to Penicillium notatum (p<0.01) and Eurotium amstelodami (p<0.05) were significantly associated with moisture damage both in the school and at home. The negative associations between elevated IgG to Stachybotrys chartarum or Rhodotorula glutinis and moisture damage in the school remained significant. DISCUSSION The two school buildings were defined as a moisture damaged (index) school and as a reference school according to objective technical investigations with a structured protocol performed by a civil engineer (Nevalainen et al. 1998). According to the results of microbial measurements, concentrations of airborne viable fungi were higher in the index than in the reference school. In addition, the index school had higher concentrations of Penicillium and yeasts, and a larger diversity of fungal genera. There were only two IgG findings that supported the hypothesis that indoor exposure increases mold-spefic IgG levels: the higher proportion of children with elevated IgG levels in the index school to Penicillium notatum and Eurotium amstelodami. This is in line with preliminary findings among adults published by Makkonen et al. (2001). On the contrary, most of the IgG-levels in the reference schoolchildren with no school-related exposure in the sense of the microbial findings were similar to the index school, or even higher as was seen in IgG to Stachybotrys chartarum and Rhodotorula glutinis. Hence, it can be concluded that elevated IgG-levels of schoolchildren with respiratory symptoms were predominantly not associated with measured microbial exposure or observed technical findings of moisture damage in the school building. This finding is supported by similar studies concerning homes and schools (Hyvärinen et al. 1999, Taskinen et al. 2001), and in a study carried out in an office environment (Malkin et al. 1998). However, this disagrees with observations performed in adults working in environments such as in agriculture and sawmills (Eduard et al. 1992, Erkinjuntti-Pekkanen 1996, Bünger et al. 2000), and among workers of a water-damaged military hospital (Seuri et al. 2000), where exposure to mold has been related with serum IgG levels. The study population was selected based on respiratory symptoms and therefore, the results cannot be extrapolated to the general child population. The IgG levels found in the serum reflect the total life-time exposure to microbes. The development of IgG antibodies is not sufficiently known. Young children spend only about 4-6 hours per weekday in the school, and so, other exposures, especially at home, outdoors and in previous life may play an important role in the development of mold-specific IgG antibodies. In conclusion, an association between elevated serum IgG antibodies to Penicillium notatum and moisture damage in the school was found among schoolchildren with respiratory symptoms and allergic diseases. In addition, there were associations between elevated IgG levels to Penicillium notatum and Eurotium amstelodami and moisture damage when present both in school and at home. Serum IgG antibodies in the children to other microbes did not, however, correlate with the microbial findings of the school buildings. Measurement of IgG antibodies from schoolchildren cannot be recommended as a routine method for assessment of building moisture-related microbial exposure. 408

ACKNOWLEDGEMENTS The technical support of Mika Toivola, Virpi Koponen, Juho Halla-aho, Jari Koivisto and laboratory staff of National Public Health Institute is greatly appreciated. The authors also thank the laboratory staff of the Kuopio Regional Institute of Occupational Health for their assistance with serum IgG antibody analyses. REFERENCES Andersen, A.A 1958. New sampler for the collection, sizing and enumeration of viable airborne particles, Journal of Bacteriology 76:471-484. Bünger J, Antlauf-Lammers M, Schulz TG et al. 2000. Health complaints and immunological markers of exposure to bioaerosols among biowaste collectors and compost workers. Occup Environ Med 57:458-464. Eduard W, Sandven P, Levy F 1992. Relationships between exposure to spores from Rhizopus microsporum and Paecilomyces variotii and serum IgG antibodies in wood trimmers. Int Arch Allergy Immunol 97:274-282. Erkinjuntti-Pekkanen R 1996. Long-term outcome of farmer s lung - Pulmonary function, serology, radiologic findings on HRCT, and socioeconomic outcome of FL patients and matched controls. Ph.D. Thesis, Kuopio University Publications D, Medical sciences 111, Kuopio University Printing Office, Finland. Hyvärinen A, Reponen T, Husman T et al. 1993. Characterizing mold problem buildings concentrations and flora of viable fungi. Indoor Air 3:337-343. Hyvärinen A, Reiman M, Meklin T et al. 1999. Fungal exposure and IgG-levels in houses with and without mold problems. In Johanning (Ed.), Proceedings of Conference on Bioaerosols, Fungi and Mycotoxins: Health Effects, Assessment, Prevention and Control, Saratoga Springs, New York, 1999, pp. 166-168. Laitinen S, Linnainmaa M, Laitinen J et al. 1999. Endotoxins and IgG antibodies as indicators of occupational exposure to the microbial contaminants of metal-working fluids. Int Arch Occup Environ Health 72:443-450. Makkonen K, Viitala KI, Parkkila S et al. 2001. Serum IgG and IgE antibodies against moldderived antigens in patients with symptoms of hypersensitivity. Clinica Chimica Acta 305:89-98. Malkin R, Martinez K, Marinkovich V et al. 1998. The relationship between symptoms and IgG and IgE antibodies in an office environment. Environ Research, Sect. A 76:85-93. Nevalainen A, Partanen P, Jääskeläinen E et al. 1998. Prevalence of moisture problems in Finnish houses. Indoor Air Suppl. 4: 45-49. Peat JK, Dickerson J, Li J 1998. Effects of damp and mould in the home on respiratory health: a review of the literature. Allergy 53:120-128. Reponen T, Nevalainen A, Jantunen M et al. 1992. Normal range criteria for indoor air bacteria and fungal spores in a subarctic climate. Indoor Air 2:26-31. SAS Institute Inc 1990. SAS Procedures Guide, Version 6, 3 rd edition, Cary,NC, USA. Seuri M, Husman K, Kinnunen H et al. 2000. An outbreak of respiratory diseases among workers at a water-damaged building a case report. Indoor Air 2000; 10:138-145. Taskinen T, Hyvärinen A, Meklin T et al. 1999. Asthma and respiratory infections in school children with special reference to moisture and mold problems in the school. Acta Paediatr 88: 1373-1379. Taskinen T, Laitinen S, Nevalainen A et al. 2002. Immunoglobulin G antibodies to moulds in schoolchildren from moisture problem schools. Allergy (in press). Verhoeff AP, Burge HA 1997. Health risk assessment of fungi in home environments. Annals of Allergy, Asthma and Immunology 78:544-556. 409