Citation for published version (APA): Dijkstra, M. L. (2018). Advances in complex endovascular aortic surgery [Groningen]: University of Groningen

Similar documents
Endovascular aneurysm repair (EVAR) for the

Volume 3 (2017) Issue 1 ISSN Abstract. Keywords fenestrated after open repair; Pararenal abdominal aortic aneurysm.

FEVAR FIFTEEN YEARS OF EFFICIENCY E.DUCASSE MD PHD FEBVS CHU DE BORDEAUX

Mid-term results of endovascular aneurysm repair with branched and fenestrated endografts.

Treatment options of late failures of EVAS. Michel Reijnen Rijnstate Arnhem The Netherlands

GORE EXCLUDER AAA Endoprosthesis demonstrates long-term durability. Michel Reijnen Rijnstate Hospital Arnhem, The Netherlands

Robert F. Cuff, MD FACS SHMG Vascular Surgery

Bilateral use of the Gore IBE device for bilateral CIA aneurysms and a first interim analysis of the prospective Iceberg registry

Durable outcomes. Proven performance.

The Ventana Off-the-Shelf Graft for Pararenal AAA. Andrew Holden Associate Professor of Radiology Auckland Hospital

EVAR replaced standard repair in most cases. Why?

Citation for published version (APA): Tielliu, I. F. J. (2010). Endovascular repair of peripheral artery aneurysms Groningen: s.n.

Off-the-Shelf Devices. Mark A Farber, MD FACS Director, Aortic Center Professor of Radiology and Surgery University of North Carolina

COMBINED TECHNIQUE CHIMNEY + FENESTRATED ENDOGRAFT FOR COMPLEX ANEURYSMS ERIC DUCASSE - MD PHD FEVBS CHU BORDEAUX

Update on the fenestrated Anaconda endograft for F/EVAR: worldwide experience from the global FACT registry

EndoVascular Aneurysm Sealing (EVAS) with Nellix

Endovascular Treatment of the Aorta with Fenestrated and Branched Grafts

Increased Flexibility of AneuRx Stent-Graft Reduces Need for Secondary Intervention Following Endovascular Aneurysm Repair

Mid-term results of 300+ patients treated by endovascular aortic sealing (EVAS)

Conflicts of Interest. When and Why Complex EVAR in Tx of juxta/suprarenal AAA? Summary. Infrarenal EVAR for short necks 2y postop

Nellix Endovascular System: Clinical Outcomes and Device Overview

Durability of The Endurant Stent-Graft through 5 Years

ChEVAR Vs. fevar for juxtarenal Aneurysm. E.Ducasse MD PhD FEVBS Unit of vascular surgery CHU bordeaux

An Overview of Post-EVAR Endoleaks: Imaging Findings and Management. Ravi Shergill BSc Sean A. Kennedy MD Mark O. Baerlocher MD FRCPC

When to use standard EVAR with EndoAnchors or CHEVAR in short-neck AAAs LINC ASIA 18

Access More Patients. Customize Each Seal.

Considerations for a Durable Repair

Lessons learned from Ch-EVAR for the treatment of. Miltos Matsagkas MD, PhD, FEBVS Professor of Vascular Surgery University of Thessaly

Outcomes of endovascular aortic aneurysm repair in patients with hostile neck anatomy

Is EVAS a proper choice in women?

Aortic Neck Issues Associated Clinical Sequelae/Implications for Graft Choice

Young-Guk Ko, M.D. Severance Cardiovascular Hospital, Yonsei University Health System,

Chungbuk Regional Cardiovascular Center, Division of Cardiology, Departments of Internal Medicine, Chungbuk National University Hospital Sangmin Kim

Anatomical challenges in EVAR

RadRx Your Prescription for Accurate Coding & Reimbursement Copyright All Rights Reserved.

Endovascular Repair o Abdominal. Aortic Aneurysms. Cesar E. Mendoza, M.D. Jackson Memorial Hospital Miami, Florida

Disclosures. EVAR follow-up: actual recommendation. EVAR follow-up: critical issues

ENCORE, a Study to Investigate the Durability of Polymer EVAR with Ovation A Contemporary Review of 1296 Patients

Endoleaks after F-BEVAR How to Assess & Treat? Gustavo S. Oderich, MD Mayo Clinic Rochester, MN

Residual Dissection and False Lumen Aneurysm After TEVAR

Clinical trial and real-world outcomes of an endovascular iliac aneurysm repair with the GORE Iliac Branch Endoprosthesis (IBE)

Current Status of EVAR for Infrarenal AAA. 31 st Annual Florida Vascular Society. PENN Surgery

Long-term results of Talent endografts for endovascular abdominal aortic aneurysm repair

Dr Peter Bungay Derbyshire Vascular Services Royal Derby Hospital Derby UK

Treatment options for endoleaks: stents, embolizations and conversions

SANWICH TECHNIQUE TO REDUCE COMPLICATIONS WHEN TREATING BILATERAL INTERNAL ILIAC ARTERY

EVAS using Nellix in my practice Where are we today?

THE ENDURANT STENT GRAFT IN HOSTILE ANEURYSM NECK ANATOMY

Bifurcated system Proximal suprarenal stent Modular (aortic main body and two iliac legs) Full thickness woven polyester graft material Fully

Optimizing Accuracy of Aortic Stent Grafts in Short Necks

Endovascular aneurysm repair alters renal artery movement: a preliminary evaluation using dynamic CTA.

Degeneration of the Neck Post Implementation - a New Era of AAA Stent

Early report from an investigator-initiated investigational device exemption clinical trial on physician-modified endovascular grafts

The Distal Seal Zone in AAA Repair A facet of EVAR that is not to be overlooked.

Case Report A Case of Successful Coil Embolization for a Late-Onset Type Ia Endoleak after Endovascular Aneurysm Repair with the Chimney Technique

TriVascular Ovation Prime Abdominal Stent Graft System

Endovascular Aneurysm Repair Alters Renal Artery Movement: A Preliminary Evaluation Using Dynamic CTA

Ovation. Sean Lyden, MD Department Chair, Vascular Surgery Cleveland Clinic

How to select FEVAR versus EVAR + endoanchors in short-necked AAAs

Outcomes of endovascular repair of isolated iliac artery aneurysms. A. Stella

As it currently stands, the mortality rate of

Citation for published version (APA): Dijkstra, M. L. (2018). Advances in complex endovascular aortic surgery. [Groningen]: University of Groningen.

Treatment of Thoracoabdominal Aneurysms Is there a need for custom-made devices?

My personal experience with INCRAFT in standard and challenging cases

The Management and Treatment of Ruptured Abdominal Aortic Aneurysm (RAAA)

A New EVAR Device for Infrarenal AAAs

Accessi Iliaci Ostili

Reinterventions After Fenestrated and Branched Endovascular Aortic Aneurysm Repair

Associate Professor Walter W. Buckley Endowed Chair in Research Cleveland Clinic Lerner College of Medicine-CWRU. Houston Aortic Symposium 2017

What is the benefit. of MEP s in BEVAR for TAAA. in preventing paraplegia?

J.M. Verhagen 1 MD, PhD.

LOWERING THE PROFILE RAISING THE BAR

University of Groningen. Covered stents in aortoiliac occlusive disease Grimme, Frederike. DOI: /j.ejvs /j.jvir

Right Choice for Right Angles

Internal iliac artery aneurysms: When to intervene and outcomes of EVAR

Tips and techniques for optimal stent graft placement in angulated aneurysm necks

11/20/2014. Disclosures. Kissing Balloons and Stents. Treatment of Aortoiliac Occlusive Disease. Data on Patency of Kissing Stents.

Ancillary Components with Z-Trak Introduction System

Anatomical applicability of current off-the-shelf branched endografts in thoracoabdominal aortic aneurysms managed by open surgery.

Analysis of Type IIIb Endoleaks Encountered with Endologix Endografts

Anatomy-Driven Endograft Selection for Abdominal Aortic Aneurysm Repair S. Jay Mathews, MD, MS, FACC

How effective is preservation when viewed through a clinical and economic lens?

Endovascular Aneurysm Sealing System for Treating Abdominal Aortic Aneurysms: Early Outcomes from a Single Center

Intravascular Ultrasound in the Treatment of Complex Aortic Pathologies. Naixin Kang, M.D. Vascular Surgery Fellow April 26 th, 2018

Preliminary Data from the Gore EXCLUDER Thoracoabdominal Branch Endoprosthesis Early Feasibility Study

FLEXIBLE, BALOON EXPANDABLE

Results of Endovascular Abdominal Aortic Aneurysm Repair with the Zenith stent-graft

From 1996 to 1999, a total of 1,193 patients with

No Neck Is Needed! Treat the Aneurysm Instead! Andrew Holden, MD Associate Professor of Radiology Auckland City Hospital

Mid-term results from ANCHOR: How does this data influence the treatment algorithm for hostile EVAR anatomies

Obesity, Scaring, Access in EVAR. Kiskinis D, Melas N, Ktenidis K. 1 st Department of Surgery Aristotle University of Thessaloniki, Greece

Talent Abdominal Stent Graft

Jean M Panneton, MD Professor of Surgery Program Director Vascular Surgery Chief EVMS. Arch Pathology: The Endovascular Era is here

Abdominal Aortic Aneurysms. A Surgeons Perspective Dr. Derek D. Muehrcke

Hostile Proximal Neck: A New Conformable EVAR Device

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

Ventana Fenestrated Stent-Graft System for Endovascular Repair of Juxtarenal Aortic Aneurysms

Abdominal and thoracic aneurysm repair

CHALLENGING ILIAC ACCESSES AND THROMBOSIS PREVENTION

Improving Endograft Durability with EndoAnchors

Transcription:

University of Groningen Advances in complex endovascular aortic surgery Dijkstra, Martijn Leander IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below. Document Version Publisher's PDF, also known as Version of record Publication date: 2018 Link to publication in University of Groningen/UMCG research database Citation for published version (APA): Dijkstra, M. L. (2018). Advances in complex endovascular aortic surgery [Groningen]: University of Groningen Copyright Other than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons). Take-down policy If you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from the University of Groningen/UMCG research database (Pure): http://www.rug.nl/research/portal. For technical reasons the number of authors shown on this cover page is limited to 10 maximum. Download date: 22-01-2019

chapter 4 Midterm results of the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair L.L. BLANKENSTEIJN, 1 M.L. DIJKSTRA, 1 I.F. TIELLIU, 1 M.M. REIJNEN, 2 AND C.J. ZEEBREGTS, ON BEHALF OF THE DUTCH FENESTRATED ANACONDA RESEARCH GROUP.* 1 Division of Vascular Surgery, Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. 2 Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands. * A list of members of the Dutch Fenestrated Anaconda Research Group is listed in the Appendix. J VASC SURG. 2017 FEB;65(2):303-310.

Chapter 4 abstract Objective: The fenestrated Anaconda endograft (Vascutek, Renfrewshire, Scotland) was introduced in 2010 and showed promising short-term results with high technical success and low morbidity rates. The aim of this study was to present the midterm results, with a minimum of 12 months follow-up, for all patients treated with the fenestrated Anaconda endograft in The Netherlands. Methods: Patients treated with the fenestrated Anaconda endograft between May 2011 and February 2015 were included. Follow-up consisted of computed tomography angiography at 1 month and 1 year, and duplex ultrasound yearly thereafter with additional computed tomography angiography if indicated using a standard protocol. Results: A total of 60 patients were included; 48 patients (80.0%) were treated for juxtarenal aneurysms, and 12 (20.0%) were short-neck infrarenal aneurysms. Mean aneurysm size was 64 ± 9 mm. A total of 140 fenestrations were incorporated. Median follow-up was 16.4 months (interquartile range 11.9-27.4). The 30-day mortality was 3.4 % (n = 2). Kaplan-Meier estimates for 1-year, 2-year, and 3-year survival were 91.4 %, 89.5 %, and 86.3 %, respectively, without aneurysm-related mortality during follow-up. Main body primary and secondary endograft patencies were 98.3 % and 100 %, respectively. Target vessel primary and secondary patencies were 95.0 % and 98.6 %, respectively. Early type IA endoleaks occurred in seven patients (11.7%) and spontaneously resolved in all patients. At 1-year follow-up 4 (6.7%) type II endoleaks persisted. One patient experienced aneurysm rupture because of a late type III endoleak attributable to a dislodged renal stent and subsequently underwent successful conversion to open surgery. Conclusions: The fenestrated Anaconda is a viable treatment option for complex abdominal aortic aneurysms. Acceptable mortality and morbidity and low reintervention rates contribute to good midterm results. Occurrence of early type I endoleak was relatively common, but these resolved spontaneously in all patients. 56

Fenestrated Anaconda - Midterm results introduction Endovascular aneurysm repair (EVAR) has evolved rapidly since its introduction in 1991, and the majority of patients with an abdominal aortic aneurysm (AAA) are now treated by endovascular means. 1 However, up to 30 % of all patients with AAAs are not suitable for treatment using standard infrarenal endografts because of complex anatomy, including short infrarenal neck length (< 15 mm), severe angulation (> 60), or aneurysms that involve important (visceral) side branches. 2 To overcome these technical difficulties, the concept of fenestrated EVAR (FEVAR) was developed and successfully introduced in 1999. 3 Subsequent advances in FEVAR treatment and techniques have resulted in successful treatment of not only short-neck infrarenal and juxtarenal aneurysms, but also thoracoabdominal aneurysms with increasing anatomic complexity. 4 7 4 Most of the current knowledge is based on the Zenith custom-made fenestrated endograft (Cook Medical Australia, Brisbane, Queensland, Australia). The fenestrated Anaconda endograft (Vascutek, Renfrewshire, Scotland) was introduced in 2010, and initial reports on use of the fenestrated Anaconda were published in 2011 and 2012 by Bungay et al. 8,9 The Dutch Fenestrated Anaconda Research Group subsequently published the short-term results of the first 25 patients treated in The Netherlands. 10 The possible advantages of the fenestrated Anaconda were explored, and the data showed promising short-term results with high technical success rates and low morbidity. However, durability has yet to be proven because there are no mid- and longer-term data available regarding this new fenestrated device. A larger number of patients have now been treated using the fenestrated Anaconda in The Netherlands. The aim of this study was to present an update of the previous cohort and subsequent patients treated, and to present the midterm results of this larger cohort. MeThods design of the study Patients who underwent exclusion of an aneurysm with a fenestrated Anaconda endograft in The Netherlands between May 2011 and February 2015 were included. The current population in The Netherlands is approximately 17 million people; 49.6 % is male, and 15.6 % is aged 65 and over. Data were collected in the respective hospitals and retrospectively analyzed. All patients were assessed preoperatively using multislice detector computed tomography angiography (CTA). Patients were treated in accordance with current international treatment 57

Chapter 4 guidelines. 11,12 Indications for FEVAR included unsuitable anatomy for conventional EVAR (short-neck length [< 15 mm], hostile proximal sealing zone, or important aortic side branches involved in the aneurysm) and was ultimately decided by the treating physician. The procedures were performed in either a hybrid suite equipped for both interventional radiology and open surgical procedures or a surgical theater using a recent generation mobile C-arm. Follow up consisted of CTA at 1 month and 1 year, and duplex ultrasound yearly thereafter with additional CTA if indicated using a standard protocol. The standard CTA protocol included non-contrast, early (arterial), and delayed contrast series. In case of a suspected endoleak on duplex ultrasound during follow-up, a subsequent CTA was performed. All patients who were included had at least 12 months of follow-up except for those who died before reaching the 1-year follow-up. The fenestrated anaconda endograft A detailed description of the fenestrated Anaconda and possible advantages compared to other fenestrated devices have been published previously. 8,10 The fenestrated Anaconda is a repositionable customized device for individual patient use based on the Anaconda AAA endograft system. 13 There are a number of theoretical advantages compared with other devices, including the following. (1) It is repositionable after full deployment, allowing for accurate deployment and repositioning of the endograft body and its fenestrations. (2) Fenestrations are placed in the unsupported region maximizing the area available and potentially allowing for easier alignment and subsequent cannulation of target vessels. (3) The lack of columnar strength combined with a ringed distal design might also allow for treatment of more angulated and stenotic anatomy. A range of configurations is currently available allowing for the device from one fenestration up to five fenestrations, although a maximum of four fenestrations were used in this study. Also, the addition of an augmented valley (comparable to a scallop), and either a bifurcated or a tube design add further possibilities to enable treatment of AAAs with a varying range of complex anatomy. Stent implantation. The procedural details have been published previously. 10 In short, bilateral femoral access was obtained either percutaneously or by cutdown. All patients were heparinized perioperatively. After introduction and deployment of the fenestrated main body, the fenestrations and target vessels were cannulated and angiography performed to confirm the position. If not satisfactory, the main body would be collapsed and repositioned to achieve a more satisfactory position. Once in place, the target vessels were cannulated with balloon expandable covered stents using standard endovascular techniques. Finally, the endograft was completed by placing the limb extensions, and a completion angiogram was performed. In case of a type IA or III endoleak on the completion angiogram, 58

Fenestrated Anaconda - Midterm results repeat angioplasty was performed at the respective site of the endoleak if possible. Residual type IA endoleaks after repeat angioplasty were accepted. definitions Juxtarenal was defined as an aneurysm that abuts the renal arteries, but does not involve the renal arteries (no normal sized aorta between upper extent of aneurysm and renal arteries). 14 Short neck was defined as an aneurysm with a normal portion of the aorta between the upper extent of the aneurysm and lowest renal artery, and with a neck length < 15 mm. 4 Clinical success (midterm) was defined as successful deployment of the endovascular device at the intended location without type I or III endoleak, graft infection or thrombosis, aneurysm expansion (diameter > 5 mm), aneurysm rupture or conversion to open repair, graft migration, a failure of device integrity, or death as a result of aneurysm-related treatment. 14 Technical success was defined as successful introduction and deployment of the device in the absence of surgical conversion or mortality, type I or III endoleaks, or graft limb obstruction. statistics Continuous variables are described as mean and standard deviation or median and interquartile range in case of skewed data. To test for normality a Kolmogorov-Smirnov test was performed. Differences between continuous variables were tested using a paired Student t-test or Mann-Whitney U test in case of skewed data. Survival and intervention free survival analysis were conducted using Kaplan-Meier estimates. Two-sided P values of <.05 were considered significant. Statistical analysis was performed using SPSS statistics v 20.0 (IBM Corporation, Armonk, NY). results A total of 60 patients were treated in 13 sites located in The Netherlands. The mean age was 72 ± 7 years, and 52 of these patients were male (86.7%). Patients treated were mainly classified as American Society of Anesthesiologists III (60.0%) because of significant comorbidities. Full demographics are shown in 59

Chapter 4 Table 1. Demographics. Mean ± SD N (%) Age (in years) 72 (± 7) Sex Male 52 (86.7) Female 8 (13.3) ASA class 2 22 (36.7) 3 36 (60.0) 4 2 (3.3) Comorbidities Diabetes mellitus Yes 8 (13.3) Hypertension Yes 39 (65.0) Hypercholesterolemia Yes 34 (56.7) Smoking Yes 22 (36.7) Cardiac disease Yes 33 (55.0) Pulmonary disease Yes 16 (26.7) Renal disease Yes 17 (28.3) Abbreviations: ASA, American Society of Anesthesiologists; SD, standard deviation. Table 1. The median number of procedures per hospital was 4.5 (1 7). The majority of patients (n = 48; 80.0 %) were treated for juxtarenal aneurysms, while the remaining 12 (20.0%) were short-neck aneurysms. Mean proximal neck length was 6 ± 4 mm. Mean aneurysm diameter was 64 ± 9 mm. Two (3.3%) aortouniiliac devices were used; the remaining 58 (96.7%) were bifurcated devices. Data on the specific device configurations are summarized in Table 2. About one-half of the endografts had a two fenestration design (56.7%) incorporating the renal arteries. Mean operative time was 262 ± 96 minutes with a median contrast dose of 178 ml (range, 70 380 ml). The option to reposition the main device was used in 41 cases (68.3%). Upper access was used in 18 (30.0%) patients. Patients had a median total length of stay of 6 days (4 9). Perioperative complications occurred in 14 patients and included pneumonia (n = 3), surgical site infection (n = 1), delirium (n = 1), cerebral vascular accident (n = 1), decline in renal function (n = 4), anemia (n = 3), gastroenteritis (n = 1), and lower leg compartment syndrome (n = 1), with a total 30-day morbidity rate of 25.0 % (n = 15). 30-day mortality rate was 3.3 % (n = 2). Cause of death was postoperative bowel ischemia in one patient, which is described in detail previously 10 and unknown in the second patient. Median follow-up was 16.4 months (interquartile range, 11.9 27.4). There was no loss to follow-up. Postoperative (temporary) decrease in renal function was observed in 18 patients (30.0%). 60

Fenestrated Anaconda - Midterm results Table 2. Procedural details. Mean (± SD) or N (%) Type of aneurysm Juxtarenal 48 (80.0 Short neck 12 (20.0) Neck length (mm) 6 (4) Maximum AAA diameter (mm) 64 (9) Endograft type Bifurcated 58 (96.7) Aorto-uni-iliac 2 (3.3) Type of topstent Standard 21 (35.0) Augmented valley 39 (65.0) Main device diameter (mm) 25 2 (3.3) 28 13 (21.7) 30 13 (21.7) 32 16 (26.7) 34 16 (26.7) Oversize (%) 19.7 (3.4) Number of fenestrations 1 5 (8.3) 2 34 (56.7) 3 17 (28.3) 4 4 (6.7) Main device repositioned No 19 (31.7) Yes 41 (68.3) Upper acces No 42 (60.0) Yes 18 (30.0) Fluoroscopy time (min) 78 (40) Procedure time (min) 262 (96) Contrast dosage (ml) 178 (68) 4 Abbreviations: AAA, Abdominal aortic aneurysm; IQR, interquartile range; SD, standard deviation. 61

Chapter 4 Table 3. Follow up. Median (IQR) N (%) Follow up (months) 16.4 (11.9 27.4) egfr (ml/min) 57.5 (41.8 75.8) Mid-term clinical success 53 (88.3) Yes 53 (88.3) No 7 (11.7) Kinking No 60 (100.0) Yes 0 (0.0) Migration No 59 (98.3) Yes 1 (1.7) Graft infection No 60 (100.0) Yes 0 (0.0) Endoleak Type I 0 (0.0) Type II 4 (6.7) Type III 0 (0.0) Aneurysm size Increase 5 (8.3) Decrease 35 (58.3) Stable 14 (23.3) Unknown 6 (10.0) Re-intervention Yes 4 (6.7) No 50 (83.3) Abbreviations: egfr, Estimated glomerular filtration rate; IQR, interquartile range. Long-term renal dysfunction was found in four patients (6.7%), of which two patients had preexisting renal dysfunction. One patient (1.7%) required dialysis treatment. In the longer term, there was a minor but significant decline in estimated glomerular filtration rate (egfr in ml/min) from 60.0 (57.0 77.5) to 57.5 (41.8 75.8; P <.05) at the last follow-up visit. Follow-up details are shown in Table 3. Five patients died during follow-up. Cause of death was pneumosepsis (n = 1), congestive heart failure (n = 1), cardiac arrhythmia (n = 1), hemorrhagic cerebral vascular accident (n = 1), and unknown (n = 1). Kaplan-Meier survival estimates for 1-year, 2-year, and 3-year survival were 91.4 %, 89.5 %, and 86.3 %, re- 62

Fenestrated Anaconda - Midterm results 4 Time (months) 0 12 24 36 48 No at risk 60 48 36 24 12 Survival (%) 100.0 91.4 89.5 86.3 86.3 Std. Error 0.037 0.041 0.050 0.050 Figure 1. Kaplan meier survival analysis, showing survival of patients after FEVAR using the fenestrated Anaconda. spectively. Kaplan-Meier patient survival analysis is shown in Figure 1. There were no aneurysm-related deaths after 30-days follow-up. One patient suffered bowel ischemia perioperatively as previously described. The other patient died 1 month postoperatively after being discharged on the fifth postoperative day and before having the 1-month follow-up CTA. Cause of death remains unknown. The patient did have signs of a type IA endoleak at completion angiogram, and, therefore, we cannot exclude the possibility of aneurysm-related death. One patient experienced a rupture 1 year postoperatively because of a type III endoleak. The patient experienced the rupture while traveling abroad and was admitted to a local hospital. CTA was performed that showed dislodgement of a renal fenestration stent, and the patient underwent successful emergent open surgery and reconstruction with a tube graft. There were two graft migrations reported. In the first patient, this occurred 1 month postoperatively and resulted in bilateral occlusion of the renal arteries, after which the patient required dialysis treatment. In the second patient, graft migration occurred 3 months postoperatively with subsequent dislocation of the stents to the right renal artery (RRA), left renal artery (LRA), superior mesenteric artery, and celiac trunk. The 63

Chapter 4 patient underwent open revascularization of both renal arteries and the celiac trunk. There was one left iliac limb occlusion at 17 months, which was successfully treated by surgical thrombectomy and subsequent endarterectomy of an atherosclerotic left common femoral artery. Therefore, primary and secondary endograft patency rates were 98.3 % and 100 %, respectively. There were no graft infections. No kinking of the main body or limbs occurred. A total of 140 fenestrations were incorporated to accommodate the target vessels; 136 fenestrations were successfully cannulated and stented (97.1%). During follow-up four target vessels occluded in three patients (RRA, n = 2; LRA, n = 2). For the target vessels, primary patency was, therefore, 95.0 %. Two of the occluded target vessels were successfully treated by endovascular means. Therefore, secondary target vessel patency was 98.6 %. In total, 27 (45.0%) patients had an endoleak on either the perioperative completion angiogram or on the discharge CTA, including type IA (n = 7, 11.7 %), type II (n = 18, 30.0 %), and type III endoleaks (n = 2, 3.3 %). Technical success Time (months) 0 12 24 36 48 No at risk 60 48 36 24 12 Intervention free survival (%) 100 96.5 92.1 88.5 88.5 Std. Error 0.024 0.038 0.051 0.051 Figure 2. Kaplan meier intervention free survival analysis, showing intervention free survival of patients after FEVAR using the fenestrated Anaconda. 64

Fenestrated Anaconda - Midterm results was, therefore, 85.0 %. The majority of the endoleaks resolved spontaneously. At 1-year follow-up, only four (6.7%) type II endoleaks persisted. As mentioned above, one late type III endoleak led to subsequent aneurysm rupture and conversion to open surgery. Intervention free survival analysis using Kaplan-Meier estimates is shown in Figure 2. There were no significant differences in demographics, endograft configuration, or periprocedural variables between patients with an endoleak compared with those without signs of endoleaks. Aneurysm size decreased in 36 (60.0%) patients, remained stable in 15 (25.0%), and increased in five (8.3%) patients. In the subgroup of patients that showed an increase in aneurysm size, one early type IA endoleak and two type II endoleaks were observed. This resulted in an overall midterm clinical success rate of 88.3 %. 4 discussion The presented midterm data on the fenestrated Anaconda endograft indicate the device to be a viable alternative for the treatment of patients with complex AAAs. The midterm clinical success and patency rates are high with a low reintervention rate and no proven aneurysm-related mortality during follow-up. A 30-day mortality rate of 3.4 % (n = 2) was achieved in this cohort, which is comparable to midterm results with the Zenith custom-made fenestrated endograft (Cook Medical, Australia). 5,15,16 The option to reposition the graft after initial deployment was frequently used (68.3%). This feature can be helpful in complex anatomy where precise positioning is paramount. On the other hand, caution was advised in using this feature because of the possible induction of thromboembolic events, as was the case in the patient who developed bowel ischemia (n = 1). In this larger cohort, fortunately, no additional perioperative thromboembolic complications were observed. Procedure time and contrast dosage compare with other devices currently used. 4,17,18 Compared with earlier reports, there is a high incidence of endoleaks, including type IA and type II endoleaks. 8,10 This also explains the low technical success rate of 85.0 %. As described in our previous report, it was hypothesized that early type IA endoleaks seem to disappear spontaneously, possibly because of the specific endograft top stent design. This is believed to be due to increased embedding of the proximal stents with the vessel wall in time, providing improved apposition and sealing after initial device deployment. The increased embedding occurs as the stent material temperature increases to body temperature following deployment, causing the stent s radial force to increase, while the vessel conforms locally to the shape of the stent. In the longer term, it is known that the stents continue to embed over the months following implantation. This 65

Chapter 4 hypothesis holds true in the current series, where 10 early type I endoleaks were observed. Obviously, in case of a type IA endoleak attempts were made to correct this intraoperatively either by repositioning the endograft or by re-ballooning the proximal seal. The latter is only possible in a four-fenestration design where there is enough room above the fenestrations. Obviously, it is not advocated to readily accept type IA endoleaks. However, a type IA endoleak that persisted despite attempts to correct this was accepted, and patients underwent standard followup including 1-month CTA and subsequent re-intervention if appropriate. In this cohort, no type IA endoleak persisted and no re-interventions were necessary. In this cohort one rupture did occur because of a type III endoleak, for which the patient was successfully converted to open surgery. The patient was traveling abroad at the time of the event and was, therefore, treated in a local hospital. The correspondence notes dislodgement of a renal fenestration and subsequent type III endoleak and rupture. This patient had a shortneck infrarenal aneurysm (proximal neck length of 6 mm) and was treated with a two-fenestration endograft (RRA and LRA). The procedure was uneventful, and the follow-up imaging showed a type II endoleak but no other signs of complications up to the event. Noteworthy, there was no indication of migration. The proximal oversize in this case was 16.7 %. In this specific case, there was, however, an increase of the aneurysm sac diameter of 2 mm at the 6-month follow-up CTA, which should prompt caution but not necessarily immediate re-intervention for the known type II endoleak. The treating physician made numerous efforts to obtain the imaging performed at the time of the event, ultimately without success and unfortunately the exact cause for stent dislodgement remains unclear. Analysis of the data did not show any significant differences in demographics, endograft configuration, or perioperative variables between the endoleak and no endoleak groups, which is in part due to the still relatively small numbers. The consensus that type II endoleaks can be safely managed conservatively seems to hold true in the current series, especially if there is a stable or decreasing aneurysm diameter. Type III endoleaks also spontaneously resolved. Re-evaluation of these type III endoleaks showed they were actually type II endoleaks that had been misinterpreted at the time of original analysis. All of these had been diagnosed on the perioperative completion angiography, and the 1-month follow-up CTA, however, did not show any type III endoleaks. In total, five (8.3%) patients underwent either an endovascular or an open re-intervention during follow-up as discussed in the Results section, which is relatively low compared with other reports of FEVAR. 5,15,16 66

Fenestrated Anaconda - Midterm results Four patients showed a decline in renal function postoperatively with patent side branches, and during follow-up, there was a minor, but significant decrease in renal function (egfr in ml/min) preoperatively 60.0 (57.0 77.5) to 57.5 (41.8 75.8; P <.05) at final follow-up visit. In a subanalysis excluding those patients with known renal disease, there was also a significant decline in renal function (egfr in ml/min) during follow-up of 70.0 (60.0 83.0) to 60.0 (50.8 84.5; P <.05). In one patient, the main device migrated causing dislocation and subsequent occlusion of both renal arteries. In this case, a short-neck infrarenal aneurysm was treated (proximal neck length 5 mm) using a three-fenestration device (RRA, LRA, and an ancillary LRA). No cause for the migration was identified; the procedure was uneventful without signs of endoleak on completion angiography, and the device was adequately oversized by 21.4 %. In spite of a re-intervention aimed to restore renal artery perfusion, only the ancillary LRA was successfully recanalized, and the patient became dialysis dependent. This in part explains the drop in egfr. Second, contrast induced nephropathy might also have contributed. Previous studies have shown a decline in renal function to be a significant risk after FEVAR, as is the case in this cohort. 19 Given patients with renal complications after FEVAR are at risk for dialysis or even death, maximal efforts should be undertaken to reduce contrast dosage. Also, advances in techniques, including advanced imaging and perioperative guidance, 20 experience, and perioperative care are important to minimize these effects. 4 The current results are comparable to results with the most commonly used fenestrated endograft (Cook Zenith custom-made). Midterm results using the Cook device showed similar all-cause mortality (13.0%) and 30-day mortality (2.6%) rates, as well as similar contrast dosages and procedure times. The reported visceral primary branch patency was 92.0 % at 46 months. 15 All postoperative occlusions in this study by Muhs et al 15 occurred in unstented fenestrations or scallops. It has now become common practice to stent all fenestrations and most scallops as well. 21 This may explain the higher primary and secondary fenestration patency in the present study (95.0% and 98.6, respectively). Another study by Oderich et al 22 reported a slightly lower 30-day mortality of 1.5 % in 67 patients using the Zenith fenestrated AAA endovascular graft. In this cohort, there were no early type IA endoleaks and one late type IA endoleak, which was successfully treated by coil embolization, and 16 patients had a type II endoleak (29%). In the current cohort, there was a higher incidence of endoleaks regardless of the type. However, the difference is largely explained by the early type IA endoleaks (11.7%) with a comparable incidence of type II endoleak (30.0%). The present study has several limitations. The data were prospectively collected in the respective hospitals, but retrospectively analyzed. As with any new device, 67

Chapter 4 a learning curve is to be expected, although all treating centers and physicians had extensive experience with complex endovascular procedures. With a total of 13 centers in The Netherlands participating, the median number of procedures for each center is limited. However, a subanalysis of the centers with the lowest number of procedures did not show a significant increase in serious adverse events or mortality. The cause of death remained unknown in three patients. These deaths are likely not aneurysm related, however, no definitive statements can be made to this regard. Specifically, in the patient who died before having the 1-month follow-up CTA, assuming the worst possible outcome, he would have had a rupture because of the small type IA endoleak on completion angiogram. This, however, is considered unlikely, given the experiences with other type IA endoleaks as presented. Unfortunately no postmortem examination was performed. Given the still relatively small sample size, no predisposing factors for adverse outcomes (eg, which type IA endoleaks require intervention) could be identified. Further studies are needed to identify those patients at risk and clarify indications for reintervention. conclusion The fenestrated Anaconda is a viable treatment option for complex AAAs. Acceptable mortality and morbidity and low re-intervention rates contributed to good midterm results. Occurrence of early type I endoleak was relatively common, but these resolved spontaneously in all patients. 68

Fenestrated Anaconda - Midterm results references 1. Dua A, Kuy S, Lee CJ, Upchurch GR Jr, Desai SS. Epidemiology of aortic aneurysm repair in the United States from 2000 to 2010. J Vasc Surg 2014; 59: 1512-7. 2. Buck DB, van Herwaarden JA, Schermerhorn ML, Moll FL. Endovascular treatment of abdominal aortic aneurysms. Nat Rev Cardiol 2014; 11: 112-23. 3. Faruqi RM, Chuter TA, Reilly LM, Sawhney R, Wall S, Canto C, et al. Endovascular repair of abdominal aortic aneurysm using a pararenal fenestrated stent graft. J Endovasc Surg 1999; 6: 354-8. 4. Verhoeven EL, Prins TR, Tielliu IF, van den Dungen JJ, Zeebregts CJ, Hulsebos RG, et al. Treatment of short-necked infrarenal aortic aneurysms with fenestrated stent grafts: short-term results. Eur J Vasc Endovasc Surg 2004; 27: 477-83. 5. Greenberg RK, Sternbergh WC III, Makaroun M, Ohki T, Chuter T, Bharadwaj P, et al. Intermediate results of a United States multicenter trial of fenestrated endograft repair for juxtarenal abdominal aortic aneurysms. J Vasc Surg 2009; 50: 730-7.e1. 4 6. Verhoeven EL, Vourliotakis G, Bos WT, Tielliu IF, Zeebregts CJ, Prins TR, et al. Fenestrated stent grafting for short-necked and juxtarenal abdominal aortic aneurysm: an 8-year single centre experience. Eur J Vasc Endovasc Surg 2010; 39: 529-36. 7. Mastracci TM, Greenberg RK, Eagleton MJ, Hernandez AV. Durability of branches in branched and fenestrated endografts. J Vasc Surg 2013; 57: 926-33. 8. Bungay PM, Burfitt N, Sritharan K, Muir L, Khan SL, De Nunzio MC, et al. Initial experience with a new fenestrated stent graft. J Vasc Surg 2011; 54: 1832-8. 9. Bungay P. The use of the Anaconda stent graft for abdominal aortic aneurysms. J Cardiovasc Surg (Torino) 2012; 53: 571-7. 10. Dijkstra ML, Tielliu IF, Meerwaldt R, Pierie M, van Brussel J, Schurink GW, et al. Dutch experience with the fenestrated Anaconda endograft for short-neck infrarenal and juxtarenal abdominal aortic aneurysm repair. J Vasc Surg 2014; 60: 301-7. 11. Chaikof EL, Brewster DC, Dalman RL, Makaroun MS, Illig KA, Sicard GA, et al. SVS practice guidelines for the care of patients with an abdominal aortic aneurysm: executive summary. J Vasc Surg 2009; 50: 880-96. 12. Moll FL, Powell JT, Fraedrich G, Verzini F, Haulon S,Waltham M, et al. Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. Eur J Vasc Endovasc Surg 2011; 41(Suppl 1): S1-58. 13. Rodel SG, Geelkerken RH, Prescott RJ, Florek HJ, Kasprzak P, Brunkwall J. The Anaconda AAA stent graft system: 2-year clinical and technical results of a multicentre clinical evaluation. Eur J Vasc Endovasc Surg 2009; 38: 732-40. 14. Chaikof EL, Blankensteijn JD, Harris PL, White GH, Zarins CK, Bernhard VM, et al. Reporting standards for endovascular aortic aneurysm repair. J Vasc Surg 2002; 35: 1048-60. 69

Chapter 4 15. Muhs BE, Verhoeven EL, Zeebregts CJ, Tielliu IF, Prins TR, Verhagen HJ, et al. Mid-term results of endovascular aneurysm repair with branched and fenestrated endografts. J Vasc Surg 2006; 44: 9-15. 16. O Neill S, Greenberg RK, Haddad F, Resch T, Sereika J, Katz E. A prospective analysis of fenestrated endovascular grafting: intermediate-term outcomes. Eur J Vasc Endovasc Surg 2006; 32: 115-23. 17. Greenberg RK, Haulon S, Lyden SP, Srivastava SD, Turc A, Eagleton MJ, et al. Endovascular management of juxtarenal aneurysms with fenestrated endovascular grafting. J Vasc Surg 2004; 39: 279-87. 18. Holden A, Mertens R, Hill A, Marine L, Clair DG. Initial experience with the Ventana fenestrated system for endovascular repair of juxtarenal and pararenal aortic aneurysms. J Vasc Surg 2013; 57: 1235-45. 19. Haddad F, Greenberg RK, Walker E, Nally J, O Neill S, Kolin G, et al. Fenestrated endovascular grafting: the renal side of the story. J Vasc Surg 2005; 41: 181-90. 20. Dijkstra ML, Eagleton MJ, Greenberg RK, Mastracci T, Hernandez A. Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endografting. J Vasc Surg 2011; 53: 583-90. 21. Grimme FA, Zeebregts CJ, Verhoeven EL, Bekkema F, Reijnen MM, Tielliu IF. Visceral stent patency in fenestrated stent grafting for abdominal aortic aneurysm repair. J Vasc Surg 2014; 59: 298-306. 22. Oderich GS, Greenberg RK, Farber M, Lyden S, Sanchez L, Fairman R, et al. Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms. J Vasc Surg 2014; 60: 1420-8. e1-5. 70

Fenestrated Anaconda - Midterm results appendix Dutch Fenestrated Anaconda Research Group Department of Surgery (Division of Vascular Surgery), University Medical Center Groningen, Groningen; Prof. dr. C.J. Zeebregts*, dr. I.F.J. Tielliu. Department of Surgery (Division of Vascular Surgery), Medical Spectrum Twente, Enschede; dr. R.H. Geelkerken*, dr. R. Meerwaldt. Department of Surgery (Division of Vascular Surgery), Isala Clinics, Zwolle; dr. M.E.N. Pierie. Department of Surgery (Division of Vascular Surgery), Sint Franciscus Gasthuis, Rotterdam; dr. J.P. van Brussel. Department of Surgery (Division of Vascular Surgery), Jeroen Bosch Ziekenhuis, s-hertogenbosch; drs. R.F.F. van den Haak. 4 Department of Surgery, Maastricht University Medical Center, Maastricht; Prof. dr. G.W. Schurink. Department of Surgery (Division of Vascular Surgery), University Medical Center Utrecht, Utrecht; dr. J.A. van Herwaarden. Department of Surgery (Division of Vascular Surgery), Rijnstate Hospital, Arnhem; dr. J.W. Lardenoije*, dr. M.M.P.J. Reijnen. Department of Surgery (Division of Vascular Surgery), Medical Centre Leeuwarden, Leeuwarden; dr. A.K. Jahrome. Department of Surgery (Division of Vascular Surgery), Academic Medical Centre, Amsterdam; Prof. dr. R. Balm. Department of Surgery (Division of Vascular Surgery), Gelre Hospital, Apeldoorn; dr. P.L. Klemm, dr. M.E. Witte. Department of Surgery (Division of Vascular Surgery), t Groene Hart Hospital, Gouda; dr. E.J. Waasdorp, dr. P.M. Schlejen. Department of Surgery (Division of Vascular Surgery), University Medical Centre Erasmus, Rotterdam; dr. M.J. van Rijn, Prof. dr. H.J.M. Verhagen. * Consultants for Vascutek 71