APPLICATIONS Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns

Similar documents
Core-Shell Technology for Proteins and Peptides

APPLICATIONS TN Dramatically Improve Existing 5 µm and 3 µm Fully Porous Methods with Kinetex 5 µm Core-shell Technology.

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN µm Core-Shell Particle. (continued on page 2) Page 1 of 8. For additional technical notes, visit

For Far. Greater. UHPLC Column Performance You Must Have Kinetex Core-Shell UHPLC Columns.

A Fast, Accurate, and Sensitive Quantitiation of Vitamin C in Plasma by Impact Protein Precipitation and Kinetex 5 µm Core-Shell XB-C18 HPLC Columns

Aeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE

Columns The FIRST and ONLY sub-2 µm core-shell columns on the market

Finally, a Solid Phase Extraction product for Drugs of Abuse

APPLICATIONS TN Materials and Methods

APPLICATIONS TN A Comparison of Various Kinetex C18 Phases USP: L1

Protect Your Mass Spec

APPLICATIONS TN Analytical Method

APPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD

Enantiomeric and Diastereoisomeric Resolutions of Chiral Triazole Fungicides using Lux Polysaccharide-Based Chiral Stationary Phases

Labs Across the World Are Advancing Their Protein Precipitation

APPLICATIONS TN Rapid Analysis of Hop Acids in Beer using Strata -X Solid Phase Extraction and Kinetex 2.6 µm Core-Shell Technology Column

Figure 1. Core-Shell Particle Technology

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Preparative Chromatography Meets UHPLC

Yes You Can! New! Amazing EVO C18. Core-Shell Technology

NEW. Kinetex. Biphenyl TMS TMS TMS TMS. Selectivity that a C18 just can t give you!

Phospholipid Removal Solutions

SIMPLIFIED CHIRAL SEPARATIONS. Lux Cellulose-1. Guaranteed Alternative. to CHIRALCEL OD-H. Exceptional Quality Sensibly Priced

Rapid Analysis of Synthetic Cannabinoids and their Metabolites in Urine using Solid Phase Extraction and LC/MS/MS. JWH018-4-Hydroxypentyl metabolite

Core-Shell Technology. 11 HPLC Myths. Uncovered. & Why You Must Have Kinetex Core-Shell HPLC Columns

APPLICATIONS TN A Sensitive Extraction Method for Nicotine and Metabolites from Urine using Simplified Liquid Extraction (SLE)

Exceed your Purification Goals. Guaranteed. Phenomenex l WEB:

PAIN PANEL. Research and Solutions

APPLICATION TN Materials and Methods Reagents and Chemicals

Comparison of a UPLC Method across Multiple UHPLC Systems

Awesome! Unconventionally. Kinetex EVO C18 HPLC/UHPLC Core-Shell Columns 2.6. Core-Shell Technology

Keep It Clean. Solid Phase Extraction Solutions for Drugs of Abuse Analysis. Neutral Drugs of Abuse Basic Drugs of Abuse

The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Extended Application Note

METHAMPHETAMINE & AMPHETAMINE

COMBO ULTIMATE HPLC/UHPLC. Kinetex + Luna Omega NEW. Gain Incredible Performance, Versatile Selectivities and Upgrade Throughput

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

LC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined

Keep it Clean with Strata -X

Converting a CHP Method for Insulin to Agilent Poroshell 120 Columns

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs. Table 1. List of pain panel drugs

APPLICATIONS TN Rapid, High Resolution Analysis of Aflatoxin Extracts from Peanut Butter Using Kinetex Core-Shell Technology and Strata SPE

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

Phenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases

NEW Kinetex F5. HPLC/UHPLC Core-Shell Columns

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Impurity Profiling of Carbamazepine by HPLC/UV

Confidence. A New Standard of. Calibration, Surrogate, & Internal Standards for Environmental Analysis

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

PAIN PANEL. Application Guide. Screen 41 compounds in under 4 minutes

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

Supported Liquid Extraction (SLE) For Food Applications

Hyper-fast & Super-rugged

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

TN-0116 Scott Krepich

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

Core-Shell / Solid core Particles: A Practical Substitute to Sub-2 Micron Particles: An overview

New HPLC Column Options for UHPLC

A New Era in SFC Column Technology

Fused-Core Particles:

Strata-X- NEW! Drug B. Drug B Plus for In-Well Hydrolysis. Simplify Your Solid Phase Extraction.

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

New Luna Omega. Columns. The Final Word in Fully Porous UHPLC

APPLICATION TN Rapid Analysis of a 48 Drug Research Panel in Less Than 4 Minutes Using Kinetex Biphenyl Core-Shell Technology HPLC/UHPLC Columns

Core-Shell Technology. Kinetex. Columns. The chosen core-shell brand to drive UHPLC performance to the next level. Core-Shell Technology

Am I getting the very best value from my UHPLC analyses?

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Vitamin Testing APPLICATIONS GUIDE

Ultimate Core Performance to Maximize Your Investment

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

Insulin SEC analysis. Insulin Samples:

Selectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants

The Raptor HILIC-Si Column

GlycanPac AXR-1 Columns

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

Separations. Sweet Sugar. Are in Your Future. New. Luna Omega SUGAR LC Column OMEGA

Application Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

Thermo Scientific. GlycanPac AXR-1. Column Product Manual. P/N: April, Part of Thermo Fisher Scientific

High Resolution Glycopeptide Mapping of EPO Using an Agilent AdvanceBio Peptide Mapping Column

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

A Novel HILIC Column for High Speed N-linked Glycan Analysis

InertSustainBio C18. Rapid Separations of Proteins and Peptides

ZIDOVUDINE, LAMIVUDINE AND ABACAVIR TABLETS Draft proposal for The International Pharmacopoeia (September 2006)

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system

ACE C18-AR Use the Power!

2D-LC as an Automated Desalting Tool for MSD Analysis

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

Transcription:

Improving Intact Biogeneric Protein Separations with Aeris WIDEPORE Core-Shell Columns Michael McGinley, Deborah Jarrett, and Jeff Layne Phenomenex, Inc., 411 Madrid Avenue, Torrance, CA 91 USA Aeris WIDEPORE is a recently introduced core-shell HPLC UHPLC column specifically designed to provide improved resolution of intact proteins larger than 1 kilodaltons (KDa) in molecular weight. The improved resolution of proteins is accomplished by the use of a new core-shell particle morphology which imizes protein band-spreading that occurs during diffusion in and out of the coreshell particle. The result is narrower peaks and better resolution of closely eluting proteins. This improved resolution is especially useful for refolding, impurity, and post-translational modification assays on intact biogeneric proteins where very slight differences between intact and modified proteins elute closely on reversed phase columns. Several examples are shown demonstrating the utility of Aeris WIDEPORE core-shell columns for such applications. Introduction Since their debut over two years ago, Kinetex core-shell columns have introduced a new paradigm in ultra-high performance by decoupling column efficiency from high backpressures. This has resulted in small molecule applications with reduced run times and increased throughput without the need for expensive new UHPLC instrumentation. While analysis speed has some value for protein separations, the principal focus is more on improving resolution of proteins from near-identical post-translationally modified impurities rather than reducing run times. A new wide pore core-shell column specifically designed to improve protein separations (Aeris WIDEPORE) has been introduced. Rather than utilize a similar morphology of small molecule core-shell columns with larger pores, a completely different particle that takes into account the slower diffusion of proteins in and out of porous particles was developed. A graphic representation of the Aeris particle is shown in Figure 1. Figure 1. Graphical representation of Aeris 3.6 µm WIDEPORE particle. A.2 µm porous shell surrounds a 3.2 µm solid core. This particle geometry is specifically designed to narrow the peak width and improve resolution of proteins and other large molecules. By greatly reducing the path length of protein diffusion, protein peaks tend to be narrower allowing for better resolution between intact proteins and their post-translationally modified impurities. The larger particle size of Aeris WIDEPORE columns generates lower column backpressures than small particle fully porous wide pore columns. This lower column backpressure enables the use of longer columns for maximizing protein resolution. In recent years several therapeutic proteins have gone off patent, allowing a large number of organizations to develop their own generic versions of these potent therapeutics. With bioequivalence being an important aspect in the regulatory success of any biotherapeutic it is of the utmost importance for researchers to develop analytical methods that fully characterize and quantitate all of the impurities present in a candidate molecule. While peptide mapping is the more common method for identifying low-level post-translational modifications (PTMs), mapping gives only imal information about protein folding and can sometimes miss N-teral and C-teral modifications. Thus, intact protein analysis by reversed phase HPLC UHPLC is usually part of the suite of testing performed on any protein therapeutic. The Aeris WIDEPORE coreshell column offers a new and improved solution for intact protein analysis by offering narrower peak widths and improved protein resolution when compared to fully porous wide pore media. This technical note will show several examples of using Aeris WIDE- PORE for analyzing PTM s on small to moderate proteins similar in size and chemical characteristics to several protein therapeutics. In addition, separations on common biogenerics will also be shown to demonstrate the improved performance of the Aeris WIDEPORE core-shell columns. Materials and Methods All chemical and standard proteins were obtained from Sigma Chemical (St. Louis, MO, USA). Recombinant human EGF and alpha interferon were purchased from R&D Systems (Minneapolis, MN, USA). Solvents were purchased from EMD (San Diego, CA, USA). Fully porous 3 Å C18 columns were purchased from various HPLC column vendors. Core-shell Aeris WIDEPORE 3.6 µm XB-C18 columns were obtained from Phenomenex (Torrance, CA, USA). 3.6 µm Core-Shell Particle 3.2 µm Solid Core.2 µm Porous Shell 3.6 µm Myoglobin samples were partially degraded by incubation at room temperature for up to a week in dilute acid. Ribonuclease samples were reduced with 1 mm DTT in mm NH 4 HCO 3 ph 8. for 2 utes at 4 ºC; reduced/non-reduced mixtures were generated by spiking different ratios of the native to the reduced sample prior to injection on HPLC. Different protein samples were analyzed on an Agilent 12 HPLC system with autosampler, column oven, solvent degasser, and UV detector set at 214 nm. Data was collected using ChemStation software (Agilent, Santa Clara, CA, USA). Mobile phases used were.1% TFA in water (A) and.8% TFA in acetonitrile (B). Different gradients, flow rates and column temperatures were listed with the corresponding chromatograms. Page 1 of 2

Results and Discussion Intact protein analysis is performed on recombinant proteins to quantitate the purity of a protein and potentially identify any specific impurities in a sample. For most purified proteins the typical impurity is a post-translationally modified version of the protein or an improperly folded species of the protein. Since such PTM impurities are chemically similar to the intact therapeutic protein, achieving chromatographic separation by HPLC or UHPLC between the two species can be a challenge. Separation and quantitation of PTM proteins can be especially difficult for larger proteins since chemical differences induced by a single modification have a smaller net effect. For effective quantitation of impurities, a wide pore reversed phase media must maximize both efficiency and selectivity. Aeris WIDEPORE, a recently introduced line of core-shell HPLC UHPLC columns, utilizes a unique particle morphology specifically designed to reduce peak broadening resulting from slow protein diffusion in and out of the porous layer of the column (Figure 1). In addition, by using a large (3.2 µm) silica core, the resultant particle is 3.6 µm in diameter which allows for longer columns at lower backpressures. The overall result is a column that delivers a significant improvement in separation power for intact proteins and their PTM-based impurities. An example of this improvement is shown in Figure 2, where degraded myoglobin is compared between a fully porous 3. µm wide pore column and the Aeris WIDEPORE 3.6 µm column. Note the dramatically increased number of resolved impurities for the core-shell Aeris column compared to the fully porous column. An additional example where improved resolution of the core-shell Aeris WIDEPORE column leads to more accurate quantitation of impurities for biogeneric proteins is shown in Figure 3, where an intact alpha interferon sample was compared between a fully porous wide pore column and the core-shell Aeris WIDEPORE column. While resolution is not complete between the interferon peak and modified components, one can see the additional component resolved by the Aeris WIDEPORE column leading to more accurate quantitation of the impurities present. One could potentially use a longer Aeris column and a shallower gradient to further resolve the components. Another characteristic of the Aeris WIDEPORE core-shell media compared to fully porous 3 Å media is that it is significantly less hydrophobic than most fully porous media, so proteins will tend to elute at a lower percentage organic. Thus, to improve resolution on existing protein methods, one should look to lower the initial percentage organic and potentially use shallower gradients when transferring a method to Aeris WIDEPORE coreshell columns. An additional benefit of the low hydrophobicity of the column is better recovery of hydrophobic proteins. This, in combination with a well bonded inert surface and an optimized diffusion path, can lead to dramatic differences when compared to other fully porous 3 Å columns. An example of this behavior is shown in Figure 4 where epidermal growth factor (EGF) is compared between Aeris WIDEPORE 3.6 µm C4 and a fully porous 3. µm 3 Å C3 column. In this example, the difference in peak heights between the chromatograms is mostly due to adsorption of the protein on the fully porous column. For most applications tested, Aeris WIDEPORE core-shell columns deliver higher protein recovery in addition to the improved resolution that the column demonstrates. A final example to demonstrate the utility of Aeris WIDEPORE columns for intact biogeneric protein analysis is shown in Figure. In this example, RNase is reduced with DTT and different mixtures of the reduced and native protein are overlaid in the figure. Analyzing and quantitating the folding state of a recombinant protein is primarily done by reversed phase chromatography of the intact protein. This example shows how an Aeris WIDEPORE column can easily resolve folded and unfolded forms of the RNase protein making it an ideal solution for analyzing intact proteins. Figure 2. Comparison between the Aeris WIDEPORE 3.6 µm XB-C18 and a 3 Å fully porous 3. µm C18 column. A degraded myoglobin sample was used to compare performance between the two columns. Note the increase in resolution and narrow peak width of the multiple impurities partially resolved on the Aeris core-shell column. In both cases a 1 x 4.6 mm column was used. Flow rate was 1. ml/ and column temperature was 4 C. Gradient was from 3 to 6 % B in 3 utes after a 3 ute hold. Aeris WIDEPORE 3.6 µm XB-C18 2 1 1 - -1 Agilent ZORBAX 3SB 3. µm C18 2 1 1 - -1 1 bar 16 18 2 22 24 26 28 1 bar 16 18 2 22 24 26 28 Conditions for both columns: Column: Aeris WIDEPORE 3.6 µm XB-C18 ZORBAX 3SB 3. µm C18 Dimensions: 1 x 4.6 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.1 % TFA Gradient: A/B (97:3) for 3 to A/B (3:6) over 3 Flow Rate: 1. ml/ Temperature: 4 ºC Injection Volume: 2 µl Instrument: Agilent 12SL Detection: UV @ 21 nm (ambient) Sample: Degraded Myoglobin Dramatically Improved Resolving Power App ID 19836 App ID 19837 Page 2 of 6

Figure 3. Comparison between the Aeris WIDEPORE 3.6 µm XB-C8 and a 3 Å fully porous 3. µm C8 column. Interferon alpha-2a was used to compare the two columns. Note the additional impurity partially resolved by the Aeris WIDEPORE core-shell column. In both cases a 1 x 4.6 mm column was used. Flow rate was 1 ml/ and the gradient was from 3 to 6 % B in 3 utes. One could potentially use a longer Aeris column (2 x 4.6 mm) and a shallower gradient to improve resolution of the impurities. Aeris WIDEPORE 3.6 µm XB-C8 Fully Porous 3 Å 3. µm C8 1 1 1 1 App ID 19827 App ID 19828-1 1 2-1 1 2 Column: Aeris WIDEPORE 3.6 µm XB-C8 Fully Porous 3 Å 3. µm C8 Dimensions: 1 x 4.6 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.1 % TFA Gradient: A/B (7:3) to A/B (3:6) over 3 Flow Rate: 1. ml/ Temperature: 22 ºC Injection Volume: µl Instrument: Agilent 12 Detection: UV @ 214 nm (ambient) Sample: Interferon alpha-2a Page 3 of 6

Figure 4. Comparison between the Aeris WIDEPORE 3.6 µm C4 and a 3 Å fully porous 3. µm C3 column. Recombinant EGF was used to compare the two columns. Note the dramatic increase in recovery for the Aeris column and the multiple components present in the sample. In both cases a 1 x 2.1 mm column at a temperature of 4 C was used. Flow rate was.3 ml/ and the gradient was from 3 to 6 % B in 4 utes. Aeris WIDEPORE 3.6 µm C4 8 6 4 2 App ID 19838 16 18 2 22 24 26 28 Agilent ZORBAX 3SB 3. µm C3 8 6 4 Protein Adsorbed 2-2 App ID 19839 16 18 2 22 24 26 28 Column: Aeris WIDEPORE 3.6 µm C4 ZORBAX 3SB 3. µm C3 Dimensions: 1 x 2.1 mm Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.1 % TFA Gradient: A/B (97:3) for 3 to A/B (3:6) over 4 Flow Rate:.3 ml/ Temperature: 4 ºC Injection Volume: 2 µl Instrument: Agilent 12 Detection: UV @ 214 nm (ambient) Sample: Human Epidermal Growth Factor (EGF) Page 4 of 6

Figure. RNase refold assay on Aeris WIDEPORE 3.6 µm C4. Overlays of different mixtures of reduced and non-reduced RNase are shown on an Aeris 1 x 4.6 mm column. Flow rate was 1.2 ml/ and column was held at ambient temperature. The gradient was from 3 to 6 % B in 3 utes after a 3 ute hold. Intact Reduced 1 2 % 4 % 8 6 % 6 4 2 App ID 19883 14 1 16 17 18 19 2 21 22 Column: Aeris WIDEPORE 3.6 µm C4 Dimensions: 1 x 4.6 mm Part No.: F-4486-E Mobile Phase: A: Water with.1 % TFA B: Acetonitrile with.1 % TFA Gradient: A/B (97:3) for 3 to A/B (3:6) over 3 Flow Rate: 1.2 ml/ Temperature: 22 ºC Injection Volume: 2 µl Instrument: Agilent 12 Detection: UV @ 214 nm (ambient) Sample: RNase subject to reduction 1 % intact 2 % reduced 4 % reduced 6 % reduced 1 % reduced Conclusion Maximizing resolution between proteins and their modified impurities is critical in obtaining useful quantitation of posttranslational modifications of biogeneric proteins. The different applications in this technical note show the utility of Aeris WIDEPORE columns for obtaining accurate data for intact protein applications. The optimized geometry of the core-shell Aeris WIDEPORE columns, as well as good selectivities of the three separate phases offered (XB-C18, XB-C8 and C4), deliver better resolution and recovery than existing fully porous 3 Å columns for intact protein analysis. Finally, the large particle size of the Aeris WIDEPORE column delivers a significantly lower backpressure than sub-2 µm 3 Å columns which allows for more flexibility in instrument used (HPLC or UHPLC) as well as column length in developing biogeneric protein applications. Page of 6

Australia t: 2-9428-6444 f: 2-9428-644 auinfo@phenomenex.com Austria t: 1-319-131 f: 1-319-13 anfrage@phenomenex.com Belgium t: +31 ()3-24187 f: +31 ()3-2383749 beinfo@phenomenex.com Canada t: (8) 43-3681 f: (31) 328-7768 info@phenomenex.com Denmark t: 4824 848 f: 481 626 nordicinfo@phenomenex.com Finland t: +38 ()9 4789 63 f: +4 481 626 nordicinfo@phenomenex.com France t: 1 3 9 21 1 f: 1 3 9 21 11 franceinfo@phenomenex.com Germany t: 621-883- f: 621-883-11 anfrage@phenomenex.com India t: 4-312 24 f: 4-312 2411 indiainfo@phenomenex.com Ireland t: 1 247 4 f: +44 162-1796 eireinfo@phenomenex.com Italy t: 1 632711 f: 1 6327 italiainfo@phenomenex.com Luxembourg t: +31 ()3-24187 f: +31 ()3-2383749 nlinfo@phenomenex.com Mexico t: 1-8-844-226 f: 1-31-328-7768 tecnicomx@phenomenex.com The Netherlands t: 3-24187 f: 3-2383749 nlinfo@phenomenex.com New Zealand t: 9-47891 f: 9-47892 nzinfo@phenomenex.com Norway t: +47 81 2 f: +4 481 626 nordicinfo@phenomenex.com Puerto Rico t: (8) 41-HPLC f: (31) 328-7768 info@phenomenex.com United Kingdom t: 162-1367 f: 162-1796 ukinfo@phenomenex.com All other countries: Corporate Office USA t: (31) 212- f: (31) 328-7768 info@phenomenex.com www.phenomenex.com Phenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at international@phenomenex.com Ordering Information Aeris WIDEPORE 3.6 µm Minibore Columns (mm) x 2.1 1 x 2.1 1 x 2.1 2 x 2.1 XB-C18 B-4482-AN D-4482-AN F-4482-AN G-4482-AN XB-C8 B-4481-AN D-4481-AN F-4481-AN G-4481-AN C4 B-4486-AN D-4486-AN F-4486-AN G-4486-AN Aeris WIDEPORE 3.6 µm Analytical Columns (mm) 1 x 4.6 1 x 4.6 2 x 4.6 XB-C18 D-4482-E F-4482-E G-4482-E XB-C8 D-4481-E F-4481-E G-4481-E C4 D-4486-E F-4486-E G-4486-E For more information on Aeris Core-Shell HPLC UHPLC columns visit www.phenomenex.com/aeris If Aeris core-shell technology does not provide at least an equivalent separation as compared to other products of the same phase and dimensions, return the product with comparative data within 4 days for a FULL REFUND. Terms and Conditions Subject to Phenomenex Standard Terms and Conditions, which may be viewed at www.phenomenex.com/termsandconditions. Trademarks Aeris is a trademark of Phenomenex, Inc. Kinetex is a registered trademark Phenomenex in the United States, European Union, and other jurisdictions. Disclaimer Phenomenex is in no way affiliated with Agilent Technologies, Inc. Comparative separations may not be representative of all applications. 211 Phenomenex, Inc. All rights reserved. TN942111_L Page 6 of 6