ORIGINAL ARTICLE. Copyright European Society of Anaesthesiology. Unauthorized reproduction of this article is prohibited.

Similar documents
A randomised comparison between Cobra PLA and classic laryngeal mask airway and laryngeal tube during mechanical ventilation for general anaesthesia

The LMA CTrach TM, a new laryngeal mask airway for endotracheal intubation under vision: evaluation in 100 patients

The Laryngeal Mask and Other Supraglottic Airways: Application to Clinical Airway Management

Comparison of the Berman Intubating Airway and the Williams Airway Intubator for fibreoptic orotracheal intubation in anaesthetised patients.

Comparison of Three Disposable Extraglottic Airway Devices in Spontaneously Breathing Adults

ASSOCIATION BETWEEN FACTORS PREDICTING AND ASSESSING THE AIRWAY AND USE OF INTUBATING LARYNGEAL MASK AIRWAY

Citation British journal of anaesthesia, 104. pp ; 2010 is available onlin

Other methods for maintaining the airway (not definitive airway as still unprotected):

Use of the Intubating Laryngeal Mask Airway

LMA CTrach TM in patients with anticipated difficult airway: A retrospective study

Received 1 November 2009 Revised 8 December 2009 Accepted 10 December 2009

J of Evolution of Med and Dent Sci/ eissn , pissn / Vol. 3/ Issue 64/Nov24, 2014 Page 13923

Difficult Airway Management during Anesthesia: A Review of the Incidence and Solutions

I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy A Clinical Comparative Study

LMA Supreme Second Seal. Maintain the airway. Manage gastric contents. Meet NAP4 recommendations.

Recent Advances in Airway Management HA Convention 2014

Use of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway

Difficult Airway. Department of Anesthesiology University of Colorado Health Sciences Center (prepared by Brenda A. Bucklin, M.D.)

Original Article INTRODUCTION. Abstract

ISPUB.COM. M Roberts, M Mani, A Wilkes, E Flavell, N Goodwin INTRODUCTION

Comparison of the air-q ILA and the LMA-Fastrach in airway management during general anaesthesia

Unanticipated difficult tracheal intubation - during routine induction of anaesthesia in an adult patient

Deposited on: 11 February 2010

Success of Tracheal Intubation with Intubating Laryngeal Mask Airways

Brief report Failed Intubating Laryngeal Mask Airway-Guided Blind Endotracheal Intubation in a Severe Postburn Contractured Neck Patient.

International Journal of Health Sciences and Research ISSN:

Anesthetic challenges when elective case becomes emergent

Cronicon ANAESTHESIA. Khaled Mohammed Elnaghy 1 and Javier Yuste 2 * Abstract. Keywords: Intubation; Video laryngoscopes; GlideScope; LMA CTrach

Editor s key points. M. Kleine-Brueggeney 1,2, L. Theiler 1,3 *, N. Urwyler 1,4, A. Vogt 1 and R. Greif 1

EUROANESTHESIA 2007 Munich, Germany, 9-12 June 2007

DIFFICULT AIRWAY MANAGMENT. Dr.N.SANTHOSH KUMAR MD ANESTHESIA (2 nd Yr)

Airway Anatomy. Soft palate. Hard palate. Nasopharynx. Tongue. Oropharynx. Hypopharynx. Thyroid cartilage

Diagnosis & Management of the Difficult Airway

Asai and Shingu Table 1 Size selection and recommended cuff volumes Size Patients Body size Recommended cuff volumes (ml) Connector colour 0 Newborn <

University of Groningen

Comparative Evaluation of Performance of Videolaryngoscope vs Fastrach Intubating Laryngeal Mask Airway

Incidence and predictors of difficult mask ventilation and intubation

ISSN X (Print) Research Article. *Corresponding author Dr. Souvik Saha

Comparison of upper lip bite test with modified mallampati classification for prediction of difficult obstetric intubation

Clinical Study McGrath Video Laryngoscope May Take a Longer Intubation Time Than Macintosh Laryngoscope

Materials and Methods. significance of respiratory problems in anesthetized patients. 1 This study laid the groundwork for the development

Complications following the use of the Combitube, tracheal tube and laryngeal mask airway

REVISTA BRASILEIRA DE ANESTESIOLOGIA

PREDICTORS OF DIFFICULT INTUBATION: STUDY IN KASHMIRI POPULATION

Comparison of Ease of Insertion and Hemodynamic Response to Lma with Propofol and Thiopentone.

Airway Workshop Lecture. University of Ottawa

COMPARATIVE CLINICAL EVALUATION OF PROSEAL LMA WITH I - GEL AIRWAY IN PATIENTS UNDERGOING ELECTIVE SURGICAL PROCEDURES UNDER GENERAL ANAESTHESIA

Luis A. Gaitini, MD*, Boris Yanovski, MD,* Somri Mustafa, MD,* Carin A. Hagberg, MD, Pedro Charco Mora, MD, and Sonia J. Vaida, MD

We will not be using the King LTS-D in our system!

AIRWAY MANAGEMENT AND VENTILATION

Comparison of I-gel with Baska Mask Airway for Controlled Ventilation in Obese Patients Undergoing Ambulatory Surgery: A Prospective Randomized Trial

Airway Management. Teeradej Kuptanon, MD

Role of laryngeal mask airway in emergency department and pre-hospital environment

Pharyngolaryngeal Morbidity with the Laryngeal Mask Airway in Spontaneously Breathing Patients

Clinical Comparison of Lightwand-guided versus Conventional Endotracheal Intubation

Evaluation of the Intubating Laryngeal Mask Airway (ILMA) as an intubation conduit in patients with a cervical collar simulating fixed cervical spine

British Journal of Anaesthesia 102 (4): (2009) doi: /bja/aep013 Advance Access publication February 20, 2009

Clinical Study Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults

RESPIRATION AND THE AIRWAY. Editor s key points. L. Theiler 1,2 *, M. Kleine-Brueggeney 1,3, N. Urwyler 1,4,T.Graf 1, C. Luyet 1 and R.

Angkana Lurngnateetape,, MD. Department of Anesthesiology Siriraj Hospital

Use of the Intubating LMA-Fastrach in 254 Patients with Difficult-to-manage Airways

LMA Unique Airway Portfolio

Blind Insertion Airway Devices (BIAD)

The reasons 13/11/ Cost 2. Availability 3. Comparison 4. Complications 5. Knowledge. Pulmonary and critical care medicine (PCCM) fellows.

Cricoid pressure impedes placement of the laryngeal mask airway

SECURING the airway and providing adequate oxygenation

British Journal of Anaesthesia 100 (4): (2008) doi: /bja/aen002 Advance Access publication January 31, 2008

A Comparative Study of Classic LMA and Proseal LMA in Paralyzed Anaesthetized Patients

Dr.Bharghavi.M 2 nd year post graduate Dept of Anaesthesia

(ix) Difficult & Failed Intubation Queen Charlotte s Hospital

The use of AIR-Q as conduit for fiberoptic endotracheal intubation in adult paralyzed patients

Emergency Department/Trauma Adult Airway Management Protocol

Veena Mathur, Deepak Garg, Neena Jain, Vivek Singhal, Arvind Khare, Surendra K. Sethi*

Comparison of efficacy of the Laryngeal tube with the Laryngeal mask airway in securing the upper airway

The Laryngeal Tube. An Evaluation of the Laryngeal Tube During General Anesthesia Using Mechanical Ventilation

CAN DIFFICULT INTUBATION BE ACCURATELY PREDICTED USING UPPER LIP BITE TEST? ABSTRACT

Omiros Chalkeidis*, Georgios Kotsovolis, Apostolos Kalakonas, Maria Filippidou, Christos Triantafyllou, Dimitris Vaikos, Epaminondas Koutsioumpas

Tibe ProSeal Laryngeal Mask Airway

The Parker Flex-Tip Tube versus a Standard Tube for Fiberoptic Orotracheal Intubation

A study to rank predictors of Preoperative Airway Assessment on the basis of accuracy of prediction while performing Laryngoscopy in Obese patients

Difficult intubation in ENT and maxillofacial surgical patients: a prospective survey.

Comparison of the Baska â mask with the single-use laryngeal mask airway in low-risk female patients undergoing ambulatory surgery

Cricoid pressure: useful or dangerous?

ADVANCED AIRWAY MANAGEMENT

Comparison of clinical performance of i-gel with laryngeal mask airway pro-seal in elective surgery in adults

Evaluation of Baska Mask Performance in Laparoscopic Cholecystectomy

ORIGINAL ARTICLE. Shashank Chitmulwar, MD, Charulata Deshpande, MD, DA ABSTRACT. ANAESTHESIA, PAIN & INTENSIVE CARE

Materials and Methods

The Mallampati Test versus the Upper Lip Bite Test in Predicting Difficult Intubation. Chance Buttars BSN, BA Bryan College of Health Sciences

Introducing the Fastrach-LMA. Prepared by Jim Medeiros, NREMT-P Regional Field Coordinator Lord Fairfax EMS Council

Original Article. Summary. Introduction. T. Saito, 1 W. Liu, 2 S. T. H. Chew 3 and L. K. Ti 4

Comparison of the LMA Supreme vs the i-gel TM in paralysed patients undergoing gynaecological laparoscopic surgery with controlled ventilation*

Materials and Methods

Comparison of the Hemodynamic Responses with. with LMA vs Endotracheal Intubation

PROBLEM-BASED LEARNING: Airway Management in Remote Area

Comparison of the clinical performance of i-gel, LMA Supreme and LMA ProSeal in elective surgery

Nicolette Mosinski MPAS, PA-C

If you suspect airway problems, get a second opinion before you anaesthetise, not after!

Retrospective audit of the air-q intubating laryngeal airway as a conduit for tracheal intubation in pediatric patients with a difficult airway

Mouth opening with cervical collars Fig 1 Types of semi-rigid collar used (left to right): Stifneck (Laerdal Medical Corp.); Miami J (Jerome Medical);

Transcription:

ORIGINAL ARTICLE CobraPLUS and Cookgas air-q versus Fastrach for blind endotracheal intubation: a randomised controlled trial Wolfgang Erlacher, Heide Tiefenbrunner, Thomas Kästenbauer, Sylvia Schwarz and Robert D. Fitzgerald Background and objective CobraPLUS and Cookgas air-q are supraglottic airways expected to allow safe ventilation as well as reliable blind intubation. In a prospective, controlled trial, we hypothesised that quality of ventilation and success rate of blind endotracheal intubation of these new devices would be superior to the Fastrach intubating laryngeal mask airway (ILMA). When blind intubation failed the quality of fibrescopeguided intubation was investigated. To allow identification of those patients in whom blind intubation would be difficult, we investigated the predictive value of currently used predictors for ease of endotracheal intubation. Methods One hundred and eighty adult patients with documented BMI, Mallampati score, Cormack Lehane classification, interincisor gap and thyromental distance were randomised into three groups according to the device used. Ventilation conditions were rated as excellent, good or difficult. When blind intubation failed, fibrescope-guided intubation conditions were rated as well. Statistical analysis was performed by a x 2 -test. Results The quality of ventilation was excellent for all devices. Three patients in the CobraPLUS group and two patients in the ILMA and the Cookgas groups needed a slight reposition. Blind intubation through the CPLA was successful in 47%, through the Cookgas in 57%, whereas the Fastrach group had a success rate of 95%. Fibreoptic intubation was possible in all but one patient. None of the registered scores and measures allowed prediction of difficult blind intubation. Conclusion All devices appeared to be safe airways. The Fastrach ILMA proved to be a reliable facilitator for blind intubation. CobraPLUS and Cookgas air-q allowed an easy fibrescopic intubation. Failed blind intubations could not be predicted by the used parameters. Eur J Anaesthesiol 2011;28:181 186 Published online 30 December 2010 Keywords: endotracheal, intubation, laryngeal mask airway Introduction The use of a supraglottic airway device for the management of a difficult airway and as a conduit for tracheal intubation is recommended by many guidelines, e.g. that of the American Society of Anaesthesiologists. 1 In the meantime a multitude of such devices has been developed and made commercially available. The CobraPLUS (Engineered Medical Systems, Indianapolis, Indiana, USA), a new disposable supraglottic device, one of the latest developments, is an improved version of the CobraPLA. It is designed to be positioned in the hypopharynx where it abuts the structure of the laryngeal inlet. The new kinked shape of its head is supposed to facilitate insertion into the supraglottic space and to provide a better fit with anatomical structures. The circular cuff provides a seal of the upper airway to the pharynx allowing positive pressure ventilation. The possibility of blind intubation through the device is suggested by the manufacturer and was published for the CobraPLA. 2,3 From the Department of Anaesthesiology and Intensive Care, Hospital Hietzing (WE, HT, SS, RDF), Karl Landsteiner Institute of Anaesthesiology and Intensive Care (WE, SS, RDF) and Karl Landsteiner Institute of Metabolic Disorders and Nephrology, Vienna (TK), Austria Correspondence to Dr Wolfgang Erlacher, Department of Anaesthesiology and Intensive Care, Hospital Hietzing, Wolkersbergenstrasse 1, A-1130 Vienna, Austria Tel: +43 1 80110 2701; fax: +43 1 80110 2696; e-mail: wolfgang.erlacher@wienkav.at The air-q (Cookgas, St. Louis, Missouri, USA) is specifically marketed as being optimised to allow blind intubation (www.cookgas.com). Its design includes a curved shaft, the lack of a grill in the ventilating orifice and an easily removable airway adapter. However, reports and studies concerning this device are scarce in the literature, and no study has ever investigated the performance of this device. 4,5 Until now, very few articles about the CobraPLUS and the Cookgas air-q and, to our knowledge, none about blind intubation through these devices have been published. Thus, in a prospective, randomised and controlled study, we compared ease of ventilation, the success rates for blind intubation through the CobraPLUS and the Cookgas air-q in comparison to the Fastrach ILMA (Laryngeal Mask Company, Henley-on-Thames, UK) as a gold standard. When blind intubation failed, intubation was accomplished with the support of a flexible fibrescope which is supposed to facilitate successful blind intubation through the device in a high percentage of patients, even in the presence of a difficult airway. 6 10 Most anaesthetists evaluate their patients before induction of anaesthesia by means of scores and measures to predict difficult intubation. While it is evident that the prediction of a difficult blind intubation when performed with the help of a supraglottic airway would be of great value, neither was a new parameter proposed for this role nor has any of the parameters or scores which are routinely used for the detection of difficult laryngoscopic 0265-0215 ß 2011 Copyright European Society of Anaesthesiology DOI:10.1097/EJA.0b013e328340c352

182 Erlacher et al. intubation been evaluated for its ability to be indicative for this purpose. Thus, we aimed to correlate two established scores (Mallampati, Cormack Lehane) and three measures (interincisor gap, thyromental distance and BMI) with the outcome of blind intubation through the CobraPlus, the air-q and the Fastrach ILMA. Methods After ethics committee approval and signing of a written informed consent, we investigated in a prospective, controlled trial with 180 patients in three parallel groups [the American Society of Anesthesiologists (ASA) physical status I and II] scheduled for elective surgery mostly at the ear-nose-throat department of the Hospital Hietzing during 2007 and 2008 under general anaesthesia requiring tracheal intubation. The full trial protocol is available from the authors upon request. Patients with a history of gastrooesophageal reflux, pulmonary disease, cervical spine disease, pregnancy and tumours in the oropharyngeal region or any other known contraindication against the use of a laryngeal mask airway (LMA) were excluded from the study. Using a computer-generated list (MS Excel) generated by one of the authors (T.K.), the patients were randomly allocated by another author (W.E.) to one of the three equally sized groups. Demographic characteristics, type and duration of surgery were recorded. Airway classification for the prediction of a suspected difficult airway was performed using the Mallampati score, 11 the interincisor gap and the thyromental distance as described by Tse et al. before induction of anaesthesia, and with the Cormack Lehane score 12,13 after the application of neuromuscular blocking drug. Patients were perorally pre-medicated with bromazepam (3 6 mg). Following the application of routine anaesthetic monitoring, general anaesthesia was induced by bolus intravenous administration of fentanyl (2 3 mg/ kg), propofol (3 mg/kg) and rocuronium bromide (0.5 mg/ kg). Anaesthesia was maintained with 60% nitrous oxide, propofol (300 400 mg/h) and supplementary fentanyl bolus when required. Neuromuscular monitoring was routinely used in all our patients and onset of neuromuscular block was verified before laryngoscopy was performed. One and a half minutes after administration of the neuromuscular blocking drug, direct laryngoscopy for the Cormack Lehane classification was performed to assess ease or difficulty of intubation. According to patient randomisation, one of the devices was inserted. The size of the laryngeal mask was chosen according to the patient s weight and in conformity with the manufacturer s recommendations. In order to make insertion easier and less traumatic, the airways were lubricated with a lidocain gel. Insertion was accomplished with the patient s head in a neutral or light sniffing position. Successful placement was confirmed by the presence of bilateral chest wall movement and the occurrence of a square wave trace on the capnograph during manual ventilation. Quality of ventilation with the airway was classified on a scale from 1 (excellent ventilation, perfect seal), to 2 (good ventilation, small leakage), to 3 (inadequate ventilation, negative capnography, reposition necessary). Then, the tracheal tube was slowly inserted through the device with the tube connected to the respirator system to allow continuation of ventilation. Oesophageal intubation was assumed when the capnographic trace disappeared. 14 17 Immediate auscultation of the lungs and the stomach confirmed incorrect position of the tube. In such a case, a thin suction tube was inserted through the tracheal tube and the air was deflated from the stomach before the tube was withdrawn. The patient s head position was optimised and the position of the device was changed (deeper insertion or withdrawal) for a new attempt. After three failed attempts, the procedure was abandoned and a fibreoptic-guided intubation through the LMA was performed. The quality of fibrescope-guided intubations was rated: I (direct access), II (requiring minor corrections), III (difficult), IV (impossible). The devices were then deflated and removed leaving the endotracheal tube in place using the rods supplied by the manufacturers. For intubation with the Fastrach ILMA, a special, flexible and reusable silicone spiral tube (LMA tube) as recommended and provided by the manufacturer was used. Intubations through the CobraPLUS and the Cookgas air-q were performed with a regular, disposable polyvinyl chloride (PVC) tube (Rüsch GmbH, Kernen, Germany) in the usual sizes. For removal of the tube, the rod was used. All study cases were performed in the presence of the study author and an independent and skilful co-investigator. Statistical analysis Because no relevant data on success rates for the new devices have yet been published, no power analysis could be accomplished. Therefore, to estimate group size, x 2 - test using GPower V.3.2.1. (http://psycho.uni-duessel dorf.de/aap/projects/gpower/) was performed anticipating a medium-sized effect (w ¼ 0.3) for a significance level of P value less than 0.05. With this estimate, a total number of 172 patients is regarded to be necessary for a power of 95%. Statistical calculations were done with Medcalc (www.medcalc.be). Distribution of data was tested with a Kolmogorov Smirnov test. Since BMI was normally distributed, the differences between patients intubated with the Fastrach or CobraPlus system were calculated with a Student s t-test and results were presented as mean SD. Frequency data were tested for statistical difference with a x 2 -test and were presented as absolute values for demographic data and predictors throughout the tables. A P value of less than 0.05 was considered statistically significant.

Laryngeal mask airway for blind intubation 183 Fig. 1 Enrollment Assessed for eligibility (n= 211) Excluded (n= 31) Did not meet inclusion criteria (n= 7) Declined to participate (n= 24) Randomised (n= 180) Allocation Group 1 (n= 60) Received allocated intervention (n= 60) Did not receive allocated intervention (n= 0) Group 2 (n= 60) Received allocated intervention (n = 60) Did not receive allocated intervention (n= 0) Group 3 (n= 60) Received allocated intervention (n= 60) Did not receive allocated intervention (n= 0) Follow-Up Lost to follow-up (n= 0) Discontinued intervention (n= 0) Lost to follow-up (n= 0) Discontinued intervention (n= 0) Lost to follow-up (n= 0) Discontinued intervention (n= 0) Analysis Analysed (n= 60) Analysed (n= 60) Analysed (n= 60) CONSORT 2010 flow diagram. Results One hundred and eighty patients were randomised into three equally sized groups (n ¼ 60). A CONSORT flow chart is shown in Fig. 1. Demographic data, BMI, Mallampati score, thyromental distance, interincisor gap and Cormack Lehane classification between groups were comparable and are shown in Tables 1 and 2. The quality of ventilation was excellent in most patients in all study groups. In the CobraPLUS group, a slight reposition (2) of the device was necessary in three patients (5%), in 95% we found excellent conditions (1). Only two patients from the Cookgas air-q and the Fastrach group needed a correction of the mask (2), 97% were rated excellent (1). Table 1 Demographic data: gender and BMI for successful and failed intubations with the three devices Fastrach Total 31/29 25.2 4.3 Successful 30/27 25.2 4.2 Failed 1/2 30.0 7.9 CobraPLUS Total 36/24 26.0 4.2 Successful 17/11 26.3 4.4 Failed 19/13 25.6 4.0 Air-Q Total 32/28 26.3 4.7 Successful 21/14 26.1 4.4 Failed 12/14 26.4 5.0 M/F BMI Blind intubation through the CobraPLUS was successful in 28 patients (47%) and failed in 32 (53%). With the Cookgas air-q, 34 blind intubations (57%) were successful and 26 (43%) failed. The Fastrach group had a success rate of 95% (n ¼ 57), although the intubating procedure had to be repeated for a second or third try (up/down and Chandy manoeuvres) in seven patients (12%). Sex (P ¼ 0.942), age (P ¼ 0.481) and BMI (P ¼ 0.429) had no influence on the success of blind intubation. Fibrescope-guided intubations were easily performed in all three patients with failed blind intubation in the Fastrach group (2 I, 1 II) (Fig. 2). Of the 32 patients with failed blind intubation in the CobraPLUS group, 27 patients were fibrescoped easily (18 I, 9 II) and five patients with difficulty (III). None of them failed (IV). Of the 26 patients of the Cookgas air-q group, 22 were classified as easy (14 I, 8 II) and three as difficult (III). In one patient, the fibrescope-guided intubation failed (wrong LMA size). The prediction scores for anticipation of a difficult airway did not show any statistically relevant coincidence between the groups of successful and failed intubation (Mallampati score P ¼ 0.71; Cormack Lehane classification P ¼ 0.22; interincisor gap P ¼ 0.67; thyromental distance P ¼ 0.71). Frequencies of distribution of the different grades either within the total groups or the

184 Erlacher et al. Table 2 Predictors for difficult airway: successful and failed intubations MP I MP II MP III MP IV CL I CL II CL III CL IV TMD <6 cm TMD 7 cm TMD >7 cm IIG 4 cm IIG ¼ 4 6 cm IIG 6cm Fastrach Successful 29 21 6 1 23 18 6 10 8 38 11 9 47 1 Failed 1 2 0 0 0 3 0 0 1 1 1 0 3 0 CobraPLUS Successful 14 10 4 0 7 13 7 1 5 18 5 5 22 1 Failed 16 11 4 1 15 9 4 4 2 20 10 3 29 0 Air-Q Successful 17 11 6 0 12 15 4 3 8 19 7 4 29 1 Failed 14 9 3 0 7 10 8 1 5 18 3 7 17 2 CL, Cormack Lehane; IIG, interincisor gap; MP, Mallampati; TMD, thyromental distance. Fastrach: 60 patients [57 successful blind intubations (95%), seven after repetition, three failed); fibrescope-guided intubations: easy in three cases (2 I, 1 II). CobraPLUS: 60 patients [28 successful blind intubations (47%); failed blind intubations in 32 patients; fibrescope-guided intubations: easy in 27 cases (18 I, 9 II) and difficult in five cases (III), no failure (IV). Cookgas air-q: 60 patients [34 successful blind intubations (57%); failed blind intubations in 26 patients; fibrescope-guided intubations: easy in 22 cases (14 I, 8 II), difficult in three cases (III), failed in one case (IV). patients who were intubated successfully showed no significant differences (Table 3). In one patient with failed intubations in the CobraPLUS group, we noticed a damage of the cuff of the endotracheal tube after three failed attempts. Discussion The major finding of our study was that both LMA devices, the CobraPLUS and the Cookgas air-q, failed to be reliable facilitators for blind intubation. In contrast, the Fastrach ILMA had a 95% success rate and proved to be the best approach among those tested for securing the airway and facilitating blind intubation. The additional use of a fibrescope led to a near-100% success rate. The predictors currently applied for detecting difficult intubation proved to be unsuited for predicting the ease of an intubation through an LMA. Fig. 2 18 16 14 12 10 8 6 4 2 0 Fastrach CobraPlus Air-Q I - Direct access II - Minor corrections III - Difficult IV - Impossible The quality of fibrescope-guided intubations in cases of failed blind intubations. A great variety of airway devices have been marketed and tested during the last few years. According to the difficult airway algorithm issued by the ASA, the use of a supraglottic airway is strongly recommended in the presence of a difficult airway. 1,18 The utility of the Fastrach ILMA in cases of difficult airway management has been investigated in many studies, and these results were reproducible in our study. Both the air-q and the CobraPLUS are relatively new perilaryngeal airways. Although no published data are available for the CobraPLUS, its predecessor, the CobraPLA, is discussed controversially in the literature. In a number of studies, the CobraPLA was described as an airway allowing easy placement and adequate ventilation during both controlled and spontaneous ventilation. 22,23 Compared with other supraglottic devices the CobraPLA appears to be as effective in establishing an adequate airway as the other laryngeal masks tested and even seems to have certain advantages, such as easier insertion and better airway sealing capabilities. 24 The question remains whether a higher airway seal combined with higher airway pressures can be seen as a real advantage, as it is known that higher airway pressures cause gastric inflation associated with the higher risk of pulmonary aspiration of gastric contents. This concern is strongly supported by Cook and Lowe 25 who halted their study after they encountered two cases of pulmonary aspiration. Data concerning the use of the Cookgas air- Q LMA are scant. To our knowledge, only two case series were reported in the literature. 3,4 The device is designed to allow easy fibreoptic intubation as it combines the features of the soft airway tube and the ability to facilitate intubation, for example, the lack of a grill in the ventilation orifice. To our knowledge, we present the first study comparing the ability of these devices in regard to ease of ventilation and facilitation of blind or fibreoptic intubation. Our experience with the CobraPLUS ventilatory quality was comparable with the findings in previous investigations with the predecessor CobraPLA. No serious ventilation problems were recorded in any of our study cases. In a recent study with the CobraPLA in which the device was used as a bridge to blind or fibreoptic-guided

Laryngeal mask airway for blind intubation 185 Table 3 Significance levels (P value) of frequencies of distribution of different grades in the scores between groups and of success rate (x 2 -test) MP CL TMD IIG Group (P) 0.94 0.23 0.55 0.67 Success (P) 0.83 0.44 0.62 0.84 CL, Cormack Lehane; IIG, interincisor gap; MP, Mallampati; TMD, thyromental distance. intubation, the success rate for blind intubation was 36% only, whereas it was 83% for the fibreoptic techniques. 2 In our study, the success rate for blind intubation with the CobraPLUS increased up to 47% and reached 100% for the fibrescope-guided intubations. This might be due to the improved shape of the CobraPLUS which should result in a better fit of the device in the supraglottic space. However, a success rate of less than 50% still appears to be a rather poor outcome for an emergency device. The air-q showed a performance similar to the Cobra- PLUS regarding quality of ventilation, but was slightly better for blind intubation. However, 43% failed attempts seems rather high considering that this device is used in an emergency setting. In contrast to the variable success rates in blind intubation, the use of the fibrescope led to almost 100% successful intubations (Fig. 2). Thus, whenever intubation via laryngeal mask airway is planned, it seems reasonable to prepare a fibrescope for additional help. This multimodal approach ensured a high success rate independent of the type of LMA and the presumed airway difficulty in our patients. The reason for the one failed fibrescope-guided intubation might have been the use of a wrong device size, which was chosen according to the manufacturer s recommendation relating the LMA size to the patient s weight. In the presence of a short and heavy patient, this might not be appropriate. We report the damage of the cuff of an endotracheal tube following three failed attempts of blind intubation with the CobraPLUS device. This was possibly due to the fact that the lubricating gel was used up during the preceding attempts. Traumatisation by supralaryngeal airways and blind intubation have been described in the literature 23,24,26 and comparison of the devices tested would have been interesting. However, as many of our patients underwent surgery of the pharyngolaryngeal region, we were unable to distinguish between the causes of patients postoperative discomfort. When a difficult airway is anticipated, an important issue is the use of predictive scores to allow preparation for adequate management. Although routinely applied for the prediction of difficult intubation, no such parameter has been validated for predicting difficulties in blind intubation through a laryngeal mask airway. In a first step in the development of such parameters, we aimed to evaluate four scores and measures commonly used for the prediction of difficult endotracheal intubation for their ability to also predict difficult blind intubation through an LMA. However, no correlation between any of these parameters and failures that actually occurred was detectable. Therefore, the question of an effective predictor for a difficult intubation through an LMA remains unanswered and awaits the development of more specific parameters. 19 21 A possible bias in our study may arise from the problem of blinding. In this clinical study, it was practically impossible to evaluate the efficacy of ventilation without unblinding the assessor. However, assessment was nonetheless strict and verified by a second investigator. Also, as the number of patients with difficult anatomy was small, we have to point out that any conclusion on this group remains speculative and will require further studies specifically designed for such patients. The three devices are delivered by the manufacturers in different packages. Although the Fastrach ILMA is provided as a complete emergency set consisting of the ILMA, a special reusable silicone tube (both in different sizes) and the LMA rod for pushing out the tube when the ILMA is to be removed, the air-q is only supplied with a rod, and the CobraPLUS without any supplemental material. Therefore, it may seem unfair to compare the more flexible tube of the Fastrach with the regular PVC endotracheal tubes which are used with the two other devices. However, we compared the systems as they are available on the market, thus adhering to the manufacturers recommendations. We conclude that all three devices appeared to be safe supraglottic airways in general anaesthesia. The Fastrach ILMA, in contrast to the CobraPLUS and Cookgas air-q, proved to be a reliable facilitator for blind intubation. The multimodal approach using a fibrescope and a laryngeal mask airway leads to a very high success rate in our patients independent of the device used. Failed intubations with any of the devices could not be predicted by the usual prediction scores. Acknowledgements The authors wish to thank the anaesthesia and surgical staff of Hospital Hietzing for their assistance in performing this study. This study was financed in total by the Karl Landsteiner Institute of Anaesthesiology and Intensive Care, an institute of the Karl Landsteiner Society, a non-profit organisation for the promotion of medical research. None of the authors has any conflict of interest with the results published in this study. References 1 Benumof JL. ASA difficult airway algorithm. New thoughts and considerations. In: Hagberg CA, editor. Handbook of difficult airway management. Philadelphia: Churchill Livingstone; 2000. pp. 31 48.

186 Erlacher et al. 2 Lee JJ, Kim JA, Gwak MS, Kim MH. Evaluation of the Cobra perilaryngeal airway (CPLA) as an airway conduit. Eur J Anaesthesiol 2007; 24:852 855. 3 Ghelber O, Szmuk P, Alfery DD, et al. Use of CobraPLUS for airway management in a child with tracheomalacia. Acta Anaesthesiol Scand 2007; 51:782 783. 4 Yang D, Deng XM, Tong SY, et al. Fiberoptic intubation through Cookgas intubating laryngeal airway in two children. Anaesthesia 2009; 64:1148 1149. 5 Jagannathan N, Roth AG, Sohn LE, et al. The new air-q intubating laryngeal airway for tracheal intubation in children with anticipated difficult airway: a case series. Pediatr Anaesth 2009; 19:618 622. 6 Langensteiner H, Moller F. First experience with the laryngeal intubation mask. Anaesthesist 1998; 47:311 319. 7 Kawamura T, Amaha K, Fukutome T, et al. A multicenter study for evaluating a new intubating laryngeal mask airway. Masui 1999; 48:782 786. 8 Langeron O, Semjen F, Bourgain JL, et al. Comparison of the intubating laryngeal mask airway with the fiberoptic intubation in anticipated difficult airway management. Anesthesiology 2001; 94:968 972. 9 Ferson DZ, Rosenblatt WH, Johansen MJ, et al. Use of the LMA-Fastrach in 254 patients with difficult-to-manage airways. Anesthesiology 2001; 95:1175 1181. 10 Waltl B, Melischek M, Schuschnig C, et al. Tracheal intubation and cervical spine excursion: direct laryngoscopy vs. intubating laryngeal mask. Anaesthesia 2002; 57:221 226. 11 Mallampati SR, Gatt SP, Gugino LD, et al. A clinical sign to predict difficult tracheal intubation: a prospective study. Can J Anaesth 1985; 32:429 434. 12 El-Ganzouri AR, McCarthy RJ, Tuman KJ, et al. Preoperative airway assessment: predictive value of a multivariate risk index. Anesth Analg 1996; 82:1197 1204. 13 Rose KD, Cohen MM. The incidence of airway problems depends on the definition used. Can J Anaesth 1996; 43:30 34. 14 Linko K, Paloheimo M. Capnography facilitates blind nasotracheal intubation. Acta Anaesthesiol Belg 1983; 34:117 122. 15 Grmec S, Mally S. Prehospital determination of tracheal tube placement in severe head injury. Emerg Med J 2004; 21:518 520. 16 Huitink JM, Balm AJ, Keijzer C, Buitelaar DR. Awake fibreoptic intubation in head and neck cancer patients with difficult airways: new findings and refinements to the technique. Anaesthesia 2007; 62:745 746. 17 Yao YX, Jiang Z, Lu XH, et al. A clinical study of impedance graph in verifying tracheal intubation. Zhonghua Yi Xue Za Zhi 2007; 87:898 901. 18 Benumof JL. Laryngeal mask airway and the ASA difficult airway algorithm. Anesthesiology 1996; 84:686 699. 19 Iohom G, Ronayne M, Cunningham AJ. Prediction of difficult tracheal intubation. Eur J Anaesthesiol 2003; 20:31 36. 20 Shiga T, Wajima Z, Inoue T, Sakamoto A. Predicting difficult intubation in apparently normal patients: a meta-analysis of bedside screening test performance. Anesthesiology 2005; 103:618 619. 21 Merah NA, Wong DT, Ffoulkes-Crabbe DJ, et al. Modified Mallampati test, thyromental distance and inter-incisor gap are the best predictors of difficult laryngoscopy in West Africans. Can J Anaesth 2005; 52:291 296. 22 Gaitini L, Yanovski B, Somri M, et al. A comparison between the PLA Cobra and the Laryngeal Mask Airway Unique during spontaneous ventilation: a randomised prospective study. Anesth Analg 2006; 102:631 636. 23 Turan A, Kaya G, Koyuncu O, et al. Comparison of the laryngeal mask (LMA) and laryngeal tube (LT) with the new perilaryngeal airway (CobraPLA) in short surgical procedures. Eur J Anaesthesiol 2006; 23:234 238. 24 Akca O, Wadhwa A, Sengupta P, et al. The new perilaryngeal airway (CobraPLUS TM ) is as efficient as the laryngeal mask airway (LMA TM ) but provides better airway sealing pressures. Anesth Analg 2004; 99:272 278. 25 Cook TM, Lowe JM. An evaluation of the Cobra perilaryngeal airway: study halted after two cases of pulmonary aspiration. Anaesthesia 2005; 60:791 796. 26 van Zundert A, Al-Shaikh B, Brimacombe J, et al. Comparison of three disposable extraglottic airway devices in spontaneously breathing adults: the LAM-Unique, the Soft Seal Laryngeal Mask, and the Cobra perilaryngeal airway. Anesthesiology 2006; 104:1165 1169.