Characterisation of a Cu selective resin for use in the production of Cu isotopes

Similar documents
Zinc isotopes in the Seine River water, France: a probe of. anthropogenic contamination

Elemental Scientific. seafast S2. Elution Profiles. Elemental Scientific

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

BabyBio IMAC columns DATA SHEET DS

SECTIOn 3. Multi-Element ClP Standards for ICP & ICP-MS

COMPARATIVE ANALYSIS FOR MACRO AND TRACE ELEMENTS CONTENT IN GOJI BERRIES BETWEEN VARIETIES FROM CHINA AND R. MACEDONIA

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

The Development of LC/MS Methods for Determination of MDMA (Ecstasy) and Metabolites in Biological Samples

Junias Adusei-Gyamfi. Supervisors: University of Lille: Justine Criquet, Baghdad Ouddane TU Delft: Bas Heijman, Luuk Rietveld. Second DOC2C's workshop

Analysis of Micronutrients in Milk by Flame Atomic Absorption Using FAST Flame Sample Automation for Increased Sample Throughput

Measuring Lipid Composition LC-MS/MS

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Europium Labeling Kit

For Research Use Only Ver

you-try-it-02.xlsx Step-by-Step Guide ver. 8/26/2009

Performance Characteristics of the Agilent High Matrix Sample Introduction (HMI) Accessory for the 7500 Series ICP-MS. Product Overview.

Determination of metals in industrial wastewaters by microwave plasmaatomic emission spectrometry

Title: Column Chromatography of Green Fluorescent Protein

DetergentOUT GBS10 Spin Plates

Tailor made sample preparation for unusual bioanalytical research. Erik Baltussen, PhD

Analysis of trace elements in nutraceuticals in compliance with USP chapter <2232> Elemental Contaminants in Dietary Supplements

Fig. 1: Chemical structure of arachidonic acid COOH CH 3

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

Characterization of the DNA-mediated Oxidation of Dps, a Bacterial Ferritin

EXPERIMENT 13 QUALITATIVE ANALYSIS

Note: The use of different equipment configurations (standard, XI, PlasmaScreen...) will treat different experiment Other services ICP- MS

DELFIA Tb-DTPA ITC Chelate & Terbium Standard

Mike Hinds, Royal Canadian Mint

Analysis of formaldehyde in blood of rats during and after inhalation exposure

using the Agilent 7696A Sample Prep

NCUT National Centre for Upgrading Technology

Hot water extraction of inner and outer bark of Norway Spruce (Picea abies)

SPECIAL ASPECTS OF ASSESSING THE ELEMENTAL COMPOSITION OF PHYTOPLANKTON AND SESTON USING NEUTRON ACTIVATION ANALYSIS

INSTRUCTION MANUAL. RNA Clean & Concentrator -5 Catalog Nos. R1015 & R1016. Highlights. Contents

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

Multi Analyte Custom Grade Solution

Application Note. Author. Abstract. Introduction. Food Safety

SUPPORTING INFORMATION. Zinc isotope fractionation as an indicator of geochemical attenuation processes

EASIMIP TM PATULIN Product Code: P250 / P250B

Elemental Scientific. Automated Speciation. prepfast-ic Chromium Speciation for Toy Materials (EN 71-3) ICP ICPMS AA

Systematic Evaluation of Solid Phase Extraction (SPE) Chemistries for the Determination of Acidic, Neutral, and Basic Drugs

Supplemental Data. Deinlein et al. Plant Cell. (2012) /tpc

CERTIFICATE OF ANALYSIS. tel: fax:

US EPA SW-846 Method 6010D using the Thermo Scientific icap 7400 ICP-OES Duo

Pinpoint Slide RNA Isolation System II Catalog No. R1007

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

WAGENINGEN EVALUATING PROGRAMS FOR ANALYTICAL LABORATORIES. Certificate of Analysis. International Soil-Analytical Exchange REFERENCE MATERIAL

UBM procedure for the measurement of inorganic contaminant bioaccessibility from solid matrices

DETERMINATION OF PHYTIC ACID IN URINE BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY

Identification and Quantification of Psychedelic Phenethylamine 2C Series using SPE and LC-MS/MS

Supporting Information. 58 Pages. 6 Figures 4 Tables

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Supplementary Materials for:

Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially- Viewed Plasma

Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations

Journal of Chemical and Pharmaceutical Research

CORESTA RECOMMENDED METHOD N 39

Analysis of Blood Serum on the Liberty Series II ICP OES with the Axially-Viewed Plasma

Evaluating the performance of the OneNeb Series 2 Nebulizer with PerkinElmer Optima 7/8x00 Series ICP-OES systems

Detect, remove and re-use: a new paradigm in sensing and removal of Hg (II) from wastewater via SERS-active ZnO/Ag nano-arrays

Application Note novaa 800 D. Determination of Macro and Trace Minerals as well as Toxic Trace Metals in Powdered Milk. Challenge.

3-Acetyldeoxynivalenol. 15-Acetyldeoxynivalenol

The Removal of Metal Ions (Cu 2+ and Zn 2+ ) using Waste-reclaimed Adsorbent for Plating Wastewater Treatment Process

Purolite Ion Exchange Resins for Recovery and Purification of Rhenium

Single particle ICPMS based methods for tracking environmental leaching of nanoparticles from consumer products

It is recommended to use titanium coils. ph meter to control ph of the process. It is advised to use an automatic dosage for the maintenance products.

Zinc T mg/l Zn Zincon

Food safety is an area of growing concern as a result of pollution,

Noora Perkola Finnish Environment Institute. Nordic MS Symposium November 9, 2011, Båstad, Sweden

Matrix Interferences in ICP-MS: Causes, Effects, and Strategies to Reduce or Eliminate Them

Bottom Ash Data Week 38

Sugars in Honey Using HPAE-PAD: What Is the Best Column?

Bottom Ash Data Week 30

Utilization of iodide as a perchlorate-laden resin regenerating solution and isolation of perchlorate from simulated ground water samples

QUANTITATIVE ANALYSIS OF STEROIDS

Analysis of Organic Fertilizers for Nutrients with AAnalyst 800 Atomic Absorption Spectrophotometer

Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis

Simultaneous Quantitative Analysis of Total Catecholamines and Metanephrines in Urine Using 500 MG CLEAN UP CCX2 and LC-MS/MS

LC/MS Biomarker Assay Validation Strategies Using Surrogate Matrix and Surrogate Analyte Approaches

Superose 6 Increase columns

Prerequisites Protein purification techniques and protein analytical methods. Basic enzyme kinetics.

Caution: For Laboratory Use. A product for research purposes only. Eu-W1284 Iodoacetamido Chelate & Europium Standard. Product Number: AD0014

Fatty Acid Mass Spectrometry Protocol Updated 10/11/2007 By Daren Stephens

Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS

Taking the Complexity out of SPE Method Development

DELFIA Tb-N1 DTA Chelate & Terbium Standard

Routine Analysis of Fortified Foods using the Agilent 7800 ICP-MS

Radio-isotopes in Clinical Medicine

Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography

Determination of Copper in Green Olives using ICP-OES

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

Electronic Supporting Information

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

Analysis of Milk for Major and Trace Elements by ICP-MS

A New RP-HPLC Method for the Simultaneous Estimation of Naltrexone Hydrochloride and Bupropion in Its Pure and Pharmaceutical Dosage Form

Determination of available nutrients in soil using the Agilent 4200 MP-AES

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Transcription:

Characterisation of a Cu selective resin for use in the production of Cu isotopes

Resin characterisation Selectivity Interferences with Ni or Zn Column Experiments Optimisation Simulated targets Decontamination factors Outline Conversion of Cu resin eluate via AIX Other applications

D w Cu resin in HCl Figure 1: D w of Cu and selected elements on Cu resin in HCl, varying ph values, measurement via ICP-MS, each element 10µg/ml Loading conditions (> ph 2): Good selectivity for Cu over other elements tested, Some selectivity for Fe at high ph Elution: Low Cu D w at low ph, further tests with 4, 6 and 8 M HCl

D w Cu resin in HNO 3 Figure 2: D w of Cu and selected elements on Cu resin in HNO 3, varying ph values, measurement via ICP-MS, each element 10µg/ml Loading conditions (> ph 2): Good selectivity for Cu over all other elements tested Elution: Low Cu D w at low ph

D w Cu resin in H 2 SO 4 Figure 3: D w of Cu and selected elements on Cu resin in H 2 SO 4, varying ph values, measurement via ICP-MS, each element 10µg/ml Loading conditions (> ph 2): Good selectivity for Cu over most other elements tested Limited selectivity for Fe Elution: Low Cu D w at low ph

D w Cu interferences - HCl ph 2 Ni interference Zn interference Figure 4: D w of Cu on Cu resin in HCl (ph 2) in presence of various amounts of Ni Figure 5: D w of Cu on Cu resin in HCl (ph 2) in presence of various amounts of Zn For high amounts of Ni or Zn D w (Cu) remains > 1000 in ph 2 HCl For up to 1 g target material per g resin only negligible interference

Conclusions I Stable, high Cu D w values at ph > 2 for all acids Good selectivity for Cu over tested elements No selectivity for Zn or Ni No interference on Cu extraction by elevated amounts of Ni or Zn Tested up to 1g Ni or Zn per g of resin HCl system chosen for radiopharmaceutical application Loading solution: HCl ph 2 (or higher) Elution with HCl (elevated concentration)

First approach Loading : L1 Rinsing : R1 & R2 Elution : E1 & E2 Figure 6: Scheme of elution conditions first approach

Elution study 2 ml CU resin column Elution with 6 M HCl 0.8 0.7 0.6 Cu - 63 Ni - 58 L1 =5 ml simulated Ni Target Yield 0.5 0.4 Ni - 60 Zn - 64 R1 = 10 ml HCl ph 2 R2 = 10 ml HCl ph 2 0.3 0.2 0.1 E1 = 5mL HCl 6 M E2 = 5mL HCl 6M 0 L1 R1 R2 E1 E2 Elution with 8 M HCl Figure 7/8 : Elution study; simulated Ni targets (200 mg Ni, traces of Zn, Cu), elution with 6M HCl and 8M HCl Yield 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 Cu - 63 Ni - 58 Ni - 60 Zn - 64 L1 =5 ml simulated Ni Target R1 = 10 ml HCl ph 2 R2 = 10 ml HCl ph 2 E1 = 5mL HCl 8 M E2 = 5mL HCl 8 M 0.1 0 L1 R1 R2 E1 E2 8M HCl allows for elution in smaller volume Clean Cu fraction

Elution study - irradiated Ni target Irradiation of a Ni foil (10 mg) : (ø =13 mm, 0.025 mm thickness) Cyclotron BC1710 at Forschungs Zentrum Jülich E p = 15 MeV 1 h; 0.5 ma Additionally 170 mg non-irradiated Ni-foil added

Elution study irradiated Ni target % yield 100 90 80 70 60 50 40 30 20 10 0 L1 R1 R2 E1 E2 Figure 9 : Elution study, irradiated Ni nat target ~100 % Cu in E1 ~100 % Ni in L1 & R1 Cu 61 Co 55 Co 57 Ni 57 Loading: L1 : 5 ml HCl ph 2 Rinsing: R1 : 10 ml HCl ph 2 R2 : 10 ml HCl ph 2 Elution: E1 : 5 ml HCl 8 M E2 : 5 ml HCl 8 M Very pure Cu fraction Elution and rinsing volumes to be optimized

Eluate from loading : L 1 5 ml ph 2 HCl

Rinsing : R1 10 ml HCl ph 2

Elution : E1 5 ml HCl 8M 14

Optimization of Cu elution volume Figure 10/11: Elution study, simulated Ni target, varying Cu resin amounts, gravity flow Use of smaller columns allows reducing Cu elution volume Near quantitative Cu recovery in ~1 ml 8M HCl No impact on Cu purity

Optimization of Cu elution volume vacuum-assisted flow Figure 12/13 : Elution study, simulated Ni and Zn target, 350 mg Cu resin Flow rate: 1 ml/min (rinsing up to 6 ml/min) 0.35g CU resin columns > 90% recovery in 1 ml 8M HCl, quantitative recovery in 1.5 ml Simulated Ni and Zn targets (200 mg target material) No impact on purity

Optimized method Figure 14: Scheme of elution conditions optimized method

Decontamination factors D f Flow rate: 1 ml/min (rinsing 6 ml/min) 0.35 g columns Loading solution: Ni, Zn, Co, Ga and Au in 5 ml HCl ph 2 Separation following optimized method ICP-MS measurement Calculation of deconfactors D f for Cu fractions Fraction E1 (0.5 ml 8M HCl): D f : Ni, Co & Zn > 20 000 D f : Au & Ga > 10 000 Fraction E2 (0.5 ml 8M HCl): D f : Ni > 20 000, Co > 40 000, Zn > 70 000, Au > 50 000, Ga > 10 000

Conclusion II 350 mg columns allow for Cu elution in small volume Vacuum assisted flow Rapid separation Quantitative recovery of Cu in 1 1,5 ml 8M HCl Cu yield > 90% in 1 ml 8M HCl 97,6% ± 2,3% (k = 1, N=25) in 1.5 ml 8M HCl Pure Cu fraction D f (ICP-MS) -spectrometry Obtained Cu suitable for labelling (ARRONAX) Ni recovered in small volume of 8M HCl 10 13 ml load and rinse Further purification for reuse e.g. via diect load on AIX

Conversion of Cu eluate Aim: recovery of Cu in small volume of dilute HCl, water or NaCl solution Anion exchange resins (AIX) shows necessary selectivity Cu eluate (1 1,5 ml 8M HCl) from Cu resin column directly loaded onto small AIX column Rinse with 8M HCl Elution with deion. water

Elution study - AIX 0.8 Elution study - AIX Yield 0.7 0.6 0.5 0.4 0.3 0.2 Cu Co Zn Ni Ga Au 0.1 0 Load: 1 ml 8M HCl R 1: 0.5 ml 8M HCl R: 0.5 ml 8M HCl E 1: 0.2 ml water E 2: 0.2 ml water E 3: 0.2 ml water E 4: 0.2 ml water E 5: 0.2 ml water E6: 1 ml water Figure 15: Elution study, AIX, various elements, 400 mg A8 Resin (200 400 mesh, Eichrom Technologies) 400 mg AIX (A8) Cu elution in 0.6 0.8 ml water Anion exchange conversion step gives additional decontamination from Ni, Zn, Au

Cu fraction conversion step Direct load of Cu eluate onto anion exchange resin / elution with water or saline solution Further purification from matrix elements and organics Cu yield in 0.7 ml water: 93,8 ± 6,4% (k = 1, N=25) Fig 16: Conversion step using anion exchange, 400 mg A8 resin (Eichrom Technologies), 200 400 mesh

Vacuum-assisted flow CU resin (350 mg) Full method Load from 1-2 ml HCl ph2 Rinse with 5 ml and 3 ml HCl ph 2 Load and rinse contain ~100% Ni ( Ni-64 recovery) Cu elution in 1 1.5 ml 8M HCl Cu yield > 95%; high decontamination factors Conversion on AIX (400 mg) Load from 1 1.5 ml 8M HCl Rinse with 0.6 ml 8M HCl and < 0.2 ml water Cu elution in 0.6 0.8 ml water (or saline solution) Cu yield > 90%; add. decontamination (Ni, Zn, Au, organics) Overall separation time: <10 minutes

Other applications Removal of trace Cu-64 before Ni-64 plating Cu concentration and purification for analytical purpose (e.g. Cu in sea water) Fig 17: Elution study, 10 ml spiked sea water, 350 mg CU resin column, vacuum assisted flow 10 ml sea water (ph 2.3) Cu yield > 95% in 1 ml 8M HCl Pure Cu fraction