Distribuido en España por: INGENIERIA ANALITICA S.L Tel: Fax:

Similar documents
25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Vitamin A-E Serum HPLC Analysis Kit

ZIVAK TECHNOLOGIES. Multitasker-LC Walk Away UHPLC Analyzer For LC-MS/MS

SCIEX Vitamin D 200M Assay for the Topaz System

PKU (Phenylketonuria) Serum HPLC Analysis Kit User Manual

PKU (Phenylketonuria) Serum LC-MS/MS Analysis Kit User Manual

VITAMINES A / E IN PLASMA BY UV - FAST CODE Z18610

LC-MS/MS Method for the Determination of Tenofovir from Plasma

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

Analysis of Common Sweeteners and Additives in Beverages with the PerkinElmer Flexar FX-15 System Equipped with a PDA Detector

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

All stocks and calibration levels were prepared in water: methanol (50:50) v/v to cover range of all steroid concentrations (refer Table 1).

HVA, VMA and 5-HIAA in Urine

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Agilent 1220 Infinity LC System Performance Specifications

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Analysis of bisphenol A leaching from baby feeding bottles

Monitoring of plasmatic concentrations of AEDs is important to improve patient s theraphy.

Dienes Derivatization MaxSpec Kit

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

Methodology Report Total 25-Hydroxyvitamin D Determination by an Entry Level Triple Quadrupole Instrument: Comparison between Two Commercial Kits

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Disclosure: No conflict of interests to disclose

Organic Acid Urine LC-MS/MS Analysis Kit

Mycotoxin Analysis in Peanut Butter Using Captiva EMR Lipid Cleanup and LC/MS/MS

Analysis of Isoflavones with the PerkinElmer Flexar FX-15 UHPLC System Equipped with a PDA Detector

Fast quantitative Forensic Analysis of THC and its Metabolites in Biological Samples using Captiva EMR- Lipid and LC/MSMS

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

LCMS Vitamin D3 Method development

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Comparison of a UPLC Method across Multiple UHPLC Systems

25 OH Vitamin D Rapid Test

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

DBC 25-Hydroxyvitamin D

AMIODARONE and DESETHYLAMIODARONE IN PLASMA BY UV FAST CODE Z33610

25 OH Vitamin D Rapid test

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

VITAMIN B1 IN WHOLE BLOOD BY FLUORIMETRY - FAST Code Z85010

Vitamin D3 and related compounds by ESI and APCI

Pelagia Research Library

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

Separation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column

Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples

Validation of a Reliable LC-MS/MS Method for Analysis of Simultaneously in Clinical Laboratory

Mouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.

Journal of Chemical and Pharmaceutical Research

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Comparison of Biotage Extrahera vs. Manual Sample Processing Using a Vacuum Manifold

Determination of Bath Salts (Pyrovalerone Analogs) in Biological Samples

RP-HPLC Analysis of Temozolomide in Pharmaceutical Dosage Forms

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Edgar Naegele. Abstract

Author. Introduction. Abstract

Tentu Nageswara Rao et al. / Int. Res J Pharm. App Sci., 2012; 2(4): 35-40

Title Revision n date

Agilent 1260 Infinity Analytical SFC System

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Determination of Amantadine Residues in Chicken by LCMS-8040

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

autosamplers ASI-100 and ASI-100T Autosamplers

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Agilent 7700x ICP-MS

Application Note. Author. Abstract. Introduction. Food Safety

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Fully automated sensitive determination of immunosuppressant drugs in whole blood, using high quality internal standardization

F. Al-Rimawi* Faculty of Science and Technology, Al-Quds University, P.O. Box 20002, East Jerusalem. Abstract

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

CORESTA Recommended Method No. 78

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

USP Method Transfer of Ziprasidone HCl from HPLC to UPLC

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Robust Detection of THC and Its Metabolites in Blood

[ APPLICATION NOTE ] Profiling Mono and Disaccharides in Milk and Infant Formula Using the ACQUITY Arc System and ACQUITY QDa Detector

Transcription:

Distribuido en España por: INGENIERIA ANALITICA S.L Tel: +34 902.45.6677 Fax: +34 902.46.6677 www.ingenieria-analitica.com inf@ingenieria-analitica.com

FUTURANAYSIS About Zivak UNIQUE SOLUTION FROM ONE COMPANY Zivak Technologies is an international special company providing ready to use LC-MS/MS and HPLC analysis kits in the clinical diagnostic field. The Research&Development company also supplies its own fully automated sample preparation and injection systems which enables laboratories around the globe to make efficient use of their chromatography instruments as well as their employees in a fast, accurate and cost efficient way. Index Why we analyze D2 and D3 separately? What VD-200 offering D2 and D3 analysis? What is the revolution? VD-200: High Sensitivity with Special D-Detector VD-200: Direct LIS transfer from beginning to end VD-200: Automated Sampling & Preparation from Serum tube VD-200: Fully validated system VD-200: Lower kit, maintanance and capital costs VD-200: Kit components VD-200: Validation Table 2 Zivak Technologies +90 212 210 62 14 www.zivak.com

FUTURE OF ANALYSIS Which Diseases Are Associated With Vitamin D Deficiency? Osteoporosis, Osteopenia, Osteoarthritis 17 Varieties Of Cancer (Including Breast, Prostate And Colon) Heart Disease High Blood Pressure Obesity Metabolic Syndrome And Diabetes Autoimmune Diseases Gout Disease Parkinson s Disease Depression And Seasonal Affective Disorder Alzheimer s Disease Periodontal Diseases Which Symptoms Are Associated With Vitamin D Toxicity? Hypervitaminosis D is a state of Vitamin D toxicity. Symptoms of vitamin D poisoning Include: Dehydration Vomiting Decreased Appetite İrritability Constipation Fatigue Muscle Weakness Zivak Technologies +90 212 210 62 14 www.zivak.com 3

FUTURANAYSIS Why We Analyze 25-OH Vitamin D2 and D3 Seperately? Circulating 25-Hydroxyvitamin D (25-OH-D) is widely recognized as the best indicator of vitamin D status. In blood circulation the two major vitamin d metabolites are 25-Hydroxyvitamin D3 (25-OH-D3) and 25-Hydroxyvitamin D2 (25-OH-D2). 25-OH-D3 is mainly derived from vitamin D3 produced by sunlight in the skin, while 25-OH-D2 is derived from plants in the diet. There are currently two main types of methods used routinely for measuring 25-OH- D: methods based on chromatographic separation followed by non-immunological direct detection and competitive immunoassays. Most immunoassays depend on an antibody that can detect both 25-OH-D2 and 25-OH-D3 together, but the proportion of 25-OH-D2 detection is variable. Two non-immunological methods for direct detection are currently available: high pressure liquid chromatography (HPLC) and liquid chromatography-tandem mass spectrometry (lc-ms/ ms). Chromatographic methods are able to measure 25-OH-D2 and 25-OH-D3 independently with excellent accuracy and sensitivity. On the other hand, there is many scientific studies and papers showing inaccuracy measuring total vitamin D with commercial immunoassays without separating and measuring vitamin D2 and vitamin D3 metabolites individually. It is recommended that any 25-OH-D assay in clinical laboratories should measure both 25-OH-D2 and 25-OH-D3 seperately in order to report a total 25-OH-D value. The evaluated immunoassays measure total 25-OH-D (both 25-OH-D3 and 25-OH-D2), but the cross-reaction with 25-OH-D2 and 25-OH-D3 differs from 52 to 100% in different methods. ( ( A ( ( B The scientific papers showing that variability among current commercial immunoassays measuring Total Vitamin D bring into question the benefit these assays for patients. ( ( ( ( Bland Altman difference plot for the proposed HPLC method vs the Nichols Advantage CPBA. Comparisons of the assays with patient samples containing predominantly 25(OH)D3 (A) or predominantly 25(OH)D2 (B). Clinical Chemistry 52:6 1120 1126 (2006) Home made LC-UV > Zivak Kit LC-MS/MS Participant results for 25(OH)D Total in SRM 968d Level1 (Control) as determined by immunoassay (CLIA, EIA, RIA and CLEIA) and LC (LC-MSn and LC-UV) methods. Home made LC-UV > Zivak Kit HPLC 4 Zivak Technologies +90 212 210 62 14 www.zivak.com

FUTURE OF ANALYSIS What VD-200 Offering Vitamin D2 and D3 Analysis? WALK AWAY SYSTEM HPLC and LC-MS/MS methods are accepted as Gold Method for separate analysis of 25-OH metabolites of Vitamin D. Usage of these chromatographic methods are being increased significantly on clinical laboratories recent years. The major disadvantage is the time-consuming and laborious extraction procedure that limits the number of samples that can be processed per day. Many of these laboratories cannot use their chromatography systems effectively due to these systems required qualified staff, complex sample preparation steps, high kit prices/ operation costs and no availability of walk away systems. VD-200 enables to analyze Vitamin D2/D3 samples fully automated without any human intervention- from primer sample tube. With VD-200, the low throughput in chromatography analysis will not be a problem for the laboratories any more. COST EFFECTIVE Due to large number of Vitamin D2/D3 samples, many laboratories cannot run all other LC-MS/ MS specific analysis on their LC-MS/MS systems effectively. VD-200 is especially designed the for the laboratories to provide them a cost- effective solution with a fully automated system and make customer s expensive LC-MS/MS systems free for specific tests which have to be run on LC-MS/MS system. The evaluated immunoassays measure total 25-OH-D (both 25-OH-D2 and 25-OH-D3). But the cross-reaction with 25-OH-D2 and 25-OH-D3 differs from 52 to 100% in different methods. Chromotographic gold methods are which able to measure 25-OH-D2 and 25-OH-D3 independetly with excellent accuracy and sensitivity. Literature: 1. Risteli J, Winter WE, Kleerekoper M, Risteli L. Bone and mineral metabolism. In: Tietz Textbook of Clinical Chemistry and Molecular Diagnostics. Editors: Burtis CA, Ashwood ER, Bruns DE, 5th Edition, Elsevier, St. Louis, MO, USA 2012: pp. 1733-801. 2. Lai JK, Lucas RM, Clements MS, Harrison SL, Banks E. Assessing vitamin d status: pitfalls for the unwary. Mol nutr food res 2010;54(8):1062-71. Review. 3. Vogeser M. Quantification of circulating 25-hydroxyvitamin D by liquid chromatography-tandem mass spectrometry. J steroid biochem mol biol 2010;121(3-5):565-73. 4. De La Hunty A, Wallace AM, Gibson S, Viljakainen H, Lamberg-Allardt C, Ashwell M. Uk food standards agency workshop consensus report: the choice of method for measuring 25-hydroxyvitamin D to estimate vitamin d status for the uk national diet and nutrition survey. Br J Nutr 2010;104(4):612-9. 5. Binkley N, Krueger DC, Morgan S, Wiebe D. Current status of clinical 25-hydroxyvitamin D measurement: an assessment of betweenlaboratory. Zivak Technologies +90 212 210 62 14 www.zivak.com 5

FUTURANAYSIS What is the Revolution? VD-200 High Sensitivity with Special D-Detector. Zivak Technologies offers higher sensitivity than entry level LC- MS/MS by new design Special D detector based on single wavelength UV. The limit of detection is 0.3 ng/ml quantitation for 25-OH vitamin D2 and D3 while the limit of quantitation is 0.9 ng/ml. The quantiation limit is lower than most of entry level LC-MS/MS systems which has quantitation limits variable between 1.5 5 ng/ml. LC-MS/MS Vit D3 C: 5,3 ng/ml Run Time: 1,8 min Calculated LOQ: 3,5 ng/ml Zivak Vit D3 VD-200 UHPLC Special D Detector C: 5,3 ng/ml Run Time: 3 min. Calculated LOQ: 0,9 ng/ml VD-200 is especially designed the for the laboratories to provide them a cost-effective solution with a fully automated system and make customer s expensive LC-MS/MS systems free for spesific tests which have to be run on LC-MS/MS system. Zivak Special D detector has minimum 10 times better sensitivity than any other commercially available variable wavelength UHPLC-UV detector. Commercial HPLC-UV Detector C: 10,1 ng/ml Run Time: 8 min Zivak Vit D3 VD-200 UHPL Special Detector C: 10,1 ng/ml Run Time: 3 min 6 Zivak Technologies +90 212 210 62 14 www.zivak.com

FUTURE OF ANALYSIS Direct Bidirectional LIS Data Transfer From Automated Barcode Reading To Result The VD-200 was especially designed for routine Vitamin D2/D3 testing clinical labs. VD-200 enables to analyze Vitamin D2/D3 samples fully automated without any human intervention- from primer sample tube after the technician place the samples on the sample tray. The Zivak VD-200 system automatically generates sample sequence by reading barcode from primary serum tube which barcoded by Hospital LIS system. PLACE YOUR SAMPLES AS YOU GET without align the barcodes. Due to rotational barcode reading which followed by automated sample preparation, the system is independent from placing order or position of barcode of the samples in sample tray. Also this system fulfills the requriements for the positive sample identification of CE-IVD regulations. Zivak VD-200 Walk-away UHPLC Vitamin D2-D3 Analyzer is a Plug-and-Play device and can be serviced by HPLC user. The sequence list directly generated from the barcodes of the samples. There is no possible sample mismatch from the transfer of the samples from primary serum tube to standart chromatograpy vials or well plates. Therefore, there is no possibility to mismatch of the sample identity and results which directly transferred to the LIS system of the laboratory by the VD-200 software. Automated Sampling Preparation From Serum Tube With Liquid Level Sensing All sample preparation steps for 25-OH Vitamin D2-D3 analysis made by the unique modules of VD-200 Walk Away UHPLC Analyzer. The volume of serum samples is not an issue for VD-200 system since Liquid Level Sensing capability from closed lid serum tube. Zivak VD-200 systems gives quantitative, precise and accurate Vitamin D2 and D3 results in 3 minutes. This TEST TIME includes all steps from primary serum tube to results. The processes listed below can be done by robotic arms with these unique modules; Barcode reading from serum tube. Sample transfer from serum tube. Reagent adding. Vortex mixing. Contrifuge. Injection and chromatographic run. System is not required any human intervention during all steps. By the way, 240 accurate results will be on the desk in 12 hours fully automated. Zivak Technologies +90 212 210 62 14 www.zivak.com 7

FUTURANAYSIS 240 Test Capacity / 12 Hours Standart HPLC-UV methods for Vitamin D2-D3 analysis are generally takes 6-8 minutes. This 6-8 minutes run time which does not include sample transfer from serum tube, reagent adding, protein precipitation, vortex mixing and centrifuge steps. Using HPLC-UV methods are difficult for medical laboratories and hospitals which has over 50 samples per day. For this reason, automated and high-througput chromatography methods is highly appreciated. Zivak VD-200 systems gives quantitative, precise and accurate Vitamin D2 and D3 results in 3 minutes. This TEST TIME includes all sample preparation steps from primary serum tube to results such as barcode reading, sample transfer from serum tube, reagent adding, vortex mixing, centrifuge and injection from the upper phase and analysis time. With VD-200 walk away analyzer 240 accurate results will be on the desk full automated. This state-of-art design gives robust, reliable and low carry-over results during longer column life. Lower Calibration Chromotogram from Zİvak VD-200 UHPLC Vitamin D2-D3 Analyzer with Special D-detector Excellent D2-D3 Seperation in 3 minutes. IS Analysis Date 18 April 2016-14:58:15 Barcode 22391937964 Compound Name Retention Time(min) Area (ug/l) Result 25-OH Vitamin D3 2,330 5,110 21,102 25-OH Vitamin D2 2,610 2,170 23,065 IS 2,818 9,856 --- Total Vitamin D 44,167 With the excellent resolution around 120 bar pressure and online SPE module, the VD-200 system can eliminate late peaks in 3 minutes test time. For the non-automated standart HPLC-UV systems, the late peaks must be eliminated with expensive and laborious SPE procedures during sample preparation. With the affordable and shorttime payback invesment on VD-200 Walkaway UHPLC Vitamin D2-D3 Analyzer, the expensive LC-MS/MS systems can be used for special analyses which must be run on LC-MS/MS systems. 8 Zivak Technologies +90 212 210 62 14 www.zivak.com

FUTURE OF ANALYSIS Fully Validated System With Ready to Use Vitamin D2 and D3 Analysis This system fully validated with Zivak Vitamin D2/D3 UHPLC Analysis Kit which includes all necessary reagents, calibrator and controls. Due to total validation of the VD-200 system with the analysis kit, all validation parameters including variations from automation and analysis. VALIDATION TABLE 25-OH Vitamin D3 LOD (ng/ml) 0.3 LOQ (ng/ml) 0.9 Accurary (%) 98.2 Intra-Assay Precision (%CV) 2.1 Inter-Assay Precision (%CV) 3.2 Linearity (R 2 ) 0.9995 25-OH Vitamin D3 LOD (ng/ml) 0.3 LOQ (ng/ml) 0.9 Accurary (%) 98.5 Intra-Assay Precision (%CV) 2.5 Inter-Assay Precision (%CV) 3.6 Linearity (R 2 ) 0.9990 With the excellent resolution around 120 bar pressure and online SPE module, the VD-200 system can eliminate late peaks in 3 minutes test time. Lower Kit, Maintanance And Capital Costs The aim of Zivak Technologies is to give opportunity laboratories around the globe to make efficient use of their chromatography instruments as well as their employees in a fast, accurate and cost efficient way. The immunoassay systems seems chepaer way of the analysis of vitamin D status. There is many scientific studies and papers showing inaccuracy measuring total vitamin d with commercial immunoassays without separating and measuring vitamin D2 and vitamin D3 metabolites individually. It is recommended that any 25-OH-D assay in clinical laboratories should measure both 25-OH-D2 and 25-OH-D3 separately in order to report a total 25-OH-D value. Zivak VD-200 walk-away UHPLC vitamin D2-D3 analyzer gives the chance customers to analyze 25-OH-D2 and 25-OH-D3 separately with the cost which around immunoassay systems. Zivak VD-200 walk-away UHPLC vitamin D2-D3 analyzer has better sensitivity if compared entry-middle level of LC-MS/MS systems. But the maintanence cost of VD-200 system is significantly lower than any LC-MS/MS system. As known, lc-ms/ms systems needs many environmental supplies e.g. Nitrogen generator, argon gas, turbomolecular pumps, rough vacuum pumps and ESI/APCI needles. These parts are has limited lifetime and has to be serviced by the experts. Most of medical laboratories their LC-MS/MS systems occupied with vitamin D2-D3 analysis since their high number vitamin D2-D3 samples. Zivak Technologies +90 212 210 62 14 www.zivak.com 9

FUTURANAYSIS KIT Zivak ready to use 25-OH Vitamin D2-D3 UHPLC Analysis kit is used with VD-200 Walk away UHPLC Analyzer. 25-hydroxy metabolites of Vitamin D2 and D3 are extracted from human serum samples using an organic extraction solution after deproteinisation step. Separation was made with an isocratic elution on Zivak 25-OH Vitamin D HPLC column and measured by special D-detector which specially designed for 25-OH Vitamin D2-D3 UHPLC Analysis. AutoMass Software automatically checks the results with low and high levels of the controls for the intra-day and inter-day precision. VALIDATION TABLE ZV-4027-0200-10 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analysis Kit ZV-4027-05S1-10 1 x 2 ml Serum Calibrator Level 1, lyophilised ZV-4027-05K1-10 1 x 2 ml Serum Control Level 1, lyophilised Materials Supplied ZV-4027-05K2-10 1 x 2 ml Serum Control Level 2, lyophilised ZV-4027-02R1-10 3 x 37 ml Reagent 1, Contains aqueous buffer ZV-4027-02R2-10 2 x 40 ml Reagent 2, Contains internal standard ZV-4027-02R3-10 1 x 12 ml Reagent 3, Contains dilution buffer ZV-4027-02MP-10 1 x 0,75 L Mobile Phase, Contains organic solvent ZV-4027-02MT-10 1 x 0,75 L SPE buffer, Contains organic solvent ZV-4027-02WB-10 1 x 0,5 L Washing Solution, Contains organic solvent ZV-4027-02KK-10_REV00 1 x 1 pc User Guide ZV-4027-02S2-10 1 X 2 ML Serum Calibrator Level 2, lyophilised (Optional) Materials Not Supplied with ZV-4027-02S3-10 1 X 2 ML Serum Calibrator Level 3, lyophilised (Optional) ZV-4027-02TM-10 1 X 2 ML Test Mix Solution (Optional) ZS-9003-0100-00 2X100 PCS 1.8 ml glass autosampler vial ZS-9004-0100-00 2X100 PCS 1.8 ml glass autosampler vial caps pre-slit ZV-4027-02C1-10 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Analytical Column ZV-4027-02C2-10 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Trap Column Housing ZV-4027-CSPE-10 25-Hydroxyvitamin D2-D3 Serum VD-200 UHPLC Trap Column Cartridge 10 Zivak Technologies +90 212 210 62 14 www.zivak.com

FUTURE OF ANALYSIS TECHNICAL SPECIFICATIONS VD-200 Specifications GENERAL Power Requirements: - Operating Voltage: 220-230V AC - Operating Frequency: 50 60 Hz - Operating Current: 3A Max Dimensions(W x D x H): 1020mm x 825mm x 676mm Working Temperature: 10 40 o C Storage Temperature: -20 70 o C Humidity: %30 80 RH Sound Level: < 60dB @1m SAMPLING & INJECTION Sample Capacity: 108 (13 mm Diameter Serum Tube - 5 ml volume) Loop Volume: 100 ul Injection cycle time: 3 minutes Syringe volume: 250 ul for injection, 10 ml for reagents Wash Solvent: External wash solvent bottle. Wetted parts in flow path: Metal tubing stainless steel number, PTFE, teflon, glass Liquid Detection: clld (Capacitive Liquid Level Detection) Switching Time of Valves: Less than 1 second Column Oven: Constant Temperature (35 C) Valves : 2 x 6-port Injection & Switching valves DETECTOR Special D-detector with 0.9 ng/ml LOQ for Vitamin D3 & D2 Cell Length: 70 mm Working Temperature: 20 30 o C Fixed Wavelength: 264 nm ANALYTICAL PERFORMANCE Injection Mode: Full-Loop Injection Reproducibility: Full loop injection < %0.3RSD Carry Over: - Less than %0.05 while standard wash - Less than %0.01 while extra wash PROGRAMMING User Interface: Automass Chromatography Software V2 for VD-200 Injection Mode: Full-Loop Injection volume: 100 ul Wash: Needle wash - Wash inside and outside of the needle - Wash between injections - Wash between vials COMMUNICATION CIB to PC communication with CAT5 ethernet cable PUMPS 2 x UHPLC Pumps Flow Rates: 0.001 5.0 ml/min Pressure: 18000 psi Maximum Pressure Accuracy: ± 2% of full scale pressure Pressure Zero Offset: ± 2psi Flow Accuracy: ± 2% for a flow rate of 0.20 ml/min and above, with 80:20 Water/IPA @ 1000psi Flow Precision: 0.5% RSD Working Temperature: 10 30 o C Humidity: %20 90 RH Zivak Technologies +90 212 210 62 14 www.zivak.com 11

FUTURANAYSIS FUTURE OF ANALYSIS www.zivak.com Distribuido en España por: INGENIERIA ANALITICA S.L Tel: +34 902.45.6677 Fax: +34 902.46.6677 www.ingenieria-analitica.com inf@ingenieria-analitica.com 12 Zivak Technologies +90 212 210 62 14 www.zivak.com ZIVAK TECHNOLOGIES Eski Besiktas Cad. No:44, 34400 ISTANBUL / TURKEY +90 212 210 62 15 +90 212 210 62 14 info@zivak.comw ww.zivak.com