instadose dosimeters Dosimetry Services Division

Similar documents
radiation monitoring programs Tailored to your needs

REPORT: MEASUREMENT OF X-RAY DOSE SECURITY CHECK BERGEN AIRPORT FLESLAND (AVINOR)

Reports Overview. dosimetry services A Mirion Technologies Division. Featuring:

University of Maryland Baltimore. Radiation Safety Standard Operating Procedure

When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter

MANUAL

Title: Code of Practice for users of personal dosimeters 1, 2

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C

User Manual second language

COA Innovation Award: My EAP Case Study

Data Management System (DMS) User Guide

Let s get started with the OneTouch Reveal web app

Introduction. Accessing EHS Assistant

DPV. Ramona Ranz, Andreas Hungele, Prof. Reinhard Holl

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use

Keysight Infoline Services

Ava Fertility Tracker User Manual Version 5.0. Not for contraceptive use.

SleepImage Website Instructions for Use

Sleep Apnea Therapy Software Clinician Manual

AIR FORCE SPECIALTY CODE 4B051 BIOENVIRONMENTAL ENGINEERING

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

NRT Contractor Safety Management System Portal User Guide Registering your company and purchasing new cards

SHORETEL APPLICATION NOTE

Now offering a Real-time dose measurement system featuring RaySafe i3. Powered by

2012 Nutrition Care Manual Update Webinar for DCE DPG

Kofax VRS. Installation Guide

Dosimeter Setting Device

RaySafe i3. Visualize your radiation exposure in real time.

Plug-and-play goes online

IONISING RADIATIONS REGULATIONS 2017 REGULATIONS 5, 6, AND 7. NOTIFICATION, REGISTRATION AND CONSENT

User s Manual. Model No. NTMPADS15.0 Model No. NTMPAD16.0

Over view. Wrist Placement.

Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

Ava Fertility Tracker User Manual Version 4.0. Not for contraceptive use.

How-To Evaluate a Veterinary Digital Radiography System A SPECIAL REPORT

Now offering a subscription based real-time dose measurement system featuring RaySafe i3. Powered by

1 Patient information

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

Cyrus soundkey User Instructions Contents

Professional body composition analysis: BODYSTAT I500. Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

Software Version 2.0. User s Guide

Dexcom CLARITY User Guide For Clinics

Cyrus soundkey User Instructions Contents

Instructor Guide to EHR Go

Diabetes Management App. Instruction Manual

Radiation Protection Program Update: The Details. July 2010

THIM User Manual 1.0 GETTING STARTED 3 WHAT YOU LL FIND IN THE BOX 3

Nuclear power plants, hospitals, medical facilities, homeland security, and other organizations

RaySafe i3 INSTALLATION & SERVICE MANUAL

Trends in Occupational Exposure in Malaysia

OKLAHOMA STATE UNIVERSITY X-RAY MACHINE PROGRAM AND PI HANDBOOK For easy navigation, please use Adobe s bookmark feature.

Cortex Gateway 2.0. Administrator Guide. September Document Version C

A Novel Concept and Technique for Individual Monitoring for Photon, Beta and Neutron Radiation

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

Sanako Lab 100 STS USER GUIDE

An Overview of ProviderConnect. For Applied Behavior Analysis (ABA) Providers

Complex just became comfortable.

Nokia BPM. Blood Pressure - Heart rate Measurement. Installation and Operating Instructions EN - 1. Nokia BPM. v2.0 January 2018

Elemental Kinection. Requirements. 2 May Version Texas Christian University, Computer Science Department

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

Overview, page 1 Shortcut Keys for Cisco Unity Connection Administration, page 1 Other Unity Connection Features, page 4

VIDA / LIFE: LA CIENCIA DE LA BIOLOGIA / THE SCIENCE OF BIOLOGY (SPANISH EDITION) BY WILLIAM H. PURVES, DAVID SADAVA, H.

CNCA 06, General Service District 15 WEBSITE GUIDELINES P.O. Box 3504, Eureka, Ca 95502

Sleep Apnea Therapy Software User Manual

Flu season. Making the most of online appointments. August 2018

6. If I already own another brand Videophone, can I use it with the ACN Digital Phone Service? No.

User Manual RECHARGEABLE KIT. Includes: 1 PLUS+ rechargeable pack 2 PLUS+ batteries 1 wall charger 1 USB cable 3 Classic Tobacco flavor tanks

INSTRUMENTS. Personal alarm dosimeter 120 Survey meters 122 Beta secondary standard 123

a. If dosimeters should be issued; b. What type(s) will be used and; c. The frequency that dosimeters will be exchanged

User Manual. RaySafe i2 dose viewer

Data Management System (DMS) User Guide

User Manual CentrePoint Data Hub

UpToDate Anywhere. Registration Guide. This Registration Guide outlines how to: Register for a free account Access UpToDate Stay current

MONITORING OF OCCUPATIONAL EXPOSURE AT NUCLEAR FACILITIES

Unitron Remote Plus app

RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

HANSATON stream remote App User Guide. HANSATON stream remote App User Guide

Fitting System Instructions for Use

How to Use the myhearing App on Apple/iOS devices

mehealth for ADHD Parent Manual

Ascribe Rx Online Resource Center User Guide

Ava Fertility Tracker User Manual Version 2.0. Not for contraceptive use.

BLOODPRESSURE & PULSE App for iphone, ipad and ipod USER GUIDE. App Version 2.2

Symantec ESM Agent for IBM AS/400 Installation Guide. Version: 6.5

ShoreTel Trunk Side Integration Guide

For more comprehensive information, please refer to the t:connect Application User Guide available online at: Getting Started Guide.

Reader and Sensor Demo Kit. Quick Start Guide

HeroTracker Sensor for Diskus Instruction Manual

Lionbridge Connector for Hybris. User Guide

Anchor p! All Healthcare Professionals on Deck. April 11-13, Tennessee MGMA 2018 Spring Conference. Park Vista Hotel, Gatlinburg TENNESSEE

Connevans.info. DeafEquipment.co.uk. This product may be purchased from Connevans Limited secure online store at

Getting Started Guide

Wireless Blood Pressure Monitor

Agile Product Lifecycle Management for Process

Dosimeter Setting Device System NRZ

Atlantis. Atlantis Viewer (app) User guide

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

Transcription:

instadose dosimeters Dosimetry Services Division

instadose Dosimeter Instant. Precise. Portable. OVERVIEW The instadose dosimeter brings radiation monitoring into the digital age. Smaller than a flash drive, this rugged dosimeter provides immediate dose readings by using any internet enabled computer. This easy-to-use dosimeter is the only accredited USB-compatible dosimeter that enables users to measure radiation dose at anytime, as often as they wish from an internet enabled computer. Based upon proprietary direct ion storage technology, the instadose dosimeter includes access to each user s historical and current exposure readings. There is no need to send dosimeters to a processing center, simplifying administration and reducing costs. The instadose website is rendered in several languages including English, French, Japanese, and Spanish KEY BENEFITS Unlimited dose reads Increased compliance Online badge reassignments Immediate online reporting Elimination of collecting badges for processing

PERFORM DOSE READS AT ANYTIME How the badge works This breakthrough technology provides radiation workers with a precise measurement of radiation dose and includes accurate long-term exposure tracking. Each dosimeter has a unique serial number for identification. Readings via a computer are enabled by a USB compatible detector. Before use, each dosimeter must be registered and initialized online at: www.instadose.com. During the registration process, an application must be installed on the each computer that will be used to perform dose readings. This application only transfers dose data to Mirion s secure servers when reads are performed. Perform a reading To obtain a dose reading log-in to www.instadose.com, connect the instadose dosimeter to the USB port and click Read Device on the main screen. The stored accumulated dose is processed through a proprietary algorithm. This fully automated transfer of data minimizes the chance of human error and misidentification. Once complete, the current dose is displayed on the screen. Dose reads are reviewed and if necessary analyzed by Mirion s technical staff. The instadose dosimeter can be read up to a cumulative dose of 12 rem, if an exposure exceeds this limit the dosimeter will need to be sent in for processing and reporting. SECURE WEB-BASED ACCOUNT MANAGEMENT Our streamlined, secure Account Management Program (AMP) makes account administration a breeze. From account administration to managing individual wearers and dosimeters, AMP provides real time access to account details, assignments, reports, and all pertinent account information. Features available with AMP include: Dosimeter registration Management of accounts, dosimeters, locations and users

AMP roles and responsibilities Access to areas of AMP are determined by role assignment, this is very important to keep in mind when creating or editing users within your account. The roles are defined below: Administrator: Full access to all functions on the site. From placing orders, performing readings for badges, running reports, creating/deactivating locations and users, to registering and initializing badges. Location Admin: Access to functions on the site are limited to the assigned location. A location admin can place orders, perform readings, run reports, edit or add users, and register and initialize badges for that location. Group Admin: Access to functions on the site are limited to the assigned group within a location. A group admin can place orders, perform readings, run reports, edit or add users, register and initialize badges for the group under the location. A Group Admin can not edit the location. Wearer: A Wearer can only perform readings for badges assigned to them. Reports will only contain their data. Wearers can update their e-mail, phone and password. REPORTS You have access to a variety of on-demand reports. Reports can be custom generated by selecting a specific person, group or location, and date. Once the selection process is complete the report will open in a new window. Reports can be printed or downloaded into a variety of formats. Available reports include: Radiation Exposure Summary Report Form 5 Dosimeters Not Read History Detail Report

Technical Specifications Description Badge Type Accreditations/Approvals/Licenses Minimum Reportable Dose Lower Limit of Detection Useful Dose Range Energy Response instadose Dosimeter Direct Ion Storage device 31= instadose 1 In the United States under NVLAP (lab code: 100555-0) in the UK under HSE (DS 49/2010) and various other country accreditations/ approvals 3 mrem (0.03 msv) 1 mrem (0.01 msv) upon request 1 mrem (0.01 msv) 1 mrem - 500 rem* (0.01 msv - 5 Sv) Photon 5 kev - 6 MeV * the instadose device can be read at your facility up to a cumulative dose of 12 rem (0.12 Sv), for exposures exceeding this limit or used outside of occupational monitoring the device would need to be sent to Mirion Technologies Dosimetry Services Division (DSD) for processing /reporting, additional fees may apply. Copyright 2013, All rights reserved. For trademark and registered trademark information. Specifications are subject to occasional change, please ask for confirmation of the information given in this publication. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation How to open a badge

2652 McGaw Avenue Irvine, CA 92614 USA U.S./Canada: +1.800.251.3331 U.K.: 0170.629.9329 Worldwide: +1.949.419.1000 dsd-support@mirion.com Copyright (c) 2014 Mirion Technologies, Inc. or its affiliates. All rights reserved. Mirion, the Mirion logo, and other trade names of Mirion products listed herein are registered trademarks or trademarks of Mirion Technologies, Inc. or its affiliates in the United States and other countries. Third party trademarks mentioned are the property of their respective owners. LIT4386_5v1