radiation monitoring programs Tailored to your needs

Similar documents
instadose dosimeters Dosimetry Services Division

Reports Overview. dosimetry services A Mirion Technologies Division. Featuring:

REPORT: MEASUREMENT OF X-RAY DOSE SECURITY CHECK BERGEN AIRPORT FLESLAND (AVINOR)

Radiologic Units: What You Need to Know

RADIATION MONITORING DEVICES R A D I A T I O N P R O T E C T I O N & B I O L O G Y - R H O D E S

a. If dosimeters should be issued; b. What type(s) will be used and; c. The frequency that dosimeters will be exchanged

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

When worker safety is mission critical. Thermo Scientific EPD TruDose Electronic Dosimeter

Sandy Perle. Radiation Litigation: an Expert Witness Perspective

RadPro International GmbH i

Development of the Nation-Wide Dosimetric Monitoring Network in Ukraine

Radiation Health Protection Manual

RADIATION SAFETY REFRESHER TRAINING FOR AUGUSTA UNIVERSITY USERS OF RADIOACTIVE MATERIAL

University of Maryland Baltimore. Radiation Safety Standard Operating Procedure

Radiation Protection Program Update: The Details. July 2010

Section 7 ALARA Program

U.S. DEPARTMENT OF ENERGY LABORATORY ACCREDITATION PROGRAM (DOELAP) FOR PERSONNEL DOSIMETRY SYSTEMS

A Novel Concept and Technique for Individual Monitoring for Photon, Beta and Neutron Radiation

Phonak Fast Facts. Audéo B-Direct

The Status and Challenges of External Personal Dosimetry

A NEW USER-FRIENDLY EXTREMITY DOSIMETRY SYSTEM DESIGN, COMPARISON, AND TESTING

Approval of Dosimetry Services in Ireland Guidelines for Applicants

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C

MONITORING OF OCCUPATIONAL EXPOSURE AT NUCLEAR FACILITIES

Pmasonic Dosimetry System Peformance Testing and Results at Nuclear Accident Dose Levels

3/26/2017. Personal Dosimetry Monitoring and Dose Measurements. Agenda. Dosimetric Terms and Definitions Dose Limits External Dosimetry

Radiation Safety Guide. Analytical X-Ray Equipment

AIR FORCE SPECIALTY CODE 4B051 BIOENVIRONMENTAL ENGINEERING

Now offering a Real-time dose measurement system featuring RaySafe i3. Powered by

Personal Dosimetry. Radiation Protection Section Department of Medical Physics Colchester Hospital University NHS Foundation Trust

User Manual. RaySafe i2 dose viewer

Chem 481 Lecture Material 3/11/09

Assessment of radiological hazard and occupational dose to the lens of the eye at the Bruce Power Nuclear Generating Station

RaySafe i3. Visualize your radiation exposure in real time.

Now offering a subscription based real-time dose measurement system featuring RaySafe i3. Powered by

Please find enclosed Dosimetry Service Licence No which replaces Dosimetry Service Licence No

HANSATON stream remote App User Guide. HANSATON stream remote App User Guide

Connecting the STIM ontrack App to your Bone Growth Therapy Device

MANUAL

Professional body composition analysis: BODYSTAT I500. Touch Screen THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

User Manual second language

How to Use the myhearing App on Apple/iOS devices

Dosimeter Setting Device

Data Management System (DMS) User Guide

THIM User Manual 1.0 GETTING STARTED 3 WHAT YOU LL FIND IN THE BOX 3

PERSONNEL MONITORING AND DOSIMETRY POLICIES

Radiation Monitoring Instruments

Connected to my Health

Boehringer Ingelheim BioXcellence. Producing Value. Global Contract Manufacturing Excellence

Unitron Remote Plus app

ECG Check Wireless 1- Lead Cardiac Monitor. Rx Use

Trends in Occupational Exposure in Malaysia

RELIANT HOLDINGS LTD AND ITS AFFILIATES Safety Management System. Preparation: Safety Mgr Authority: CEO Issuing Dept: Safety Page: Page 1 of 5

Implementation Guide for the DoseControl Dosimetry System

Title: Code of Practice for users of personal dosimeters 1, 2

Eliminate the Most Common Challenges in Audiometric Testing A Case for Tablet Audiometry in Occupational Hearing Conservation

For Electric Personal Dosimete Dose-i

At Mio, we believe that the single biggest change you can make to your performance is monitoring your heart. That is why Mio develops innovative,

Radiation Safety Bone Densitometer

Accreditation of Dosimetry Services

Personal Dosimetry in Sweden - Challenges and Developments

Ava Fertility Tracker User Manual Version 5.0. Not for contraceptive use.

10 Years of Safe Operation at the Canadian Light Source A Radiation Safety Perspective

REVISED CODEX GENERAL STANDARD FOR IRRADIATED FOODS CODEX STAN , REV

Align Gluco-Monitoring System (BG1) Quick Start Guide

Variation of Occupational Doses among Subspecialties in Diagnostic Radiology. A.N. Al-Haj, C.S. Lagarde, A.M. Lobriguito

OCCUPATIONAL EXPOSURE IN CANDU NUCLEAR POWER PLANT: INDIVIDUAL DOSIMETRY PROGRAM AT CERNAVODA NPP

CENTREPOINT DATA HUB REAL-WORLD INSIGHTS IN NEAR REAL TIME

RaySafe i3 INSTALLATION & SERVICE MANUAL

Share/Follow. User Guide. A feature of Dexcom G5 Mobile CGM System

myphonak app User Guide

Professional body composition analysis: BODYSTAT I500 THE SCIENCE BEHIND CLINICAL BODY ASSESSMENT.

ENJOYING YOUR NEW E-CIGARETTE

Aer ODE B3-20. Database System for GEX B3 Dosimetry. Aérial. Optical Dosimetry Equipment. (gamma and/or electron beam versions)

SELECTIC REMOTE APP. User Guide

INSTRUMENTS. Personal alarm dosimeter 120 Survey meters 122 Beta secondary standard 123

HEARING CONSERVATION PROCEDURE

Dosimeter Setting Device System NRZ

Y Physics Radiation Measurements and Monitoring

SUMMARY OF PERSONAL DOSIMETRY PRACTICIES IN RCA MEMBER COUNTRIES

Monitoring Occupational Exposure to Ionizing Radiation

10/21/2013. Pakistan A quick primer. Pakistan. Pakistan. Pakistan

Cleveland Clinic Home Monitoring Pilot

Versana Premier. Care with Confidence. gehealthcare.com

Lionbridge Connector for Hybris. User Guide


Align Gluco-Monitoring System (BG1) Quick Start Guide

HEINE Dermatoscopes. Magnification Magnification x 40x* (digital)

Staff Exposure Monitoring in Interventional Radiology

A Novel Dosimetry System for Military Use in Response of Nuclear Emergencies

BC380. The New Standard in Body Composition Analysis BODY COMPOSITION ANALYZER

Smart Connected Hearing NEXT GENERATION HEARING PROTECTION

GE Healthcare 9900 Innovation Drive Wauwatosa, WI U.S.A.

Everything you need to stay connected

Radiation Safety Manual

Ava Fertility Tracker User Manual Version 4.0. Not for contraceptive use.

Development of Electron Beam and X Ray Applications for Food Irradiation

Graft Delivery Devices

Thrive Hearing Control App User Guide for Apple. Congratulations on your journey to better hearing

BRITE R450. LightTrak Sensor Time/Date. Goal Progress Bar Activity Value Activity Type Notification Alert. Quick Start Guide

Transcription:

radiation monitoring programs Tailored to your needs Dosimetry Services Division

OVERVIEW Mirion Technologies is comprised of five divisions delivering products, services, and solutions in the world of radiation detection and protection. From our 13 operating facilities across North America, Europe, and Asia we combine state of the art technology with exceptional service. Mirion Technologies Dosimetry Services Division (DSD) is the first name in dosimetry innovation. With over 44 years of dosimetry experience, we provide the most technologically advanced dosimeters on the market. Our line of dosimeters includes Genesis TLDs (thermoluminescent dosimeter), OSL (optically stimulated luminescence) and the revolutionary instadose line, exclusively developed by Mirion. Serving the needs of enterprise customers where there may be hundreds of employees, often in various locations, requires specific expertise and specialized program management. Our monitoring services are tailored to meet your requirements. We operate from our state-of-the-art facility in California, we continue to invest in the exploration of new technologies and enhance our processing capabilities through lean manufacturing. We have an unparalleled commitment to customer satisfaction from our customer and technical support teams to our robust web-based capabilities; our priority is You.

WEB BASED ACCOUNT MAINTENANCE PROGRAMS Managing dosimeters in your facility should not be time consuming. Our comprehensive, streamlined web-based account management capabilities make reporting and account maintenance a breeze. Our secure systems give you the ability to manage your account on your time. AMP SECURE WEB-BASED ACCOUNT MANAGEMENT PROGRAMS Account administrators can manage all the elements of a radiation monitoring program with AMP (Account Management Program). From managing individual wearers, devices, and locations, AMP provides real-time access to account details, dosimeter assignments, reports, and pertinent account information. AMP has multiple security levels, restricting users within an account from viewing other wearers data or changing account information. If you have instadose dosimeters within your account, additional functionality is available including: Performing real time readings and badge assignments for instadose 1 dosimeters. Setting automatic calendar dose reads, and badge assignments for instadose+ dosimeter models. Features: Customize your account to receive email notifications of available reports, or high dose notifications. Set authority levels for other administrators within your account to access certain features. Run queries and review dose histories. Manage badge assignments, individual wearer information, and locations. View available radiation reports.

MY DOSE RECORD (MDR) My Dose Record (MDR) provides a secure, easy and convenient way for your employees to access their dose history through our secure website. MDR provides you with more time to concentrate on other tasks instead of the time-consuming effort of distributing reports to each department. MDR gives real-time access to dose history in an easy-to-read-format. Whether one dosimeter or several are worn, the history for each is listed separately. CUSTOMER SUPPORT Mirion is committed as a company to customer satisfaction. We go beyond solving problems to help you find the best way to meet your radiation monitoring program needs. Our Customer Care department is staffed with highly trained individuals to provide you with outstanding support. CONSULTATION SERVICES Rely on us to assist in the planning and implementation of your radiation monitoring program. Our expert technical group is staffed with highly qualified health physics and radiation dosimetry experts. We can assist with the development of your inhouse radiation monitoring programs or provide you with tailored services such as training manuals, algorithms, or turn key monitoring programs.

INSTADOSE DOSIMETERS The instadose line of dosimeters is transforming the way facilities manage their radiation monitoring programs. Now immediate dose reads can be captured by smart phones, tablets, or internet enabled computers. With instadose dosimeters in your facility you can: Reduce the cost associated with running your monitoring program. Eliminate the collection of badges to be returned for processing. Access reports online eliminating the need to archive and distribute results. Increase compliance. Reassign badges online at anytime. Manage every aspect of your monitoring program with our secure web-based program.

INSTADOSE DOSIMETER With the first generation instadose dosimeter dose reads are performed immediately from any computer with internet access by connecting the instadose dosimeter to the USB port and logging on to our secure web-based program. Benefits: Unlimited dose readings performed online No battery replacements or calibration No special software required Technical Specifications instadose Dosimeter Description Badge Type 31= instadose 1.0 Accreditations/Approvals/Licenses Direct Ion Storage device with USB connector NVLAP (Code: 100555-0) HSE DS 49/2010 (United Kingdom) Various other country accreditations/ approvals Minimum Reportable Dose Useful Dose Range Energy Response 3 mrem (0.03 msv) 1 mrem (0.01 msv) upon request 1 mrem - 500 rem* (0.01 msv - 5 Sv) Photon 5 kev - 6 MeV *the instadose dosimeter can be read at your facility up to a cumulative dose of 12 rem (0.12 Sv), for exposures exceeding this limit or used outside of occupational monitoring the device would need to be sent to Mirion Technologies Dosimetry Services Division for processing /reporting, additional fees may apply.

INSTADOSE+ DOSIMETER MODEL: The instadose+ dosimeter utilize Bluetooth Low Energy (BLE) Technology to wirelessly transmit real-time dose data to your smart devices, or to the instadose line of communication products; instalink-usb or instalink hotspot stations. Automatic dose reads are set using a configurable calendar. Manual reads are performed by pressing the button located on the back of the badge. Improve the management of your dosimetry program by: Eliminating the badge collection process Increasing compliance Tracking and controlling dose for high risk employees Reading intervals set for dose trending Alerting e-mails sent when a dose exceeds a user specified level COMMUNICATION METHODS The following communication devices are used to capture reads from instadose+ badges that are within range: Smart devices with BLE technology with the instadose app installed PCs with an instalink-usb connected instalink Hotspot Stations Technical Specifications instadose + Description Badge Type 32= instadose + Direct Ion Storage device with BLE Technology Accreditations/Approvals/Licenses NVLAP (Code: 100555-0) Minimum Reportable Dose 3 mrem (0.03 msv) Useful Dose Range 1 mrem - 500 rem* (0.01 msv - 5 Sv) Energy Response Photon 5 kev - 6 MeV

DOSIMETER SELECTIONS Mirion also offers the traditional mail in dosimetry service with exchange periods from monthly, quarterly, or semi annual. The most requested mail in dosimeters include our Genesis Ultra TLD, MeasuRings, and APex OSL. GENESIS ULTRA TLD The Genesis Ultra TLDs respond accurately to beta, gamma, X-ray and neutron radiation. The response of each element is corrected by the application of its own unique element correction factor and allows for the reporting of deep, lens of eye and shallow doses. MEASURING Ring dosimeters provide accurate readings for the radiation received to extremities. Our MeasuRing is bar coded and consists of a lithium fluoride element in a single-piece construction. The MeasuRing can be immersed and cold sterilized. APEX OSL The APex dosimeters slim profile and light weight (2.8 x 1.6 ) makes the badge easy to wear on the body or extremities. Even when exposed to extreme temperatures or moisture the dosimeter will provide accurate dose readings. As with other OSL technologies, APex can be re-read multiple times, enabling re-evaluation into unusual exposures. Specifications Genesis Ultra TLD Dosimeter MeasuRing Dosimeter APex OSL Dosimeter Description Badge Type 4 element TLD (3 7 LiF:Mg, Cu, P [TLD700H] and 1 6 LiF:Mg, Cu, P [TLD600H]) 36= Genesis Ultra TLDMCP 35= Genesis Ultra TLDMCP w/ CR39 Single chip of n LiF:Mg, Cu, P powder chipstrate (TLD100H) 19= MeasuRing 30 = APex OSL 2 element beryllium oxide (BeO) Accreditations/ Approvals/Licenses NVLAP (Code: 100555-0) HSE (United Kingdom) DoELAP*** NVLAP (Code: 100555-0) HSE (United Kingdom) DoELAP*** CNSC (Canada) NVLAP (Code: 100555-0) Holder Type DA, DB, DL, DW MS= Small size 5.5 (16.1mm)* MM= Medium size 8 (18.1mm)* ML= Large size 11 (20.6mm)* MX= XLarge size 14.5 (23.4mm)* BP= Blister pack Minimum Reportable Dose 1 mrem (0.01 msv) 20 mrem (0.20 msv) 5 mrem (0.05 msv) Useful Dose Range 1 mrem - 1000 rad (0.01 msv - 10 Gy) 20 mrem - 1000 rem(0.20 msv - 10 Sv) 5 mrem - 1000 rem (0.05 msv - 10 Sv) Energy Response Beta 0.251 MeV - 5 MeV Photon 5 kev - 6 MeV Neutron (TLD): Thermal - 6 MeV Neutron (CR39): 200 kev - 6 MeV ** Beta Photon 0.251 MeV - 5 MeV 20 kev - 6 MeV Beta Photon 0.565 MeV 5 MeV 12 kev - 7 MeV

DOSIMETRY SERVICES YOU CAN TRUST

2652 McGaw Avenue Irvine, CA 92614 USA U.S./Canada: +1.800.251.3331 U.K.: 0170.629.9329 Worldwide: +1.949.419.1000 dsd-support@mirion.com Copyright (c) 2014 Mirion Technologies, Inc. or its affiliates. All rights reserved. Mirion, the Mirion logo, and other trade names of Mirion products listed herein are registered trademarks or trademarks of Mirion Technologies, Inc. or its affiliates in the United States and other countries. Third party trademarks mentioned are the property of their respective owners. LIT4262_8_US