Active, yet simple deployment, now with a curved approach. SUTUREFIX All-Suture Anchor

Similar documents
Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

Improved access, ultra-low displacement 1 and the highest fixation strength 1. Q-FIX All-Suture Anchor

The next generation in all suture implant technology. Q-FIX All-Suture Implants

Arthroscopic Shoulder Instability Repair Using the Curved Guide and Anchor Delivery System

SureLock All-Suture Anchor System

Y-Knot Flex NEW. All-Suture Anchor System

JuggerKnot and JuggerKnotless Soft Anchor. All-Inclusive Brochure

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

JuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair

HIP ARTHROSCOPY BROCHURE

Hard to reach areas require specific solutions

Chart a course for meniscal preservation

ToggleLoc. Fixation Device. Surgical Technique. Femoral Fixation for ACL Reconstruction SPORTS MEDICINE. Surgical Protocol by Mark Gittins, D.O.

Hip Arthroscopy. All Inclusive Brochure

Conventus CAGE PH Surgical Techniques

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair

Arthroscopic and Mini-Open Rotator Cuff Repair

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant

Coracoid Bone Conserving Acromioclavicular Joint Reconstruction using ToggleLoc Device with ZipLoop Technology

A sequenced approach to flush graft placement. GLENOID BONE LOSS SYSTEM Procedural Solution

Subpectoral Biceps Tenodesis using Cortical Buttons Surgical Technique

ROTATOR CUFF REPAIR WITH STATAK SUTURE ANCHORS

ComposiTCP Anchor with BroadBand Tape

Comprehensive Product Offerings for Your Rotator Cuff Repair

Arthroscopic and Mini-Open Rotator Cuff Repair. using JuggerKnot Soft Anchor 2.9 mm with ALLthread Knotless PEEK-Optima Anchor Surgical Technique

Femoral Fixation for ACL Reconstruction. Surgical Protocol by Mark Gittins, D.O.

Surgical Technique. Proximal Humerus Locking Plate

ToggleLoc Inline Device

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

GENERAL TECHNIQUE GUIDE

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

BICEPTOR Tenodesis System

BTB ACL Reconstruction with the ToggleLoc Fixation Device with ZipLoop Technology. Surgical Technique by James R. Andrews, M.D.

MULTIFIX S Knotless Implants

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

ENDOBUTTON Family of Fixation Devices. Often imitated, never equaled, the gold standard for femoral fixation.

Lateral Ankle Ligamentous Instability. Surgical Technique by Jeffrey Nacht, M.D.

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

The first cannulated retrograde drill providing precision and control from a guide wire. ACUFEX TRUNAV Retrograde Drill

TABLE OF CONTENTS. 2 (8144 Rev 2)

Medial Portal ACL Reconstruction

Technique For SLAP Repair in 2016

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

Comprehensive Product Offerings for Your Rotator Cuff Repair

Shoulder Restoration System

Surgical Technique International Version. Clavicle Locking Plate

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant

ENDOBUTTON Fixation Device

Twin Tail TightRope System

28 Surgical Technique

HEALIX TRANSTEND Implant System: A percutaneous solution for partial tears of the rotator cuff. Partial tear. Complete solution.

Technique Guide. VersiTomic. ReelX STT Double-Row Achilles G-Lok. J. Martin Leland III, M.D. J. Martin Leland III, M.D. Proximal Biceps Tenodesis

JuggerKnot Soft Anchor 1.0 mm Mini. Scapholunate Ligament Repair/Reconstruction. Brochure and Surgical Technique

Knee spanning solutions

Shoulder Arthroscopy Lab Manual

Surgical Technique. Anterolateral and Medial Distal Tibia Locking Plates

ACL Reconstruction Single Tibial Tunnel Double Bundle

VersiTomic Flexible Reaming System

CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique

JuggerKnot Soft Anchor 1.0 mm Mini

Precautionary Statement ( )

Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique

MCL Reconstruction Surgical Protocol by Tarek Fahl, M.D.

The AperFix II System

Flexibility In Action. ACL Instrumentation

with ACL Reconstruction Single Tibial Tunnel Double Bundle Surgical Protocol by Eric McCarty, M.D.

Dual Row Rotator Cuff Repair using the CHIA PERCPASSER

Surgical Technique. Clavicle Locking Plate

Humeral SuturePlate. Surgical Technique

ACL reconstruction with the ACUFEX Director Drill Guide and. ENDOBUTTON CL Fixation System. *smith&nephew. Knee Series Technique Guide ENDOBUTTON CL

ARTHROTUNNELER TUNNELPRO SYSTEM

AcUMEDr. Locking Proximal Humeral Plate. PoLARUSr PHPt

VERSALOK SURGICAL TECHNIQUE FOR ROTATOR CUFF REPAIR SURGICAL TECHNIQUE VERSATILITY STRENGTH SPEED

Locking Radial Head Plates

Surgical Technique. 3.5mm and 4.5mm Lateral Proximal Tibia Locking Plates

Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor

TSLP Thoracolumbar Spine Locking Plate

ACL Reconstruction Medial Portal

Cannula Portfolio NEW

Surgical Protocol by E. Lyle Cain, M.D. and Jeffrey R. Dugas, M.D. of the American Sports Medicine Institute

LCP Medial Proximal Tibial Plate 3.5. Part of the Synthes small fragment Locking Compression Plate (LCP) system.

Strategies for Failed Instability Repair

Complete solutions for hip arthroscopy. Supporting healthcare professionals for over 150 years

Surgical Technique. Targeter Systems Overview

Glenoid Resurfacing Technique Guide

Three Arthroscopic Techniques for Repairing the Rotator Cuff using ULTRATAPE Suture

Osteochondral Flap Repair

TWISTR TM Retrograde Reamer & Cruciate+ Instruments Surgical Technique

Arthroscopic Stabilization of Acute Acromioclavicular Joint Dislocation using the TightRope System Surgical Technique

Foot and Ankle Technique Guide Metatarsal Shortening Osteotomy

OMNISPAN MENISCAL REPAIR SYSTEM Prominent in Strength, Subtle in Profile

COMPARING KIRSCHNER WIRE FIXATION TO A NEW DEVICE USED FOR PROXIMAL INTERPHALANGEAL FUSION

Type II SLAP lesions are created when the biceps anchor has pulled away from the glenoid attachment.

Solutions for Shoulder Arthroscopy

Technique Guide. VersiTomic G-Lok. J. Martin Leland III, M.D. Sub-Pectoral Proximal Biceps Tenodesis

ACL Primary Repair Surgical Technique

Transcription:

Active, yet simple deployment, now with a curved approach SUTUREFIX All-Suture Anchor

Active, yet simple deployment, now with a curved delivery system The SUTUREFIX All-Suture Anchor delivery system tells you when the anchor has deployed via audible, tactile and visual cues. 1,2 New curved guides are designed to aid in suture anchor placement during drilling and insertion.

SUTUREFIX All-Suture Anchor Family Designed to increase the reliability of anchor fixation, 3 the SUTUREFIX All-Suture Anchor lets you know when it deploys, because you can feel it and hear it. Other all-suture anchors require you to pull on the suture strands to deploy the anchors and don t offer distinct feedback as to whether or not successful anchor deployment has taken place. But the active deployment mechanism of SUTUREFIX All-Suture Anchors makes deployment more certain with a tactile and audible click, and do not require manual tensioning. 1,2,3 Once the anchor has been tapped into the pilot hole, deployment is achieved by pulling back the deployment mechanism. As the anchor deploys, it expands laterally in the drill hole, and against the steel inserter. Once the deployment mechanism is pulled all the way back, a click can be heard confirming deployment into the bone. 2 3

Deploys against the inserter, not cortical bone The majority of all-suture anchors rely on first-generation technology that requires the suture strands to be pulled back against the cortical bone in order to deploy them. 2 In comparison, SUTUREFIX All-Suture Anchors represent a second-generation deployment mechanism in which the anchor deploys against the steel inserter rather than the bone itself, 2 so deployment is therefore less dependent upon bone density. When SUTUREFIX anchors deploy, they form a construct against the steel inserter tube, not the cortical bone as required by first-generation all-suture anchors. 2 Significantly better displacement than first-generation all-suture anchors 2 SUTUREFIX All-Suture anchors showed a significantly higher force required to displace 2mm as compared to first generation all-suture anchors (represented here by the Biomet JuggerKnot Soft Anchor) 2. Analysis of variance (ANOVA) test to compare the first- and secondgeneration suture anchor groups. First-generation all-suture anchor: Biomet JuggerKnot Soft Anchor. Second-generation all-suture anchor: Smith & Nephew SUTUREFIX All-Suture Anchor. Newtons 44 42 40 38 36 34 32 * P <.001 Load to 2mm displacement (N) 35.96 * 42.34 * Firstgeneration Secondgeneration 4

Compact size Available single-loaded (1.7 mm) or double-loaded (1.9 mm), the SUTUREFIX All-Suture Anchor s small diameter allows you to place multiple anchors for increased points of fixation. This also creates a large, evenly distributed surface area of tissue compression, providing greater tissue-to-bone contact 1 for a secure repair. Single-loaded 1.7 mm anchor Double-loaded 1.9 mm anchor The cannulated obturator allows for a percutaneous approach, easing access to the inferior portion of the glenoid for those surgeons who prefer a straight guide. Single- and double-loaded options allow surgeons to choose the most suitable repair, based on pathology. Increased bone conservation through smaller bone voids 2 Because of its small size, the 1.7mm SUTUREFIX All-Suture Anchor requires a smaller pilot hole than larger, hard anchors, resulting in less bone removal and greater bone conservation. 2,3 In addition, the short, small-diameter tunnels may reduce the likelihood of tunnel convergence and rim fracture. 3 5

The Curved Guide System improves access to challenging shoulder and hip pathology The SUTUREFIX CURVED Drill Guide improves access and trajectory when drilling bone tunnels. This may reduce the risk of articular surface perforation, bicortical perforation, and converging tunnels. Curve comparison 4 Length of Curve Smith & Nephew SUTUREFIX Biomet JuggerKnot Arthrex FiberTak TM Stryker ICONIX TM Cayenne Medical SureLock TM.7" 1.25" 2.01" 3.50" 4.31" Angle 18.4 15 11 12 and 25 20 Depth in mm 30 25 20 15 10 5 19mm Drill depth 5 21.8mm 23.5mm 24mm 0 SN SUTUREFIX Curved Stryker Iconix Arthrex FiberTak TM Biomet JuggerKnot Tighter distal curve Mid-shaft curve The more distally-placed curve of the SUTUREFIX guide is designed to achieve optimal anchor hole vectors for drilling and anchor insertion. 6

Compared to straight guides, the distally curved guide improves anatomical access Shoulder For shoulder applications, the Curved Drill Guide allows anchors to be placed confidently in the inferior aspect of the glenoid. Tactile and visual cues The Curved Drill Guide has helpful visual and tactile cues that facilitate drill guide positioning and anchor placement. Hip For hip labral repair, the Curved Drill Guide is designed to provide improved access to the acetabular rim when compared to traditional straight guides. An orientation bump provides tactile feedback that corresponds with the direction of the curve. The crescent-shaped laser mark indicates the orientation of the curvature. The posterior laser mark helps with orientation when in the hip. 7

Ordering information SUTUREFIX ULTRA Suture Anchors and Instrumentation Systems for Shoulder Reference # Anchors: 72203852 72203853 72203854 Drills: Description SUTUREFIX ULTRA Anchor 1.7mm S with one (#2) ULTRABRAID suture (blue) SUTUREFIX ULTRA Anchor 1.7mm S with one COBRAID (#2) ULTRABRAID Suture (blue) SUTUREFIX ULTRA Anchor 1.9mm S with two (#1) ULTRABRAID Sutures (COBRAID-blue) 72203855 Twist drill 1.7mm S 72203856 Twist drill 1.9mm S Drill Guide & Obturators: 72203857 Drill Guide crown tip, Reusable, S 72203859 Drill Guide Fishmouth tip, Reusable, S 72203861 Obturator, Blunt tip, Reusable, S 72203862 Obturator, Cannulated, Reusable, S 72203863 Obturator, Trocar tip, Reusable, S SUTUREFIX ULTRA Suture Anchors and Instrumentation Systems for Hip Reference # Anchors: 72203841 72203842 Drills: Description SUTUREFIX ULTRA Anchor 1.7 mm XL with one (#2) ULTRABRAID suture (blue) SUTUREFIX ULTRA Anchor 1.7 mm XL with one (#2) ULTRABRAID suture (COBRAID-blue) 72204669 SUTUREFIX ULTRA Drill 1.7mm XL, Disposable Drill Guide & Obturators: 72203844 Drill Guide XL, Crown Tip 72203845 Drill Guide XL, Spike Tip 72203846 Obturator XL, Blunt Tip 72203899 Obturator XL, Cannulated, Blunt Tip Indications for Use The Smith & Nephew SUTUREFIX Curved Suture Anchors are intended for the secure fixation of soft tissue to bone for the following indications: Shoulder: Capsular stabilization (including Bankart repair, anterior shoulder instability, SLAP lesion repairs, capsular shift or capsulolabral reconstructions, rotator cuff tear repairs, biceps tenodesis) Hip: Acetabular labrum repair/reconstruction Knot Pusher: 72203850 ELITE Knot Pusher XL SUTUREFIX CURVED Suture Anchors and Instrumentation Systems for Shoulder Reference # Anchors: 72204687 72204688 72204689 Drills: Description SUTUREFIX CURVED Anchor 1.7mm with one (#2) ULTRABRAID suture (blue) SUTUREFIX CURVED Anchor 1.7mm with one (#2) ULTRABRAID suture (COBRAID-blue) SUTUREFIX CURVED Anchor 1.9mm with two (#1) ULTRABRAID sutures (blue) 72204690 SUTUREFIX CURVED 1.7, Shoulder Flexible Drill 72204691 SUTUREFIX CURVED 1.9, Shoulder Flexible Drill Drill Guide & Obturators: 72204692 72204694 SUTUREFIX CURVED Shoulder Drill Guide, Crown tip, Reusable SUTUREFIX CURVED Shoulder Obturator, Reusable SUTUREFIX CURVED Suture Anchors and Instrumentation Systems for Hip Reference # Anchors: 72205060 72205061 Drills: Description SUTUREFIX CURVED XL Anchor 1.7mm with one (#2) ULTRABRAID suture (blue) SUTUREFIX CURVED XL Anchor 1.7mm with one (#2) ULTRABRAID suture (COBRAID-blue) 72205062 SUTUREFIX CURVED 1.7, XL Flexible Drill Drill Guide & Obturators: 72205063 SUTUREFIX CURVED XL Drill Guide, Crown tip 72205064 SUTUREFIX CURVED XL Obturator The Smith & Nephew SUTUREFIX Ultra Suture Anchor is intended for the secure fixation of soft tissue to bone for the following indications: Shoulder: Capsular stabilization (including Bankart repair, anterior shoulder instability, SLAP lesion repairs, capsular shift or capsulolabral reconstructions), acromioclavicular separation repairs, deltoid repairs, rotator cuff tear repairs, biceps tenodesis Hip: Hip capsule repair (acetabular labrum repair/reconstruction). Sports Medicine Smith & Nephew, Inc. 150 Minuteman Road Andover, MA 01810 USA www.smith-nephew.com T +1 978 749 1000 US Customer Service: +1 800 343 5717 Trademark of Smith & Nephew. 2018 Smith & Nephew. All rights reserved. Printed in USA. 00496 V3 03/18 Supporting healthcare professionals for over 150 years References 1. Data on file: Report 15002117. 2. Erickson J, Chiarappa F, Haskel J, Rice J, Hyatt A, Monica J, Dhawan A. Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor. The Orthopaedic Journal of Sports Medicine, 5(7), 2017. 3. Data on file: Report 15002059 4. Data on file: Report 15002113. 5. Data on file: Report 15009634.