For Personal Use. Copyright HMP 2013

Similar documents
Hybrid Muscular VSD Closure in Small Weight Children

Percutaneous VSD closure

Type Size AP/PS RP/RS Qp/Qs. Ia Resistive <0.3 < Ib Resistive <0.3 < IIa Resistive <0.5 >2

For Personal Use. Copyright HMP 2013

Imaging Evaluation of the Ventricular Septum

Atrial Septal Defect Closure. Stephen Brecker Director, Cardiac Catheterisation Labs

For Personal Use. Copyright HMP 2013

Treatment of Inter-MitraClip Regurgitation Due to Posterior Leaflet Cleft by Use of The Amplatzer Vascular Plug II device

Journal of Rare Cardiovascular Diseases 2017; 3 (2):

Percutaneous Device Closure of Congenital VSDs Current techniques and results for treating ventricular septal defects.

Transcatheter closure of patent foramen ovale using the internal jugular venous approach

Bioprosthetic Mitral Valve Dysfunction: Innovation and Evolution of a New Therapeutic Technique

Transcatheter Closure of Acute Myocardial Infarction VSD

Jian Fang 1, Shaobo Xie 2, Lunchao Ma 2, Chao Yang 2. Original Article

JOINT MEETING 2 Tricuspid club Chairpersons: G. Athanassopoulos, A. Avgeropoulou, M. Khoury, G. Stavridis

TCTAP C-217 Bilateral Pulmonary Arterio Venus Fistula Managed by Vascular Plugs and Coil Manotosh Panja 1 1 BelleVue Clinic, India

Perimembranous ventricular septal defects (pmvsds) are

Percutaneous atrial septal defect closure with the Occlutech Figulla Flex ASD Occluder.

ATRIAL SEPTAL CLOSURE AND LEFT ATRIAL APPENDAGE OCCLUSION: INDICATIONS AND GUIDANCE ECHOCARDIOGRAPHY IN INTERVENTIONAL CARDIOLOGY

IMAGES. in PAEDIATRIC CARDIOLOGY

The earliest application of intracardiac imaging

Case Report Hemostasis of Left Atrial Appendage Bleed With Lariat Device

Atrial Septal Defects

Διαδερμική θεραπεία των παραβαλβιδικών διαφυγών Σ.Ράμμος

Case Report. Martin L. Bocks, MD and Aimee K. Armstrong, MD

Follow-up after VSD closure- what to look for?

Disclosure Statement of Financial Interest Saibal Kar, MD, FACC

Device closure of congenital ventricular septal defects with Amplatzer devices: first experiences in Turkey

Device Closure of ASD in Children Using the Amplatzer Devices: Indications and catheter preparations, technique, and outcome [15]

Cardiac Valve/Structural Therapies

Perventricular Closure of Muscular VSD

TAVR in Intermediate Risk Populations /Optimizing Systems for TAVR

Muscular VSD Occluder

HOW IMPORTANT ARE THESE ECHO MEASUREMENTS ANYWAY?

Journal of the American College of Cardiology Vol. 33, No. 5, by the American College of Cardiology ISSN /99/$20.

HISTORY. Question: What category of heart disease is suggested by this history? CHIEF COMPLAINT: Heart murmur present since early infancy.

Predictors of unfavorable outcome after atrial septal defect closure in adults

TEE Essential in Paravalvular Leak Closure and Pseudoaneurysm Repair. Gerard T Wilkins

INTEGRATING ECHOCARDIOGRAPHY WITH CATHETER INTERVENTIONS FOR CONGENITAL HEART DISEASE. Krishna Kumar SevenHills Hospital, Mumbai, India

CY2017 Hospital Outpatient: Vascular Procedure APCs and Complexity Adjustments

Giovanni Di Salvo MD, PhD, FESC Second University of Naples Monaldi Hospital

Transcatheter Closures for Fistula Tract and Paravalvular Leak after Mitral Valve Replacement and Tricuspid Annuloplasty

The CardioMEMS HF system (Abbott Vascular,

How to assess an adult with a Ventricular Septal Defect. When it should be closed and how?

Successful Percutaneous Closure of Mitral Bioprosthetic Paravalvular Leak Using Figulla ASD Occluder

Echocardiographic Guidance During Placement of the Buttoned Double-Disk Device for Atrial Septa1 Defect Closure

ΔΙΑΧΕΙΡΙΣΗ ΑΣΘΕΝΩΝ ΜΕ ΜΕΣΟΚΟΛΠΙΚΗ ΕΠΙΚΟΙΝΩΝΙΑ ΖΑΧΑΡΑΚΗ ΑΓΓΕΛΙΚΗ ΚΑΡΔΙΟΛΟΓΟΣ ΗΡΑΚΛΕΙΟ - ΚΡΗΤΗ

Is TAVR Now Indicated in Even Low Risk Aortic Valve Disease Patients

Research Article A New Coated Nitinol Occluder for Transcatheter Closure of Ventricular Septal Defects in a Canine Model

Cigna - Prior Authorization Procedure List Cardiology

Peripheral and Cardiology Coder 2018

Complicated Percutaneous Repair of a Paravalvular Mitral Leak. Dr. K Kam Resident Specialist Division of Cardiology, PWH M&T (Courtesy: Prof.

Percutaneous VSD closure: Problems in the mid- and long-term

ECHOCARDIOGRAPHIC APPROACH TO CONGENITAL HEART DISEASE: THE UNOPERATED ADULT

Transcatheter closure of right coronary artery fistula to the right ventricle

Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics

Risk Factors and Outcomes of Post-Procedure Heart Blocks After Transcatheter Device Closure of Perimembranous Ventricular Septal Defect

Transcatheter Trans-Apical Closure of Paravalvular Mitral and Aortic Leaks Using a New Device: First in Man Experience

2019 MITRACLIP CODING AND PAYMENT GUIDE

Para-valvular Leak Closure

Percutaneous Therapy for Calcific Mitral Valve Disease

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

Originally Posted: November 15, 2014 BRUIT IN THE GROIN

Percutaneous Management Of Prosthetic. Consultant Cardiologist Usha Mullapudi cardiac Center Hyderabad

Percutaneous Transapical Access for Thoracic Endovascular Repair

A challenging case of successful ASD closure without echocardiographic guidance in an 86-year old with severe kyphoscoliosis and platypnoeaorthodeoxia

Diagnostic & Therapeutic Cardiac Catheterization Coder 2017

Transcatheter Closure of Atrial Septal Defects with Superior-anterior Rim Deficiency Using Amplatzer Septal Occluder

National Imaging Associates, Inc. Clinical guidelines CARDIAC CATHETERIZATION -LEFT HEART CATHETERIZATION. Original Date: October 2015 Page 1 of 5

When Does 3D Echo Make A Difference?

IMAGES. in PAEDIATRIC CARDIOLOGY. Abstract

8/31/2016. Mitraclip in Matthew Johnson, MD

25 different brand names >44 different models Sizes mm

AMPLATZER Septal Occluder

Para-valvular Leak Closure

2 Brigham and Women s Hospital, Boston, MA.

Diversion of the inferior vena cava following repair of atrial septal defect causing hypoxemia

Transcatheter Closure of Secundum Atrial Septal Defect in Patients Over 60 Years Old

Fabien Praz, Andreas Wahl, Sophie Beney, Stephan Windecker, Heinrich P. Mattle*, Bernhard Meier

Subacute left ventricular outflow tract obstruction after transapical closure of a mitral paravalvular leak in the region of the aortomitral curtain

Implantation of Cardioverter Defibrillator After Percutaneous Closure of Atrial Septal Defect

Anatomy & Physiology

Transcatheter closure of the patent ductus arteriosus using the new Amplatzer duct occluder: Initial clinical applications in children

Percutaneous Mitral Valve Repair

Intracardiac echocardiography: an ideal guiding tool for device closure of interatrial communications

Rahul Jhaveri, M.D. The Heart Group of Lancaster General Health

Early and Late Complications Associated With Transcatheter Occlusion of Secundum Atrial Septal Defect

Mitral Valve Disease, When to Intervene

Transcatheter aortic valve replacement with intracardiac echocardiography from the right internal jugular vein

Update on Percutaneous Therapies for Structural Heart Disease. William Thomas MD Director of Structural Heart Program Tucson Medical Center

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type.

Transseptal catheterization is an established

Percutaneous closure of large VSD using a home-made fenestrated atrial septal occluder in 18-year-old with pulmonary hypertension

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

CONGENITAL HEART DEFECTS IN ADULTS

Transcatheter Atrial Septa1 Defect Closure: Preliminary Experience with the Rashkind Occluder Device

Glenmark Cardiac Centre Mumbai, India

Left ventricular pseudoaneurysm is a rare but serious

CATHETERIZATION PROTOCOL Prepared by Matthew Crystal ( )

Transcription:

Case Report J INVASIVE CARDIOL 2013;25(2):E42-E44 Percutaneous Closure of Iatrogenic Ventricular Septal Defect Following Surgical Aortic Valve Replacement Using Two Different Approaches Takashi Matsumoto, MD, Wen-Loong Yeow, MD, Saibal Kar, MD Abstract: Iatrogenic ventricular septal defect (VSD) is a rare complication following surgical aortic valve replacement (SAVR). In this report, we describe two cases of iatrogenic VSD following SAVR (both mechanical and bioprosthetic aortic valve), which were successfully closed with two different percutaneous techniques (retro-aortic and transseptal approach). The report discusses the differences in the techniques and the literature supporting the procedure. J INVASIVE CARDIOL 2013;25(2):E42-E44 For Personal Use. Copyright HMP 2013 Key words: ventricular septal defect, aortic valve replacement complication Ventricular septal defect (VSD) is a recognized but rare complication of surgical aortic valve replacement (SAVR) and percutaneous closure has become the intervention of choice. Successful percutaneous closure depends on the anatomical location of the defect, the type of prosthetic valve, and the corrective technique employed. In this report, we discuss two cases of successful closure with different percutaneous techniques (retro-aortic and transseptal approach). Case reports Patient 1. A 72-year-old man developed severe shortness of breath, New York Heart Association (NYHA) class III following redo-savr with an On-X mechanical aortic valve (On-X Life Technologies). Postoperatively, he developed complete heart block (CHB) requiring a permanent pacemaker (PPM) implantation. He remained very symptomatic and further evaluation revealed a 9 mm subaortic VSD (Figure 1A). In view of the fact that the patient had undergone two openheart surgical procedures, he was considered to be very high risk for a third open-heart surgery. He was therefore referred for consideration of percutaneous closure of the iatrogenic VSD. The procedure was performed under general anesthesia with transesophageal echocardiographic (TEE) guidance. A retro-aortic approach was planned and access was obtained with a 6 Fr sheath in the right femoral artery (RFA) and an 8 Fr sheath in the right femoral vein (RFV). The calculated shunt fraction (Qp/Qs) was 4:1. An attempt was made to cross the VSD using the standard retro-aortic technique. A multipurpose catheter with a wire was advanced very easily across the mechanical aortic valve, through the VSD without any difficulty. However, immediately after crossing the defect, the patient developed severe aortic insufficiency (AI) and hypotension, requiring removal of the catheter and wire. A transseptal (TS) approach was then employed. TS puncture was performed in the mid fossa of the atrial septum under fluoroscopy and TEE guidance. A Mullins sheath was then advanced into the left ventricle (LV) and a left ventriculogram (LV gram) confirmed a moderate-sized subaortic VSD (Figure 2A). A 7 Fr end-hole balloon floatation catheter was advanced through the Mullins sheath and easily floated across the VSD into the right ventricle (RV) (Figure 2B). A 300-cm long 0.035 Noodle wire (AGA Medical) was advanced through the balloon floatation catheter into the pulmonary artery (PA). The wire was then snared using a 25 mm GooseNeck Snare (ev3) and exteriorized from the RFV, thus forming a venous-arterial-venous loop. An 8 Fr 45 Amplatzer Torque Vue Sheath (AGA Medical Corporation) was advanced through the right femoral vein over the wire into the LV. A 14 mm Amplatzer Muscular VSD Occluder was then deployed successfully under fluoroscopic (Figure 2C) and TEE guidance. Of note, the superior edge of the left side disc hinged on the inferior aspect of the aortic valve prosthesis, without

causing dysfunction of the mechanical prosthetic valve as confirmed by echocardiography and angiography. Postprocedural calculated Qp/Qs ratio was reduced to 1.2:1. On the following day, transthoracic echocardiogram (TTE) revealed no significant residual shunt and the patient was discharged home without any complications (Figure 1B). At 3-year followup, the patient remains asymptomatic with no residual shunt or valve dysfunction. Patient 2. An 86-year-old female presented with ongoing fatigue and shortness of breath on exertion (NYHA class III) 5 months after a bioprosthetic SAVR, and was found to have developed a 4 mm subaortic VSD (Figure 3A). In the absence of other causes, it was felt that this iatrogenic VSD was the cause of her symptoms. The baseline echocardiography confirmed that there was sufficient rim below the aortic valve for consideration for percutaneous closure. Following discussion with the cardiac surgeons, it was felt that the percutaneous approach would be preferable to redo sternotomy. The procedure was performed under general anesthesia with fluoroscopic and TEE guidance. Two 6 Fr sheaths were placed in the RFA and RFV, respectively. The baseline Qp/Qs ratio was 1.5:1. Intraprocedural TEE and LV gram confirmed a 4 mm subaortic VSD (Figure 4A). A retroaortic approach was planned, and the VSD was crossed retrograde using a 6 Fr internal mammary catheter and 0.035 angled Terumo Glidewire (Terumo). Unlike the previous case, there was no hemodynamic compromise or significant aortic insufficiency with the catheter across the valve. The wire and catheter were advanced across the VSD into the PA. The Terumo wire was exchanged with a 300-cm long 0.035 Noodle wire. The tip of the wire was snared in the PA and exteriorized from the RFV, completing an arterial-venous loop (Figure 4B). The 7 Fr 45 Amplatzer Torq Vue sheath was then advanced from the RFV over the wire across the VSD into the LV. In a similar fashion as the previous case, a 6 mm Amplatzer Muscular VSD Occluder was successfully placed across the VSD. Echocardiography and angiography confirmed the successful closure of the defect without aortic valve dysfunction (Figure 4C). Postprocedural calculated Qp/Qs ratio was 1:1. The patient was discharged home the following day with no significant residual shunt confirmed by TTE (Figure 3B). Two weeks after the procedure, the patient developed asymptomatic CHB, detected on routine follow-up ECG, requiring PPM implantation. At 3-year follow-up, the patient remained asymptomatic with no significant residual shunt or aortic valve dysfunction. For Personal Use. Copyright HMP 2013 Discussion Disruption of the left ventricular outflow tract during SAVR can rarely result in a VSD. Mechanical complications such as a paravalvular leak or VSD should be considered in the differential diagnosis in patients who continue to have symptoms of left heart failure following SAVR. Asymptomatic VSD without evidence of LV volume overload and/or a calculated left to right shunt greater than 1.5, does not require closure. In both cases here, following a thorough evaluation, the iatrogenic VSD was considered to cause persistent heart failure following surgery. Due to inherent risk of redo-sternotomy, a transcatheter rather than redo surgical closure should be considered as the first option. 1-4 In both these instances, the defect size and the presence of a small rim below the aortic valve allowed percutaneous closure. Due to the angulated right cardiac anatomy and trabeculated RV, VSDs are crossed from the LV side with either a retro-aortic or TS approach. The presence of a mechanical valve in the aortic position offers challenges in crossing of the valve with a wire and catheter. Successful closure of an iatrogenic VSD by crossing the defect via a retro-aortic approach through a bileaflet mechanical valve has been described in the literature. 1 On the other hand crossing a mono-disc mechanical aortic valve can be dangerous and potentially fatal. 5 The fear of catheter entrapment across mechanical aortic valve led to the TS approach, first described by Klein et al. 4 In this approach, access is gained to the LV by performing a TS puncture and advancing a Mullins sheath from the femoral vein to the LA and then LV. The VSD is then crossed using a balloon flotation catheter through the Mullins sheath. The flow across the VSD helps the flotation catheter to float across the defect. As discussed by the authors, the important aspects of this technique are a catheter and wire loop in the left ventricular outflow tract to direct and support

passage into and across the VSD, and the chase the dragon technique utilizing wire support in the delivery sheath to prevent kinking of the sheath during device advancement. Inadvertent anterograde catheter and wire entrapment across the mechanical aortic valve could still occur while probing the VSD and if there is excessive laxity in the venous-arterial-venous loop. Also, if there is excessive tension in the venous-arterial-venous loop, the intra-atrial septum and mitral apparatus could be serrated. As yet, the TS approach in a patient with mechanical mitral valve replacement has not been described. For patients with a bioprosthetic aortic valve, the retro-aortic approach is the best method, and for patients with a bileaflet mechanical aortic valve, a retro-aortic approach could be attempted first as long as the hemodynamics are closely monitored, and then switched to a TS approach if unsuccessful. Once the VSD is crossed, any soft exchange-length (240 cm or 300 cm) J-tipped wire can be used to create the arterial-venous or venous-arterial-venous loop. In our case, a soft 300-cm long Noodle wire was used. This wire has been specially designed for this purpose. However, any soft exchange-length wire can be used. The size and type of VSD occluder device is important The Amplatzer Muscular VSD Occluder is the only device available for transcather closure of a VSD in the United States. Each device comprises two nitinol discs connected by a waist. The sizes of the device range from 4 to 18 mm (waist diameter). Each of the discs is 5 to 8 mm larger than the waist. The size of the defect is measured at end diastole by TEE and/or left ventricular angiography. A device that is 2 mm larger than the maximum measured diameter should be selected. An important contraindication for percutaneous closure of VSD is absence of any subaortic rim. In the first case, there was no rim below the aortic valve; however, we could anchor this device against the lower half of the rim of the mechanical valve without interfering with the leaflets. In the second case, there was a small 4 mm rim just below the prosthetic valve, which allowed the adequate anchoring of the device. Post-SAVR heart block can occur either from disruption of tissue during the surgery or following transcatheter closure of the defect. This is the most common complication and can occur in up to 9% of cases with 4%-6% requiring PPM implantation. 6,7 In the first case, the patient required a pacemaker following the SAVR and in the second case, a PPM was implanted 2 weeks after closure of the VSD due to symptomatic CHB. The mechanism leading to CHB remains uncertain; direct compression or inflammation of the atrioventricular conduction bundle is plausible. Indeed, anti-inflammatory therapy or surgical device removal is effective in some cases. 6,7 Percutaneous closure is a safe and effective treatment of an iatrogenic VSD following SAVR. Different approaches may be employed depending on the type of prosthetic aortic valve. For Personal Use. Copyright HMP 2013 References 1. Holzer R, Latson L, Hijazi Z. Device closure of iatrogenic membranous VSD after prosthetic aortic valve replacement using the Amplatzer membranous VSD occluder. Catheter Cardiovasc Interv. 2004;62(2):276-280. 2. Dodos F, Fehske W, Hoppe U, Sreeram, N. Transcatheter closure of iatrogenic perimembranous ventricular septal defect following prosthetic aortic valve replacement. Clin Res Cardiol. 2008;97(1):53-55. 3. Noble S, Ibrahim R. Transcatheter membranous VSD closure through a mechanical aortic prosthesis using the Amplatzer membranous VSD occluder. Catheter Cardiovasc Interv. 2009;73(2):167-172. 4. Klein AJ, Garcia JA, Carroll JD. Percutaneous closure of an iatrogenic VSD following mechanical aortic valve replacement using the transseptal technique. Catheter Cardiovasc Interv. 2007;70(7):1018-1024. 5. Horstkotte D, Jehle J, Loogen F. Death due to transprosthetic catheterization of a Bjork- Shiley prosthesis in the aortic position. Am J Cardiol. 1986;58(6):566-567.

6. Butera G, Carminati M, Chessa M, et al. Transcatheter closure of perimembranous VSD: early and long-term results. J Am Coll Cardiol. 2007;50(12):1189-1195. 7. Carminati M, Butera G, Chessa M, et al. Transcatheter closure of congenital VSD: results of the European Registry. Eur Heart J. 2007;28(19):2361-2368. C. 3 se 01 lu 2 na MP so H er ht r P rig Fo opy From the Heart Institute, Cedars-Sinai Medical Center, Los Angeles, California. Disclosure: The authors have completed and returned the ICMJE Form for Disclosure of Potential Conflicts of Interest. Dr Kar is a grant recipient and consultant for St Jude Medical, Boston Scientific, Abbott Vascular, and Gore Medical. The remaining authors report no financial relationships or conflicts of interest regarding the content herein. Manuscript submitted August 6, 2012, provisional acceptance given September 7, 2012, final version accepted October 1, 2012. Address for correspondence: Saibal Kar, MD, FACC, FAHA, FSCAI, Heart Institute, CedarsSinai Medical Center, 8631 W. Third Street. Room 415E, Los Angeles, CA 90048. Email: saibal.kar2@cshs.org Figure 1. Transesophageal echocardiogram of case 1 (A) with the 9 mm ventricular septal defect (white arrow). Postprocedural transthoracic echocardiogram (B) with a 14 mm Amplatzer Muscular VSD Occluder (white arrow). RA = right atrium; RV = right ventricle; LA = left atrium; LV = left ventricle.

Figure 2. Angiographic images in case 1. (A) Left ventriculogram revealing ventricular septal defect (white arrow) and an On-X mechanical aortic valve (black arrow). (B) 7 Fr Berman wedge catheter (white arrow) crossing ventricular septal defect. (C) The GooseNeck snare (white arrow) capturing the Noodle wire, completing a venous-arterial-venous loop. (D) Final left ventriculogram with minimal flow across the occluder.. 3 se 01 lu 2 na MP so H er ht r P rig Fo opy C Figure 3. Transesophageal echocardiogram of case 2 (A) with the 4 mm ventricular septal defect (white arrow). Postprocedural transthoracic echocardiogram with (B) 6 mm Amplatzer Muscular VSD Occluder (white arrow). RA = right atrium; RV = right ventricle; LA = left atrium; LV = left ventricle.

C. 3 se 01 lu 2 na MP so H er ht r P rig Fo opy Figure 4. Angiographic images in case 2. (A) Left ventriculogram revealing ventricular septal defect (white arrow) and bioprosthetic valve (black arrow). (B) An arterial-venous loop through the ventricular septal defect (white arrow). (C) Final left ventriculogram with minimal flow across the occluder.