Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique

Similar documents
CrossFix II. All-Suture, All-Inside Meniscal Repair System. Surgical Technique

Knee Preservation System

Visit Linvatec.com today to learn more. Surgical Technique: Sequential Meniscal Running Stitch

Chart a course for meniscal preservation

CHANGING THE WAY YOU LOOK AT THINGS

GraftLink All-Inside ACL Reconstruction with ACL TightRope ABS Surgical Technique

ACL Reconstruction with ACL TightRope Surgical Technique

The Ceterix NovoStitch Disposable Suture Passer. Do Not Reuse

Arthrex PassPort Button Cannula. Maximize visibility and maneuverability inside and outside of the arthroscopic workspace

PCL GraftLink Surgical Technique

ACL Primary Repair Surgical Technique

Surgical Protocol written by Keith Lawhorn, M.D.

AFX. Femoral Implant. System. The AperFix. AM Portal Surgical Technique Guide. with the. The AperFix System with the AFX Femoral Implant

GraftLink All-Inside ACL

SpeedBridge and SpeedFix Knotless Rotator Cuff Repair using the SwiveLock C and FiberTape Surgical Technique

Subpectoral Biceps Tenodesis using Cortical Buttons Surgical Technique

SpeedBridge and SpeedFix Knotless Rotator Cuff Repair using the SwiveLock C and FiberTape Surgical Technique

OMNISPAN MENISCAL REPAIR SYSTEM Prominent in Strength, Subtle in Profile

Passer. Sterile. D i. Do Not PASSER DESCRIPTION. The Ceterix. Page 1

Arthroscopic Stabilization of Acute Acromioclavicular Joint Dislocation using the TightRope System Surgical Technique

Double Bundle PCL Reconstruction. Surgical Technique

Anatomic AC Joint TightRope Fixation

VERSALOK SURGICAL TECHNIQUE FOR ROTATOR CUFF REPAIR SURGICAL TECHNIQUE VERSATILITY STRENGTH SPEED

EndoBlade Soft Tissue Release System

Arthroscopic Shoulder Repair Using the Smith & Nephew KINSA Suture Anchor

Technique Guide. *smith&nephew N8TIVE ACL Anatomic ACL Reconstruction System

Twin Tail TightRope System

Transtibial PCL Reconstruction. Surgical Technique. Transtibial PCL Reconstruction

Technique Guide. *smith&nephew SPEEDSCREW Fully Threaded Knotless Implant

Bio-Tenodesis Screw Fixation

ACL Reconstruction with Flipped BTB Graft Surgical Technique

ACL Reconstruction for BTB Grafts

Osteochondral Flap Repair

GENERAL TECHNIQUE GUIDE

FLUID MANAGEMENT FLUID MANAGEMENT

Rotator Cuff Repair using JuggerKnot Soft Anchor 2.9mm Surgical Technique

MULTIFIX S Knotless Implants

RetroButton for Femoral ACL Reconstruction and RetroConstruction Surgical Technique

Technique Guide. *smith&nephew MAGNUM 2 Knotless Implant

ARTHROSCOPIC GIANT NEEDLE ROTATOR CUFF REPAIR AS A ROUTINE PROCEDURE SINCE 1990

Lateral Meniscus Transplant

SwiveLock & FiberChain Knotless Rotator Cuff Repair. SwiveLock & FiberChain Knotless Rotator Cuff Repair. Surgical Technique

The AperFix II System

ROTATOR CUFF REPAIR WITH STATAK SUTURE ANCHORS

HEALIX TRANSTEND Implant System: A percutaneous solution for partial tears of the rotator cuff. Partial tear. Complete solution.

Technique Guide. MULTIFIX P PEEK 4.5mm Knotless Fixation Implant

Active, yet simple deployment, now with a curved approach. SUTUREFIX All-Suture Anchor

HIP ARTHROSCOPY BROCHURE

COR. Precision Targeting Cartilage Repair System. Arthroscopic Technique for Repair of Osteochondral Defects

Arthroscopic Shoulder Instability Repair Using the Curved Guide and Anchor Delivery System

PCL Reconstruction Utilizing the TightRope /GraftLink Technique Juxtaposed to posterior horn

DEVELOPED BY MEDSHAPE, INC. IN CONJUNCTION WITH PATRICK ST. PIERRE, M.D. BICEPS TENODESIS ARTHROSCOPIC AND SUBPECTORAL SURGICAL TECHNIQUE

CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE

SURGICAL TECHNIQUE VISUALIZE FEMORAL FIXATION 360 GRAFT TO BONE CONTACT INCREASED PULL-OUT STRENGTH

Imola Lateral IBF System Surgical Technique

SureLock All-Suture Anchor System

TissueMend. Arthroscopic Surgical Technique. Arthroscopic Insertion of a Biologic Rotator Cuff Tissue Augment After Rotator Cuff Repair

Thumb UCL Repair with InternalBrace Ligament Augmentation. Surgical Technique. Thumb UCL Repair with InternalBrace Augmentation

System. Humeral Nail. Surgical Technique

Surgical Technique. Foot and Ankle Technique Guide Ankle Syndesmosis Repair, Operative Technique

FIXED PERFORMANCE. Soft Tissue ACL Reconstruction

3. PATIENT POSITIONING & FRACTURE REDUCTION 3 8. DISTAL GUIDED LOCKING FOR PROXIMAL NAIL PROXIMAL LOCKING FOR LONG NAIL 13

Comprehensive Product Offerings for Your Rotator Cuff Repair

Tibial Fixation. with TunneLoc Device. Surgical Technique by Mark J. Albritton, M.D. and Sherwin Ho, M.D.

GraftLink All-Epiphyseal, All-Inside ACL Reconstruction with ACL TightRope ABS Surgical Technique

CROSS PIN TECHNOLOGY FOR AN ANATOMIC ACL

Modified Brostrom-Gould Technique

ComposiTCP Anchor with BroadBand Tape

Percutaneous Humeral Fracture Repair Surgical Technique

Humeral SuturePlate. Surgical Technique

Rotator Cuff Repair Utilizing the ALLthread Suture Anchor. by Scott Kuiper, M.D.

7% - 15% Single Tunnel Repair of Plantar Plate. Savings of. are common with EcoSMART *Patent Pending

TABLE OF CONTENTS. 2 (8144 Rev 2)

JuggerKnot Soft Anchor 1.4/1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff SLAP Repair

JuggerLoc Bone-to-Bone System for Ankle Syndesmosis Fixation. Surgical Technique

Torn ACL Hamstring Graft

ARTHROTUNNELER TUNNELPRO SYSTEM

Meniscus cartilage replacement with cadaveric

Y-Knot Flex NEW. All-Suture Anchor System

Valencia Pedicle Screw Surgical Technique

Bio-FASTak Bankart Repair. Surgical Technique

SURGICAL TECHNIQUE PREPARED BY MEDSHAPE, INC. IN CONJUNCTION WITH JACK FARR, M.D. MPFL RECONSTRUCTION

Meniscus Reconstruction: Trough Surgical Technique

Zimmer ITST Intertrochanteric/ Subtrochanteric Fixation System. Abbreviated Surgical Technique

ADJUSTABLE CONVENIENCE, FIXED PERFORMANCE

Instructions for Use

What Is The Optimal Penetration Depth For "All-Inside" Meniscal Repairs?

Look For These Other Products by PARÉ Surgical, Inc. INNOVATIVE MEDICAL DEVICES

Minimally Invasive Quad Tendon Harvest System Surgical Technique

The next generation in all suture implant technology. Q-FIX All-Suture Implants

PAL Pelvic Alignment Level

DeltaCut / CoreCut / PrimoCut

Arthroscopic Rotator Cuff Repair: Mastering the Essentials

Nit-Occlud. Coil System for PDA Closure IMPLANTATION POCKET GUIDE. Rx only CV / B. Braun Interventional Systems Inc.

Three Arthroscopic Techniques for Repairing the Rotator Cuff using ULTRATAPE Suture

JuggerKnot Soft Anchor 1.5 mm with Percutaneous Instrumentation for Low Profile/Trans-Cuff PASTA Repair

mild Devices Kit - Instructions for Use

ToggleLoc Inline Device

Surgical Technique. CONQUEST FN Femoral Neck Fracture System

Transcription:

Arthroscopic Meniscal Repair using the Meniscal Cinch Surgical Technique Arthroscopic Meniscal Repair

Small PEEK implants and 2-0 FiberWire provide secure, low profile fixation Slotted, curved cannula allows easy access to tear and protects implants during positioning External depth stop protects structures external to capsule Pretied sliding knot tensions easily and reproducibly Ergonomic, pistol grip handle allows easy maneuverability 120 Ultimate Load 100 80 98 N Newtons 60 40 74 N 20 31 N 0 Meniscal Cinch FasT-Fix MaxFire Data on file

The Meniscal Cinch allows surgeons to consistently repair meniscus tears with an all-inside arthroscopic technique, eliminating the need for accessory incisions required for traditional inside/out techniques that often result in additional morbidity. Based on the tear pattern and location, the Meniscal Cinch gives surgeons the option of horizontal or vertical mattress repair with 2-0 FiberWire suture. The preset sliding knot and the FiberWire properties create a secure, low profile knot that can be countersunk into the meniscus. Depending on exact location and pattern, posterior horn tears can be repaired through standard ipsilateral or contralateral arthroscopy portals. The Meniscal Cinch is placed through the contralateral or accessory contralateral portal for tears involving the body of the meniscus. Positioning the Meniscal Cinch Hold the Meniscal Cinch by placing the index finger above the cannula, the middle finger below the cannula and the first trocar pinched between the base of the thumb and index fingers. Deploy the implant by squeezing the trocar and handle together.

1 2 The Meniscal Cinch is designed to be used through a low arthroscopic portal, near the surface of the tibia. Use the Measurement Probe or the graduated tip of the Meniscal Cinch cannula to measure the approximate distance from the entry point of the implant to capsule. Note: Each line represents 2 mm. Set the depth stop on the Meniscal Cinch handle by squeezing the tips together and sliding the depth stop forward. Set the depth stop to a distance equal to the measurement in step one. Note: Each line on the cinch handle represents 2 mm. 3 a A Shoehorn Cannula or PassPort Button Cannula may be placed into the working portal before inserting the Meniscal Cinch device. Place the tip of the Meniscal Cinch cannula near the tear. The tip of the cannula may be used to reduce the tear prior to deployment of the first trocar (a). Alternatively, the tip of the first trocar may be advanced past the tip of the cannula to be used to reduce the tear (b). Note: Never pull the trocar back into the cannula after it has been advanced, as this could prematurely deploy the implant. b 4 Advance the first implant through the meniscus by pushing trocar #1 until the trocar handle makes contact with the depth stop and the cannula rests on the surface of the meniscus.

Dealing with Resistance of the Trocar through the Meniscus and Capsule If resistance is encountered while trying to pass the implant, it is important not to push too firmly on the handle of the Meniscal Cinch as this could cause damage to the meniscus from the tip of the cannula. It is best to advance the trocar all the way to the depth stop, allowing the trocar to come out of the cannula in the joint. Keep controlled forward pressure of the trocar while rotating back and forth 90. This can be done using a onehanded technique. Since the depth stop is already bottomed out, the trocar is inserted until the tip of the cannula touches the meniscus. This signals appropriate insertion depth.

5 6 Remove trocar #1 from the cannula completely. A slight downward force on trocar #1 during removal will ensure that it does not interfere with trocar #2. Push down on trocar #2 to release it from the holding position. Move the tip of the cannula to the second insertion point over the meniscus. Important: Do not move or pull back on the Meniscal Cinch handle after deploying implant #1 until implant #2 trocar has been released from the locked position. 7 8 Advance trocar #2 forward by pushing the trocar handle forward. Advance trocar #2 through the meniscus until the trocar handle makes contact with the depth stop and the cannula rests on the surface of the meniscus. Note: Suture slack created by advancing trocar #2 may be reduced partially by gently tensioning external suture near the handle. Stop tensioning if resistance is felt. Remove trocar #2. Remove the Meniscal Cinch from the joint. Tension external suture to advance the knot to the meniscus. Note: If the knot doesn t slide smoothly, stop pulling tension on the suture and use the Knot Pusher to advance the knot.

9 10 a Use the suture threader to insert the external suture through the tip of the Knot Pusher/Suture Cutter. Push the knot while pulling tension on the free end of the suture. Advance the knot until countersunk into the meniscal tissue. Hold tension on the suture. Rotate the handle 90 clockwise. Advance the trigger on the handle of the Knot Pusher/Suture Cutter to cut suture. Pull suture firmly. Note: Pull suture in line with the Knot Pusher and avoid rotation of the handle until ready to cut. Remove the cutter. Alternatively (a): A vertical mattress stitch may be placed by inserting the implants in a vertical orientation. Refer to the Directions for Use for device-specific indications, adverse effects, warnings and precautions. Ordering Information Meniscal Cinch Knot Pusher/Suture Cutter, disposable AR-4500 AR-4515 Optional Instruments and Accessories: Shoehorn Cannula, disposable AR-6565 Measurement Probe, reusable AR-13920P 2-0 Knot Pusher, reusable AR-1296 2-0 Suture Cutter, straight, reusable AR-11790 2-0 Suture Cutter, 15 up, reusable AR-11791 Additional Cannulas: PassPort Button Cannula, 6 mm I.D. x 2 cm PassPort Button Cannula, 6 mm I.D. x 3 cm PassPort Button Cannula, 6 mm I.D. x 4 cm PassPort Button Cannula, 6 mm I.D. x 5 cm PassPort Button Cannula, 8 mm I.D. x 2 cm PassPort Button Cannula, 8 mm I.D. x 3 cm PassPort Button Cannula, 8 mm I.D. x 4 cm PassPort Button Cannula, 8 mm I.D. x 5 cm PassPort Button Cannula, 10 mm I.D. x 2 cm PassPort Button Cannula, 10 mm I.D. x 3 cm PassPort Button Cannula, 10 mm I.D. x 4 cm PassPort Button Cannula, 10 mm I.D. x 5 cm AR-6592-06-20 AR-6592-06-30 AR-6592-06-40 AR-6592-06-50 AR-6592-08-20 AR-6592-08-30 AR-6592-08-40 AR-6592-08-50 AR-6592-10-20 AR-6592-10-30 AR-6592-10-40 AR-6592-10-50

This description of technique is provided as an educational tool and clinical aid to assist properly licensed medical professionals in the usage of specific Arthrex products. As part of this professional usage, the medical professional must use their professional judgment in making any final determinations in product usage and technique. In doing so, the medical professional should rely on their own training and experience and should conduct a thorough review of pertinent medical literature and the product s Directions For Use. U.S. PATENT NO. 6,716,234 and PATENT PENDING 2011, Arthrex Inc. All rights reserved. LT0107D