Diabetes Care Publish Ahead of Print, published online September 11, 2007

Similar documents
Long-term effects of continuous glucose monitoring on HbA 1c levels: An audit

Diabetes Care 34: , 2011

Accuracy of the SEVEN Continuous Glucose Monitoring System: Comparison with Frequently Sampled Venous Glucose Measurements

Clinical Value and Evidence of Continuous Glucose Monitoring

Systematic Review of the Effectiveness of Continuous Glucose Monitoring (CGM) on Glucose Control in Type 2 Diabetes

Limitations of Conventional Methods of Self-Monitoring of Blood Glucose

A Review of Current Evidence with Continuous Glucose Monitoring in Patients with Diabetes

Diabetes Care 25: , 2002

C I T I U S A L T I U S F O R T I U S - J O U R N A L O F P H Y S I C A L E D U C A T I O N A N D S P O R T

Continuous Glucose Monitoring (CGM)

Reduction in Hypoglycemia and No Increase in A1C with Threshold-Based Sensor-Augmented Pump (SAP) Insulin Suspension: ASPIRE In-Home

Continuous Glucose Monitoring: Changing Diabetes Behavior in Real Time and Retrospectively

Continuous Glucose Monitoring System in children with type 1 diabetes mellitus: a systematic review and meta-analysis

POLICIES AND PROCEDURE MANUAL

PREVENTION OF NOCTURNAL HYPOGLYCEMIA USING PREDICTIVE LOW GLUCOSE SUSPEND (PLGS)

Abstract CLINICAL APPLICATIONS. Objectives: Methods: Results: Conclusion: Journal of Diabetes Science and Technology

Reproducibility of Glucose Measurements Using the Glucose Sensor

Diabetes Management Continuous Glucose Monitoring

Continuous Glucose Monitoring (CGM)

Abstract REVIEW ARTICLE. Objective: Methods: Results: Journal of Diabetes Science and Technology

Norbert Hermanns, PhD 1,2, Beatrix Schumann, MD 2, Bernhard Kulzer, PhD 1,2, and Thomas Haak, MD 1,2. Original Article

Diabetes Management with Continuous Glucose Monitoring & Multiple Daily Injections. Aaron Michels MD

What is a CGM? (Continuous Glucose Monitor) The Bionic Pancreas Is Coming

Artificial Pancreas Device System (APDS)

Insulin Delivery and Glucose Monitoring Methods for Diabetes Mellitus: Comparative Effectiveness

Early Patient and Clinician Experiences with Continuous Glucose Monitoring

Control of Glycemic Variability for Reducing Hypoglycemia Jae Hyeon Kim

A Prospective Evaluation of Insulin Dosing Recommendations in Patients with Type 1 Diabetes at Near Normal Glucose Control: Bolus Dosing

INFUSYSTEMS USA. INFUSYSTEM

Advances in Diabetes Care Technologies

Development of Optimal Kids Insulin Dosing System Formulas for Young Children with Type 1 Diabetes Mellitus

Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)

Continuous Glucose Monitoring Devices Pharmacy Policy

Continuous glucose monitoring provides

Diabetes Technology Continuous Subcutaneous Insulin Infusion Therapy And Continuous Glucose Monitoring In Adults: An Endocrine Society Clinical

T he ultimate goal of diabetes technology

Continuous Glucose Monitoring: The Future of Diabetes Management

Advances in Diabetes Care Technologies

Rates of Glucose Change Measured by Blood Glucose Meter and the GlucoWatch Biographer During Day, Night, and Around Mealtimes

Comparative Analysis of the Efficacy of Continuous Glucose Monitoring and Self-Monitoring of Blood Glucose in Type 1 Diabetes Mellitus

Since the discovery of insulin, the management of type 1 diabetes

Evaluation of a Continuous Glucose Monitoring System for Home-Use Conditions

Advances in Diabetes Care Technologies

Original Article. Nicholas B. Argento, MD 1 ; Katherine Nakamura, PhD 2 ABSTRACT

Role of Mobile Technology to Improve Diabetes Care in Adults with Type 1 Diabetes: The Remote-T1D Study ibgstar Ò in Type 1 Diabetes Management

Continuous Glucose Monitoring System

In general: Hypoglycemia is common in insulin treated diabetes, but may also occur in people on oral medications, especially sulfonylureas/glinides.

Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes

More Than 1 Year of Hybrid Closed Loop in Pediatrics. Gregory P. Forlenza, MD Assistant Professor Barbara Davis Center

Glycaemic impact of patient-led use of sensor-guided pump therapy in type 1 diabetes: a randomised controlled trial

Effective Health Care Program

Continuous Glucose Monitoring System

Continuous Glucose Monitoring System

Continuous or Intermittent Monitoring of Glucose in Interstitial Fluid. Original Policy Date

PRACTICAL WAYS TO ACHIEVE TARGETS IN DIABETES CARE July 12-15, 2012 Keystone, Colorado

Diabetes: Definition Pathophysiology Treatment Goals. By Scott Magee, MD, FACE

Abstract. Richard R. Rubin, Ph.D., CDE, 1,2 and Mark Peyrot, Ph.D. 1,3 ORIGINAL ARTICLES. Background: Methods: Results:

INSULIN THERAY دکتر رحیم وکیلی استاد غدد ومتابولیسم کودکان دانشگاه علوم پزشکی مشهد

When Will CGM Replace SMBG? Roy W. Beck, MD, PhD. JAEB Center for Health Research Tampa, Florida

Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?

Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico

Do fat and protein affect post prandial glycemia in the outpatient real world setting? Neha Verma, MD Robert Melfi, MD

Diabetes Care 26: , 2003

The Diamond Study: Continuous Glucose Monitoring In Patients on Mulitple Daily Insulin Injections

Coverage Guidelines. Continuous Glucose Monitors (CGMs)

James J. Chamberlain, MD 1, Dana Dopita, RN, MSN, CDE 1, Emily Gilgen, RD, CD, CDE 1, and Annie Neuman, MPA, PA-C 1.

Clinical Policy Title: Continuous interstitial glucose monitoring (CGM)

Use of Continuous Glucose Monitoring in the Detection and Prevention of Hypoglycemia

Performance-powered. The OneTouch. Ping insulin pump and meter-remote.

Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes

Corporate Medical Policy

Subjects and Methods 2017, 64 (8),

Preventing Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension

PREVALENCE AND EXTENT OF GLYCEMIC EXCURSIONS IN WELL- CONTROLLED PATIENTS WITH TYPE 2 DIABETES MELLITUS USING CONTINUOUS GLUCOSE-MONITORING SYSTEM

Description. Section: Durable Medical Equipment Effective Date: July 15, 2014 Subsection: Original Policy Date: December 7, 2011 Subject:

How to maintain glycaemic success in adolescents using CSII Rebecca Thompson discusses how to engage with this often challenging group. Page 6.

Diabetes Care Publish Ahead of Print, published online December 20, 2007

Clinical Policy Title: Continuous interstitial glucose monitoring (CGM)

Interpretation of Continuous Glucose Monitoring (CGM) Data

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump

Continuous Glucose Monitoring Devices for Patients with. Diabeles Mellitus on Insulin. California Technology Assessment Forum

Continuous Blood Glucose Monitor AHM

Non-insulin treatment in Type 1 DM Sang Yong Kim

The In-Clinic Close Loop Experience in the US

Real-Life Utilization of Real-Time Continuous Glucose Monitoring: The Complete Picture

Pumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University

Basics of Continuous Subcutaneous Insulin Infusion Therapy. Lubna Mirza, MD Norman Endocrinology Associates 2018

ORIGINAL ARTICLE. Use of Freestyle Libre Pro TM Flash Glucose Monitoring System in Different Clinical Situations at a Diabetes Centre

Continuous Glucose Monitoring

CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION

Diabetes Management in Toddlers/Preschoolers (<6 yo)

Incremental Value of Continuous Glucose Monitoring When Starting Pump Therapy in Patients With Poorly Controlled Type 1 Diabetes

Hypoglycemia Prediction with Subject-Specific Recursive Time-Series Models

NO SIMPLE TEST currently exists for assessment of glycemic

Artificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes

The importance of continuous glucose monitoring when transitioning a patient from insulin detemir to U-500R

Journal Club ICU

Recommendations for Using Real-Time Continuous Glucose Monitoring (rtcgm) Data for Insulin Adjustments in Type 1 Diabetes

Exercise Prescription in Type 1 Diabetes

Transcription:

Diabetes Care Publish Ahead of Print, published online September 11, 2007 Slicing the Pie with Continuous Home Monitoring of Glucose: Improved Glycemic Control with Real-life use of Continuous Glucose Sensors in Adult Subjects with Type 1 Diabetes 1, 2, 3 Satish K. Garg, MD William C. Kelly, BS 1 Mary K. Voelmle, MS, FNP, CDE 1, 3 Peter J. Ritchie, BA 1 1, 2, 3 Peter A. Gottlieb, MD Kim K. McFann, PhD 1, 4 Samuel L. Ellis, PharmD, CDE 1, 5 1 Barbara Davis Center for Childhood Diabetes, Aurora, Colorado; 2 Internal Medicine, 3 Pediatrics, 4 Preventive Medicine and Biometrics, 5 University of Colorado at Denver, Aurora, Colorado. Running Title: Real-life use of CHMG Correspondence: Satish K. Garg, MD, Barbara Davis Center for Childhood Diabetes, University of Colorado at Denver, 1775 North Ursula Street, Aurora, CO 80045, Email: satish.garg@uchsc.edu Received for publication 24 July 2007 and accepted in revised form 31 August 2007. Copyright American Diabetes Association, Inc., 2007

Improving metabolic control reduces microand macrovascular complications of diabetes. However, intensive insulin therapy increases severe hypoglycemia >3 fold (1-3). Continuous glucose monitoring (CGM) is being introduced into routine clinical care despite a lack of reimbursement. Registration studies for FDA documented that subjects using realtime CGM are improve glucose excursions, reduce variability, decrease time spent in hypoglycemia and hyperglycemia and improve A1c values (4-9). Despite these reports, there is data unsupportive of new technologies such as CGM (10) or Personal Digital Assistants (11) for reducing hypoglycemia. This study evaluates glucose control and its relationship to glucose target ranges with Continuous Home Monitoring of Glucose (CHMG). Research Design and Methods Inclusion criteria limited analysis to subjects with A1c values and downloaded CHMG data at baseline and 3 months and software to download receivers (not available for first 9 months). Patients who were pregnant or planning a pregnancy were excluded. Twenty-four subjects on CHMG were included in this analysis. Subjects were computer matched for baseline A1c (± 0.3%), gender, age, and duration of diabetes except for one subject in the CHMG group who had diabetes for 57 years. Baseline demographics were similar between groups (Table). This protocol was IRB approved. Procedures Subjects initiating CHMG attended a session on glucose trends, features of the CHMG receiver, and proper insertion techniques, conducted by CDE s. All subjects were instructed to not change treatment based on their first week of CHMG use. All subjects had baseline and 12 week A1c measurements (DCA 2000 Bayer, Tarrytown, NY). The CHMG data was downloaded prospectively at baseline, 6 (± 2), and 12 weeks 12 (± 2) weeks, except for one subject who did not have 6 week data. Subjects wore sensors as they felt necessary. Every 3 days subjects were taught to override the receiver and use the same sensor for an additional 3 days. All subjects in the comparison group received similar diabetes care. No six-week data or finger stick SMBG measurements were available for the comparison group. CHMG data was analyzed for within (WTR, 60-150 mg/dl), above (ATR, > 150 mg/dl), and below (BTR, < 60 mg/dl) target ranges. The BTR of < 60 mg/dl was used due to clinical observations that subjects using CHMG are more likely to treat glucose values of 60 mg/dl, as opposed to 70 mg/dl, which was used for BTR in our previous SMBG publication (12). The ATR readings were further analyzed for 151-240 mg/dl and > 240 mg/dl. The percentages of readings within each target range were compared between baseline, 6, and 12 weeks. The number of subjects reaching target A1c values were also analyzed. No subject had severe hypoglycemia needing glucagon or ER visits. Statistical Analysis Analysis of A1c change from baseline and time within glycemic ranges was performed using SAS 9.1 software (SAS, Cary, NC). Two-tailed tests were used unless otherwise stated. Baseline characteristics were compared using independent samples T-tests. Fisher s Exact tests were performed on the number of subjects reaching target A1c values at baseline. Logistic regression, with baseline 2

A1c target as a covariate, was used to examine whether the experimental group was more likely than the comparison group to reach A1c targets by 3 months. Mixed model repeated measures analysis was used to evaluate the change over time in A1c, insulin dose, WTR, BTR and ATR within the CHMG group. Results Mean (± SD) sensor use per subject was 17.6 ± 8.4 days per month. Subjects extended use (despite 3 day approval and now 7 days) of sensors to 6.8 ± 1.6 days. Changes in A1c Mean (± SD) A1c values at baseline were 7.43 ± 1.0% and 7.39 ± 1.0% for the CHMG and comparison groups, respectively (p = 0.896, Table). There was a significant decrease in A1c in the CHMG group (0.4% ± 0.5%; p = 0.047; Mixed Repeated Measures Analysis) at 12 weeks with a non-significant increase in A1c (0.3 ± 1.1%; p = 0.0710) in the comparison group. Also, at 12 weeks there was a difference in A1c values between groups (p = 0.0385), despite no change in insulin dose. Number of subjects achieving A1c values < 7.5% was higher in the CHMG group at 12 weeks (OR = 7.229, p = 0.0234) (13). Glucose Target Ranges Subjects using CHMG increased mean (± SD) glucose readings in WTR by 6.5 ± 15.0% (p = 0.0353), and reduced mean glucose readings in ATR by 5.6 ± 16.7% (p = 0.0355) at 12 weeks compared to baseline. Glucose values in ATR also showed a significant reduction in readings > 240 mg/dl by 6.4 ± 14.0% (p = 0.0351) at 12 weeks. Results were similar for subjects using MDI or insulin pumps. Conclusions This study demonstrates that use of real-time CHMG is associated with improved metabolic control over 12 weeks in adults with type 1 diabetes as documented previously (8, 14-19). This study supports previous findings carrying over to real-life use of CHMG in subjects with reasonable glucose control (A1c ~ 7.4%). The modest improvement in A1c of 0.4% could be due to the subject population, short term nature of the study, and near target baseline A1c values of 7.43%. Improvements in metabolic control with CHMG were not associated with increased hypoglycemia, supporting earlier findings (8, 14-19). The mean increase in WTR of 6.5% and decrease in ATR of 5.6% at 3 months corresponded to a 0.4% decline in A1c, which is lower than expected from our previous SMBG data (12). This could be due to lower A1c values at baseline. Limitations of this study include a small sample size, shorter follow up and lack of a randomized control group. However, the data shows that CHMG use results in a small A1c reduction without increasing hypoglycemia, probably due to behavioral changes. We conclude that use of CHMG can further improve glucose control in relatively well controlled subjects with type 1 diabetes, with no increase in hypoglycemia. Prospective randomized clinical trials using CHMG with a large sample size need to be conducted. Acknowledgments This study was sponsored in part by grant 08 FLA 00250, State of Colorado Public Health and Environment; grant P30 DK575616 Diabetes Endocrine Research Center, National Institutes of Health; grant M01 RR00069 General Clinical Research Centers Program, National Institutes of Health; grant R01 HL61753, RO1 HL079611, RO1 DK32493, and Children s Diabetes Foundation in Denver, CO. 3

References 1: The effect of intensive treatment of diabetes on the development and progression of longterm complications in insulin-dependent diabetes mellitus. The Diabetes Control and Complications Trial Research Group. N Engl J Med 329:977-86, 1993 2: Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group. Lancet 352:837-53, 1998 3: Sustained effect of intensive treatment of type 1 diabetes mellitus on development and progression of diabetic nephropathy: the Epidemiology of Diabetes Interventions and Complications (EDIC) study. JAMA 290:2159-67, 2003 4: Garg SK, Schwartz S and Edelman SV: Improved glucose excursions using an implantable real-time continuous glucose sensor in adults with type 1 diabetes. Diabetes Care 27:734-8, 2004 5: Garg S and Jovanovic L: Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor. Diabetes Care 29:2644-9, 2006 6: Diess D, Bolinder J, Riveline JP, Battelino T, Bosi E, Tubiana-Rufi N, Kerr D, and Phillip M: Improved glycemic control in poorly controlled patients with type 1 diabetes using realtime continuous glucose monitoring. Diabetes Care 29:2730-2, 2006 7: Bailey T, Zisser H, Garg S: Reduction in hemoglobin A1c with real-time continuous glucose monitoring: results from a 12-week observational study. Diabetes Technol Ther 8:203-210, 2007 8: Chase HP, Kim LM, Owen SL, MacKenzie TA, Klingensmith GJ, Murtfeldt R and Garg SK: Continuous subcutaneous glucose monitoring in children with type 1 diabetes. Pediatrics 107:222-6, 2001 9: Kaufman FR, Austin J, Neinstein A, Jeng L, Halvorson M, Devoe DJ, Pitukcheewanont P: Nocturnal hypoglycemia detected with the continuous glucose monitoring system in pediatric patients with type 1 diabetes. J Pediatr 141:625-630, 2002 10: Hirsch I, Bode B, Abelseth J, Fischer J, Kaufman F, Mastrototaro J, Wolpert H, and Buckingham B: Sensor augmented pump therapy: results of the first treat-to-target study (Abstract 0090-OR). Diabetes 56 (spp1):a24, 2007 11: Ellis S, Beatson C, Gottlieb P, Gutin R, Bookout T, Figal C, Snyder B, and Garg S: Improved glycemic control in intensively treated subjects with type 1 diabetes using Accu- Chek Advisor insulin guidance software (Abstract 0031-OR). Diabetes 56 (spp1): A8, 2007 12: Brewer KW, Chase HP, Owen S and Garg SK: Slicing the pie. Correlating HbA1c values with average blood glucose values in a pie chart form. Diabetes Care 21:209-12, 1998 13: American Diabetes Association: clinical practice recommendations 2006. Diabetes Care 29 (spp1):s1-s85, 2006 14: Bode BW, Gross TM, Thornton KR and Mastrototaro JJ: Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study. Diabetes Res Clin Pract 46:183-90, 1999 15: Chase HP, Roberts MD, Wightman C, Klingensmith G, Garg SK, Van Wyhe M, Desai S, Harper W, Lopatin M, Bartkowiak M, Tamada J and Eastman RC: Use of the GlucoWatch Biographer in children with type 1 diabetes. Pediatrics 111:790-4, 2003 4

16: Ludvigsson J and Hanas R: Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics 111:933-8, 2003 16: Ludvigsson J and Hanas R: Continuous subcutaneous glucose monitoring improved metabolic control in pediatric patients with type 1 diabetes: a controlled crossover study. Pediatrics 111:933-8, 2003 17: Schaepelynck-Belicar P, Vague P, Simonin G and Lassmann-Vague V: Improved metabolic control in diabetic adolescents using the continuous glucose monitoring system (CHMGS). Diabetes Metab 29:608-12, 2003 18: Schiaffini R, Ciampalini P, Fierabracci A, Spera S, Borrelli P, Bottazzo GF and Crino A: The Continuous Glucose Monitoring System (CHMGS) in type 1 diabetic children is the way to reduce hypoglycemic risk. Diabetes Metab Res Rev 18:324-9, 2002 19: Tanenberg R, Bode B, Lane W, Levetan C, Mestman J, Harmel AP, Tobian J, Gross T and Mastrototaro J: Use of the Continuous Glucose Monitoring System to guide therapy in patients with insulin-treated diabetes: a randomized controlled trial. Mayo Clin Proc 79:1521-6, 2004 5

Table: Demographics and Results Baseline CHMG Comparison p- value n 24 23 NS* Age (years) 45.8 ± 13.2 44.3 ± 13.4 0.703 Duration (years) 27.2 ± 16.6 24.0 ± 15.8 0.513 Gender M/F 11/13 10/13 0.871 BMI (kg/m 2 ) 26.1 ± 4.1 26.9 ± 4.8 0.565 Treatment MDI CSII 3 Months CHMG Comparison p-value 18 16 6 7 0.677 A1c (%) 7.43 ± 1.0 7.39 ± 1.0 0.896 7.06 ± 0.8 7.73 ± 1.4 0.039 Target A1c A1c < 7.5% 14/24 13/23 0.900 20/24 12/23 0.023 A1c < 7.0% 7/24 6/23 0.814 12/24 6/23 0.211 A1c < 6.5% 4/24 4/23 1.000 4/24 3/23 1.000 Insulin Dose 51.9 ± 31.4 45.7 ± 28.6 0.413 50.1 ± 31.4 49.0 ± 33.4 0.310 Glucose Target Ranges WTR (%) 42.6 ± 19.5 n/a n/a 49.1 ± 16.7 n/a 0.0353 ATR (%) 53.2 ± 20.4 n/a n/a 47.6 ± 17.0 n/a 0.0355 BTR (%) 4.2 ± 3.5 n/a n/a 3.4 ± 6.7 n/a 0.638 * Non-significant Represents values in ± SD There was a significant decrease (p= 0.047) in A1c in the CHMG group from baseline to 3 months. There was no significant change in total insulin dose in the CHMG or comparison group from baseline to 3 months. Within the target range (WTR) glycemia was defined as 60-150 mg/dl (3.3-8.3 mmol/l). These p values represent differences in glucose target ranges from baseline to 3 months in the CHMG group using mixed model repeated measures analysis. 6