Abstract ID 352 Stereotactic radiosurgery for multiple brain metastases: A dose-volume study Tanya Kairn 123, Somayeh Zolfaghari 1, Daniel Papworth

Similar documents
WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY

Variable Dose Rate Dynamic Conformal Arc Therapy (DCAT) for SABR Lung: From static fields to dynamic arcs using Monaco 5.10

Establishing the impact of temporary tissue expanders on

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

Leksell Gamma Knife Icon A New User s Perspective

Original Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem

The Physics of Oesophageal Cancer Radiotherapy

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Case Study. Institution Farrer Park Hospital

Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

NSABP PROTOCOL B-39B RTOG PROTOCOL 0413

Fractionated SRT using VMAT and Gamma Knife for brain metastases and gliomas a planning study

8/2/2018. Acknowlegements: TCP SPINE. Disclosures

RPC Liver Phantom Highly Conformal Stereotactic Body Radiation Therapy

Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)

Small field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST

Quality assurance of volumetric modulated arc therapy using Elekta Synergy

Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

A dosimetric evaluation of VMAT for the treatment of non-small cell lung cancer

Is dosimetry of multiple mets radiosurgery vendor platform dependent? Y. Zhang

Treating Multiple. Brain Metastases (BM)

Leila E. A. Nichol Royal Surrey County Hospital

Overview of MLC-based Linac Radiosurgery

Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Treatment Planning for Lung. Kristi Hendrickson, PhD, DABR University of Washington Dept. of Radiation Oncology

Disclosure SBRT. SBRT for Spinal Metastases 5/2/2010. No conflicts of interest. Overview

BLADDER RADIOTHERAPY PLANNING DOCUMENT

Evaluation of a dedicated brain metastases treatment planning optimization for radiosurgery: a new treatment paradigm?

ICRU Report 91 Was ist neu, was ändert sich?

Radiosurgery. Most Important! 8/2/2012. Stereotactic Radiosurgery: State of the Art Technology and Implementation Linear Accelerator Radiosurgery

A Novel Fluence Modified Base Plan IMRT for Second-irradiation Planning Technique

Evaluation of Three-dimensional Conformal Radiotherapy and Intensity Modulated Radiotherapy Techniques in High-Grade Gliomas

Current Concepts and Trends in Spinal Radiosurgery. Edward M. Marchan

A Comparison of IMRT and VMAT Technique for the Treatment of Rectal Cancer

IROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015

Case Conference: SBRT for spinal metastases D A N I E L S I M P S O N M D 3 / 2 7 / 1 2

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

A comparison of dose distributions measured with two types of radiochromic film dosimeter MD55 and EBT for proton beam of energy 175 MeV

Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy

Let s speak the same language: Standardization in Terminology

Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

ARROCase Brain Metastases

Evaluation of Whole-Field and Split-Field Intensity Modulation Radiation Therapy (IMRT) Techniques in Head and Neck Cancer

Chapters from Clinical Oncology

Efficient SIB-IMRT planning of head & neck patients with Pinnacle 3 -DMPO

SRS Uncertainty: Linac and CyberKnife Uncertainties

SRS Plan Quality and Treatment Efficiency: VMAT vs Dynamic Conformal ARCs

A Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population

Brain metastases are common brain malignant neoplasms

Tania Kaprealian, M.D. Assistant Professor UCLA Department of Radiation Oncology August 22, 2015

The dosimetric effect of electron density overrides in 3DCRT Lung SBRT for a range of lung tumor dimensions

Activity report from JCOG physics group

THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS

A method to improve dose gradient for robotic radiosurgery

4 Essentials of CK Physics 8/2/2012. SRS using the CyberKnife. Disclaimer/Conflict of Interest

SBRT of Lung & Liver lesions using Novalis IGRT System. Patrick Silgen, M.S., DABR Park Nicollet Methodist Hospital

SBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session

Clinical Implementation of SRS/SBRT

Intensity-modulated stereotactic radiosurgery for arteriovenous malformations: guidance for treatment planning

IGRT Protocol Design and Informed Margins. Conflict of Interest. Outline 7/7/2017. DJ Vile, PhD. I have no conflict of interest to disclose

Original Date: April 2016 Page 1 of 7 FOR CMS (MEDICARE) MEMBERS ONLY

NIH Public Access Author Manuscript Int J Radiat Oncol Biol Phys. Author manuscript; available in PMC 2008 October 1.

Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC)

Feasibility of using the Vero SBRT system for intracranial SRS

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Linac Based SBRT for Low-intermediate Risk Prostate Cancer in 5 Fractions: Preliminary Report of a Phase II Study with FFF Delivery

Physics update for radiation oncologists (2)

ph fax

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

Disclosures. Overview 8/3/2016. SRS: Cranial and Spine

Cover Page. The handle holds various files of this Leiden University dissertation

3D printing of air slab caps for correction free small field dosimetry. Benjamin Perrett, Paul Charles, Tim Markwell, Tanya Kairn, Scott Crowe

Gamma Knife radiosurgery with CT image-based dose calculation

Statistical Analysis and Volumetric Dose for Organ at Risk of Prostate Cancer

NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning

VMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT

SBRT in early stage NSCLC

Prostate Phantom. Guidelines for Planning and Treating the IMRT Prostate Phantom. Revised March 2014

Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film

Dosimetric Analysis of 3DCRT or IMRT with Vaginal-cuff Brachytherapy (VCB) for Gynaecological Cancer

Stereotactic Body Radiotherapy for Lung Lesions using the CyberKnife of-the-art and New Innovations

3D Conformal Radiation Therapy for Mucinous Carcinoma of the Breast

Outline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams

Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy

STEREOTACTIC RADIOSURGERY FOR

biij Initial experience in treating lung cancer with helical tomotherapy

Flattening Filter Free beam

The impact of dose prescription on treatment volume

Defining Target Volumes and Organs at Risk: a common language

Ritu Raj Upreti, S. Dayananda, R. L. Bhalawat*, Girish N. Bedre*, D. D. Deshpande

It s All About Margins. Maaike Milder, Ph.D. Accuray Symposium April 21 st 2018

Strategies and Technologies for Cranial Radiosurgery Planning: Gamma Knife

Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery

3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients

Transcription:

Abstract ID 352 Stereotactic radiosurgery for multiple brain metastases: A dose-volume study Tanya Kairn 123, Somayeh Zolfaghari 1, Daniel Papworth 2, Mark West 2, David Schlect 2, Scott Crowe 13 1 Queensland University of Technology, Brisbane, Australia 2 Genesis Cancer Care Queensland, Genesis Care, Brisbane, Australia 3 Royal Brisbane and Women's Hospital, Brisbane, Australia t.kairn@gmail.com

Aims & objectives A substantial number of cancer patients develop brain metastases, which often present as multiple lesions. Stereotactic radiosurgery (SRS) can be used to treat brain metastases, with some incidental dose to the healthy brain [1]. This study evaluated the effect of the number and combined volume of metastatic lesions on the deliverability and dosimetric quality (in particular 12 Gy coverage of healthy brain) of a small sample of SRS test treatments.

Aims & objectives The more metastases a patient has, the higher the dose delivered to the healthy brain by the radiosurgery treatment. The threshold at which linac-based SRS becomes clinically unacceptable remains debatable Many centres limit the number of radiosurgically treated metastases to 3 or 4 [1, 4] Treatments of 10 to 14 metastases within a course of radiosurgery have been reported [2, 3] The volume of healthy brain receiving a dose of 12 Gy is widely recognised as a useful predictor of radionecrosis and consequent neurocognitive decline [5, 6] QUANTEC reported a signficant risk of radiation injury from radiosurgery when the volume of brain tissue receiving 12 Gy exceeds 5-10 cm 3 [7] Blonigen et al recommend a specific limit of 7.9 cm 3 [5]

Materials and methods Five simulated test cases: 4 metastases, 6 metastases, 8 metastases, 10 metastases, 12 metastases PTVs contoured on CT scan of a CIRS 605 head phantom Healthy brain structure created by subtracting all PTVs (plus 1 mm dose fall-off margin) from brain contour

Materials and methods Two sets of prescriptions, two sets of plans: PTV doses of 14-80 Gy prescribed to 90% covering isodose, according to local practise PTV dose of 24 Gy prescribed to 90% covering isodose (prescription taken from RTOG 0320 1-3 met trial protocol [4]) Linac-based, multi-isocentre, static conformal arc treatments, with Brainlab m3 micromlc, planned using Brainlab iplan TPS, with reference to published small field beam data [8] Four mets Twelve mets

Materials and methods Film measurements: Gafchromic EBT3 radiochromic film placed within head phantom, in the transverse plane Phantom immobilised, imaged and treated as though it was a cranial SRS patient Film analysis and comparisons with planned dose planes completed using established techniques [9, 10]

Results & discussion Dose profile comparisons show: For four to eight metastases, the TPS accurately predicted the delivered dose. For ten or twelve metastases, disagreement between the film measurement and the TPS dose calculation increased, with the TPS generally over-estimating the out-of-field dose. These results suggest that the TPS dose calculation can be used as a worst-casescenario estimate of the healthy brain dose. Four mets Eight mets Twelve mets Four mets Eight mets Twelve mets

Results & discussion Increasing the number of targets requires increasing the number of beams, the number of MUs and the total radiation dose delivered by the SRS treatment, while also complicating the challenge of arranging the beams to spare the healthy brain. Local prescription Local prescription RTOG prescription RTOG prescription

Results & discussion Several of the test plans resulted in clinically acceptable 12 Gy coverage of the healthy brain (less than 7.9 cm 3 [5]), when local dose prescriptions (14 to 18 Gy) were used, but when the prescription dose to all metastases was increased 24 Gy (a prescription designed for treating no more than three metastases [4]), no plans resulted in a V12 less than 10 cm 3. Dose plane, twelve mets

Conclusion Using a multi-isocentre static conformal arc method, it is possible to deliver treatments to relatively large numbers and total volumes of brain metastases without excessive radiation doses being delivered to the healthy brain, provided it is acceptable to compromise the prescription dose. If prescription doses above 18 Gy are required for such cases, the decision to use SRS and the particular SRS method selected for use may both need to be reconsidered.

References 1. Tsao, M.N., Rades, D., Wirth, A., et al.: Pract. Radiat. Oncol. 2, 210-225 (2012). 2. Hunter, G.K., Suh, J.H., Reuther, A.M., et al.: Int. J. Radiat. Oncol. Biol. Phys. 83(5), 1394-1398 (2012). 3. Schultz, D., Modlin, L., Jayachandran, P., et al.: Int. J. Radiat. Oncol. Biol. Phys. 92(5), 993-999 (2015). 4. Sperduto, P.W., Wang, M., Robins, H.I., et al.: Int. J. Radiat. Oncol. Biol. Phys. 85(5), 1312-1318 (2013). 5. Blonigen, B.J., Steinmetz, R.D., Levin, L., et al.: Int. J. Radiat. Oncol. Biol. Phys. 77(4), 996-1001 (2010). 6. Sahgal, A., Barani, I., Novotny, J., et al.: Int. J. Radiat. Oncol. Biol. Phys. 78(2), 605-608 (2010). 7. Lawrence, Y.R., Li, X.A., el Naqa, I., et al.: Int. J. Radiat. Oncol. Biol. Phys. 76(3), S20-S27 (2010). 8. Kairn, T., Charles, P.H., Cranmer-Sargison, G., et al.: Australas. Phys. Eng. Sci. Med. 38(2), 357-367 (2015). 9. Kairn, T., Hardcastle, N., Kenny, J., et al.: Australas. Phys. Eng. Sci. Med. 34(3), 333-343 (2011). 10. Kairn, T., West, M.: Australas. Phys. Eng. Sci. Med. 39(1), 341-342 (2016).

Conflict of interest The authors declare that they have no conflict of interest.