Automated pull-down of extracellular vesicles (EVs) on the KingFisher system using Dynabeads magnetic beads standardizing EV capture and analysis

Similar documents
MagCapture Exosome Isolation Kit PS Q&A

PRODUCT INFORMATION & MANUAL

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81)

Flow Cytometry Based Exosome Detection and Analysis Using the ZE5 Cell Analyzer

A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis

Comercial Rafer in Zaragoza

Extracellular Vesicle RNA isolation Kits

Production of Exosomes in a Hollow Fiber Bioreactor

Insight into cancer research from discovery to validation

Concentration Estimation from Flow Cytometry Exosome Data Protocol

In vitro human regulatory T cell expansion

Exosomes Immunocapture and Isolation Tools: Immunobeads

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell culture

vol.3 Highlight Product: ExoCap Product Research tools for extracellular vesicles - Exhibition booth at Taiwan on November

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Plasma

Urine Exosome RNA Isolation Kit Product #47200

In vitro human regulatory T cell expansion

Purification and Fluorescent Labeling of Exosomes Asuka Nanbo 1*, Eri Kawanishi 2, Ryuji Yoshida 2 and Hironori Yoshiyama 3

Exosome detection and characterization based on flow cytometry.

RayBio KinaseSTAR TM Akt Activity Assay Kit

For Reseach Use Only. ExoCap TM. Product Catalog. Research tools for extracellular vesicles

A new approach to characterize exosomes and study their interactions with biomolecules. Silvia Picciolini PhD student 30 th May 2016

In vitro human regulatory T cell suppression assay

Application of μmacs Streptavidin MicroBeads for the analysis of HIV-1 directly from patient plasma

Development of a Human Cell-Free Expression System to Generate Stable-Isotope-Labeled Protein Standards for Quantitative Mass Spectrometry

USE OF EXOSOMES IN TRANSLATIONAL AND CLINICAL RESEARCH. Eva Colás Ortega Postdoc researcher IRBLleida

Exo-Glow TM Exosome Labeling Kits

EXOTESTTM. ELISA assay for exosome capture, quantification and characterization from cell culture supernatants and biological fluids

Extracellular Vesicle Quantification Kits

EXOSOMES & MICROVESICLES

A NOVEL AFFINITY-BASED METHOD FOR EXOSOME ISOLATION ISOLATION OF HIGHLY PURIFIED AND INTACT EXOSOMES AND OTHER EXTRACELLULAR VESICLES

Annexin V-PE Apoptosis Detection Kit

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Service and Collaboration

Gladstone Institutes, University of California (UCSF), San Francisco, USA

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

Figure S1. PMVs from THP-1 cells expose phosphatidylserine and carry actin. A) Flow

EXO-Prep One step Exosome isolation Reagent

Long term stability of isolated human serum derived exosomes

Supplementary Figure 1. mrna targets were found in exosomes and absent in free-floating supernatant. Serum exosomes and exosome-free supernatant were

SMART Digest Kit Facilitating perfect digestion

For Research Use Only Ver

COMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.

The effect of temperature and incubation time on the analysis of highly sialylated glycans from bovine fetuin

EXO-DNAc Circulating and EV-associated DNA extraction kit

University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA; e Boone Pickens

Products for cfdna and mirna isolation. Subhead Circulating Cover nucleic acids from plasma

For Research Use Only Ver

Rapid antigen-specific T cell enrichment (Rapid ARTE)

TECHNICAL BULLETIN. Catalog Number RAB0447 Storage Temperature 20 C

ab Membrane Fractionation Kit Instructions for Use For the rapid and simple separation of membrane, cytosolic and nuclear cellular fractions.

- 1 - Cell types Monocytes THP-1 cells Macrophages. LPS Treatment time (Hour) IL-6 level (pg/ml)

Assays for Immunology Research IncuCyte S3 Live-Cell Analysis System

Minute TM Plasma Membrane Protein Isolation and Cell Fractionation Kit User Manual (v5)

Exosomes Immunocapture and Isolation Tools: Immunoplates

The Immunoassay Guide to Successful Mass Spectrometry. Orr Sharpe Robinson Lab SUMS User Meeting October 29, 2013

ROS Activity Assay Kit

For purification of viral DNA and RNA from a wide range of sample materials

SUPPORTING MATREALS. Methods and Materials

EXO-DNA Circulating and EV-associated DNA extraction kit

MagniSort Human CD4 Memory T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

X P. Supplementary Figure 1. Nature Medicine: doi: /nm Nilotinib LSK LT-HSC. Cytoplasm. Cytoplasm. Nucleus. Nucleus

MagniSort Mouse CD4 Naive T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

STAT3 (py705)/ Pan STAT3 (Human/Mouse/Rat) ELISA Kit

SUPPLEMENTARY FIGURES

For Research Use Only Ver

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

EXO-Prep. Product Insert. Kit for exosome isolation from biofluids or cell culture supernatants HBM-EXP-##

Direct ex vivo characterization of human antigen-specific CD154 + CD4 + T cells Rapid antigen-reactive T cell enrichment (Rapid ARTE)

Data Sheet IL-2-Luciferase Reporter (Luc) - Jurkat Cell Line Catalog # 60481

MTC-TT and TPC-1 cell lines were cultured in RPMI medium (Gibco, Breda, The Netherlands)

ExoQuick Exosome Isolation and RNA Purification Kits

TECHNICAL BULLETIN. Phospho-Akt (pser 473 ) ELISA Kit for detection of human, mouse, or rat phospho-akt (pser 473 ) in cell and tissue lysates

Exosome DNA Extraction Kits

Supplementary Information

SMART Digest and SMART Digest ImmunoAffinity (IA) Kit Technical Guide

Midi Plant Genomic DNA Purification Kit

MagniSort Mouse CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

Protocol for Gene Transfection & Western Blotting

Chromatin IP (Isw2) Fix soln: 11% formaldehyde, 0.1 M NaCl, 1 mm EDTA, 50 mm Hepes-KOH ph 7.6. Freshly prepared. Do not store in glass bottles.

STAT3 (py705) (Human/Mouse/Rat) ELISA Kit

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

Product Contents... 1 Specifications... 1 Product Description... 2 Buffer Preparation... 3 Protocol Appendix... 5 Ordering Information...

Supplementary Material

MagniSort Human CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

EGFR (py1045)/ Pan EGFR (Human) ELISA Kit

Data Sheet TIGIT / NFAT Reporter - Jurkat Cell Line Catalog #60538

Primary Adult Naïve CD4+ CD45RA+ Cells. Prepared by: David Randolph at University of Alabama, Birmingham

The Schedule and the Manual of Basic Techniques for Cell Culture

Comparison of DNA and RNA from fresh-frozen vs. FFPE tissue samples

NF-κB p65 (Phospho-Thr254)

EPIGENTEK. EpiQuik Global Acetyl Histone H3K27 Quantification Kit (Colorimetric) Base Catalog # P-4059 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Exo-spin Exosome Purification Kit For cell culture media/urine/saliva and other low-protein biological fluids

Exosomes, Extracellular Vesicles A Technology Review

Supplementary Figure 1. Method development.

TSH Receptor Monoclonal Antibody (49) Catalog Number MA3-218 Product data sheet

XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma)

155 S. Milpitas Blvd., Milpitas, CA USA T: (408) F: (408)

7-AAD/CFSE Cell-Mediated Cytotoxicity Assay Kit

Transcription:

PPLICTION NOTE KingFisher Flex Purification System utomated pull-down of extracellular vesicles (EVs) on the KingFisher system using Dynabeads magnetic beads standardizing EV capture and analysis xl. Neurauter, ente Kierulf, erit M. Reed, and Ketil W. Pedersen Thermo Fisher Scientific, Ullernchausseen 52, 0379 Oslo, Norway Goal Exploring the biology of extracellular vesicles (EVs) and their potential use in clinical applications has gained considerable interest over the last several years by researchers. In biomarker and liquid biopsy assays, EVs are regarded as complementary or even superior to both cellfree DN (cfdn) and circulating tumor cells (CTCs). So far, the main focus has been on the nucleic acid cargo of EVs, namely the microrn (mirn) and mrn. However, the protein cargo of EVs is highly complex, involved in numerous biological functions, and ripe for further indepth analysis. In addition, researchers believe EVs show potential for therapeutic applications such as drug delivery, immune modulation, and cell-based regenerative medicine. Here we present an automated system for the isolation of EVs for further downstream protein analysis using Invitrogen Dynabeads magnetic beads and the Thermo Scientific KingFisher Flex instrument. Introduction Exosomes ( 1 nm) are extracellular vesicular structures secreted by all cells in culture and found in body fluids [1]. Exosomes are involved in antigen presentation [2], apoptosis, angiogenesis, inflammation, and coagulation [3]. They can activate signaling pathways or deliver nucleic acids to distant cells [4-6]. Tumor-derived exosomes can enhance cancer progression, suppressing the immune response and transferring oncogenes from tumor host cells [7]. Targeting exosomes could increase the efficacy of therapeutic antibodies. Exosomes are formed by invagination of the endosomal membrane, forming multivesicular bodies containing mirn and mrn [6,8-11]. The protein composition mirrors their endocytic origin and includes multivesicular body (MV) machinery, tetraspanins (e.g.,, CD81), heat shock proteins, as well as lipid-related proteins and phospholipases [12-13] and their possible role in intercellular communication [14]. Currently, exosomes are isolated by differential ultracentrifugation, density gradients or cushions [15], size-exclusion chromatography [16], or precipitation [17-19]. To obtain ultrapure exosomes or isolate potential subpopulations of exosomes, a manual or automated immunomagnetic isolation strategy can be applied by targeting exosomal markers [20,21].

Materials and methods Cell culture and exosome pre-enrichment SW480 cells (TCC) were cultured to confluence in RPMI 1640 medium (10% fetal calf serum, 1 mm sodium pyruvate) in bottles (37 C, 5% CO 2 ). The medium was replaced with ml fresh medium. Control Jurkat cells (TCC) were seeded at 0.4 x 10 6 cells/ml in RPMI 1640 medium and grown for 3 days (37 C, 5% CO 2 ). Two centrifugation steps (300 x g, 10 min, 2 8 C; 2,000 x g, 30 min, 2 8 C) were performed on conditioned medium before exosome pre-enrichment by ultracentrifugation or precipitation. Ultracentrifugation was performed using an Optima XPN-100 Ultracentrifuge (eckman Coulter; 100,000 x g, 70 min, 4 C) with a Type 45 Ti rotor. The Invitrogen Total Exosome Isolation Kit was used for precipitation of exosomes. Enriched exosomes were resuspended in PS. Magnetic capture of exosomes and analysis Exosomes were captured using Invitrogen Exosome- Human Isolation Reagent (Cat. No. 10614D) or Invitrogen Dynabeads Protein G (Cat. No. 10003D) coupled to Invitrogen Monoclonal ntibody (Ts9) (Cat. No. 10626D). For magnetic capture using multiple exosomal markers, prototype magnetic beads targeting, CD63, or CD81 were mixed prior to capture. Prototype magnetic beads coated with antibodies targeting, CD63, and CD81 on each bead were used for comparison. For generic capture of exosomes, prototype magnetic beads targeting exosome membranes were used for isolation. 20 µl of magnetic beads (flow cytometry: 1 x 10 7 beads/ ml; western blotting: 1.3 x 10 8 beads/ml) were washed in 200 µl PS (0.1% S, 0.2 µm filtered). 100 µl cell medium containing exosomes were added to the magnetic beads and incubated for 16 20 hr at 4 C. The magnet was applied, and exosome-coated beads were washed in 0.3 ml of PS (0.1% S) for flow cytometry. 100 µl was used for staining with Mouse nti-human PE (D iosciences, Cat. No. 555372) and incubated for 45 60 min on a shaker (1,0 rpm) at room temperature (RT) in the dark. Flow cytometry analysis using the LSRFortessa system (D iosciences) or western blotting was performed as described [23]. Electron microscopy Immunolabeling and negative-staining transmission electron microscopy were performed using Invitrogen CD81 Monoclonal ntibody (Cat. No. 10630D), glowdischarged carbon-coated copper grids, uranyl acetate, rabbit anti-mouse antibody, and protein gold (CMC Utrecht, Netherlands) [22]. Chemiluminescence assay Labeled antibodies were prepared by mixing µg IgG in sodium phosphate with acridinium ester for 30 min at RT. The reaction was quenched with 20 mm sodium phosphate containing 10% lysine for 15 min at RT. The antibody was purified using a NP-5 column (GE, Cat. No. 17-0853- 02) and TST. Light emission was triggered with 1.32% H 2 O 2 and 0.35 M NaOH. Chemiluminescence detection was performed with the Centro L 960 Luminometer (erthold Technologies). utomated immunoprecipitation and analysis The Thermo Scientific KingFisher Flex Purification System With 96 Deep-Well Head (Cat. No. 5400640) and indit 3.3.1 software was used for automated immunoprecipitation and downstream analysis. Electrophoresis and western blotting were performed using the Invitrogen olt system. Results Workflow typical workflow, exemplified here by flow cytometry, is divided into 3 major steps (Figure 1). The first step is the pre-enrichment step. In this step, the cell culture medium is collected. Pre-enrichment is done either by ultracentrifugation or precipitation. lternative methods such as filtration or size-exclusion chromatography are also used. Specific capture using exosome surface markers as targets is performed in the second step. The third step is labeling of the captured exosomes. Cell culture Preenrichment Ultracentrifugation: Differential Cushion Gradient Precipitation Filtration Size exclusion chromatography Magnetic Capture Staining Figure 1. Exosome enrichment, specific capture, and analysis workflow.

Magnetic bead optimization The downstream application determines the number of magnetic beads used for exosome capture (Figure 2). For flow cytometry, a strong signal is obtained by keeping the number of beads very low. This strategy helps ensure a high density of exosomes per magnetic bead and a good signal. If the remaining supernatant is analyzed to quantify the number of exosomes left, the data is expected to demonstrate that very few exosomes have been pulled out. In contrast, western blotting requires a large total surface area in order to give a strong signal but leaves very few exosomes in the supernatant. Flow cytometry of exosomes isolated with magnetic beads typical flow cytometry signal after isolation of - positive exosomes from SW480 cells is demonstrated in Figure 3. s a control, -negative exosomes from Jurkat cells were included (Figure 3C). The exosomes were isolated by targeting followed by staining. The scatter plot and gating profile is demonstrated in Figure 3. Flow cytometry and western blot analysis of exosomes -labeled exosomes from SW480 cells were isolated directly without pre-enrichment and analyzed by flow cytometry and western blot. Figure 4 shows a correlation between increased signal-to-noise ratio (S/N) and increased bead input following flow cytometry analysis. Figure 4 compares direct isolation with exosomes preenriched by ultracentrifugation (UC) or precipitation. The results were compared with equal amounts of exosomes. 100 1 200 2 300 Flow S/N 60 40 30 CD81 Western blotting 20 10 1 10 2 10 3 10 4 10 5 PE- 10 Fold increase 1x 5x 10x 15x 20x 25x mount of beads Figure 2. Dynabeads magnetic bead optimization. isolation SSC- (x1000) 100 1 200 2 100 1 200 2 FSC- (x1000) SW480 Jurkat C 0 100 1 200 2 300 0 100 1 200 2 300 10 1 10 2 10 3 10 4 10 5 PE 10 1 10 2 10 3 10 4 10 5 S/N 10 8 6 4 2 0 5.3 7.9 11.2 28 KDa 100 μl 200 μl 400 μl Direct UC Prec Direct capture Cell culture Figure 3. Flow cytometry of exosomes isolated with Dynabeads magnetic beads. Figure 4. Flow cytometry and western blot analysis of exosomes isolated with Dynabeads magnetic beads.

100 nm 0 0 Capture using multiple exosomal markers Flow cytometry and western blot analysis were performed after exosome isolation by targeting, CD63, and CD81. In Figure 5, magnetic beads targeting, CD63, or CD81 were mixed prior to capture followed by staining and flow cytometry. In Figure 5, magnetic beads coated with antibodies targeting, CD63, and CD81 on each bead were used for isolation followed by staining and flow cytometry. Figure 5C shows exosomes isolated using each method and analyzed by western blotting. utomation chemiluminescence assay for comparing performance using manual or automated isolation is shown in Figure 7. In this method, antibodies are labeled with acridinium prior to binding to Dynabeads Protein G. The amount of antibodies bound is estimated by measuring chemiluminescence. Chemiluminescence assay Generic isolation, release, and recapture Chemiluminescence labeled bs Dynabeads Protein G Chemiluminescence s s Mix 1 100 Triple 1 100 10 1 10 2 10 3 10 4 10 5 C 28 KDa Mix Triple Magnetic beads Figure 7. ssay for comparing performance of manual vs. automated isolation. utomated vs. manual pull-down, recovery, and reproducibility Manual and automated pull-down of target is compared in Figure 8, indicating slightly better recovery of target when using the manual protocol. The variation is very similar for manual and automated methods. Day-to-day and operator variation was addressed, and showed an overall coefficient of variation (CV) of 5.0% (Figure 8). Figure 5. Capture using Dynabeads magnetic beads with multiple exosomal markers. Magnetic beads targeting exosome membranes were used for generic isolation of exosomes. The exosomes were then analyzed by transmission electron microscopy (TEM), western blotting, and flow cytometry. Figure 6 shows ultrastructural analysis of the isolated exosomes by TEM. fter isolation and release, captured exosomes were analyzed by western blotting (Figure 6) and by immunolabeling and negative-staining TEM (Figure 6C). The released exosomes were recaptured and processed for flow cytometry (Figure 6D). Released C D 100 1 200 Captured CD81 100 nm Released 100 nm 100 1 200 10 2 103 10 4 105 PE- Sample 1 2 3 4 5 6 7 8 Mean STD CV Day 1, operator 231,884 234,854 233,403 230,895 234,249 238,061 230,513 233,182 KingFisher system 185,300 187,178 182,220 182,645 178,543 181,268 178,185 180,840 182,023 3,082 1.7 % Day 2, operator 257,407 257,253 253,4 259,065 258,486 257,595 261,522 258,035 Manual 199,863 204,333 202,336 207,603 202,148 198,240 205,363 201,458 202,668 3,017 1.5 % Day 1, operator 256,915 263,366 260,675 264,146 256,563 260,865 289,933 257,354 Recaptured 10 2 103 10 4 105 PE- Overall Mean STD CV 2,405 12,564 5.0 % Figure 6. Isolation, release, and recapture of exosomes using magnetic beads targeting exosome membranes. Figure 8. Recovery and reproducibility using automated and manual pull-down.

ackground staining ackground analysis using silver staining after automated or manual immunoprecipitation (IP) is shown in Figure 9. Similar background staining was observed using both methods. For comparison, lysate prior to IP and antibody were included. Conclusions Standardization of EV isolation and characterization has been a highly requested need of the International Society of Extracellular Vesicles (ISEV) for several years. highly reproducible method for pull-down and analysis was developed using the KingFisher Flex Purification System in combination with Dynabeads magnetic beads. Critical parameters identified affecting automated pull-down include: Mixing conditions during washing (loss of binding) Number of washing steps (loss of binding) Elution volume (increased yield with increased volume) Std ut. ut. ut. Man. Man. Man. Std b Lysate 1 2 3 1 2 3 Figure 9. ackground staining after manual or automated IP. Manual vs. automated IP comparison of manual and automated IP was performed using the KingFisher Flex Purification System and Dynabeads Protein G coupled to antibody (Figure 10). Similar results were observed after western blotting and staining using both methods. kda 63 49 38 28 17 14 HeLa Man. ut. lysate Dynabeads Protein G References 1. obrie, et al. (2011) Traffic 12:1659 1668. 2. Thery C, et al. (2002) Nature Rev Immunol 2:569 579. 3. Janowska-Wieczorek, et al. (2005) Int J Cancer 113:752 760. 4. elting M, et al. (2008) J Cell iol 183:1187 1191. 5. Pegtel DM, et al. (2011) iochim iophys cta 1809:715 721. 6. Valadi H, et al. (2007) Nature Cell iol 9:654 659. 7. l-nedawi K, et al. (2008) Nature Cell iol 10:619 624. 8. Mittelbrunn M, et al. (2011) Nature Comm 2:282. 9. Skog J, et al. (2008) Nature Cell iol 10:1470 1476. 10. Zomer, et al. (2010) Commun Integr iol 3:447 4. 11. Lasser C, et al. (2012) J Vis Exp:e3037. 12. Conde-Vancells J, et al. (2008) J Proteome Res 7:5157 5166. 13. Subra C, et al. (2010) J Lipid Res 51:2105 2120. 14. Mathivanan S, et al. (2009) Proteomics 9:4997 00. 15. Thery C, et al. (2006) Curr Prot Cell iol Chap 3, Unit 3:22. 16. Cheruvanky, et al. (2007) m J Physiol 292:F1657 1661. 17. Li Q, et al. (2014) J iol Chem 289:1303 1312. 18. Munoz JL, et al. (2013) Mol Therapy Nucleic cids 2:e126. 19. Zeng L, et al. (2013) J iol Chem 288:31853 31866. 20. Chugh PE, et al. (2013) PLoS Pathogens 9:e1003484. 21. Clayton, et al. (2001) J Immunol Meth 247:63 174. 22. Ericsson M, et al. (1995) J Virol 69:7072 7086. 23. Oksvold MP, et al. (2014) Clin Therap 36:847 862. Figure 10. staining after manual or automated IP.

Find out more at thermofisher.com/kingfisher For Research Use Only. Not for use in diagnostic procedures. 2017 Thermo Fisher Scientific Inc. ll rights reserved. ll trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. Optima and LSRFortessa are trademarks of eckman Coulter. COL31531 0417