MAGLUMI 1000 MAGLUMI 1000

Similar documents
Caris 200 Fully Automated Chemiluminescence Immunoassay (CLIA) System

Bead Chemiluminescense IMMULITE 2000, 2000 XPI & 2500

PLUNGER ( ) Not applicable. Field Safety Corrective Action (FSCA)

Catalogue number Product Quantity. Catalogue number Product Quantity. SO LIAISON anti HAV 100 tests

ELISA. AccuDiag Autoimmune Diseases and Others. ANA Screen Qualitative ~135 min 90.4% 100%

DiaSorin Group Company Presentation. March 2019

Product List Autobio Diagnostics. Autobio. autobio diagnostics an autobio group company

guide Immunoassay Analyzers

PRODUCT LIST 2018 Immunoassays RIA, IRMA, REA

Tel: Tel: Web: CODE DESCRIPTION UNITS

ELISA System Line. Analyzers and Reagents. CoreLab DX ELISA. > Instruments for all kinds of laboratories > Broad range of parameters > Proven quality

PRODUCT LIST 2011 Immunoassays RIA, IRMA, REA

J.P. Morgan Global Healthcare Conference

ELISA System Line. Analyzers and Reagents ELISA. > Instruments for all kinds of laboratories > Broad range of parameters > Proven quality

TEST LIST SAMPLE REQUIREMENT. 1 ml serum None

Thyroid Care & Diagnostic Centre

BÁO GIÁ HÓA CHẤT MIỄN DỊCH

Immunoassay. Product Portfolio. Part of the IDS group

DS-EIA-ANTI-HIV-UNIF (Ab) I DS-EIA-ANTI-HIV-UNIF (Ab) I DS-EIA-ANTI-HIV-UNIF (Ab) I

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010

Controls & Calibrators. Disease Quality Controls

Company Presentation. Product availability mentioned in this presentation is subject to local regulatory approval

Bio-Rad Laboratories EQAS. External Quality Assurance Services

Product List Autobio Diagnostics Autobio. autobio diagnostics an autobio group company

Third Party Controls for Your Dade Behring Systems

Company presentation

DECLARATION OF CONFORMITY

MADE IN KOREA. Advanced POCT. Automated 6 Channels. Automated Single Channel. POCT to Desktop. Our technology covers it all!

VITROS MicroWell Assay Summary

SCOPE OF ACCREDITATION TO ISO/IEC 17043:2010

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

PROFILES MENU. Page no. 9 Page no. 8 Page no. 7 Page no. 6 Page no. 5. Page no. 2. Page no. 4 Page no. 3

Types of target values, acceptable ranges

ELISA kits for infections (HIV; Hepatitis A, B, C, D, E; Syphilis, ToRCH and others), hormone pathologies and tumor markers.

Minimum Whole Blood Volumes for Microcollection Tubes for Neonates, Pediatrics, Patients less than 45 kg (100 lb) and Difficult Collections

External Quality Assurance Services EQAS. Participate in an internationally recognized quality assessment program

Answering your daily challenges. in the ELISA technology I N FECTI OUS DISEASES. bioelisa

Product Catalog

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

Specific Panels. Celiac disease panel. Pancreas Panel:

AFIAS 6 (Automatic Fluorescence Immuno-Assay)

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

Annex to the Accreditation Certificate D-EP according to DIN EN ISO/IEC 17043:2010

)Beta Estradiol (E2-71 OH-Progesterone-71 OH-Vitamin D3-05

Innovation in Diagnostics. ToRCH. A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES

QUALITY CONTROL. Linearity Sets

ICL Integrative Laboratory Services Test Menu Contact ICL Client Care x300

JAJ International, Inc./LuSys Laboratories, Inc.

Code TEST SPECIMEN REQUIREMENT TAT Referral centre. 1 week BP GM (Specimen stability: 2-8 C for 48 hours) 3240 Anti-ds DNA 3 ml Plain Blood/Serum

A007 Allergy Basic Profile (28 parameters) 5 ml Plain Blood/Serum week BPGM

2018 Roadshow Presentation

Saskatchewan ND Price List

Controls & Calibrators Clinical Chemistry

Premium Controls for Immunochemistry

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

Immunoassays RIA & ELISA PRODUCT LIST JUNE 2018

The PATH to better cardiac care starts here

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION

MEMORANDUM. These reference ranges are effective immediately but sample requirements remain unchanged currently.

Tests by age. specific inherited syndromes and inflammatory bowel disease

ONTARIO ND PRICE LIST

Overseas Referred Tests 2014

Living Immunoassay Excellence

Biokit Label Catalog. Living Immunoassay Excellence

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

S M A R T. tat testing aximum menu dvanced fluoresence immunoassay esults comparable to reference methods rouble-free. Revolution in Diagnostics

Multichem Infectious Disease QC

We are pleased to present the new Leaflet bioelisa Menu and Instrumentation, with reference

Instructions for Use. Tg Antibody ELISA

Apolipoprotein A Apolipoprotein B ASOT Aspergilli 1/ Aspergilli 2 Aspirate Fluid for Culture AST(SGOT) Anti-TG AB Anti-TPO AB(Thyroid Peroxidase)

: New graphic materials for bioelisa and bioblot product lines

PRICES 01 JANUARY 2017 TEST AMOUNT $ SEROLOGY ANF-Fluorescent Ab test ASOT-Latex aggl.-titre if pos 6.00 BFAT-Fluorescent Ab test 25.

RIQAS RANDOX INTERNATIONAL QUALITY ASSESSMENT SCHEME

Speciality and Research Controls

Bio-Rad Laboratories EXTERNAL QUALITY ASSURANCE SERVICES EQAS. External Quality Assurance Services

QUALITY CONTROL Infectious Disease

Current September 2017

The next generation portable diagnostics system: Over 20 parameters available!

Quantitative Measurement of Emergency Biomarkers in Parallel

CERTIFICATE OF ACCREDITATION

Authorised: JSWoodford, Lead of Speciality. Biochemistry Reference Intervals, October Page 1 of 5

PRODUCT CATALOGUE YOUR GLOBAL PARTNER IN DIAGNOSTICS

EC Declaration of Conformity (Directive 98/79/EC)

Assays for therapeutic drug monitoring

READ HIGHLIGHTED CHANGES

Quantitative Measurement of Cardiac Biomarkers

$ Glucose Only $ 9.00 Detects diabetes or a pre-diabetic condition.

Analyte Specimen Demographic Reference Range Units

1. Purpose 1.1. To define testing locations, schedule and order priority for each test performed in the core laboratory.

Biochemistry Adult Reference Ranges

CHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) Toxoplasma IgG. Cat # (20-25 C Room temp.) Volume

Royal College of Pathologists of Australasia Allowable Limits of Performance

CERTIFICATE OF ACCREDITATION

Cardiac Assessment Controls A critical element of reliable cardiac testing

EC CERTIFICATE. National Institute for Biological Standards and Control (NIBSC) Blanche Lane South Mimms Potters Bar Hertfordshire EN6 3QG UK

ACCREDITATION DOCUMENT

SydPath Reference Intervals for Clinical Trials (Contract Pathology Unit) Unauthorised Copy

Transcription:

MAGLUMI 1000

Outstanding Technology Power of MAGLUMI Chemiluminescence Immunoassay (CLIA) System CLIA uses two important technologies, one is labeling technology which determines reaction mode; and the other is separation technology which determines the sensitivity, accuracy and precision of the reagents. Labeling Technology Two types of labeling technologies are commonly used. One is enzyme label and the other is non-enzyme samll molecule label. Enzyme label reagents are not so stable and are easily effected by the change of storage conditions. Maglumi system applies ABEI labels. ABEI is a non-enzyme samll molecule with special molecular formula to enhance stability in acid and alkaline solution. As for chemiluminescence, ABEI chemical reaction with sodium hydroxide (NaOH) and Hydrogen peroxide (H 2 O 2 ) finishes the process in 3 seconds. Separation Technology Maglumi uses Magnetic Microbeads. As separation technology, it has been widely used in the field of CLIA. Compared with traditional separation technology, it has the following advantages: Shortening the reaction time by enlarging the reaction area of antigens and antibodies. Enhancing the sensitivity by better and faster capture of antigens and antibodies. Reducing inter or intra-assay discrepancies significantly by mixing the reagents thoroughly in a liquid separation platform. Enhancing the accuracy by absorbing antigens and antibodies through chemical reaction.

Advantages of MAGLUMI 1000 For Mid-size hospitals More than enough test menu to meet the different needs and it will be extended according to your requirement Free Quality Control and calibrator help to reduce the Cost Per Test Quality guarantee by the Third party quality control and External Quality Assessment (EQA) Key technology ABEI and Nano magnetic microbead enhances stability and sensitivity of MAGLUMI reagents 76 cm 135 cm 158 cm

MAGLUMI 1000 Pipettor Aspirate reagent/sample with high speed Titanium needle for crushproof Clot detection & liquid level detection Coated with TEFLON to prevent carry-over Inner & external washing Chamber High-sensitivity and low-noise PMT Cuvettes detection and anti-overflow Washer Automated cuvette loader Capable of loading modules continuously Up to 120 reaction modules Strong magnetic field helps better separation Three pairs of washing needles with anti-overflow function Reagent area Cooling function 15 Reagents on board continuous loading RFID label storing reagent information RFID tag,high reliability Easy and fast for adding and updating Sample area Up to 144 samples on board with barcode Continuous loading & cooling function Random, batch, and STAT modes Incubator 16 Incubate slots (96 tests at the same time) The temperature is 36.8 ±0.5

Operation Software Comprehensive software User-friendly Interface Real-time status monitoring for each test Monitoring reagent and consumable status Intelligent alarm function Maintenance Guide Daily, weekly and monthly maintenance guide for analytical unit Ensure performance reliability QC Quality control Westgard rules and Levey-Jennings chart for both internal and external quality control Test Summary Function Test summary including system test, calibration, QC, statistics of samples, valid tests and rerun tests Search and review test information conveniently Pre or post defined dilution Function Pre or post defined dilution flexibly if high concentration is met Connect to LIS ( bidirection ) Bidirection, Lis can connect by online and ASTM

Test Menu Tumor Markers Fertility TORCH Drug Monitoring Ferritin AFP CEA Total PSA f-psa CA 125 CA 15-3 CA 19-9 Tg(Thyroglobulin) PAP CA 50 CYFRA 21-1 CA 242 CA 72-4 NSE S-100 SCCA TPA-snibe Pepsinogen I Pepsinogen II Gastrin-17 H.pylori IgG Calcitonin Proinsulin *H.pylori IgA *H.pylori IgM *progrp *AFP-L3 *HE4 *PIVKA-II *HER-2 Bone Metabolism Calcitonin Osteocalcin 25-OH Vitamin D Intact PTH *PINP Glyco Metabolism C-Peptide Insulin ICA IAA(Anti Insulin) Proinsulin GAD 65 Anti-IA2 Anemia Vitamin B 12 Ferritin Folate (FA) FSH LH PRL Estradiol Testosterone free Testosterone DHEA-S free Estriol Progesterone 17-OH Progesterone AMH *SHBG *Androstenedione *PLGF *sflt-1 Thyroid TSH (3rd Generation) T 4 T 3 FT 4 FT 3 Tg(Thyroglobulin) TGA(Anti-Tg) Anti-TPO TRAb TMA Rev T 3 Intact PTH Prenatal Screening cafp PAPP-A free Estriol Inflammation Monitoring hs-crp PCT(Procalcitonin) *IL- 6 Kidney Function 2 -MG Albumin Toxo lgg Toxo lgm Rubella lgg Rubella lgm CMV lgg CMV lgm HSV-1/2 lgg HSV-1/2 lgm HSV-2 lgg *HSV-2 IgM *HSV-1 IgG *HSV-1 IgM EBV EBV EA lgg EBV EA lga EBV VCA lgg EBV VCA lgm EBV VCA lga EBV NA lgg *EBV NA IgA Immunoglobulin lgm lga lge lgg Hepatic Fibrosis HA PIIIP N-P C IV Laminin Cholyglycine Infectious Disease HBsAg Anti-HBs HBeAg Anti-HBe Anti-HBc Anti-HCV Syphilis Chagas HTLV I/II Anti-HAV HAV IgM HIV p24 Ag HIV Ab/Ag combi H.pylori IgG *H.pylori IgA *H.pylori IgM *Anti-HBc IgM CSA (Cyclosporine A) FK 506 (Tacrolimus) Digoxin Cardiac CK-MB Troponin I Myoglobin NT-proBNP Aldosterone Angiotensin I Angiotensin II D-Dimer LP-PLA2 hs-ctnl hs-crp Direct Renin *H-FABP *BNP Autoimmune TGA(Anti-Tg) TRAb TMA Anti-TPO ICA IAA(Anti Insulin) GAD 65 Anti-IA2 *Anti-CCP *Anti-dsDNA *ANA *ENA *Anti-Sm *Anti-Ribosomal-P *Anti-Scl-70 *Anti-CENP-B *Anti-Jo-1 *Anti-M2 *Anti-Histone *Anti-RNP *Anti-SSB *Anti-SSA Others GH(hGH) IGF-I Cortisol ACTH *IGFBP-3 Available soon

MAGLUMI 1000 M1004E01-171010