Cell Damage. Standardized and automatic determination of DNA double strand breaks using immunofluorescence

Similar documents
Assays. New. New. Combinations. Possibilities. Patents: EP , AU

Simultaneous comprehensive multiplex autoantibody analysis by CytoBead technology for Rapidly Progressive Glomerulonephritis.

Product Guide. Valid from June 15 th, Simply innovative diagnostics

Mobile phone radiofrequency exposure has no effect on DNA double strand breaks (DSB) in human lymphocytes

Stefan Rödiger 1,2, Marius Liefold 3, Madeleine Ruhe 1, Mark Reinwald 4, Eberhard Beck 3, P. Markus Deckert 4. Original Article

DSB. Double-Strand Breaks causate da radiazioni stress ossidativo farmaci

Advances in biological dosimetry

Chapter 2. Aims & Objectives

Quantitative Theranostics in Nuclear Medicine

In vitro human regulatory T cell suppression assay

Cryptosporidium Proficiency Test Program for Laboratories using US EPA Method 1623: Cryptosporidium and Giardia

Tumour growth environment modulates Chk1 signalling pathways and sensitivity to Chk1 inhibition

LYMHOCYTE CHROMOSOMAL ABERRATION ASSAY IN RADIATION BIODOSIMETRY

Removal of Shelterin Reveals the Telomere End-Protection Problem

In vitro human regulatory T cell expansion

Basics of Radiation Biology

Basics of Radiation Biology

In vitro human regulatory T cell expansion

Clastogenic factors in blood plasma obtained from subjects exposed to. Carita Lindholm STUK - Radiation and Nuclear Safety Authority

WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: Pima CD4 Test Number: PQDx Abstract

Radiation induced DNA double strand breaks undergoing PET/CT examinations.

Developing Auto-focusing Microscopy For Ultra High- Throughput Biodosimetry

(a) Schematic diagram of the FS mutation of UVRAG in exon 8 containing the highly instable

Importance of ATM in Radiotherapy

Computational Systems Biology Modeling of DNA-damage Stress Pathways for Assessing Mutation Rates at Low Doses

Genome Instability is Breathtaking

ADVANTAGES OF MICRONUCLEI ANALYSIS THROUGH IMAGES AUTOCAPTURING AND SCREEN SCORING

RayBio Annexin V-Cy5 Apoptosis Detection Kit

DSB. Double-Strand Breaks causate da radiazioni stress ossidativo farmaci

Removal of Shelterin Reveals the Telomere End-Protection Problem

Cellometer Image Cytometry for Cell Cycle Analysis

The application of 1.6 MeV proton microbeam to investigate radiation-induced bystander effect in MIA PaCa-2 pancreatic cancer cell line

FISH and PNA-FISH. FISH and PNA-FISH. Stochastic effect. Radiation and cancer. 1) chromosome 2) FISH 3) PNA-FISH. Chromosome translocations.

DNA damage in subpopulations of human lymphocytes irradiated with doses in the range of 0 1 Gy of X-radiation

Hadrons on Malignant Cells: Recent Activities within Collaboration between LNS INFN and Vinca Institute of Nuclear Sciences

Health Physics and the Linear No-Threshold Model

Radiation Carcinogenesis

Prolonged mitotic arrest induces a caspase-dependent DNA damage

Alere Technologies GmbH

Dako IT S ABOUT TIME. Interpretation Guide. Agilent Pathology Solutions. ALK, ROS1 and RET IQFISH probes (Dako Omnis) MET IQFISH probe (Dako Omnis)

María José Mesa López

QIAsymphony DSP Circulating DNA Kit

A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis

SUPPLEMENTARY INFORMATION

Direct ex vivo characterization of human antigen-specific CD154 + CD4 + T cells Rapid antigen-reactive T cell enrichment (Rapid ARTE)

Data Sheet. CD28:B7-2[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Ping Li, Cheng-run Du, Wen-cai Xu, Ze-liang Shi, Qing Zhang, Zhao-bin Li and Shen Fu *

Microsart Calibration Reagent

Genotoxicity of formaldehyde in vitro and in vivo. Günter Speit

Rapid antigen-specific T cell enrichment (Rapid ARTE)

Muse Assays for Cell Analysis

DEVELOPMENTAL VALIDATION OF SPERM HY-LITER EXPRESS Jennifer Old, Chris Martersteck, Anna Kalinina, Independent Forensics, Lombard IL

The Role of ATM (ataxia-telangiectasia mutated) in the mitochondrial pathway of apoptosis

Phagocytosis of FITC labelled opsonized and non-opsonized E. coli bacteria by monocytes and granulocytes in a whole blood assay

Supplementary Figure 1

Off-label use of statins for the prevention of radiation-induced normal tissue damage

PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)

SUPPLEMENTAL FIGURE LEGENDS

ANDROVISION - MORE THAN CASA

Shuttling towards a predictive assay for radiotherapy

Supplementary Appendix

Supplementary Figure 1: si-craf but not si-braf sensitizes tumor cells to radiation.

Evaluation of DNA damage induced by proton and lithium beams in murine melanoma cells

association with genomic instabilit

DNA double-strand break repair of parental chromatin in ooplasm and origin of de novo mutations. Peter de Boer

XF Data Normalization by the Agilent Seahorse XF Imaging and Normalization System

Radiation Oncology. Initial Certification Qualifying (Computer-based) Examination: Study Guide for Radiation and Cancer Biology

Product Overview CELL-FREE DNA BCT CELL-FREE RNA BCT CELL-FREE DNA URINE PRESERVE CYTO-CHEX BCT STRECK CELL PRESERVATIVE

Supplementary Figure S1: Defective heterochromatin repair in HGPS progeroid cells

For the rapid, sensitive and accurate measurement of apoptosis in various samples.

MHC MULTIMER PROFICIENCY PANEL 2017

Evidence for variation in human radiosensitivity: potential impact on radiological protection

List of Papers. This thesis is based on the following papers, which are referred to in the text by their Roman numerals.

ab CytoPainter Golgi/ER Staining Kit

Reliable. results. efficiently. for CH, galactosemia, CAH and CF screening

VUmc Basispresentatie

CONTRACTING ORGANIZATION: Fred Hutchinson Cancer Research Center Seattle, WA 98109

Verification of the PAGAT polymer gel dosimeter by photon beams using magnetic resonance imaging

Abbott Cell-Dyn Reticulocyte Method Comparison and Reticulocyte Normal Reference Range Evaluation

Rat Hemoglobin A1c (HbA1c) Kit Instructions

Ex vivo functional assays for Homologous Recombination deficiency in breast cancer. Dik C. van Gent

Supplementary Figure 1

Optimizing Intracellular Flow Cytometry

Two-Dimensional Thermoluminescence Dosimetry System for Proton Beam Quality Assurance

The effects of computed tomography derived low doses on human peripheral blood cells

Standard Operating Procedure

Computerized semen analysis. Product features. Basic system

Variation of Urinary 8-Hydroxy-deoxyguanosine in Patients during Radio-therapeutic Course

HER2 FISH pharmdx TM Interpretation Guide - Breast Cancer

PREPARED FOR: U.S. Army Medical Research and Materiel Command Fort Detrick, Maryland

RayBio Acid Phosphatase Activity Colorimetric Assay. Kit. User Manual Version 1.0 May 5, RayBiotech, Inc. Kit Protocol. (Cat#: 68CL-AcPh-S500)

Application of a Multiplexed Flow Cytometric Assay and Machine Learning to Provide Genotoxic Mode of Action Information

Genome Stability Department of Physiology

Essential Medium, containing 10% fetal bovine serum, 100 U/ml penicillin and 100 µg/ml streptomycin. Huvec were cultured in

Know for sure! Your Power for Health. PapilloCheck and PapilloCheck high-risk HPV-Genotyping: The Clear Edge in Early Detection of Cervical Cancer.

High Sensitivity Immunomagnetic CTC Isolation as Compared to Alternative Isolation Methods

WHO Prequalification of Diagnostics Programme PUBLIC REPORT

DC were seeded into tissue culture dishes in IMDM 2% FCS, and added with PMN. (1:1; PMN: DC) for 16h also in the presence of DNAse (100 U/ml); DC were

Background Information

Transcription:

Standardized and automatic determination of DNA double strand breaks using immunofluorescence Patents: CN 2702421, EP 2208068, TR 201308237, 200880115751

The Platform Motorized, inverse fluorescence microscope with 4 objectives Motorized x-y stage holding up to 5 slides LED light source (4 wavelength) CCD grey scale camera PC including AKLIDES software Applications for γ-h2ax as a biomarker Radiation biology / Biodosimetry Assessment of individual Sensitivity to Radio- and Chemotherapies Autoimmune and Age-related Diseases Environmental Genotoxicity/Drug Development Genome Integrity / DNA repair pathways

Biomarkers for Cellular Stress Response Quantitative determination of DNA double-strand breaks (DSB) via immunofluorescence Standardized and automatic image analysis for the determination of DNA double-strand breaks for the first time comparability of examination results possible suitable for medical screening Automatic determination of foci with different fluorescent dyes Combined determination of foci with different dyes for the evaluation of DNA repair mechanisms Modular software for the analysis of various cell lines and human lymphocytes Advantages automatic analysis Standardized and reliable results between different instruments due to intensity calibration of LED light source Standardized assay results due to novel microbead based reaction control Integrated dark chamber Detailed results via readout of various parameters Number of cells measured Number of cells with foci Average number of foci per cell Mean intensity of foci Percentage of cells with foci = total cell damage Average diameter of foci and cells Sample specific reports in pdf and xls format Database and archiving of results 8 minutes analysis/well with 100 cells counted 5 times faster analysis compared to manual reading Time, staff and cost efficient analysis

Scientific background DNA damage such as DNA double-strand breaks (DSBs) have been observed following exposure to ionizing radiation or mutagenic substances such as cytostatic chemicals. Cells are able to recognize this damage and repair it. This DNA repair is usually accurate and has no consequences for the cell. However, excessive DNA damage can lead to cell death or even oncogenic transformation of the cell. The knowledge of the formation and of the repair of DNA damage in particular are an important requirement to avoid pathological changes and to assure optimal application of ionizing radiation in medicine and technology. DNA double-strand breaks are recognized very quickly and efficiently by the cell. The kinase ataxia telangiectasia mutated (ATM) is responsi- ble for this. Serine 139 of the histone subunit H2AX is phosphorylated, and is then named γ-h2ax. The p53 binding protein 53BP1 binds the phosphorylated H2AX and regulates the repair of DNA double-strand breaks. Specific antibodies detect γ-h2ax as well as 53BP1 and specific secondary fluorochrome labeled antibodies visualize each marker (figure 1). The resulting fluorescence signal can be visualized as a focus (pixel) under a fluorescent microscope. γ-h2ax as well as 53BP1 form foci which colocalize to a certain degree. After exposure to radiation or genotoxic substances an increase in foci numbers depending on dosage can be seen (figure 2). Figure 1: Schematic illustration of DSB detection via immunofluorescence staining of γ-h2ax foci. Figure 2: Dose-response of γ-h2ax foci in human cells after irradiation (Runge et al. Int J Radiat Biol, May 2012; 88(5): 439-447)

Analysis of γ-h2ax foci is an established marker of DNA double-strand breaks and therefore cell damage, whereas DNA repair mechanisms can be evaluated using the fraction of p53 binding protein 53BP1. Combining the analysis of γ-h2ax with the determination of 53BP1 and analyzing their colocalization can be used to evaluate cellular repair mechanisms (figure 3). Using immunofluorescence to analyse these foci is a very sensitive method evaluating single cells as well as the localization of foci. These parameters can be measured fully automatically using the AKLIDES Nuk Software. Ø Foci/ cell 1,400 1,200 1,000 0,800 0,600 0,400 0,200 0,000 Average number of foci per cell Patient 1 Patient 2 γh2ax 53BP1 Analyzing the kinetics of DNA damage and repair individual differences or repair defects can be detected. After exposure to irradiation the number of γ-h2ax foci show a steep increase, followed by a continuous decrease back to basal levels for complete repair (figure 4). Cells with impaired DNA repair show increased foci numbers even after 24 hours of recovery. Figure 3: Assessment of γ-h2ax and 53BP1 foci This approach can also be used to screen the genotoxicity of various substances. Measuring DNA damage and DNA repair capacities of cells can be used as a diagnostic tool in various applications in basic research as well as clinical settings. Figure 4: Kinetics of γ-h2ax foci in cancer patients after irradiation with 1 Gy (Rübe et al., Int J Radiat Oncol Phys 2010 Oct 1; 78 (2): 359-69) References (1) Rübe CE, Fricke A, Schneider R, Simon K, Kuhne M, Fleckenstein J, et al. DNA repair alterations in children with pediatric malignancies: novel opportunities to identify patients at risk for high-grade toxicities. Int J Radiat Oncol Biol Phys 2010 Oct 1;78(2):359-69. (2) Runge R1, Hiemann R, Wendisch M, Kasten-Pisula U, Storch K, Zöphel K, Fritz C, Roggenbuck D, Wunderlich G, Conrad K, Kotzerke J. Fully automated interpretation of ionizing radiation-induced γh2ax foci by the novel pattern recognition system AKLIDES. Int J Radiat Biol. 2012 May;88(5):439-47. (3) Schmid TE, Zlobinskaya O, Multhoff G. Differences in Phosphorylated Histone H2AX Foci Formation and Removal of Cells Exposed to Low and High Linear Energy Transfer Radiation. Curr Genomics 2012 Sep;13(6):418-25. (4) Valdiglesias V, Giunta S, Fenech M, Neri M, Bonassi S. γh2ax as a marker of DNA double strand breaks and genomic instability in human population studies. Mutat Res 2013 Jul;753(1):24-40. (5) Willitzki A, Lorenz S, Hiemann R, Guttek K, Goihl A, Hartig R, et al. Fully automated analysis of chemically induced γh2ax foci in human peripheral blood mononuclear cells by indirect immunofluorescence. Cytometry A 2013 Nov;83(11):1017-26. (6) Reddig A, Lorenz S, Hiemann R, Guttek K, Hartig R, Heiserich L, Eberle C, Peters V, Schierack P, Sack U, Roggenbuck D, Reinhold D. Assessment of Modulated Cytostatic Drug Resistance by Automated γh2ax Analysis. Cytometry Part A 2015 Aug;87A:724-732. (7) Reddig A, Fatahi M, Friebe B, Guttek K, Hartig R, Godenschweger F, Roggenbuck D, Ricke J, Reinhold D, Speck O. Analysis of DNA Double-Strand Breaks and Cytotoxicity after 7 Tesla Magnetic Resonance Imaging of Isolated Human Lymphocytes. PLOS ONE DOI:10.1371/journal.pone.0132702 July 15, 2015.

The software module provides fully automated measurement Automatic focussing and cell identification are carried out with 60 times magnification in the DAPI channel (figure 5A). The sensitive determination of the γ-h2ax fluorescence signal takes place in the green FITC channel and in several z-levels (figure 5B). The same applies for 53BP1 measured in the red APC channel. For the automatic analysis the signals of DAPI, FITC and APC channels will be overlayed and the implemented algorithms generate a 3-dimensional matrix from the x, y and z coordinates of the detected foci. Every focus will be described by detailed parameters like size and intensity. Figure 5: Measurement of initial foci of PC Cl3 thyroid cells under radiation of 1 Gy 188 Re. A: Focussing and cell identification in the DAPI channel. B: Determination of fluorescence signal in the FITC channel. C: Overlay of both fluorescence signals. D: Analysis of foci parmeters (Runge et al., Int J Radiat Biol, May 2012; 88 (5): 439-447). Increased foci determination range The automatic analysis of foci using the AKLIDES Nuk software increases the range of foci determination. A comparison of manual and automatic foci determination using PC Cl3 thyroid cells shows a limited measurement range from 6 Gy for the manual analysis (figure 6A). In contrast automatic reading expands the range up to 8 Gy (figure 6B) and it could be increased additionally up to 10 Gy when total intensity is considered (figure 6C). Manual foci determination Automatic foci determination A B C Figure 6: Dose-response curves of manual and automatic analysis of irradiated PC Pl3 cells. A: Average number of foci per cell analyzed manually. B: Average numbers of foci per cell analyzed automatically with AKLIDES. C: Total intensity of foci analyzed with AKLIDES.

Standardized results due to integrated reaction control and intensity calibration of instruments Antigen coated beads (γ H2AX) A B Lymphocytes Figure 7: Differences between assays can be abolished using an integrated reaction control A: Antigen coated microbeads B: Irradiated lymphocytes The immunostaining procedure of assay control and lymphocytes are performed on the same slide so that differences between preparations can be abolished. γ H2AX coated microparticles serve as a reaction control producing intensities in a defined range. In combination with the calibration of the LED light source standardized and reliable results can be produced for this parameter. This means that for the first time comparison of results from different studies from all over the world are possible which is an important step for the clinical evaluation of γ H2AX. Archiving and result report Project name, slide number and lot Information about assay and slide, date and information about Result parameter of the sample and sample position respectively The detailed result report gives all the information necessary for the archiving and the construction of a result database.

Overview kits AKLIDES Nuk * Human Lymphocyte Complete Order code 4162 contains all reagents to detect γ-h2ax foci 10 slides for 30 duplicates or 60 single determinations AKLIDES Nuk * Human Lymphocyte Complete Combi Order code 4268 contains all reagents to detect γ-h2ax and 53BP1 foci simultaneously 10 slides for 30 duplicates or 60 single determinations AKLIDES Nuk * Human Lymphocyte Isolation Order code 4278 contains all reagents to isolate PBMCs from whole blood 10 slides for 30 duplicates or 60 single determinations The assays above use a standardized protocol for lymphocyte isolation and staining One technician can process 5 patient samples within 8 hours Storage of lymphocytes A minimum of 3 ml venous blood taken in 6 ml EDTA tubes should be processed immediately It is possible to store isolated lymphocytes as follows: Fixation of lymphocytes on slides and storage at 4 C Freezing of lymphocytes in specific media and storage in liquid nitrogen Determination Service Isolated lymphocytes can be stored fixed onto slides and then send to the MEDIPAN GMBH for analysis. * Nuk = nuclear cell damage MEDIPAN GMBH Ludwig-Erhard-Ring 3 15827 Dahlewitz / Berlin Germany Phone: +49 (0) 33708-4417-0 Fax: +49 (0) 33708-4417-25 info@medipan.de MP_BR_E_AKLIDES Nuk_Cell Damage_v005-2016-02-15